Skip to main content

2013 | OriginalPaper | Buchkapitel

From KinectTM to anatomically-correct motion modelling: Preliminary results for human application.

verfasst von : B. Bonnechère, V. Sholukha, F. Moiseev, M. Rooze, Jan S. Van Sint

Erschienen in: Games for Health

Verlag: Springer Fachmedien Wiesbaden

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The KinectTM sensors can be used as cost effective and easy to use Markerless Motion Capture devices. Therefore a wide range of new potential applications are possible. Unfortunately, right now, the stick model skeleton provided by the KinectTM is only composed of 20 points located approximately at the joint level of the subject which movements are being captured by the camera. This relatively limited amount of key points is limiting the use of such devices to relatively crude motion assessment. The field of motion analysis however is requesting more key points in order to represent motion according to clinical conventions based on so-called anatomical planes. To extend the possibility of the KinectTM supplementary data must be added to the available standard skeleton. This paper presents a new Model-Based Approach (MBA) that has been specially developed for KinectTM input based on previous validated anatomical and biomechanical studies performed by the authors. This approach allows real 3D motion analysis of complex movements respecting conventions expected in biomechanics and clinical motion analysis.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Cappozzo A, Della Croce U, Leardini A, Chiari L. Human movement analysis using stereophotogrammetry. Part 1: theoretical background. Gait Posture. 2005;21(2):186–96 Cappozzo A, Della Croce U, Leardini A, Chiari L. Human movement analysis using stereophotogrammetry. Part 1: theoretical background. Gait Posture. 2005;21(2):186–96
2.
Zurück zum Zitat Cappozzo A, Catani F, Croce UD, Leardini A. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clin Biomech. 1995;10(4):171–178CrossRef Cappozzo A, Catani F, Croce UD, Leardini A. Position and orientation in space of bones during movement: anatomical frame definition and determination. Clin Biomech. 1995;10(4):171–178CrossRef
3.
Zurück zum Zitat Ounpuu S, Davis R, DeLuca P. Joint Kinetics: methods, interpretation and treatment decision-making in children with cerebral pasly and myelomeningocele. Gait Posture 1996, 4:62–78CrossRef Ounpuu S, Davis R, DeLuca P. Joint Kinetics: methods, interpretation and treatment decision-making in children with cerebral pasly and myelomeningocele. Gait Posture 1996, 4:62–78CrossRef
4.
Zurück zum Zitat Leardini A, Chiari L, Della Croce U, Cappozzo A. Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artefact assessment and compensation. 2005;21(2):212–25 Leardini A, Chiari L, Della Croce U, Cappozzo A. Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artefact assessment and compensation. 2005;21(2):212–25
5.
Zurück zum Zitat Rohr, K. Incremental recognition of pedestrians from image sequences. Proc. IEEE CVPR 1993; 8–13 Rohr, K. Incremental recognition of pedestrians from image sequences. Proc. IEEE CVPR 1993; 8–13
6.
Zurück zum Zitat Regh, J. M., and T. Kanade. Model-based tracking of 2 articulated objects. Proc. IEEE CVPR 1995; 612–617 Regh, J. M., and T. Kanade. Model-based tracking of 2 articulated objects. Proc. IEEE CVPR 1995; 612–617
7.
Zurück zum Zitat Gavrila, D. M., and L. S. Davis. Towards 3-D model-based tracking and recognition of human movement: A multi-view approach. In Proceedings of the International Workshop on Automatic Face and Gesture Recognition, Zurich, 1995 Gavrila, D. M., and L. S. Davis. Towards 3-D model-based tracking and recognition of human movement: A multi-view approach. In Proceedings of the International Workshop on Automatic Face and Gesture Recognition, Zurich, 1995
8.
Zurück zum Zitat Cappozzo A, Catani F, Leardini A, Benedetti M, Della Croce U. Position and orientation in space of bones during movement: experimental artifacts. 1996, 11:90–100 Cappozzo A, Catani F, Leardini A, Benedetti M, Della Croce U. Position and orientation in space of bones during movement: experimental artifacts. 1996, 11:90–100
9.
