Comparison of calibration curves using the L p norm

  • General Paper
  • Published:
Accreditation and Quality Assurance Aims and scope Submit manuscript

Abstract

Interlaboratory comparisons are a fundamental task in order to provide measurements with traceability. The simplest possible scenario implies that a single traveling standard of a quantity is measured at various laboratories. A more complex scenario arises when the laboratories measure a large set of standard values pertaining to a given physical quantity or when the traveling standard is not a realization of the quantity of interest but a measuring instrument. In the last case, it might be convenient to globally compare the calibration curves provided by the laboratories. We will introduce a distance between two generic analytical curves based on the Least Power L p norm of their difference. The properties of such distance will be presented, with particular attention to its dependence on the parameter p.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. CIPM Mutual recognition of national measurement standards and of calibration and measurement certificates issued by national metrology institutes, BIPM, Sèvres, France, 1999

  2. Cox MG (2002) The evaluation of key comparison data. Metrologia 39(6):589–595. doi:10.1088/0026-1394/39/6/10

    Article  Google Scholar 

  3. http://www.thermo.com/com/cda/resources/resources_detail/1,13229,00.html

  4. Sposito VA (1982) On unbiased Lp regression estimators. J Am Stat Assoc 77:652–654. doi:10.2307/2287729

    Article  Google Scholar 

  5. Nyquist H (1983) The optimal Lp norm estimator in linear regression models. Commun Statist Theor Methods 12:2511–2524. doi:10.1080/03610928308828618

    Article  Google Scholar 

  6. Gonin R (1989) Money AH nonlinear Lp-norm estimation. Marcel Dekker, New York

    Google Scholar 

  7. Sposito VA Some properties of L p – estimators, in K. D. Lawrence and J.L. Arthur, editors, Robust Regression, Analysis and Applications, chapter 2, pp. 23–58, Marcel Dekker, New York, 1990

  8. Hwang SY (1975) On Monotonicity of Lp and lp norms. IEEE Trans Acoust Speech Signal Process ASSP-f 3:593–594

    Google Scholar 

  9. Pennecchi F, Callegaro L (2006) Between the mean and the median: the Lp estimator. Metrologia 43(3):213–219. doi:10.1088/0026-1394/43/3/004

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Francesca Pennecchi.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Callegaro, L., Pennecchi, F. & Spazzini, P.G. Comparison of calibration curves using the L p norm. Accred Qual Assur 14, 587–592 (2009). https://doi.org/10.1007/s00769-009-0525-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00769-009-0525-8

Keywords

Navigation