Introduction

The oral route is the most convenient means for the administration of most protein-based functional ingredients. However, there are some obstacles for overcoming due to their susceptibility to digestive enzymes in the gastrointestinal (GI) tract and limited ability to transport across the intestinal epithelial barrier [1, 2]. Therefore, the development and utilization of delivery systems have attracted great interests in the past decade, which could protect protein from the GI environment and achieve controlled release.

The colon has been considered as an ideal site for protein and peptide absorption [3]. In the design of colon-specific delivery system of water-soluble and active ingredients, natural polysaccharides, such as pectin, alginate, chitosan, cellulose, and starch, are being preferred to their synthetic counterparts. Among these polysaccharides, gellan gum is a linear anionic polysaccharide obtained from the exocellular secretion of the microorganism, Pseudomonas elodea [4]. Except for low toxicity and biodegradability, gellan gum is very stable over the wide pH range of 2–10 [5] and insensitive to pectinase, amylase, cellulase, papain, and lipase [6], whereas it undergoes significant degradation in the presence of galactomannanase which in turn facilitates the core material release from beads in the colon fluid, thus approving the suitability of gellan gum as a carrier for controlled colonic delivery [7].

However, these natural polymers exhibit some limitations, such as uncontrolled hydration rate which could be reduced by modifying the solubility by cross-linking or complexation [2]. The commercially deacylated gellan gum (low acyl form) has a stronger affinity for divalent cations and its gel-forming ability at concentrations remarkably lower than other hydrocolloids such as alginate and pectin [8]. Due to its ability to form hydrogel in the presence of divalent cations, especially Ca2+ ions, gellan gum has been investigated for the controlled release of some drugs such as in situ gelling systems for ocular [9] and nasal [10] delivery. Although calcium-gellan gum beads are promising for colonic-specific delivery, the burst release is serious and sustained-release effect is very poor [4]. In order to address the problem, Maiti et al. [11] developed a system through ionotropic gelation of gellan with Al3+ ions and covalent cross-linking with glutaraldehyde, whereas the application of toxic cross-linker is not suitable in functional food and the drying process is neglected, which is crucial to the remains of gel structure.

Polyelectrolyte complex formation between macromolecules is another approach which is helpful to bring about improvement in the quality of the above-discussed hydrocolloid-based bead systems. Polyelectrolyte complexes of cationic polymer chitosan and anionic polymers have been extensively reported in the literature. The applicability of chitosan-gellan gum polyelectrolyte complex beads with controlled release properties has been explored [12, 13]. However, the beads prepared with gellan gum and chitosan for encapsulation of metronidazole exhibited poor encapsulation efficiency, and almost all the drugs released within 2 h in simulated gastric fluid [12].

Although some efforts have been put in understanding the sustained drug release properties of calcium-gellan gum beads or chitosan-gellan gum beads, very few studies have been found describing the formation of protein-loaded chitosan-calcium-gellan gum system. As far as we know, there is no article on one-step formation of chitosan-gellan gum beads with calcium for functional ingredient delivery. This has prompted us to make an attempt to explore the possibility of developing chitosan-calcium-gellan gum beads by one-step process without any other toxic cross-linking agents and to study their potential for oral controlled delivery of water-soluble protein–based functional ingredients.

In this study, chitosan-calcium-gellan gum beads incorporating a model protein (bovine serum albumin, BSA) was prepared by the combination of ionotropic gelation and polyelectrolyte complexation. Various possible physicochemical interactions among formulation components and physical state of albumin in beads were evaluated through Fourier transform infrared spectroscopy, differential scanning calorimetry, and X-ray diffraction analysis. Additionally, the swelling behavior and protein release profile were investigated by mimicking in vitro pH conditions of the gastrointestinal tract.

Materials and methods

Materials

Low acyl gellan gum (Kelcogel, food grade) was obtained from George Food Industries Co., Ltd. (Shanghai, China). Calcium chloride, bovine serum albumin (BSA), and Bradford reagent were purchased from Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Partially deacetylated chitosan (approximately 93 %) with average molecular weight of 100, 000 was acquired from Jinhu Crust product Co., Ltd. (Shandong, China). All other chemicals and reagents used were of analytical grade.

