Skip to main content
Log in

Visibility of exit signs in clear and smoky conditions

  • Technical Note
  • Published:
Fire Technology Aims and scope Submit manuscript

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  1. Australian Standards Association,Emergency Evacuation Lighting in Buildings: Part 1 — Installation Requirements, S 2293, Part 1 (1983).

  2. Beyreis, J. R., and Castino, T. G., “Safety in Sight,”Labdata (Winter 1974), pp. 14–19

  3. Bukowski, R. W.,Smoke Measurements in Large- and Small-Scale Fire Testing, NBSIR 78-1502, National Bureau of Standards (1978).

  4. Clark, F. R. S., Rea, M. S., and Ouellette, M. J, “Visibility of Exit Signs Through Smoke,”Proceedings of the International Conference on Building Use and Safety Technology (1985), PP. 75–80.

  5. Collins, B. L., and Lerner, N. D.,An Evaluation of Exit Symbol Visibility, NBSIR 83-2675, National Bureau of Standards (1983).

  6. Commission Internationale de l'Eclairage (CIE),Guide on the Emergency Lighting of Building Interiors, CIE No. 49 (TC4-1), CIE, Paris (1981).

    Google Scholar 

  7. Cooper, L. Y., “Compartment Fire-Generated Environment and Smoke Filling,” SFPE Engineering Handbook (1988), pp. 2–119.

  8. Demaree, J.,Examination of Aircraft Interior Emergency Lighting in a Postcrash Fire Environment, DOT/FAA/CT-82/55, U.S. Department of Transportation, Federal Aviation Administration (1982).

  9. Jin, T., and Yamada, T., “Irritating Effects of Fire Smoke on Visibility,” Fire Science and Technology, Vol. 5 (1986), pp. 79–90.

    Google Scholar 

  10. Kaufman, J. E., and Christensen, J. F., Eds.,IES Lighting Handbook; Application Volume, IESNA:246–250, New York (1987).

    Google Scholar 

  11. Keating, J. P.,A Feasibility Study on the Placement of Egress Signage at Lower Positions than Is Currently Common, Report to the California State Legislature by the Office of the State Fire Marshal in Response to SCR 32, (1984).

  12. National Fire Protection Association, NFPA 101,The Life Safety Code, Quincy, MA (1988).

  13. National Research Council,National Building Code of Canada, Canada (1990).

  14. Ouellette, M. J., “Design Parameters for More Visible Exit Signs in Smoke,”Proceedings of the National Lighting Conference, Cambridge, U.K. (1988).

  15. Ouellette, M. J., “Exit Signs in Smoke: Design Parameters for Greater Visibility,”Lighting Research and Technology Vol. 20 (1988), pp. 155–160.

    Google Scholar 

  16. Rasmussen, P. G., Garner, J. D., Blethros J. G., and Lowrey, D. L.,Readability of Self-Illuminated Signs in a Smoke-Obscured Environment, FAA-AM-79-22, FAA-ARD-79-108, U.S. Department of Transportation, Federal Aviation Administration (1979).

  17. Rea, M. S., “How Good Are Emergency Lighting Systems?,”LD +A, Vol. 15, No. 9 (1985), pp. 26–27.

    Google Scholar 

  18. Rea, M. S., Clark, F. R. S., and Ouellette, M. J.,Photometric and Psychophysical Measurements of Exit Signs Through Smoke, DBR-1291, NRCC 24627, National Research Council Canada, Division of Building Research (1985).

  19. Schooley, L. C., and Reagan, J. A., “Visibility and Legibility of Exit Signs, Part II: Experimental Results,”Journal of the IES Vol. 10, No. 1 (1980), pp. 29–32.

    Google Scholar 

  20. Underwriters Laboratories (UL) Inc., “Emergency Lighting and Power Equipment,” UL 924,Exit Fixture and Exit Light Visibility (1989).

  21. Underwriters Laboratories Inc.,Report of Determination of Shape, Size, and Visibility of Directional Arrows for Exit Signs, Report No. 1988-1, Subject 924), Underwriters Laboratories, Santa Clara, CA (1988).

    Google Scholar 

  22. Webber, G. M. B., “Emergency Lighting Recommendations,”Proceedings of the International Conference on Building Use and Safety Technology (1985).

  23. Wilson, I., “The Effectiveness of Exit Signs in Smoke,”Lighting in Australia (1990), pp. 14–19.

  24. Alpert, R. L., “Calculation of Response Time of Ceiling-Mounted Fire Detectors,” Fire Technology (1972), pp. 181–195.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Collins, B.L., Dahir, M.S. & Madrzykowski, D. Visibility of exit signs in clear and smoky conditions. Fire Technol 29, 154–182 (1993). https://doi.org/10.1007/BF01038537

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01038537

Keywords

Navigation