Design, implementation and evaluation of amicrocomputer-based portable arrhythmia monitor

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The design of a portable, battery-operated microcomputer-based monitor for ambulatory ECG recording and analysis is described. Designed for real-time cardiac arrhythmia analysis, it is suitable for use on ambulator, patients for several weeks, and is about the size and weight of a Holter recorder. The device differs from a Holter recorder in that is does not store normal complexes but recognises and alarms on significant arrhythmias. It sotres 16 s of the arrhythmic event, which it can transmit by telephone to a central receiving station for immediate appraisal by a cardiologist. The monitor uses a CMOS microcomputer and has 2kbytes of program memory and 2kbytes of data memory. The arrhythmia monitor program recognises tachycardia, bradycardia, asystole, dropped beats, and PVCs. The alarm limits are physician programmable. The performance of the monitor was evaluated with standard annotated ECG tapes provided by MIT/BIH. This device should be useful for applications such as antiarrhythmic drug studies, for pacemaker and postsurgery evaluations, and for detecting premonitory as well as life-threatening arrhythmias.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abenstein, J. P. andThakor, N. V. (1981) A detailed design example—ambulatory ECG monitoring. InDesign of microcomputer-based medical instrumentation.Tompkins, W. J. andWebster, J. G. (Eds.), Prentice-Hall, Englewood Cliffs, NJ, Chap. 6.

    Google Scholar 

  • Fostik, M., Conway, T., Dwinell, R. andSinger, J. (1980) Lowpower electrocardiographic data-acquisition module for microprocessor systems.Med. & Biol. Eng. & Comput.,18, 95–103.

    Article  Google Scholar 

  • Holter, N. J. (1961) New methods for heart studies: continuous electrocardiography of active subjects.Science,134, 1214–1220.

    Google Scholar 

  • Mark, R. G., Moody, G. B., Olson, W. H., Peterson, S. K., Schluter, P. S. andWalters, J. B. Jr. (1979) Real-time ambulatory arrhythmia analysis with a microcomputer.Proc. Comput. Cardiol., 317–375.

  • Mark, R. G. (1980) MIT/BIH arrhythmia database—tape directory and format specification. Document BMEC TR010 Mass. Inst. Tech.

  • Mueller, W. C. (1978) Arrhythmia detection for an ambulatory ECG monitor.Biomed. Sciences Instrum.,14, 81–85.

    Google Scholar 

  • Oliver, G. C., Kleiger, R. E., Krone, R. J., Martin, T. F., Miller, J. P., Nolle, F. M. andCox, J. R. Jr. (1974) Applications of high speed analysis of ambulatory electrocardiograms.Proc. Comput. Cardiol., 43–54.

  • Oliver, G. C., Ripley, K. L., Miller, J. P. andMartin, T. F. (1977) A critical review of computer arrhythmia detectors. InComputer electrocardiography: current status and future promise,Pordy,L. (Ed.), Futura, Mt. Kisco, NY.

    Google Scholar 

  • Ripley, K. L. andMurray, A. (1980)Introduction to automated arrhythmia detection. IEEE Comput. Soc., Long Beach, Ca.

    Google Scholar 

  • Ripley, K. L. andOliver, G. C. (1975) Development of an ECG database for arrhythmia detectors.Proc. Comput. Cardiol., 27–32.

  • Thakor, N. V. (1978) Reliable R-wave detection from ambulatory subjects.Biomed. Sciences Instrum.,14, 67–72.

    Google Scholar 

  • Thakor, N. V., Webster, J. G. andTompkins, W. J. (1980) Optimal QRS filter.IEEE Front. Eng. Health Care, 190–195.

  • Thakor, N. V. (1981) Design, implementation and evaluation of a microcomputer-based arrhythmia monitor. Ph.D. Dissertation, University of Wisconsin.

  • Thakor, N. V. andWebster, J. G. (1982) Design and evaluation of QRS and noise detectors for ambulatory e.c.g. monitors.Med. & Biol. Eng. & Comput.,20, 709–714.

    Article  Google Scholar 

  • Thakor, N. V., Webster, J. G. andTompkins, W. J. (1982) A battery-powered digital modem for telephone transmission of ECG data.IEEE Trans. BME-29, 355–359.

    Google Scholar 

  • Thakor, N. V., Webster, J. G. andTompkins, W. J. (1983) Optimal QRS detector.Med. & Biol. Eng. & Comput.,21, 343–350.

    Google Scholar 

  • Tompkins, W. J. (1978) A portable microcomputer-based system for biomedical applications.Biomed. Science Instrum.,14, 61–64.

    Google Scholar 

  • Walters, J. B. Jr. (1976) Microprocessor based ambulatory EKG monitor. Proc. Annual Conf. Eng. Med. Biol.18, 255.

    Google Scholar 

  • Webster, J. G. (1978) An intelligent monitor for ambulatory ECGs.Biomed. Sciences Instrum.,14, 55–60.

    Google Scholar 

  • Yuen, S. K. (1976) CARDALERT: a portable battery operated, real-time arrhythmia detector and alarm system. Ph.D. Dissertation, Dept. Elect. Eng., University of Illinois.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thakor, N.V., Webster, J.G. & Tompkins, W.J. Design, implementation and evaluation of amicrocomputer-based portable arrhythmia monitor. Med. Biol. Eng. Comput. 22, 151–159 (1984). https://doi.org/10.1007/BF02446819

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446819

Keywords

Navigation