Methods

Preparation of the chitosan-calcium-gellan gum beads

Gellan gum was dispersed in deionized water and then heated to 90 °C with agitation for about 5 min until total dissolution. Core material BSA (50 % of the dry mass of gellan gum) was then dispersed in the gellan gum solution at around 40 °C with continuous stirring until a uniform dispersion was obtained [14]. Chitosan solution was prepared by dissolving it with stirring in 3 % (v/v) acetic acid and mixed with calcium chloride. As the cross-linking solution, the mixed solution of calcium chloride and chitosan was adjusted to pH 3.5 by 0.2 mol/L NaOH, which would not affect gellan gum bead formation through ionotropic gelation. The pH of the cross-linking solution and release medium will affect the charge characteristics of chitosan and gellan gum. At pH 3.5, chitosan is a polycationic polysaccharide and gellan gum is a polyanionic polysaccharide. In this case, chitosan and gellan gum can form a dense polyelectrolyte composite film on the surface of beads under the electrostatic interactions, which could effectively reduce the permeability and the release rate of beads. The gellan gum beads were prepared by the combination of ionotropic gelation and polyelectrolyte complex according to the previous studies [15, 16] with some modification. Briefly, aliquots of gellan gum solution (4 mL) with BSA were extruded dropwise into the gently agitated cross-linking solution with the help of a 10-mL hypodermic syringe fitted with a 20-G needle from 5 cm distance at room temperature (25 °C) [17]. The beads were formed instantaneously and then cured for 10 min in chitosan-calcium chloride solution with mild agitation, separated by filtration, and washed thrice with deionized water to remove excess calcium chloride, albumin, and chitosan. The obtained beads were dried by freeze-drying (−50 °C, LGJ-10, Four-Ring Science Instru Co., Ltd, China) or oven-drying (37 °C, BGZ-146, Shanghai Boxun Industry & Commerce CO., Ltd, China) or vacuum-drying (−0.1 MPa, 37 °C, BZG-6020D, Shanghai Sumsung Experimental Instrument Co., Ltd, China) for 24–48 h and then kept in a desiccator. Different batches were prepared by varying the formulation parameters (Table 1). All batches were simultaneously prepared in triplicate.

Table 1 Composition of formulation design

Morphology determination

Morphological observation of surface and cross section of the beads was performed by using a scanning electron microscope (SEM; S-4800, Hitachi, Japan). Before observation, the beads were fixed or sectioned on an aluminum stub followed by coating with gold under vacuum to render them electrically conductive. The micrographs were recorded at an excitation voltage of 1.0 kV.

Fourier transform infrared spectroscopy

Fourier transform infrared (FTIR) spectra of some samples including chitosan, gellan gum-chitosan beads, gellan gum, calcium-gellan gum beads, chitosan-calcium-gellan gum beads, BSA, gellan gum, physical mixture of gellan gum and BSA (mass ratio of 2:1), BSA-loaded calcium-gellan gum beads, and BSA-loaded chitosan-calcium-gellan gum beads were recorded using a FTIR spectrophotometer (NICOLET NEXUS 470, Thermo Electron Corporation, USA). The samples were crushed with potassium bromide to make pellets. The FTIR spectra were scanned in the range of 400–4,000 cm−1, and the resolution was 4 cm−1.

Differential scanning calorimetry

The differential scanning calorimetry (DSC) measurements were taken using a differential scanning calorimeter (Pyris 1, Perkin-Elmer Corp., Norwalk, CT, USA). Each sample (1.0–4.0 mg) was accurately weighed into an aluminum pan and scanned in hermetically sealed conditions over the temperature range between 30 and 330 °C at a scanning rate of 10 °C/min. The characteristic peaks of exotherm and endotherm were recorded. All samples and an empty sealed aluminum pan as reference were kept at 30 °C for 1 min before scanning. Nitrogen was used for purging the sample holders at a flow rate of 20 mL/min. All tests were performed in duplicate.

X-ray diffraction studies (XRD)

Samples were filled into a sample holder and exposed to Cu Kα radiation in a X-ray powder diffractometer (D8, Bruker AXS, German). Each sample was scanned in a continuous mode at a scanning rate of 5°/min with the diffraction angle 2θ from 3° < 2θ < 60°.

Determination of encapsulation efficiency and loading capacity

The protein content in the beads was determined indirectly by measuring the concentration of BSA in the preparation medium and washing solutions by the Bradford method at 595 nm [1, 18], using a UV–visible spectrophotometer (UV-1600, Mapada Instruments Co., Ltd, China). The encapsulation efficiency (EE, %) and loading capacity (LC, %) were calculated according to the following equations:

$$ {\text{EE }}\left( \% \right) \, = \, [(W_{a} - W_{b} )/W_{a} ] \times 100 $$
$$ {\text{LC }}\left( \% \right) \, = \, \left[ {\left( {W_{a} - W_{b} } \right)/W} \right] \times 100 $$

where W a is the theoretical weight of protein (amounts of protein added into the system), W b is the weight of free protein, and W is the weight of the dried beads.

