Abstract
Particle image velocimetry incorporates a process by which an image of a flow field, bearing double images of seeding particles, is analyzed in small regions called “interrogation spots.” Each spot is imaged onto a photodetector array whose digitized output is evaluated computationally using the auto-correlation technique. This paper examines the effects of resolving the spot using arrays of various resolutions, motivated primarily by a gain in speed. For this purpose, two specially created test photographs representing (i) uniform flow and (ii) solid body rotation, were interrogated using array sizes ranging from 32 × 32 to 256 × 256. Each reduction in resolution by a factor of two gains a factor of four in interrogation speed, but this benefit is counteracted by a loss in accuracy. The particle image diameter strongly influences accuracy through two distinct error mechanisms. When the particle image is small compared to the pixel size, mean bias error becomes significant due to finite numerical resolution of the correlation function. Conversely, when the particle image is large, random error due to irregularities in the electronic images predominates. The optimum image size, therefore, lies not at either extreme but at an intermediate value such that the particle image is small in an absolute sense, and yet large relative to the pixel size.
Similar content being viewed by others
References
Adrian, R. J. 1988: Statistical properties of particle image velocimetry measurements in turbulent flow. Laser Anemometry in Fluid Mechanics, Vol. III, Lisbon: Ladoan — Instituto Superior Técnico, 115–129
Adrian, R. J. 1991: Particle-imaging techniques for experimental fluid mechanics. Ann. Rev. Fluid Mech 23, 261–304
Bjorkquist, D. J. 1990: Particle image velocimetry analysis system. Proc. Fifth Intl. Symp. on Applications of Laser Anemometry to Fluid Mechanics, Lisbon, Portugal, 12.1
Keane, R. D. 1991: Private communication
Keane, R. D.; Adrian, R. J. 1990: Optimization of particle image velocimeters. Part I: Double pulsed systems. Meas. Sci. Technol. 1, 1202–1215
Landreth, C. C.; Adrian, R. J. 1988: Measurement and refinement of velocity data using high image density analysis in particle image velocimetry. Applications of Laser Anemometry to Fluid Mechanics (Eds.: Adrian, R. J., Asanuma, T., Durão, D. F. G., Durst, F., Whitelaw, J. H.). Berlin Heidelberg New York: Springer, pp 484–497
Liu, Z.-C.; Landreth, C. C.; Adrian, R. J.; Hanratty, T. J. 1991: High resolution measurement of turbulent structure in a channel with particle image velocimetry. Exp. Fluids 10, 301–312
Westerweel, J.; Nieuwstadt, F. T. M. 1990: Measurement of dynamics of coherent flow structures using particle image velocimetry. Proc. Fifth Intl. Symp. on Applications of Laser Anemometry to Fluid Mechanics, Lisbon, 18.3
Willert, C. E.; Gharib, M. 1991: Digital particle image velocimetry. Exp. Fluids 10, 181–193
Author information
Authors and Affiliations
Additional information
A version of this paper was presented at the 12th Symposium on Turbulence, University of Missouri-Rolla, 24–26 September 1990
Rights and permissions
About this article
Cite this article
Prasad, A.K., Adrian, R.J., Landreth, C.C. et al. Effect of resolution on the speed and accuracy of particle image velocimetry interrogation. Experiments in Fluids 13, 105–116 (1992). https://doi.org/10.1007/BF00218156
Received: