Abstract
The development of a completely biodegradable composite artificial tendon prosthesis that mimics the structure and stress-strain response of natural tendon is presented. The artificial tendon is a composite of water-swollen poly(2-hydroxyethylmethacrylate)/poly(caprolactone) blend hydrogel matrix reinforced with poly(lactic acid) fibres.
Similar content being viewed by others
References
C. HENZE and L. MAYER,Surg. Gyn. Obstet. 19 (1914) 10.
E. BAER, A. HILTNER and B. FRIEDMAN,Mekhanika Polimerov 6 (1975) 1051.
W. SOUTHMAYD and M. HOFFMAN, “Sports health. The complete book of athletic injuries” (Putnam, New York, 1981).
S. TROP, R. ARRIDGE, C. ARMENIADES and E. BAER,Colston Papers 26 (1975) 197.
W. HERRICK, H. KINSBURY and D. LOU,J. Biomed. Mater. Res. 12 (1978) 877.
G. BARNES and D. PINDER, ibid.7 (1974) 35.
F. PARTINGTON and G. WOOD,Biochim. Biophys. Acta 69 (1963) 485.
M. ABRAHAMS,Med. Biol. Engng 5 (1967) 433.
W. DALE and E. BAER,J. Mater. Sci. 9 (1974) 369.
M. SANCHEZ DE LA ASUNCION, J. L. GOMEZ RIBELLES and M. MONLEON PRADAS,J. Mater. Sci. Lett. 8 (1989) 263.
J. KASTELIC, A. GALESKI and E. BAER,Conn. Tissue Res. 6 (1978) 11.
A. CRONKITE,Anat. Rec. 64 (1936) 173.
R. KENEDI, T. GIBSON, J. EVANS and J. BARBENEL,Phys. Med. Biol. 20 (1975) 699.
D. GIBBONS, in “CRC handbook of engineering in medicine and biology”, edited by D. Fleming and B. Feinberg (CRC Press, Cleveland, OH, 1976) pp. 253.
J. KASTELIC and E. BAER, in “The mechanical properties of biological materials”, edited by J. Vincent and J. Currey (Cambridge University Press, 1980) pp. 397.
A. VIIDIK, in “Handbook of bioengineering”, edited by R. Skalak and S. Chien (McGraw-Hill, New York, 1987) ch. 6.
H. LEE and K. NEVILLE, in “Handbook of biomedical plastics” (Pasadena Technical Press, Pasadena, CA, 1971) ch. 12.
J. GARLOCK,Ann. Surg. 85 (1927) 92.
T. SKOOG and B.H. PERSSON,Plast. Recon. Surg. 13 (1954) 384.
A. POTENZA,J. Bone Jt Surg. 45A (1963) 1217.
R. GELBERMAN, J. VANDE BERG, G. LUNDBORG and W. AKESON, ibid.65A (1983) 70.
R. SALISBURY, D. McKEEL, B. PRUITT, A. MASON Jr, N. PALERMO and C. WADE,J. Biomed. Mater. Res. Symp. 5 (1974) 175.
R. BEASLEY, in “Hand injuries”, (W. B. Saunders Co., Philadelphia, PA, 1981) ch. 7.
E. PEACOCK Jr, in “Tendon surgery in the hand”, edited by J. Hunteret al. (C. V. Mosby Co., St Louis, MO, 1987) ch. 6.
W. LINDSAY, in “Tendon surgery in the hand”, edited by J. Hunteret al. (C. V. Mosby Co., St Louis, MO, 1987) ch. 7.
G. LUNDBORG and F. RAND, in “Tendon surgery in the hand”, edited by J. Hunteret al. (C. V. Mosby Co., St Louis, MO, 1987) ch. 8.
S. SCHEPEL, in “Tendon surgery in the hand”, edited by J. Hunteret al. (C. V. Mosby Co., St Louis, MO, 1987) ch. 9.
R. GONZALEZ,Surgery 26 (1949) 181.
Idem., Plast. Recon. Surg. 23 (1959) 535.