Swelling characteristics of beads

The swelling behaviors of beads were studied in simulated gastric fluid (SGF, pH 1.2 0.1 mol/L NaCl/HCl buffer solution), simulated small intestinal fluid (SIF, 0.05 mol/L phosphate-buffered saline, PBS, pH 6.8), and simulated colonic fluid (SCF, 0.05 mol/L phosphate-buffered saline, PBS, pH 7.4). Samples of known weight were consecutively dipped in 5 mL of SGF (0–2 h), SIF (2–5 h), and SCF (5–8 h) at 37 °C. The swollen beads were periodically removed from the swelling medium and weighed at appropriate intervals. The wet weight of the swollen beads was determined by blotting them with filter paper to remove moisture adhering to the surface, immediately. The swelling ratio (SR) of the beads was calculated using the following equation:

$$ {\text{SR}}\left( \% \right) \, = \, \left[ {\left( {W_{t} - W_{0} } \right)/W_{0} } \right] \times 100 $$

where W t is the weight of the swollen test sample at appropriate intervals and W 0 is the absolutely dried weight of beads [19].

The morphological change of beads during swelling in simulated gastrointestinal fluid was observed with an optical microscope (BX51/BX52, Olympus, Japan).

Assessment of in vitro albumin release

The in vitro BSA release profiles of beads were determined in order to mimic the GIT (i.e., 0–2 h in SGF, pH 1.2; 2–5 h in SIF, pH 6.8; 5–8 h in SCF, pH 7.4) from stomach to colon. The BSA-loaded beads were placed into 100-mL conical flask with 20 mL release medium and incubated at 37 ± 0.5 °C under shaking of 50 r/min [20]. At 30, 60, 120, 180, 240, 300, 360, 420, and 480 min, 0.3- or 0.5-mL aliquot was withdrawn and replenished with an equal volume of fresh dissolution medium. The BSA content in withdrawing samples was analyzed by Bradford method at 595 nm using a UV–Vis spectrophotometer (UV-1600, Mapada Instruments Co., Ltd, China). The release rate was calculated using the following equation:

$$ {\text{Release}}\,{\text{rate}}\,(\% ) = \tfrac{{C_{n} \times V + \sum\nolimits_{i = 0}^{n - 1} {C_{n - 1} \times V_{i} } }}{{W \times {\text{LC}}\% }} \times 100 $$

where C n is the concentration of BSA in the release medium when samples are taken for the nth time; V is the volume of release medium; V i is the volume of the sample before samples are taken for the nth time.

Albumin release kinetics

In order to describe the kinetics of albumin release from formulations, zero-order, first-order, Higuchi, and Korsmeyer–Peppas mathematical models were used. Korsmeyer–Peppas mathematical model was used to relate exponentially the albumin release to the elapsed time. It was calculated using the following equation:

$$ M_{t} /M_{\infty } = Kt^{n} $$

where M t /M is the fractional solute release at time t, K is a constant which incorporates the structural and geometric characteristics of the device, and n is diffusion exponent which suggests the mechanism of albumin release from spherical polymeric devices [11]. The adequacy of the delivery profiles to the mathematical models is based on the correlation coefficient value (r 2).

Statistical analysis

All experiments were performed in triplicate, and experimental data are expressed as mean ± standard error (SE). All statistical analyses were performed using SPSS 13.0 (SPSS Inc., USA). Effects of various parameters on the characteristics of beads were subjected to one-way ANOVA to determine the level of significance between various groups, including chitosan concentration, calcium chloride concentration, gellan gum concentration, and drying conditions. Statistical significance was set at p < 0.05.

