Abstract

In this paper, an analytical model for evaluation of membrane displacement, multiple resonances, mechanical impedances and bandwidth profile of capacitive micromachined ultrasonic transducers (CMUTs) developed by MEMS technology for medical imaging is presented. Improvement in the results is brought in by taking into account the finiteness of the electrodes diameter. 3-D models for practical membrane shapes are carried out by FEM PZFLEX simulation. The model shows that CMUT is a multiple resonance device. The analytical values of the fundamental resonance agree excellently with the published experimental results. The 50 µm radius devices are theoretically found to be most efficient at 2.35 MHz. The 3-dB fractional bandwidth is also evaluated from the improved analytical model. Moreover, physical solution insists that at a certain bias voltage, the residual force in the membrane will no longer resist the electrostatic force of attraction, resulting in membrane collapse which is clearly demonstrated in this work.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Bozkurt A, Degertekin F, Atalar A, Khuri-Yakub BT (1998) Analytic modeling of loss and cross-coupling in capacitive micromachined ultrasonic transducers. IEEE Ultrason Symp: 1025–1028 Bozkurt A, Degertekin F, Atalar A, Khuri-Yakub BT (1998) Analytic modeling of loss and cross-coupling in capacitive micromachined ultrasonic transducers. IEEE Ultrason Symp: 1025–1028
Zurück zum Zitat Buhrdorf A, Ahrens O, Binder J (2001) Capacitive micromachined ultrasonic transducers and their application. IEEE Ultrason Symp: 933–940 Buhrdorf A, Ahrens O, Binder J (2001) Capacitive micromachined ultrasonic transducers and their application. IEEE Ultrason Symp: 933–940
Zurück zum Zitat Caronti A, Caliano G, Iula A, Pappalardo M (2002a) An accurate model for capacitive micromachined ultrasonic transducers. IEEE Trans Ultrason Ferroelectr Freq Control 49:159–168CrossRef Caronti A, Caliano G, Iula A, Pappalardo M (2002a) An accurate model for capacitive micromachined ultrasonic transducers. IEEE Trans Ultrason Ferroelectr Freq Control 49:159–168CrossRef
Zurück zum Zitat Caronti A, Majjad H, Ballandras S, Caliano G, Carotenuto R, Iula A, Foglietti V, Pappalardo M (2002b) Vibration maps of capacitive micromachined ultrasonic transducers by laser interferometry. IEEE Trans Ultrason Ferroelectr Freq Control 49:289–292CrossRef Caronti A, Majjad H, Ballandras S, Caliano G, Carotenuto R, Iula A, Foglietti V, Pappalardo M (2002b) Vibration maps of capacitive micromachined ultrasonic transducers by laser interferometry. IEEE Trans Ultrason Ferroelectr Freq Control 49:289–292CrossRef
Zurück zum Zitat Certon D, Ternifi R, Boulmea A, Legros M, Minonzio JG, Talmant M, Patat F, Remenieras JP (2013) Low frequency cMUT technology: application to measurement of brain movement and assessment of bone quality. IRBM 34:159–166CrossRef Certon D, Ternifi R, Boulmea A, Legros M, Minonzio JG, Talmant M, Patat F, Remenieras JP (2013) Low frequency cMUT technology: application to measurement of brain movement and assessment of bone quality. IRBM 34:159–166CrossRef
Zurück zum Zitat Ergun A, Huang Y, Zhuang X, Oralkan O, Yaralıoglu GG, Khuri Yakub BT (2005) Capacitive Micromachined Ultrasonic Transducers: fabrication Technology. IEEE Trans Ultrason Ferroelectr Freq Control 52:2242–2258CrossRef Ergun A, Huang Y, Zhuang X, Oralkan O, Yaralıoglu GG, Khuri Yakub BT (2005) Capacitive Micromachined Ultrasonic Transducers: fabrication Technology. IEEE Trans Ultrason Ferroelectr Freq Control 52:2242–2258CrossRef
