Skip to main content
Log in

A themogravimetric analysis for poly(3-hydroxybutyrate) quantification

  • Published:
Biotechnology Techniques

Summary

A simple and quick thermogravimetric analysis method has been suggested for poly(3-hydroxybutyrate) [PHB] quantification. During the analysis, a rapid thermal degradation of PHB occurred in the range of 250 to 320 °C. From the gravimetric change during the thermal degradation, we could quantify PHB contents of various samples. Due to the simultaneous thermal degradation of cellular materials, the PHB contents were estimated slightly higher than those by gas chromatographic analysis. We have proposed a way to compensate for such errors using a linear correlation to allow accurate determination of PHB contents.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Braunegg, G., Sonnleitner, B., and Lafferty, R. M. (1978). Eur. J. Appl. Microbiol. Biotechnol. 6, 29–37.

    Google Scholar 

  • Doi, Y. (1990). Microbial polyesters. VCH, New York.

    Google Scholar 

  • Hahn, S. K., Chang, Y. K., Lee, S. Y. (1995). Appl Environ. Microbiol. 61:34–39.

    Google Scholar 

  • Holmes, P. A. (1985). Phys. Technol. 16: 32–36.

    Google Scholar 

  • Huijberts, G. N. M., Hetty van der Wal, Wilkinson, C., and Eggink, G. (1995). Biotechnol. Techniques, 8:187–192.

    Google Scholar 

  • Kim, B. S., Lee, S. C., Lee, S. Y., Chang, H. N., Chang, Y. K., and Woo, S. I. (1994). Biotechnol. Bioeng. 43:892–898.

    Google Scholar 

  • Lee, S. Y., Chang, H. N., and Chang, Y. K. (1994b). Ann. NY Acad. Sci. 721:43–53.

    Google Scholar 

  • Lee, S. Y., Yim, K. S., Chang, H. N., and Chang, Y. K. (1994a). J. Biotechnol. 32:203–211.

    Google Scholar 

  • Lowry, O. H., Rosebrough, N. J., Farr, A. L., and Randall, R. J. (1951). J. Biol. Chem. 193, 265–275.

    Google Scholar 

  • Morikawa, H. and Marchessault, R. H. (1981). Can. J. Chem. 59:2306–2313.

    Google Scholar 

  • Nickerson, K. W. (1982). Appl. Environ. Microbiol. 43:1208~1209.

    Google Scholar 

  • Reiner, E. (1965) Nature 206:1272.

    Google Scholar 

  • Ward, A. C. and Dawes, E. A. (1973). Anal. Biochem. 52:607~613.

    Google Scholar 

  • Williamson, D. H. and Wilkinson, J. F. (1958). J. Gen. Microbiol. 19:198~209.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hahn, S.K., Chang, Y.K. A themogravimetric analysis for poly(3-hydroxybutyrate) quantification. Biotechnol Tech 9, 873–878 (1995). https://doi.org/10.1007/BF00158539

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00158539

Keywords

Navigation