Results and discussion

Encapsulation properties and morphology of beads

Generally, the encapsulation properties of the beads depended on the dissolution of BSA into the cross-linking solution. The isoelectric point of BSA is around 4.7, and pKa values of gellan gum and chitosan are 3.06 and 6.3, respectively. Beads were generated at pH 3.5 to ensure the maximum interaction between gellan gum and the protein. Under the electrostatic and ionotropic interactions, the beads were adequately formed and the protein was successfully immobilized, as confirmed by the high-efficiency parameter and loading capacity (EE and LC). The diffusion of BSA from beads might also be reduced by controlling the formulation of beads. It was found that the formulation variables showed an obvious influence on the EE and LC of the formulated beads (Table 2). The incorporation of chitosan led to greater encapsulation efficiency and loading capacity, whereas inappropriate concentration was not beneficial to the formation of dense polyelectrolyte complex membrane. Excessive calcium ion concentration would weaken the gel strength of gellan gum, which resulted in the lower EE and LC. Furthermore, the higher the concentration of gellan gum was, the slower the diffusion of BSA from gellan gum solution into the cross-linking solution was. Therefore, the beads had the highest EE (85.50 %) and LC (14.85 %) when the concentration of chitosan, calcium ion, and gellan gum were, respectively, 0.50 %, 0.25 mol/L, and 1.5 %.

Table 2 Release kinetic models, EE, and LC of the beads

After vacuum-drying, the surface morphology of BSA-loaded calcium-gellan gum beads and chitosan-calcium-gellan gum beads was significantly changed as Fig. 1a, c shown, both of which produced a serious volume phase transition from spherical to irregular ellipsoidal structure and had some roughness and folds on the surface of the beads. During the drying process, many cracks might exist on the surface of the beads. However, chitosan coating endowed the beads a relatively dense surface with less and smaller cracks compared with that of uncoated beads, which was believed to form harden composite membrane by the cross-linking between chitosan and calcium-gellan gum (Fig. 1b, d). Figure 1e showed a thin surface layer observed in the case of cross section of the chitosan-coated beads. This layer successfully evidenced the formation of the polyelectrolyte complex between chitosan and gellan gum on the bead surface.

Fig. 1
figure 1

Scanning electron micrographs of the surface of BSA-loaded chitosan-calcium-gellan gum bead (×100) (a), (×1,000) (b); the surface of BSA-loaded calcium-gellan gum bead (×100) (c), (×1,000) (d); cross section of BSA-loaded chitosan-calcium-gellan gum bead (×100) (e). Arrow indicates the thin surface layer

Evaluation of the polymer interaction and existence state of albumin in beads

In order to confirm the interaction involved in the formation of beads, the peak variations in pure gellan gum, chitosan, blank calcium-gellan gum beads, blank chitosan-gellan gum beads, and blank chitosan-calcium-gellan gum beads were examined by FT-IR (Fig. 2). In the case of pure gellan gum (Fig. 2c), the characteristic peaks were observed due to H-bonded O–H stretch vibration of hydroxyl groups (3,425 cm−1), C–H stretch vibration of CH2 group (2,931 cm−1), asymmetric carboxylate anion stretching (1,610 cm−1), symmetric carboxylate anion stretching (1,417 cm−1), and C–O stretching (1,033 cm−1). For calcium-gellan gum beads (Fig. 2d), the bands of symmetric carboxylate anion stretching and C–O stretching shifted to 1,459 and 1,037 cm−1, respectively. On the other hand, the asymmetric carboxylate anion stretching exhibited two new bands at 1,631.74 and 1,551.40 cm−1. It may be attributed to the ionic interaction between carboxylic groups of gellan gum and Ca2+ during the formulation of beads [21]. Pure chitosan (Fig. 2a) showed characteristic bands of amide (1,664 cm−1) and amine (1,590 cm−1). The FTIR spectra of chitosan-gellan gum beads (Fig. 2b) showed shifting of amide band to 1,607 cm−1 and amine to 1,560 cm−1. This shift in amine band indicated the change in environment of amine group through its interaction with carboxylate groups on gellan gum [22]. The spectrum of chitosan-calcium-gellan gum (Fig. 2e) was similar to that of calcium-gellan gum. Once this bead was coated with chitosan, the band at 1,551 cm−1 was intensified owing to NH2 and NH of chitosan in chitosan-calcium-gellan gum. The weakened absorption at 1,632 cm−1 indicated the presence of protonated amine group in chitosan [20], and the intensified protonation of most of gellan gum was proved by the changes at 1,632 and 1,460 cm−1 in chitosan-calcium-gellan gum spectra [23]. Therefore, the formation of chitosan-calcium-gellan gum beads was controlled by the combination of electrostatic and ionic interactions.