Zurück zum Zitat Wagg D, Nixon M. Automated markerless extraction of walking people using deformable contour models. Computer Animation and Virtual Worlds. 1996, 15 (3-4):399–406 Wagg D, Nixon M. Automated markerless extraction of walking people using deformable contour models. Computer Animation and Virtual Worlds. 1996, 15 (3-4):399–406
10.
Zurück zum Zitat Kakadiaris I, Metaxes D. 3D human body model acquisition from multiple view. Proc. IEEE CVPR 1995, 3: 618–623 Kakadiaris I, Metaxes D. 3D human body model acquisition from multiple view. Proc. IEEE CVPR 1995, 3: 618–623
11.
Zurück zum Zitat Deutscher J, Blake A, Reid I. Articulated body motion capture by annealed particle filtering. Proc. IEEE CVPR 2000, 11: 941–944 Deutscher J, Blake A, Reid I. Articulated body motion capture by annealed particle filtering. Proc. IEEE CVPR 2000, 11: 941–944
12.
Zurück zum Zitat Isard M, Blake A: Visual tracking by stochastic propagation of conditional density. 4th European Conference on Computer Vision:Cambridge, UK 1996:343–356 Isard M, Blake A: Visual tracking by stochastic propagation of conditional density. 4th European Conference on Computer Vision:Cambridge, UK 1996:343–356
13.
Zurück zum Zitat Legrand L, Marzani F, Dusserre L: A marker-free system for the analysis of movement disabilities. Medinfo 1998, 9(2):1066–1070 Legrand L, Marzani F, Dusserre L: A marker-free system for the analysis of movement disabilities. Medinfo 1998, 9(2):1066–1070
14.
Zurück zum Zitat Cheung G, Baker S, Kanade T: Shape-from-silhouette of articulated objects and its use for human body kinematics estimation and motion capture. IEEE Conference on Computer Vision and Pattern Recognition: Madison, WI: IEEE 2003:77–84 Cheung G, Baker S, Kanade T: Shape-from-silhouette of articulated objects and its use for human body kinematics estimation and motion capture. IEEE Conference on Computer Vision and Pattern Recognition: Madison, WI: IEEE 2003:77–84
15.
Zurück zum Zitat Freedman, B., Shpunt, A., Machline, M., Arieli, Y., 2010. Depth Mapping Using Projected Patterns. 20100118123. Prime Sense Ltd., United States. Freedman, B., Shpunt, A., Machline, M., Arieli, Y., 2010. Depth Mapping Using Projected Patterns. 20100118123. Prime Sense Ltd., United States.
16.
Zurück zum Zitat Shpunt, A., 2010. Depth Mapping Using Multi-beam Illumination. Prime Sense Ltd, United States. 20100020078. Shpunt, A., 2010. Depth Mapping Using Multi-beam Illumination. Prime Sense Ltd, United States. 20100020078.
17.
Zurück zum Zitat Spektor, E., Mor, Z., Rais, D., 2010. Integrated Processor for 3D Mapping. Prime Sense Ltd, United States. 20100007717. Spektor, E., Mor, Z., Rais, D., 2010. Integrated Processor for 3D Mapping. Prime Sense Ltd, United States. 20100007717.
18.
Zurück zum Zitat Dutta T. Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace. Appl Ergon. 2012; 43 (4): 645–9CrossRef Dutta T. Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace. Appl Ergon. 2012; 43 (4): 645–9CrossRef
19.
Zurück zum Zitat Clark RA, Pua YH, Fortin K, Ritchie C, Webster KE et al. Validity of the Microsoft Kinect for assessment of postural control. Gait Posture.2012; 36(3): 372–7CrossRef Clark RA, Pua YH, Fortin K, Ritchie C, Webster KE et al. Validity of the Microsoft Kinect for assessment of postural control. Gait Posture.2012; 36(3): 372–7CrossRef
20.
