Abstract
Drowsiness and increased tendency to fall asleep during daytime is still a generally underestimated problem. An increased tendency to fall asleep limits the efficiency at work and substantially increases the risk of accidents. Reduced alertness is difficult to assess, particularly under real life settings. Most of the available measuring procedures are laboratory-oriented and their applicability under field conditions is limited; their validity and sensitivity are often a matter of controversy. The spontaneous eye blink is considered to be a suitable ocular indicator for fatigue diagnostics. To evaluate eye blink parameters as a drowsiness indicator, a contact-free method for the measurement of spontaneous eye blinks was developed. An infrared sensor clipped to an eyeglass frame records eyelid movements continuously. In a series of sessions with 60 healthy adult participants, the validity of spontaneous blink parameters was investigated. The subjective state was determined by means of questionnaires immediately before the recording of eye blinks. The results show that several parameters of the spontaneous eye blink can be used as indicators in fatigue diagnostics. The parameters blink duration and reopening time in particular change reliably with increasing drowsiness. Furthermore, the proportion of long closure duration blinks proves to be an informative parameter. The results demonstrate that the measurement of eye blink parameters provides reliable information about drowsiness/sleepiness, which may also be applied to the continuous monitoring of the tendency to fall asleep.
Similar content being viewed by others
Notes
The sensor works with invisible chopped infrared light of low intensity far below the permitted threshold of German regulations DIN VDE 0837
References
Barbato G, Ficca G, Muscettola G, Fichele M, Beatrice M, Rinaldi F (2000) Diurnal variation in spontaneous eye-blink rate. Psychiatr Res 93:145–151
Bixler EO, Kales A, Leo LA, Slye T (1973) A comparison of subjective and objective sleep laboratory findings in insomniac patients. Sleep Res 2:143
Blount WP (1928) Studies of the movements of the eyelids of animals: blinking. Q J Exp Physiol 18:111–125
Brezinova V, Kendell RE (1977) Smooth pursuit eye movements of schizophrenics and normal people under stress. Br J Psychiatr 130:59–63
Caffier PP (2002) Spontaner Lidschlag als Ermüdungsindikator bei Registrierung mittels kontaktfreiem Infrarotsensor. Schriftenreihe der Bundesanstalt für Arbeitsschutz und Arbeitsmedizin. Wirtschaftsverlag NW S 69 Dortmund/ Berlin
Caffier PP, Ullsperger U, Erdmann U (1999) Relationship between personal state ratings and eyeblink parameters recorded with contact-free infrared sensor. Psychophysiology 36:S20
Carpenter A (1948) The rate of blinking during prolonged visual search. J Exp Psychol 38:587–591
Carskadon MA, Dement WC (1985) The multiple sleep latency test: What does it measure? Sleep 5:67–72
Collet C, Delhomme G, Dittmar A, Khardi S, Vernet-Maury E (1999) Electrodermal tonic level variations associated with thermo-vascular and cardio-respiratory recordings as reliable indices for the detection of drowsiness in automobile drivers. Psychophysiology 36:S21
Connor J, Whitlock G, Norton R, Jackson R (2001) The role of driver sleepiness in car crashes: a systematic review of epidemiological studies. Accid Anal Prev 33:31–41
Davson H (1990) Blinking. In: Davson H (ed) Physiology of the eye. Pergamon, New York, pp 786–791
Doane MG (1980) Interaction of eyelids and tears in corneal wetting and the dynamics of the normal human eyeblink. Am J Ophthalmol 89:507–516
Folstein MF, Luria R (1973) Reliability, validity and clinical application of the Visual Analogue Mood Scale. Psychol Med 3:479–486
George CF (2000) Vigilance impairment: assessment by driving simulators. Sleep 23 (S4):S115–S118
Goldstein R, Walrath LC, Stern JA (1982) Blink activity as a function of stimulus modality and schedule of presentation in a discrimination task (Tech. Report, U.S. Dept. of the Interior, Bureau of Mines, Contract no. J0205064). Washington University Behavior Research Laboratory, St. Louis, Mo.