Fig. 2
figure 2

FTIR spectra of a chitosan; b gellan gum-chitosan beads; c gellan gum; d calcium-gellan gum beads; e chitosan-calcium-gellan gum beads

The main absorption bands of BSA were listed as follows (Fig. 3a): 1,655 and 1,539 cm−1, corresponding to the amide I band and the amide II band [24], respectively. The characteristic peaks of BSA might be observed in the case of physical mixture of gellan gum and BSA (Fig. 3c), while the peak of amide I shifted from 1,655 to 1,652 cm−1 because of the overlapping between BSA and gellan gum. However, the amide I and amide II peaks of BSA (Fig. 3a) were shifted to 1,637 and 1,548 cm−1 upon the formation of beads (Fig. 3d, e), which could be explained by the existence of interactions (ionic, hydrogen bonding, and/or van der Waals’ forces) among formulation components during the complexation/gelation process.

Fig. 3
figure 3

FTIR spectra of a BSA; b gellan gum; c physical mixture of gellan gum and BSA (mass ratio of 2:1); d BSA-loaded calcium-gellan gum beads; e BSA-loaded chitosan-calcium-gellan gum beads

The physical characteristics of gellan gum, chitosan, and BSA in their pure forms, a physical mixture, and selected formulations were further investigated by calorimetric studies. The thermogram of pure gellan gum was characterized by an endothermic peak at around 121.79 °C (∆H = 53. 9,139 J/g) and a broad exothermic peak at 257.97 °C (Fig. 4a). The first peak was attributed to a dehydration process [25], while the second one denoted the temperature of gellan gum degradation [21]. However, the two peaks, respectively, shifted to 130.64 and 242.42 °C in the thermogram of blank calcium-gellan gum beads (Fig. 4d). These changes suggested that in the presence of Ca2+ ions, the “carboxylate-Ca2+-carboxylate” interactions are formed, which is confirmed by a sharp endothermic peak (∆H = 225.6,085 J/g) at 130.64 °C [25].

Fig. 4
figure 4

DSC thermograms of a gellan gum; b physical mixture of gellan gum and chitosan (mass ratio of 1:3); c chitosan; d blank calcium-gellan gum beads; e blank chitosan-calcium-gellan gum beads; f BSA; g physical mixture of gellan gum and BSA (mass ratio of 2:1); h BSA-loaded calcium-gellan gum beads; i BSA-loaded chitosan-calcium-gellan gum beads

The thermogram (Fig. 4c) of the chitosan polymer exhibited an endothermic peak at 122.51 °C, attributing to the evaporation of absorbed water, and higher degradation exothermic peaks at 310.82 °C [25, 26], respectively. In the thermograms of the physical mixture of chitosan and gellan gum and blank chitosan-calcium-gellan gum beads, the exothermic peaks were, respectively, transformed in a significantly broad band at the ranges of 243.09–270.91 °C (Fig. 4b) and 219.59–272.53 °C (Fig. 4e). Taking into account the endothermic peak at 124.20 °C in the physical mixture of chitosan and gellan gum and that at 131.46 °C in chitosan-calcium-gellan gum bead (Fig. 4b, e), it was concluded that this peak shift was correlated with the polyelectrolyte interaction between the chitosan and gellan gum [25].

The thermogram of BSA was characterized by two endothermic peaks at 118.12 and 254.72 °C (Fig. 4f), which corresponded to its denaturation and melting points, respectively. In the physical mixtures containing BSA and gellan gum, the second endothermic peak was supplanted by an exothermic peak at 252.59 °C (Fig. 4g). These changes in peak characteristics of BSA and gellan gum could be attributed to change in purity of individual components (because of “dilution effect”) and/or a physical interaction between BSA and gellan gum [21]. The absence of BSA endotherm in the thermogram of the physical mixture might be due to the dissolution of the crystalline albumin in the polymer at high temperatures during heating in DSC measurements. The second endothermic peak of BSA disappeared in the thermograms of BSA-loaded calcium-gellan gum beads (Fig. 4h) and BSA-loaded chitosan-calcium-gellan gum beads (Fig. 4i). The thermogram of the blank chitosan-calcium-gellan gum beads (Fig. 4e) was not different from that of BSA-loaded chitosan-calcium-gellan gum beads (Fig. 4i). This suggested that BSA may not recrystallize in the beads through gelation/polyelectrolyte complexation. That was to say that the core material albumin was uniformly dispersed in an amorphous state in the polymer matrix [4, 27].