Zurück zum Zitat Gabel M, Gilad-Bachrach R, Renshaw E, Schuster A. Full body gait analysis with Kinect. Conf Proc IEEE Eng Med Biol Soc. 2012;2012: 1964–7. Gabel M, Gilad-Bachrach R, Renshaw E, Schuster A. Full body gait analysis with Kinect. Conf Proc IEEE Eng Med Biol Soc. 2012;2012: 1964–7.
21.
Zurück zum Zitat Lowes LP, Alfano LN, Yetter BA, Worthen-Chaudhari L, Hinchman W et al. Proof of concept of the ability of the kinect to quantify upper extremity function in dystrophinopathy. PLoS Curr. 2013 [Epub ahead of print] Lowes LP, Alfano LN, Yetter BA, Worthen-Chaudhari L, Hinchman W et al. Proof of concept of the ability of the kinect to quantify upper extremity function in dystrophinopathy. PLoS Curr. 2013 [Epub ahead of print]
22.
Zurück zum Zitat Bonnechère B, Jansen B, Salvia P, Bouzahouene H, Omelina L, Cornelis J, Rooze M, Van Sint Jan S. What are the current limits of the Kinect sensor? In: ICDVRAT. Laval. France; 2012. Bonnechère B, Jansen B, Salvia P, Bouzahouene H, Omelina L, Cornelis J, Rooze M, Van Sint Jan S. What are the current limits of the Kinect sensor? In: ICDVRAT. Laval. France; 2012.
23.
Zurück zum Zitat Van Sint Jan S, Salvia P, Hilal I, Sholukha V, Rooze M, Clapworthy G. Registration of 6- DOFs electrogoniometry and CT medical imaging for 3D joint modeling. J Biomech. 2002; 35(11): 1475–84.CrossRef Van Sint Jan S, Salvia P, Hilal I, Sholukha V, Rooze M, Clapworthy G. Registration of 6- DOFs electrogoniometry and CT medical imaging for 3D joint modeling. J Biomech. 2002; 35(11): 1475–84.CrossRef
24.
Zurück zum Zitat Sholukha V, Salvia P, Hilal I, Feipel V, Rooze M, Van Sint Jan S. Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach. Med Eng Phys. 2004; 26(3): 251–60.CrossRef Sholukha V, Salvia P, Hilal I, Feipel V, Rooze M, Van Sint Jan S. Calibration and validation of 6 DOFs instrumented spatial linkage for biomechanical applications. A practical approach. Med Eng Phys. 2004; 26(3): 251–60.CrossRef
25.
Zurück zum Zitat Sobczak S, Salvia P, Dugailly PM, Lefèvre P, Feipel V, Van Sint Jan S, Rooze M. Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy. J Orthop Surg Res. 2011; 6: 12CrossRef Sobczak S, Salvia P, Dugailly PM, Lefèvre P, Feipel V, Van Sint Jan S, Rooze M. Use of embedded strain gages for the in-vitro study of proximal tibial cancellous bone deformation during knee flexion-extension movement: development, reproducibility and preliminary results of feasibility after frontal low femoral osteotomy. J Orthop Surg Res. 2011; 6: 12CrossRef
26.
Zurück zum Zitat Dugailly PM, Sobczak S, Sholukha V, Van Sint Jan S, Salvia P, Feipel V, Rooze M. In vitro 3D-kinematics of the upper cervical spine: helical axis and simulation for axial rotation and flexion extension. Surg Radiol Anat. 2010; 32(2): 141–51.CrossRef Dugailly PM, Sobczak S, Sholukha V, Van Sint Jan S, Salvia P, Feipel V, Rooze M. In vitro 3D-kinematics of the upper cervical spine: helical axis and simulation for axial rotation and flexion extension. Surg Radiol Anat. 2010; 32(2): 141–51.CrossRef
27.
