Skip to main content

Advertisement

Log in

Improved efficiency for MRI-SPET registration based on mutual information

  • Original article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract.

Mutual information has been proposed as a criterion for image registration. The criterion is calculated from a two-dimensional grey-scale histogram of the image pair being registered. In this paper we study how sparse sampling can be used to increase speed performance using the registration algorithm of Maes et al. (IEEE Trans Med Imaging 1997; 16: 187–198) with a focus on registration of MRI-SPET brain images. In particular we investigate how sparse sampling and parameters such as the number of bins used for the grey-scale histograms and smoothing of the data prior to registration affect accuracy and robustness of the registration. The method was validated using both simulated and human data. Our results show that sparse sampling introduced local maxima into the mutual information similarity function when the number of bins used for the histograms was large. To speed up registration while retaining robustness, smoothing of the data prior to registration was used and a coarse to fine subsampling protocol, where the number of bins in the histograms were dependent on the subsampling factor, was employed. For the simulated data, the method was able to recover known transformations with an accuracy of about 1 mm. Using the human data, there were no significant differences in the recovered transformation parameters when the suggested subsampling scheme was used compared with when no subsampling was used, but there was a more than tenfold increase in speed. Our results show that, with the appropriate choice of parameters, the method can accurately register MRI-SPET brain images even when very efficient sampling protocols are used.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 14 December 1999 and in revised form 15 March 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thurfjell, L., Lau, Y., Andersson, J. et al. Improved efficiency for MRI-SPET registration based on mutual information. Eur J Nucl Med 27, 847–856 (2000). https://doi.org/10.1007/s002590000270

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002590000270

Navigation