The X-ray diffractograms of gellan gum, BSA, physical mixture of BSA and gellan gum (1:2), BSA-loaded calcium-gellan gum beads, and BSA-loaded chitosan-calcium-gellan gum beads are presented in Fig. 5. There were two strong crystalline peaks in the diffractogram of gellan gum (Fig. 5a), BSA (Fig. 5b), and mixture of BSA and gellan gum (Fig. 5c) at 2θ of around 9° and 20°. The raw chitosan (Fig. 5f) also showed one strong crystalline peak at around 20°. However, the crystalline peaks observed in BSA-loaded calcium-gellan gum beads (Fig. 5d) and BSA-loaded chitosan-calcium-gellan gum beads (Fig. 5e) almost disappeared. This observation indicated that the crystalline structure of BSA, gellan gum, and chitosan was disrupted after being combined together in the formulation of beads. That is, a substantial fraction of BSA was present as dissolved form in the polymer matrix. As both amorphous and nanocrystalline forms of BSA were not stable, they would tend to revert to the more thermodynamically stable crystalline form. However, gellan beads incorporating BSA inside its three-dimensional network could serve as stabilizing agent hindering the recrystallization [21].

Fig. 5
figure 5

X-ray diffractograms of pure gellan gum (a); BSA (b); physical mixture of BSA and gellan gum (1:2) (c); BSA-loaded calcium-gellan gum beads (d); BSA-loaded chitosan-calcium-gellan gum beads (e); chitosan (f)

In vitro albumin release and swelling characteristics of beads

The effect of chitosan concentration

Cationic polysaccharides-chitosan and anionic polysaccharides-gellan gum can form a polyelectrolyte complex membrane through electrostatic interaction [28], which is supposed to increase the strength of the calcium-gellan gum beads and decrease their permeability. The results indicated that chitosan played a crucial role in the modulation of the release and swelling of beads during the GI transit (Fig. 6). Figure 6a showed that the swelling ratio of beads increased with increasing chitosan concentration. However, the BSA release percentage of beads was the lowest at 0.50 % of chitosan concentration. Also, BSA exhibited a burst release during the initial 0.5 h, which was up to nearly 60 % (Fig. 6b). In addition, in the absence of chitosan, the dried beads absorbed moisture and stuck together after short-term exposure to the air, while this phenomenon did not appear for the chitosan-calcium-gellan gum beads. It may be able to explain this phenomenon that chitosan-gellan gum polyelectrolyte composite membrane could effectively protect calcium-gellan gum beads from water vapor in the air.

Fig. 6
figure 6

Effect of chitosan concentration on swelling behavior (a) and release profile (b) of the beads in simulated gastric fluid (pH 1.2, NaCl/HCl buffer solution) for 2 h, subsequently in simulated small intestinal fluid (pH 6.8, phosphate-buffered saline) for 2 h and in simulated colonic fluid (pH 7.4, phosphate-buffered saline) for 3 h. Data were presented as mean ± SE (n = 3)

In the absence of chitosan, there was only a three-dimensional network structure formed by ionotropic interaction between gellan gum molecules and calcium ions but no chitosan-gellan gum polyelectrolyte complex. At this point, the permeability of beads was greater than that in the presence of chitosan, which also resulted in low encapsulation efficiency and loading capacity of beads. After the raw chitosan was dissolved in an acetic acid solution, a clear and transparent solution was obtained, which suggested that chitosan is fully dissolved and it is not necessary to filter for further purification. At low concentrations (≤0.5 %), chitosan was fully dissolved in acetic acid solution as a form of linear molecules and the solution viscosity was very low. Thus, the linear chitosan molecules could fully disperse on the outer layer of calcium-gellan gum beads and penetrate into the inner mesh of the calcium-gellan gum. The binding between amino groups of chitosan and remaining carboxyl groups of gellan gum led to the formation of the dense membrane and greatly reduced the porosity and permeability of beads. The higher the chitosan concentration was, the more significant these effects were. However, the formation of the chitosan-gellan gum polyelectrolyte complex membrane seemed to be difficult above the concentration of 0.5 %. It may be due to the fact that chitosan could not effectively penetrate into the inner mesh of the calcium-gellan gum. In the simulated gastric fluid, carboxylic groups of gellan gum chains on the bead surface converted to COOH due to the lower medium pH (1.2) than pKa of gellan gum (~3.06) [29]. Simultaneously, displacement of calcium ion (Ca2+) with H+ or Na+ occurred at the outer layers of beads. Thus, calcium-gellan gum network structure was destroyed, leading to the dissolution of calcium-gellan gum beads and serious burst release of core material [16]. But, the protonation of chitosan amino groups occurred mainly on the outer layer of chitosan-calcium-gellan gum beads in SGF. The release of BSA was mainly controlled by the dissolution of the external chitosan layer as well as the BSA concentration difference on both sides of the semipermeable membrane. The release rate of chitosan-calcium-gellan gum beads was lower than that of the calcium-gellan gum beads. In addition, chitosan at high concentrations (≥0. 5 %) could improve the swelling degree and increase the path of BSA diffusion from inner to outer of beads. However, further increasing chitosan concentration would increase the permeability of beads. The beads could swell to a larger extent in alkali medium because of the repulsion of fully negative charged –COO groups of gellan gum [20].