T. WHEELDON,J. Bone Jt Surg. 21 (1939) 393.
A. FARMER,Plast. Recon. Surg. 2 (1947) 207.
G. McKEE,Lancet 1 (1945) 659.
E. WECKESSER, B. SHAW, G. SPEARS and P. SHEA,Surgery 25 (1949) 361.
F. ASHLEY, R. STONE, M. ARTIEDA, J. SYVERUD, J. EDWARDS, R. SLOAN and S. MONNEY,Plast. Recon. Surg. 23 (1959) 526.
J. HUNTER, in “Tendon surgery in the hand”, edited by J. Hunteret al. (C. V. Mosby Co., St Louis, MO, 1987) ch. 38.
Idem., Amer. J. Surg. 109 (1965) 325.
J. HUNTER, C. STEINDEL, R. SALISBURY and D. HUGHES,J. Biomed. Mater. Res. Symp. 5 (1974) 155.
J. HUNTER, D. SUBIN, F. MINKOW and J. KONIKOFF ibid.8 (1974) 163.
J. HUNTER,J. Hand Surg. 8 (1983) 789.
T. SARKIN,Brit. J. Surg. 44 (1956) 232.
R. WILLIAMS and S. AUGUST,Amer. J. Surg. 107 (1964) 913.
K. BADER and J. CURTIN,Arch. Surg. 97 (1968) 406.
C. WADE, J. OUELLETTE, J. HODGE and J. URBAN,J. Biomed. Mater. Res. Symp. 6 (1975) 149.
R. KING, H. DUNN and K. BOLSTAD ibid.16 (1975) 157.
R. KING, G. McKENNA and W. STATTON,J. Appl. Polym. Sci.: Appl. Polym. Symp. 31 (1977) 335.
H. AMSTUTZ, W. COULSON and E. DAVIS,J. Biomed. Mater. Res. 10 (1976) 47.
P. WALKER, H. AMSTUTZ and M. RUBINFELD, ibid.10 (1976) 61.
H. ALEXANDER, I. STRAUCHLER, A. WEISS, C. MAYOTT and J. PARSONS,Abstr. Papers 10th Ann. Int. Biomater. Symp., San Antonio, TX (Society of Biomaterials, 1978).
H. ALEXANDER, A. WEISS, J. PARSONS, I. STRAUCHLER and S. CORCORAN,Trans. NEB Bioeng Conf. 7 (1979) 400.
H. ALEXANDER, A. WEISS, J. PARSONS, I. STRAUCHLER and O. GONA,Abstr. Papers 25th Ann. Meet. Orthop. Res. Soc., San Francisco, CA, 1979.
J. ARAGONA, J. PARSONS, H. ALEXANDER and A. WEISS,Clin. Orthop. Rel. Res. 160 (1981) 268.
J. PARSONS, H. ALEXANDER and A. WEISS, in “Biocompatible polymers, metals and composites”, edited by M. Szycher (Technomic, Lancaster, PA, 1983).
C. MIGLIARESI and L. NICOLAIS,Int. J. Art. Org. 3 (1980) 114.
C. MIGLIARESI, J. KOLARIK, M. STOL and L. NICOLAIS, in “Reology”, Vol. 3, edited by G. Astaritaet al. (Plenum Press, New York, 1980).
D. RONCA, G. BERGAMO, G. IOLASCON, C. MIGLIARESI, L. AMBROSIO, A. PAPPARELLA and F. BALDI,Min. Ort. Traum. 38 (1987) 807.
M. STOL, M. TOLAR and M. ADAM,Biomaterials 6 (1985) 193.
I. CIFKOVÁ, M. STOL, R. HOLUSA and M. ADAM, ibid.8 (1987) 30.
P. DAVIS, L. NICOLAIS, L. AMBROSIO and S. HUANG,J. Bio. Comp. Polym. 3 (1988) 205.
N. ROGERS,Med. Ann. Columbia 39 (1970) 411.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Davis, P.A., Huang, S.J., Ambrosio, L. et al. A biodegradable composite artificial tendon. J Mater Sci: Mater Med 3, 359–364 (1992). https://doi.org/10.1007/BF00705368
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00705368