Skip to main content
Erschienen in: Experiments in Fluids 1/2019

01.01.2019 | Research Article

Volumetric calibration enhancements for single-camera light-field PIV

verfasst von: Shengxian Shi, Junfei Ding, T. H. New, You Liu, Hanmo Zhang

Erschienen in: Experiments in Fluids | Ausgabe 1/2019

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

This work presents a volumetric calibration method for single-camera light-field particle image velocimetry (light-field PIV or LF-PIV). The proposed technique makes use of the unique point-like feature of particle light-field images to accurately determine affected pixels for a spatial voxel over a relative large measurement volume. A calibration model is derived based on Gaussian optics, which relates a spatial point light source with its confusion circle produced on microlens array (MLA), and optical distortions are accounted for by introducing five calibration parameters. By taking lens defects and misalignment between MLA and image sensor into account, the calibration method can calculate weighting coefficient for particle image reconstruction more accurately than the theoretical ray-tracing method, especially for regions further away from focal plane where light ray deflections are significant due to optical distortions. The volumetric calibration method was validated by simulation tests using synthetic light-field images, and has been successfully applied to a classic vortex-ring LF-PIV measurement, where the measurable range in depth direction was successfully extended and the quality of reconstructed volumetric velocity field was greatly improved.

Graphical abstract

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Belden J (2013) Calibration of multi-camera systems with refractive interfaces. Exp Fluids 54:1463CrossRef Belden J (2013) Calibration of multi-camera systems with refractive interfaces. Exp Fluids 54:1463CrossRef
Zurück zum Zitat Belden J, Truscott TT, Axiak M, Techet AH (2010) Three-dimensional synthetic aperture particle image velocimetry. Meas Sci Technol 21:125403CrossRef Belden J, Truscott TT, Axiak M, Techet AH (2010) Three-dimensional synthetic aperture particle image velocimetry. Meas Sci Technol 21:125403CrossRef
Zurück zum Zitat Bok Y, Jeon H, Kweon I (2017) Geometric calibration of micro-lens-based light field cameras using line features. IEEE Trans Pattern Anal Mach Intell 39:287–300CrossRef Bok Y, Jeon H, Kweon I (2017) Geometric calibration of micro-lens-based light field cameras using line features. IEEE Trans Pattern Anal Mach Intell 39:287–300CrossRef
Zurück zum Zitat Chen H, Sick V (2017) Three-dimensional three-component air flow visualization in a steady-state engine flow bench using a plenoptic camera. SAE Int J Engines 10:625–635CrossRef Chen H, Sick V (2017) Three-dimensional three-component air flow visualization in a steady-state engine flow bench using a plenoptic camera. SAE Int J Engines 10:625–635CrossRef
Zurück zum Zitat Ding J, Wang J, Liu Y, Shi S (2015) Dense ray tracing based reconstruction algorithm for light-field volumetric particle image velocimetry. In: 7th Australian conference on laser diagnostics in fluid mechanics and combustion. Melbourne, Australia Ding J, Wang J, Liu Y, Shi S (2015) Dense ray tracing based reconstruction algorithm for light-field volumetric particle image velocimetry. In: 7th Australian conference on laser diagnostics in fluid mechanics and combustion. Melbourne, Australia
Zurück zum Zitat Fahringer T, Thurow B (2016) Filtered refocusing: a volumetric reconstruction algorithm for plenoptic-PIV. Meas Sci Technol 27:094005CrossRef Fahringer T, Thurow B (2016) Filtered refocusing: a volumetric reconstruction algorithm for plenoptic-PIV. Meas Sci Technol 27:094005CrossRef
Zurück zum Zitat Fahringer T, Lynch K, Thurow B (2015) Volumetric particle image velocimetry with a single plenoptic camera. Meas Sci Technol 26:115201CrossRef Fahringer T, Lynch K, Thurow B (2015) Volumetric particle image velocimetry with a single plenoptic camera. Meas Sci Technol 26:115201CrossRef