Zurück zum Zitat Hadjiloucas S, Walker GC, Bowen JW, Karatzas LS (2009) Performance limitations of piezoelectric and force feedback electrostatic transducers in different applications. J Phys Conf Ser 178:1–6 Hadjiloucas S, Walker GC, Bowen JW, Karatzas LS (2009) Performance limitations of piezoelectric and force feedback electrostatic transducers in different applications. J Phys Conf Ser 178:1–6
Zurück zum Zitat Haller M, Khuri-Yakub BT (1994) A Surface Micromachined Electrostatic Ultrasonic Air Transducer. IEEE Ultrason Symp: 1241–1244 Haller M, Khuri-Yakub BT (1994) A Surface Micromachined Electrostatic Ultrasonic Air Transducer. IEEE Ultrason Symp: 1241–1244
Zurück zum Zitat Johnson J, Oralkan O, Demirci U, Ergun S, Karaman M, Khuri-Yakub P (2002) Medical imaging using capacitive micromachined ultrasonic transducer arrays. Ultrasonics 40:471–476CrossRef Johnson J, Oralkan O, Demirci U, Ergun S, Karaman M, Khuri-Yakub P (2002) Medical imaging using capacitive micromachined ultrasonic transducer arrays. Ultrasonics 40:471–476CrossRef
Zurück zum Zitat Khuri-Yakub BT, Cheng CH, Degertekin FL, Ergun S, Hansen S, Jin XC, Oralkan O (2000) Silicon micromachined ultrasonic transducers. Jpn J Appl Phys 39:2883–2887CrossRef Khuri-Yakub BT, Cheng CH, Degertekin FL, Ergun S, Hansen S, Jin XC, Oralkan O (2000) Silicon micromachined ultrasonic transducers. Jpn J Appl Phys 39:2883–2887CrossRef
Zurück zum Zitat Ladabaum I, Jin X, Soh HT, Atalar A, Khuri-Yakub BT (1998) Surface Micromachined Capacitive Ultrasonic Transducers. IEEE Trans Ultrason Ferroelectr Freq Control 45:678–690CrossRef Ladabaum I, Jin X, Soh HT, Atalar A, Khuri-Yakub BT (1998) Surface Micromachined Capacitive Ultrasonic Transducers. IEEE Trans Ultrason Ferroelectr Freq Control 45:678–690CrossRef
Zurück zum Zitat Logan AS, Wong LL, Yeow JT (2011) A 1-D capacitive micromachined ultrasonic transducer imaging array fabricated with a silicon–nitride-based fusion process. IEEE/ASME Trans Mech 16:861–865CrossRef Logan AS, Wong LL, Yeow JT (2011) A 1-D capacitive micromachined ultrasonic transducer imaging array fabricated with a silicon–nitride-based fusion process. IEEE/ASME Trans Mech 16:861–865CrossRef
Zurück zum Zitat Mason WP (1942) Electromechanical transducers and wave filters. D. Van Nostrand Company, New Jersey Mason WP (1942) Electromechanical transducers and wave filters. D. Van Nostrand Company, New Jersey
Zurück zum Zitat Olcum S, Senlik MN, Atalar A (2005) Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers. IEEE Trans Ultrason Ferroelectr Freq Control 52:2211–2219CrossRef Olcum S, Senlik MN, Atalar A (2005) Optimization of the gain-bandwidth product of capacitive micromachined ultrasonic transducers. IEEE Trans Ultrason Ferroelectr Freq Control 52:2211–2219CrossRef
Zurück zum Zitat Oralkan O, Jin X, Degertekin FL, Khuri-Yakub BT (1999) Simulation and Experimental Characterization of a 2-D Capacitive Micromachined Ultrasonic Transducer Array Element. IEEE Trans Ultrason Ferroelectr Freq Control 46:1337–1340CrossRef Oralkan O, Jin X, Degertekin FL, Khuri-Yakub BT (1999) Simulation and Experimental Characterization of a 2-D Capacitive Micromachined Ultrasonic Transducer Array Element. IEEE Trans Ultrason Ferroelectr Freq Control 46:1337–1340CrossRef