Haider E, Rohmert W (1976) Untersuchung zur Lidschlussfrequenz bei vierstündiger simulierter Kraftfahrzeugfahrt. Eur J Appl Psychol 39:137–148
Hoddes E, Dement WC, Zarcone V (1973) The development and use of the Stanford Sleepiness Scale (SSS). Psychophysiology 10:431–436
Hoffmann RM, Müller T, Hajak G, Cassel W (1997) Abend-Morgenprotokolle in Schlafforschung und Schlafmedizin – Ein Standardinstrument für den deutschsprachigen Raum. Somnologie 1:103–109
Horne JA, Reyner LA (1999) Vehicle accidents related to sleep: a review. Occup Environ Med 56 (5):289–294
Johns MW (1991) A new method for measuring daytime sleepiness: the Epworth Sleepiness Scale. Sleep 14 (6):540–545
Jordan W, Hajak G (1997) Gestörter Schlaf – was tun? Arcis, Munich
Kennard DW, Glaser GH (1964) An analysis of eyelid movements. J Nerv Ment Dis 139:31–48
Kopriva K, Horvath M, Stern JA (1970) The effect of pentobarbital on oculomotor activity. [Unpublished manuscript, Czechoslovakia Institute of Physiology, Prague]
Lukiesh M (1947) Reading and the rate of blinking. J Exp Psychol 37:266–288
Mitler MM, Gujavaraty S, Browman CP (1982) Maintenance of wakefulness test: a polysomnographic technique for evaluating treatment efficacy in patients with excessive somnolence. Electroencephalogr Clin Neurophysiol 53:658–661
Morris T, Miller JC (1996) Electrooculographic and performance indices of fatigue during simulated flight. Biol Psychol 42:343–360
Mourant RR, Lakshmanan R, Chantadisai R (1981) Visual fatigue and CRT display terminals. Hum Fact 23:529–540
Nitsch JR (1974) Die hierarchische Struktur des Eigenzustandes – ein Approximationsversuch mit Hilfe der Binärstrukturanalyse (BISTRAN). Diagnostika 20:142–164
Ogawa K (1998) Development of a Drowsiness Detection System. In: Proceedings of Second International Conference on Psychophysiology in Ergonomics (PIE). International Ergonomics Association (IEA), London, pp 122–123
Oginski A, Oginska H, Pokorski J, Kmita W, Gozdziela R (2000) Internal and external factors influencing time-related injury risk in continuous shift work. Int J Occup Saf Ergon 6 (3):405–421
Oster PJ, Stern JA (1980) Measurement of eye movement: electrooculography. In: Martin I (ed) Techniques in psychophysiology. Wiley, Chichester, pp 275–309
Ponder E, Kennedy WP (1928) On the act of blinking. Q J Exp Physiol 18:89–110
Randerath W, Gerdesmeyer C, Ströhlein G, Rühle KH (1997) Messung der Vigilanz mittels Fahrsimulator vor und nach nCPAP – Vergleich zweier Simulationsprogramme mit unterschiedlicher Ereignishäufigkeit. Somnologie 1:110–114
Satake T (1995) A study of evaluation of drowsiness – analysis of blinking duration by facial image. In: Proceedings of 11th Symposium on Human Interface. Human Interface Society, Kyoto/Japan, pp 225–230
Schandry R (1996) Lehrbuch der Psychophysiologie. Psychologie Verlags Union, Munich
Sirevaag EJ, Stern JA (2000) Ocular measures of fatigue and cognitive factors. In: Backs RW (ed) Engineering psychophysiology. Issues and applications. Erlbaum, Mahwah, N.J., pp 269–287
Stern JA, Beideman L, Chen SC (1976) Effect of alcohol on visual search and motor performance during complex task performance. In: Horvath M (ed) Adverse effects of environmental chemicals and psychotropic drugs: neurophysiological and behavioral tests, vol 2. Elsevier, Amsterdam, pp 53–68
Stern JA, Walrath LC, Goldstein R (1984) The endogenous eyeblink. Psychophysiology 21:22–33
Stern JA, Boyer DJ, Schroeder D (1994) Blink rate: a possible measure of fatigue. Hum Fact 36 (2):285–297
Stern JA, Boyer DJ, Schroeder D, Touchstone MR, Stoliarov N (1996) Blinks, saccades, and fixation pauses during vigilance task performance: II. Gender and time-of-day (DOT/FAA/AM/96/9). FAA Office of Aviation Medicine, Washington DC
Sugiyama K, Nakano T, Yamamoto S, Ishihara T, Fujii H, Akutsu E (1996) Method of detecting drowsiness level by utilizing blinking duration. JSAE Rev 17 (2):159–163
U.S. Department of Transportation, Federal Highway Administration (1999) Eye-activity measures of fatigue and napping as a fatigue countermeasure (Final Report, FHWA-MC-99–028). Federal Highway Administration, Washington DC
Weess HG, Sauter C, Geisler P, Böhning W, Wilhelm B, Rotte M, Gresele C, Schneider C, Schulz H, Lund R, Steinberg R (2000) Vigilanz, Einschlafneigung, Daueraufmerksamkeit, Müdigkeit, Schläfrigkeit – Diagnostische Instrumentarien zur Messung müdigkeits- und schläfrigkeitsbezogener Prozesse und deren Gütekriterien. Somnologie 4:20–38
Wierwille WW (1999) Desired attributes of drowsy driver monitoring and candidate Technologies for implementation. In: Ocular measures of driver alertness: technical conference proceedings (FHWA-MC-99–136). Federal Highway Administration, Washington DC, pp 130–143
Wilson GF, Lambert J (1999) Physiological effects of varied mental workload in pilots during flight. Psychophysiology 36:S126
Wright NA, McGown AS (1999) Vigilance on the civil flight deck: incidences of sleepiness and sleep during long-haul flights and associated changes in physiological parameters. Psychophysiology 36:S127
Yamada F (1998) Frontal midline theta rhythm and eyeblinking activity during a VDT task and a video game: useful tools for psychophysiology in ergonomics. Ergonomics 41 (5):678–688
Zametkin AJ, Stevens JR, Pittman R (1979) Ontogeny of spontaneous blinking and habituation of the blink reflex. Ann Neurol 5:452–457
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Caffier, P.P., Erdmann, U. & Ullsperger, P. Experimental evaluation of eye-blink parameters as a drowsiness measure. Eur J Appl Physiol 89, 319–325 (2003). https://doi.org/10.1007/s00421-003-0807-5
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00421-003-0807-5