Zurück zum Zitat Van Sint Jan S, Taddei F, Leardini A, Snoeck O, Sholukha V, Moiseev F, Juszczyk M, Salvia P, Lufimpadio JL, Feipel V, Sobczak S, Rooze M, Viceconti M. Inegrated multiscale data collection for advanced modeling of human musculoskeletal system. 4th European Congress for Medical and Biomedical Engineering. Antwerp, Belgium. 2008 Van Sint Jan S, Taddei F, Leardini A, Snoeck O, Sholukha V, Moiseev F, Juszczyk M, Salvia P, Lufimpadio JL, Feipel V, Sobczak S, Rooze M, Viceconti M. Inegrated multiscale data collection for advanced modeling of human musculoskeletal system. 4th European Congress for Medical and Biomedical Engineering. Antwerp, Belgium. 2008
28.
Zurück zum Zitat Sholukha V, Leardini A, Salvia P, Rooze M, Van Sint Jan S. Double-step registration of in vivo stereophotogrammetry with both in vitro 6-DOFs electrogoniometry and CT medical imaging. J Biomech. 2006; 39(11): 2087–95.CrossRef Sholukha V, Leardini A, Salvia P, Rooze M, Van Sint Jan S. Double-step registration of in vivo stereophotogrammetry with both in vitro 6-DOFs electrogoniometry and CT medical imaging. J Biomech. 2006; 39(11): 2087–95.CrossRef
29.
Zurück zum Zitat Dugailly PM, Sobczak S, Moiseev F, Sholukha V, Salvia P, Feipel V, Rooze M, Van Sint Jan S. Musculoskeletal modeling of the suboccipital spine: kinematics analysis, muscle lengths, and muscle moment arms during axial rotation and flexion extension. Spine (Phila Pa 1976). 2011; 36(6): E413–22.CrossRef Dugailly PM, Sobczak S, Moiseev F, Sholukha V, Salvia P, Feipel V, Rooze M, Van Sint Jan S. Musculoskeletal modeling of the suboccipital spine: kinematics analysis, muscle lengths, and muscle moment arms during axial rotation and flexion extension. Spine (Phila Pa 1976). 2011; 36(6): E413–22.CrossRef
30.
Zurück zum Zitat Sholukha V, Van Sint Jan S, Snoeck O, Salvia P, Moiseev F, Rooze M. Prediction of joint center location by customizable multiple regressions: application to clavicle, scapula and humerus. J Biomech. 2009; 42(3):319–24.CrossRef Sholukha V, Van Sint Jan S, Snoeck O, Salvia P, Moiseev F, Rooze M. Prediction of joint center location by customizable multiple regressions: application to clavicle, scapula and humerus. J Biomech. 2009; 42(3):319–24.CrossRef
31.
Zurück zum Zitat Salvia P, Jan SV, Crouan A, Vanderkerken L, Moiseev F, Sholukha V, Mahieu C, Snoeck O, Rooze M. Precision of shoulder anatomical landmark calibration by two approaches: a CAST-like protocol and a new anatomical palpator method. Gait Posture. 2009; 29(4):587–91.CrossRef Salvia P, Jan SV, Crouan A, Vanderkerken L, Moiseev F, Sholukha V, Mahieu C, Snoeck O, Rooze M. Precision of shoulder anatomical landmark calibration by two approaches: a CAST-like protocol and a new anatomical palpator method. Gait Posture. 2009; 29(4):587–91.CrossRef
32.
Zurück zum Zitat Feipel V, Rooze M. Three-dimensional motion patterns of the carpal bones: an in vivo study using three-dimensional computed tomography and clinical applications. Surg Radiol Anat. 1999; 21(2): 125–31.CrossRef Feipel V, Rooze M. Three-dimensional motion patterns of the carpal bones: an in vivo study using three-dimensional computed tomography and clinical applications. Surg Radiol Anat. 1999; 21(2): 125–31.CrossRef
33.
