Skip to main content
Erschienen in: Neural Computing and Applications 19/2020

21.10.2019 | Multi-access Edge Computing Enabled Internet of Things

Overflow remote warning using improved fuzzy c-means clustering in IoT monitoring system based on multi-access edge computing

verfasst von: Haibo Liang, Gang Liu, Jianchong Gao, Muhammad Junaid Khan

Erschienen in: Neural Computing and Applications | Ausgabe 19/2020

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

In existing overflow remote intelligent monitoring system, a huge amount of data uploading and multiple processing brings great challenges to the bandwidth load and real-time feedback of the server. Based on the Multiple Access Edge Computing Architecture (MEC), this paper proposes an Internet of Things overflow intelligent monitoring system based on multi-access edge computing. As the middle layer of the system, edge computing can provide real-time local services for field devices, and it can reduce the data uploading amount by preliminarily analyzing the computing tasks of the cloud computing platform. At the same time, for the current domestic and international artificial intelligence-based overflow warning model, it needs a large amount of prior knowledge or training data before use, and the accuracy, real time, and reliability of overflow monitoring are limited by prior knowledge and training data and other issues. In this paper, the information entropy theory has been adopted to improve fuzzy c-means clustering (FCM) algorithm to overcome the disadvantage that the user gives the number of clustering actively in FCM clustering. Then, considering the correlation between the occurrence of overflow accident and the changing trend of standpipe pressure and casing pressure, an intelligent early warning model of drilling overflow accident is proposed by using the improved FCM clustering method based on information entropy. The early warning model uses the adaptive determination of the number of clusters for clustering, which not only ensures the quality of the cluster but also improves the accuracy and reliability of the overflow warning. The warning result of the overflow accident is output according to the clustering fitting result and the sensitivity of the overflow accident. Finally, the drilling data of YY oil well in XX oilfield considered as the research object.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Chen P (2005) Drilling and well completion engineering. Petroleum Industry Press, Beijing Chen P (2005) Drilling and well completion engineering. Petroleum Industry Press, Beijing
7.
Zurück zum Zitat Deng HX, Wei GH, Li JL et al. (2018) An overflow intelligent early-warning model based on downhole parameters measurement. In: International conference on image and video processing, and artificial intelligence. International Society for Optics and Photonics 10836: 1083624. https://doi.org/10.1117/12.2514042 Deng HX, Wei GH, Li JL et al. (2018) An overflow intelligent early-warning model based on downhole parameters measurement. In: International conference on image and video processing, and artificial intelligence. International Society for Optics and Photonics 10836: 1083624. https://​doi.​org/​10.​1117/​12.​2514042
12.
Zurück zum Zitat Reitsma D (2010) A simplified and highly effective method to identify influx and losses during managed pressure drilling without the use of a Coriolis flow meter. SPE/IADC managed pressure drilling and underbalanced operations conference and exhibition. Society of Petroleum Engineers, SPE-130312-MS. https://doi.org/10.2118/130312-MS Reitsma D (2010) A simplified and highly effective method to identify influx and losses during managed pressure drilling without the use of a Coriolis flow meter. SPE/IADC managed pressure drilling and underbalanced operations conference and exhibition. Society of Petroleum Engineers, SPE-130312-MS. https://​doi.​org/​10.​2118/​130312-MS
13.
Zurück zum Zitat Reitsma D (2011) Development of an automated system for the rapid detection of drilling anomalies using standpipe and discharge pressure. In: SPE/IADC drilling conference and exhibition. Society of Petroleum Engineers, SPE-140255-MS. https://doi.org/10.2118/140255-MS Reitsma D (2011) Development of an automated system for the rapid detection of drilling anomalies using standpipe and discharge pressure. In: SPE/IADC drilling conference and exhibition. Society of Petroleum Engineers, SPE-140255-MS. https://​doi.​org/​10.​2118/​140255-MS
14.
Zurück zum Zitat Mills I et al. (2012) Simulator and the first field test results of an automated early kick detection system that uses standpipe pressure and annular discharge pressure. In: SPE/IADC managed pressure drilling and underbalanced operations conference and exhibition. Society of Petroleum Engineers, SPE-156902-MS. https://doi.org/10.2118/156902-MS Mills I et al. (2012) Simulator and the first field test results of an automated early kick detection system that uses standpipe pressure and annular discharge pressure. In: SPE/IADC managed pressure drilling and underbalanced operations conference and exhibition. Society of Petroleum Engineers, SPE-156902-MS. https://​doi.​org/​10.​2118/​156902-MS
Metadaten
Titel
Overflow remote warning using improved fuzzy c-means clustering in IoT monitoring system based on multi-access edge computing
verfasst von
Haibo Liang
Gang Liu
Jianchong Gao
Muhammad Junaid Khan
Publikationsdatum
21.10.2019
Verlag
Springer London
Erschienen in
Neural Computing and Applications / Ausgabe 19/2020
Print ISSN: 0941-0643
Elektronische ISSN: 1433-3058
DOI
https://doi.org/10.1007/s00521-019-04540-y

Weitere Artikel der Ausgabe 19/2020

Neural Computing and Applications 19/2020 Zur Ausgabe

S.I.: Artificial Intelligence International Conference - A2IC 2018

Fusing hotel ratings and reviews with hesitant terms and consensus measures