Zurück zum Zitat Park KK, Lee H, Yaralioglu GG, Ergun AS, Oralkan O, Kupnik M, Quate CF, Khuri-Yakub BT, Braun T, Ramseyer JP, Lang HP, Hegner M, Gerber C, Gimzewski JK (2007) Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen. Appl Phys Lett 91:094102CrossRef Park KK, Lee H, Yaralioglu GG, Ergun AS, Oralkan O, Kupnik M, Quate CF, Khuri-Yakub BT, Braun T, Ramseyer JP, Lang HP, Hegner M, Gerber C, Gimzewski JK (2007) Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen. Appl Phys Lett 91:094102CrossRef
Zurück zum Zitat Park KK, Lee H, Kupnik M, Oralkan O, Ramseyer JP, Lang HP, Hegner M, Gerber C, Khuri-Yakub BT (2011) Capacitive micromachined ultrasonic transducer (CMUT) as a chemical sensor for DMMP detection. Sens Actuators B 160:1120–1127CrossRef Park KK, Lee H, Kupnik M, Oralkan O, Ramseyer JP, Lang HP, Hegner M, Gerber C, Khuri-Yakub BT (2011) Capacitive micromachined ultrasonic transducer (CMUT) as a chemical sensor for DMMP detection. Sens Actuators B 160:1120–1127CrossRef
Zurück zum Zitat Rahman M, Hernandez J, Chowdhury S (2013) An Improved Analytical Method to Design CMUTs with Square Diaphragms. IEEE Trans Ultrason Ferroelectr Freq Control 60:834–845CrossRef Rahman M, Hernandez J, Chowdhury S (2013) An Improved Analytical Method to Design CMUTs with Square Diaphragms. IEEE Trans Ultrason Ferroelectr Freq Control 60:834–845CrossRef
Zurück zum Zitat Subit D, Ogam E, Shaw G, Ejima S, Cranda JR (2013) Wavelet analysis of piezoelectric transducer signals to detect rib fractures during impact tests. Int J Crashworthiness 18:251–263CrossRef Subit D, Ogam E, Shaw G, Ejima S, Cranda JR (2013) Wavelet analysis of piezoelectric transducer signals to detect rib fractures during impact tests. Int J Crashworthiness 18:251–263CrossRef
Zurück zum Zitat Tsuji Y, Kupnik M, Khuri-Yakub BT (2010) Low temperature process for CMUT fabrication with wafer bonding technique. IEEE Ultrason Symp: 551–554 Tsuji Y, Kupnik M, Khuri-Yakub BT (2010) Low temperature process for CMUT fabrication with wafer bonding technique. IEEE Ultrason Symp: 551–554
Zurück zum Zitat Welch JN, Johnson JA, Bax MR, Badr R, Shahidi R (2000) A real-time free hand 3-D ultrasound system for image-guided surgery. IEEE Ultrason Symp: 1601–1604 Welch JN, Johnson JA, Bax MR, Badr R, Shahidi R (2000) A real-time free hand 3-D ultrasound system for image-guided surgery. IEEE Ultrason Symp: 1601–1604
Zurück zum Zitat Yaralioglu G, Degertekint F, Badi M, Auld B, Khuri-Yakub BT (2000) Finite element method and normal mode modeling of capacitive micromachined saw and lamb wave transducers. IEEE Ultrason Symp: 129–132 Yaralioglu G, Degertekint F, Badi M, Auld B, Khuri-Yakub BT (2000) Finite element method and normal mode modeling of capacitive micromachined saw and lamb wave transducers. IEEE Ultrason Symp: 129–132
Metadaten
Titel
Circular membrane approximation model with the effect of the finiteness of the electrode’s diameter of MEMS capacitive micromachined ultrasonic transducers
verfasst von
Reshmi Maity
Niladri Pratap Maity
Srimanta Baishya
Publikationsdatum
11.11.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Microsystem Technologies / Ausgabe 8/2017
Print ISSN: 0946-7076
Elektronische ISSN: 1432-1858
DOI
https://doi.org/10.1007/s00542-016-3184-9

Weitere Artikel der Ausgabe 8/2017

Microsystem Technologies 8/2017 Zur Ausgabe

Neuer Inhalt