Zurück zum Zitat Georgiev T, Intwala C (2006) Light field camera design for integral view photography. Adobe Technical Report Georgiev T, Intwala C (2006) Light field camera design for integral view photography. Adobe Technical Report
Zurück zum Zitat Hall E, Fahringer T, Guildenbecher D, Thurow B (2018) Volumetric calibration of a plenoptic camera. Appl Opt 57:914–923CrossRef Hall E, Fahringer T, Guildenbecher D, Thurow B (2018) Volumetric calibration of a plenoptic camera. Appl Opt 57:914–923CrossRef
Zurück zum Zitat Heinze C, Spyropoulos S, Hussmann S, Perwass C (2016) Automated robust metric calibration algorithm for multifocus plenoptic cameras. IEEE Trans Instrum Meas 65:1197–1205CrossRef Heinze C, Spyropoulos S, Hussmann S, Perwass C (2016) Automated robust metric calibration algorithm for multifocus plenoptic cameras. IEEE Trans Instrum Meas 65:1197–1205CrossRef
Zurück zum Zitat Maas HG (1995) New developments in multimedia photogrammetry. In: Grún A, Kahmen H (eds) Optical 3D measurement techniques III. Wichmann Verlag, Karlsruhe Maas HG (1995) New developments in multimedia photogrammetry. In: Grún A, Kahmen H (eds) Optical 3D measurement techniques III. Wichmann Verlag, Karlsruhe
Zurück zum Zitat New TH, Shi S, Zang B (2016) Some observations on vortex-ring collisions upon inclined surfaces. Exp Fluids 57:109CrossRef New TH, Shi S, Zang B (2016) Some observations on vortex-ring collisions upon inclined surfaces. Exp Fluids 57:109CrossRef
Zurück zum Zitat Ng R (2006) Digital light-field photography. PhD thesis, Stanford, CA, USA Ng R (2006) Digital light-field photography. PhD thesis, Stanford, CA, USA
Zurück zum Zitat Shi S, Wang J, Ding J, Zhao Z, New TH (2016) Parametric study on light-field volumetric particle image velocimetry. Flow Meas Instrum 49:70–88CrossRef Shi S, Wang J, Ding J, Zhao Z, New TH (2016) Parametric study on light-field volumetric particle image velocimetry. Flow Meas Instrum 49:70–88CrossRef
Zurück zum Zitat Shi S, Ding J, New TH, Soria J (2017) Light-field camera-based 3D volumetric particle image velocimetry with dense ray tracing reconstruction technique. Exp Fluids 58:78CrossRef Shi S, Ding J, New TH, Soria J (2017) Light-field camera-based 3D volumetric particle image velocimetry with dense ray tracing reconstruction technique. Exp Fluids 58:78CrossRef
Zurück zum Zitat Shi S, Ding J, Atkinson C, Soria J, New TH (2018) A detailed comparison of single-camera light-field PIV and tomographic PIV. Exp Fluids 59:46CrossRef Shi S, Ding J, Atkinson C, Soria J, New TH (2018) A detailed comparison of single-camera light-field PIV and tomographic PIV. Exp Fluids 59:46CrossRef
Zurück zum Zitat Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441CrossRef Soloff SM, Adrian RJ, Liu ZC (1997) Distortion compensation for generalized stereoscopic particle image velocimetry. Meas Sci Technol 8:1441CrossRef
Zurück zum Zitat Thomason CM, Thurow BS, Fahringer TW (2014) Calibration of a microlens array for a plenoptic camera. In: 52nd aerospace sciences meeting Thomason CM, Thurow BS, Fahringer TW (2014) Calibration of a microlens array for a plenoptic camera. In: 52nd aerospace sciences meeting
Zurück zum Zitat Wieneke B (2008) Volume self-calibration for 3D particle image velocimetry. Exp Fluids 45:549–556CrossRef Wieneke B (2008) Volume self-calibration for 3D particle image velocimetry. Exp Fluids 45:549–556CrossRef
Zurück zum Zitat Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29:1–15CrossRef Wieneke B (2018) Improvements for volume self-calibration. Meas Sci Technol 29:1–15CrossRef
Metadaten
Titel
Volumetric calibration enhancements for single-camera light-field PIV
verfasst von
Shengxian Shi
Junfei Ding
T. H. New
You Liu
Hanmo Zhang
Publikationsdatum
01.01.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
Experiments in Fluids / Ausgabe 1/2019
Print ISSN: 0723-4864
Elektronische ISSN: 1432-1114
DOI
https://doi.org/10.1007/s00348-018-2670-5

Weitere Artikel der Ausgabe 1/2019

Experiments in Fluids 1/2019 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.