Zurück zum Zitat Sobczak S, Rotsaert P, Vancabeke M, Van Sint Jan S, Salvia P, Feipel V. Effects of proximal row carpectomy on wrist biomechanics: a cadaveric study. Clin Biomech (Bristol, Avon). 2011; 26(7): 718–24.CrossRef Sobczak S, Rotsaert P, Vancabeke M, Van Sint Jan S, Salvia P, Feipel V. Effects of proximal row carpectomy on wrist biomechanics: a cadaveric study. Clin Biomech (Bristol, Avon). 2011; 26(7): 718–24.CrossRef
34.
Zurück zum Zitat Coupier J, Snoeck O, Mahieu C, Moiseev F, Salvia P, Chapman T, Sholukha V, Feipel V, Rooze M, Van Sint Jan S. 3D anatomical and biomechanical model of long finger. In: ISB2011. Brussels, Belgium; 2011. Coupier J, Snoeck O, Mahieu C, Moiseev F, Salvia P, Chapman T, Sholukha V, Feipel V, Rooze M, Van Sint Jan S. 3D anatomical and biomechanical model of long finger. In: ISB2011. Brussels, Belgium; 2011.
35.
Zurück zum Zitat Snoeck O, Lefevre P, Salvia P, Moiseev F, Rooze M, Van Sint Jan S. Biomechanical role of the lacertus fibrosus of the bicepsbrachialis muscle. ISB2011. Brussels, Belgium; 2011. Snoeck O, Lefevre P, Salvia P, Moiseev F, Rooze M, Van Sint Jan S. Biomechanical role of the lacertus fibrosus of the bicepsbrachialis muscle. ISB2011. Brussels, Belgium; 2011.
36.
Zurück zum Zitat Sholukha V, Chapman T, Salvia P, Moiseev F, Euran F, Rooze M, Van Sint Jan S. Femur shape prediction by multiple regression based on quadric surface fitting. J Biomech. 2011; 44(4): 712–8.CrossRef Sholukha V, Chapman T, Salvia P, Moiseev F, Euran F, Rooze M, Van Sint Jan S. Femur shape prediction by multiple regression based on quadric surface fitting. J Biomech. 2011; 44(4): 712–8.CrossRef
37.
Zurück zum Zitat Sobczak S, Dugailly PM, Baillon B, Lefevre P, Rooze M, Salvia P, Feipel V. In vitro biomechanical study of femoral torsion disorders: effect on femoro-tibial kinematics. Clin Biomech (Bristol, Avon). 2012; 27(10): 1011–6.CrossRef Sobczak S, Dugailly PM, Baillon B, Lefevre P, Rooze M, Salvia P, Feipel V. In vitro biomechanical study of femoral torsion disorders: effect on femoro-tibial kinematics. Clin Biomech (Bristol, Avon). 2012; 27(10): 1011–6.CrossRef
38.
Zurück zum Zitat Sobczak S, Dugailly PM, Feipel V, Baillon B, Rooze M, Salvia P, Van Sint Jan S. In vitro biomechanical study of femoral torsion disorders: effect on moment arms of thigh muscles. Clin Biomech (Bristol, Avon). 2013; 28(2): 187–92.CrossRef Sobczak S, Dugailly PM, Feipel V, Baillon B, Rooze M, Salvia P, Van Sint Jan S. In vitro biomechanical study of femoral torsion disorders: effect on moment arms of thigh muscles. Clin Biomech (Bristol, Avon). 2013; 28(2): 187–92.CrossRef
39.
Zurück zum Zitat Van Sint Jan S, Salvia P, Feipel V, Sobzack S, Rooze M, Sholukha V. In vivo registration of both electrogoniometry and medical imaging: development and application on the ankle joint complex. IEEE Trans Biomed Eng. 2006; 53(4): 759–62.CrossRef Van Sint Jan S, Salvia P, Feipel V, Sobzack S, Rooze M, Sholukha V. In vivo registration of both electrogoniometry and medical imaging: development and application on the ankle joint complex. IEEE Trans Biomed Eng. 2006; 53(4): 759–62.CrossRef
40.