The effect of calcium chloride concentration

Some researchers investigated the influence of different divalent cations on the quality of the gellan gum beads and found that the beads prepared with Ca2+ were the best in terms of quality and mechanical strength. The beads prepared with Zn2+ and Cu2+ were fragile and therefore not suitable for bead characterization studies [30]. In the present study, the beads had poor mechanical strength in the absence of Ca2+. Furthermore, it was failing to form particles during the drying process due to a serious collapse of beads. Therefore, the participation of the divalent cation was necessary in the process of gellan gum bead preparation. Figure 7a showed that the swelling ratio of beads prepared at the calcium ion concentration of 0.25 or 0.50 mol/L was much lower, compared with those prepared at the calcium ion concentration of 0.1 mol/L. Figure 7b showed that the burst release in the initial 0.5 h was still very serious but improved, which dropped to 55.71 % at the calcium ion concentration of 0.25 mol/L.

Fig. 7
figure 7

Effect of calcium chloride concentration on swelling ratio (a) and release profile (b) of the beads in simulated gastric fluid (pH 1.2, NaCl/HCl buffer solution) for 2 h, subsequently in simulated small intestinal fluid (pH 6., phosphate-buffered saline) for 2 h and in simulated colonic fluid (pH 7.4, phosphate-buffered saline) for 3 h. Data were presented as mean ± SE (n = 3)

In aqueous solution, the gelation of gellan was accompanied by a two-step process, namely formation of double helices from random coil chains and an aggregation of pairs of double helices to form a three-dimensional network [14]. However, the carboxyl side chains of gellan gum molecules repelled each other due to electrostatic interactions, which impeded the aggregation of double helices. The “carboxyl-Ca2+-carboxyl” junction zones between the gellan gum molecules and Ca2+ could remove the electric repulsion and accelerate the double helices to form a more stable three-dimensional network junction [21]. Therefore, gel strength was enhanced with increasing calcium ion concentration at low concentrations, whereas excess calcium ions may occupy overmuch anion-binding sites of the gellan gum molecules and hinder the orderly aggregation of the double-helix structure of gellan gum, which could weaken the gel strength and increase the permeability of beads [30].

The effect of gellan gum concentration

With increasing gellan gum concentration, the swelling ratio of beads increased while the BSA release of beads decreased (Fig. 8). Verma et al. [14] investigated the effect of gellan gum concentration (1, 3, 5 %, w/v) on the quality of rifabutin-loaded floating gellan gum beads and obtained similar results about the in vitro release of drug. In this experiment, beads were prepared by dropwise adding of the gellan gum solution into the cross-linking solution through a needle. When the concentration of gellan gum was higher than 1.5 %, the solution with high viscosity could not form granulated beads because of the needle clogging. Therefore, no attempt for the high concentration of gellan gum was taken.

Fig. 8
figure 8

Effect of gellan gum concentration on swelling ratio (a) and release profile (b) of the beads in simulated gastric fluid (pH 1.2, NaCl/HCl buffer solution) for 2 h, subsequently in simulated small intestinal fluid (pH 6.8, phosphate-buffered saline) for 2 h and in simulated colonic fluid (pH 7.4, phosphate-buffered saline) for 3 h. Data were presented as mean ± SE (n = 3)

Its high viscosity exerted a positive influence on a more compacter three-dimensional network structure and the improvement of gel strength. Moreover, this could create a long and tortuous path for water molecules and BSA to permeate, which led to the improvement of in vitro release effect [4]. Furthermore, the formed thick and dense membrane by chitosan-gellan gum complex reduced the beads’ permeability to delay drug release.

The effect of drying conditions

Figures 9 and 10 showed the swelling and release depending on the type of drying, as a function of incubation time in SGI fluid. The difference in release profile is probably a consequence of structural differences resulting from different water removal mechanisms. The surface of oven-dried beads showed crack. On the contrary, the surface of vacuum-dried beads had no obvious crack and was relatively smooth. With much looser structure and stronger absorption capacity, the freeze-dried beads had a greater swelling ratio compared with the other two. The BSA release was much slower in the vacuum-dried beads than in the oven- and freeze-dried ones (Fig. 10b). It is noteworthy that the cumulative BSA released from the vacuum-dried beads in simulated gastric fluid for 2 h was just 35 %, which was approximately 10 % lower than that of the oven-dried beads (Fig. 10b).

Fig. 9
figure 9

Optical micrographs (×40) of beads during swelling period. a Before the swelling (dried state); b after incubating in simulated gastric fluid for 2 h; c in simulated small intestinal fluid for 3 h; d in simulated colonic fluid for 3 h

Fig. 10
figure 10

Effect of drying methods on swelling ratio (a) and release profile (b) of the beads in simulated gastric fluid (pH 1.2, NaCl/HCl buffer solution) for 2 h, subsequently in simulated small intestinal fluid (pH 6.8, phosphate-buffered saline) for 2 h and in simulated colonic fluid (pH 7.4, phosphate-buffered saline) for 3 h. Data were presented as mean ± SE (n = 3)

The drying methods were supposed to affect the protein release of beads. During the oven-drying process, a fluid boundary layer was formed on the surface of beads. When water vapor diffused into the air through the boundary layer, the moving speed of the water from the inside to the surface was lower than the evaporation rate of the boundary layer surface, which caused the rupture of the boundary layer water film. The phenomena of hardening, partial cracks, and structural collapse appeared on the surface of beads, which led to the larger permeability and serious albumin burst release during the swelling process of beads. However, the surface hardening and partial cracks could not be found on the surface of beads by vacuum-drying due to the quick diffusion of moisture toward the surface under the large pressure difference between the interior and surface of beads. Consequently, the surface structure of the vacuum-dried beads was more complete and compact compared with the beads obtained by oven-drying. This is in agreement with the greater retention of protein in the vacuum-dried beads. During the freeze-drying process, the wet beads were firstly frozen into a solid and then moisture was removed by the sublimation from the solid state to gas. Because the structure of beads was fixed in the preliminary state, the shape and size of beads remained basically unchanged after drying. The beads were loosely spongy and easy to absorb water and swell. This process was believed to increase the permeability of beads and accelerate the albumin release, a fact that might not be desirable.

Albumin release kinetics

In order to compare the albumin release rate, a time point approach was adopted. The values of t 50% (i.e., time required for the release of 50 % core material load) were calculated (Table 2). The t 50% in the range from 0.29 ± 0.01 to 4.27 ± 0.60 indicated that the variation in formulation parameters resulted in significant difference in the core material release rate, especially the gellan gum concentration and drying conditions. Table 2 also listed the correlation coefficients (r 2) of the release profiles when different mathematical models for the analysis of the release kinetics were applied. For the models studied, the release profiles showed higher correlation coefficients for the Higuchi and Korsmeyer–Peppas models. For the models derived from the Korsmeyer–Peppas equation, it is the n value that characterizes the albumin release mechanism. According to the n values (Table 2) that were <0.43, the mechanism of albumin release from spherical polymeric devices could be Fickian diffusion through the swelling matrix.

Conclusions

The chitosan-calcium-gellan gum beads incorporating albumin were prepared by a combination of ionotropic gelation and polyelectrolyte complexation which avoided the use of high-temperature treatment, toxic cross-linker, and organic reagents. The concentration of chitosan, calcium, and gellan gum had an obvious influence on the encapsulation and release properties of beads. The beads through polyelectrolyte complexation of chitosan and gellan gum combined with vacuum drying not only slowed down the albumin burst release in simulated stomach fluid, but also significantly prolong the albumin release time in simulated small intestinal and colonic fluid. The swelling behavior of beads was pH-responsive, and the release of BSA was mainly triggered by a diffusion mechanism in the process of swelling (Fickian diffusion). The amorphous dispersion of albumin in the beads has also been confirmed. Consequently, the beads have the potential for oral controlled delivery application of water-soluble protein–based and water-soluble polypeptide–based functional ingredients which could retain the biological effect of the active ingredients.