Zurück zum Zitat Moiseev F, Sholukha V, Salvia P, Rooze M, Van Sint Jan S. Automated template based registration of heterogeneous data on human musculoskeletal system. In: ISB2011. Brussels, Belgium; 2011. Moiseev F, Sholukha V, Salvia P, Rooze M, Van Sint Jan S. Automated template based registration of heterogeneous data on human musculoskeletal system. In: ISB2011. Brussels, Belgium; 2011.
41.
Zurück zum Zitat van der Sluijs JA, van Doorn-Loogman MH, Ritt MJ, Wuisman PI. Interobserver reliability of the Mallet score. J Pediatr Orthop B. 2006; 15(5):324–7CrossRef van der Sluijs JA, van Doorn-Loogman MH, Ritt MJ, Wuisman PI. Interobserver reliability of the Mallet score. J Pediatr Orthop B. 2006; 15(5):324–7CrossRef
42.
Zurück zum Zitat Clark RA, Pua YH, Bryant AL, Hunt MA. Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining. Gait Posture. 2013 [Epub ahead of print] Clark RA, Pua YH, Bryant AL, Hunt MA. Validity of the Microsoft Kinect for providing lateral trunk lean feedback during gait retraining. Gait Posture. 2013 [Epub ahead of print]
43.
Zurück zum Zitat Lowes LP, Alfano LN, Yetter BA, Worthen-Chaudhari L, Hinchman W et al. Proof of concept of the ability of the kinect to quantify upper extremity function in dystrophinopathy. PLoS Curr. 2013 [Epub ahead of print] Lowes LP, Alfano LN, Yetter BA, Worthen-Chaudhari L, Hinchman W et al. Proof of concept of the ability of the kinect to quantify upper extremity function in dystrophinopathy. PLoS Curr. 2013 [Epub ahead of print]
44.
Zurück zum Zitat Guerrero C, Uribe-Quevedo A. Kinect-based posture tracking for correcting positions during exercise. Stud Health Technol Inform. 2013; 184: 158–60. Guerrero C, Uribe-Quevedo A. Kinect-based posture tracking for correcting positions during exercise. Stud Health Technol Inform. 2013; 184: 158–60.
45.
Zurück zum Zitat Malouin F, Richards CL, McFadyen B et al. New perspectives of locomotor rehabilitation after stroke. Med Sci (Paris). 2003; 19 (10): 994–8CrossRef Malouin F, Richards CL, McFadyen B et al. New perspectives of locomotor rehabilitation after stroke. Med Sci (Paris). 2003; 19 (10): 994–8CrossRef
46.
Zurück zum Zitat Krautwurst BK, Wolf SI, Heitzmann DW, Gantz S, Braatz F, Dreher T. The influence of hip abductor weakness on frontal plane motion of the trunk and pelvis in patients with cerebral palsy. Res Dev Disabil. 2013; 34(4): 1198–203.CrossRef Krautwurst BK, Wolf SI, Heitzmann DW, Gantz S, Braatz F, Dreher T. The influence of hip abductor weakness on frontal plane motion of the trunk and pelvis in patients with cerebral palsy. Res Dev Disabil. 2013; 34(4): 1198–203.CrossRef
47.
Zurück zum Zitat Brashear A, Elovic E. Spasticity: diagnosis and management. New York: Demos Medical, 2011. Brashear A, Elovic E. Spasticity: diagnosis and management. New York: Demos Medical, 2011.
Metadaten
Titel
From KinectTM to anatomically-correct motion modelling: Preliminary results for human application.
verfasst von
B. Bonnechère
V. Sholukha
F. Moiseev
M. Rooze
Jan S. Van Sint
Copyright-Jahr
2013
Verlag
Springer Fachmedien Wiesbaden
DOI
https://doi.org/10.1007/978-3-658-02897-8_2