Skip to main content
Log in

Biochemical evaluation of an artificial anal sphincter made from shape memory alloys

  • ORIGINAL ARTICLE
  • Published:
Journal of Artificial Organs Aims and scope Submit manuscript

Abstract

Severe anal incontinence is a socially incapacitating disorder and a major unresolved clinical problem that has a considerable negative impact on quality of life. In this study, we developed a new artificial anal sphincter using shape memory alloys (SMAs) in order to improve the quality of life of such patients and evaluated the influence of this sphincter on blood serum chemistry in animal experiments. The artificial anal sphincter was driven by two Ti-Ni SMA actuators sandwiching the intestine and was implanted in three female goats. Blood was collected from the jugular vein on days 1 and 4; at weeks 1 and 2; and at months 1, 2, and 3, postoperatively. Biochemical parameters including total protein, albumin, total bilirubin, aspartate amino-transferase, blood urea nitrogen, creatinine, and C-reactive protein were examined. The time courses of total bilirubin and aspartate amino transferase of the three goats were within the baseline levels after 1 week of implantation and remained normal, demonstrating no liver function complications. The blood urea nitrogen and creatinine levels remained within the normal range, indicating no renal function complications. The total protein and albumin fluctuated within the normal range throughout the duration of this study. In these goats, it was also found that the level of C-reactive protein did not increase and that there was no stricture of the intestine where the artificial sphincter was attached. Our findings indicate that the artificial sphincter SMA demonstrated no adverse influence on blood serum chemistry and exhibited an effective system performance.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. K Nishi T Kamiyama M Wada S Amae T Ishii T Takagi Y Luo T Okuyama T Yambe Y Hayashi R Ohi (2004) ArticleTitleDevelopment of an implantable artificial anal sphincter using a shape memory alloy J Pediatr Surg 39 69–72 Occurrence Handle14694374 Occurrence Handle10.1016/j.jpedsurg.2003.09.009

    Article  PubMed  Google Scholar 

  2. CA Hajivassiliou KB Carter IG Finlay (1997) ArticleTitleBiomechanical evaluation of an artificial anal sphincter prosthesis J Med Eng Technol 21 89–95 Occurrence Handle9222949 Occurrence Handle1:STN:280:DyaK2szms1Wguw%3D%3D Occurrence Handle10.3109/03091909709031153

    Article  PubMed  CAS  Google Scholar 

  3. S Amae M Wada Y Luo H Nakamura S Yoshida T Kamiyama T Yambe T Takagi S Nitta R Ohi (2001) ArticleTitleDevelopment of an implantable artificial anal sphincter by the use of a shape memory alloy ASAIO J 47 346–350 Occurrence Handle11482484 Occurrence Handle10.1097/00002480-200107000-00010 Occurrence Handle1:STN:280:DC%2BD38%2FisVGmtw%3D%3D

    Article  PubMed  CAS  Google Scholar 

  4. Y Luo M Higa S Amae T Takagi T Yambe T Okuyama H Tanaka Y Kakubari H Matsuki (2006) ArticleTitlePreclinical development of SMA artificial anal sphincters Minim Invasive Ther Allied Technol 15 241–245 Occurrence Handle16966138 Occurrence Handle10.1080/13645700600836695

    Article  PubMed  Google Scholar 

  5. Y Luo T Takagi T Okuyama S Amae M Wada K Nishi T Kamiyama T Yambe H Matsuki (2004) ArticleTitleFunctional evaluation of an artificial anal sphincter using shape memory alloys ASAIO J 50 338–343 Occurrence Handle15307544

    PubMed  Google Scholar 

  6. A Jain R Mohanka M Orloff P Abt R Kashyap J Cullen K Lansing A Bozorgzadeh (2006) ArticleTitleUniversity of Wisconsin versus histidine-tryptophan-ketoglutarate for tissue preservation in live-donor liver transplantation Exp Clin Transplant 4 451–457 Occurrence Handle16827642

    PubMed  Google Scholar 

  7. T Mussivand H Harasaki K Litwak MS Slaughter LA Gray SuffixJr TR Dowling R Mueller RG Masters PJ Hendry L Beck-Da-silva R Davies H Haddad TG Mesana WJ Keon (2003) ArticleTitleIn vivo evaluation of the biocompatibility of the totally implantable ventricular assist device (HeartSaver VAD) ASAIO J 49 459–462 Occurrence Handle12918591

    PubMed  Google Scholar 

  8. H Ortiz P Armendariz M DeMiguel MD Ruiz R Alos JV Roig (2002) ArticleTitleComplications and functional outcome following artificial anal sphincter implantation Br J Surg 89 877–881 Occurrence Handle12081737 Occurrence Handle10.1046/j.1365-2168.2002.02137.x Occurrence Handle1:STN:280:DC%2BD38zjvFCmug%3D%3D

    Article  PubMed  CAS  Google Scholar 

  9. SP Petrou DS Elliott (2001) ArticleTitleArtificial urethral sphincter for incontinence in adults Drugs Today (Barc) 37 237–244

    Google Scholar 

  10. S Schenk S Weber V Luangphakdy CR Flick JF Chen M Inoue MW Kopcak SuffixJr Y Ootaki K Doi R Dessoffy GB Hirschman NG Vitale PA Chapman SuffixJr WA Smith K Fukamachi (2003) ArticleTitleIn vivo performance and biocompatibility of the MagScrew ventricular assist device ASAIO J 49 594–598 Occurrence Handle14524571 Occurrence Handle10.1097/01.MAT.0000084107.46300.21

    Article  PubMed  Google Scholar 

  11. CJ Vaizey MA Kamm DM Gold CI Bartram S Halligan RJ Nicholls (1998) ArticleTitleClinical, physiological, and radiological study of a new purpose-designed artificial bowel sphincter Lancet 352 105–109 Occurrence Handle9672276 Occurrence Handle1:STN:280:DyaK1czjs1Shsg%3D%3D

    PubMed  CAS  Google Scholar 

  12. B Yokus DU Cakir Z Kanay T Gulten E Uysal (2006) ArticleTitleEffects of seasonal and physiological variations on the serum chemistry, vitamins and thyroid hormone concentrations in sheep J Vet Med A Physiol Pathol Clin Med 53 271–276 Occurrence Handle16901267 Occurrence Handle1:CAS:528:DC%2BD28XhtVSrsr3L

    PubMed  CAS  Google Scholar 

  13. M Es-Souni M Es-Souni H Fischer-Brandies (2001) ArticleTitleOn the transformation behaviour, mechanical properties and biocompatibility of two NiTi-based shape memory alloys: NiTi42 and NiTi42Cu7 Biomaterials 22 2153–2161 Occurrence Handle11432595 Occurrence Handle10.1016/S0142-9612(00)00406-3 Occurrence Handle1:CAS:528:DC%2BD3MXlt1KmtLo%3D

    Article  PubMed  CAS  Google Scholar 

  14. B Thierry M Tabrizian C Trepanier O Savadogo L Yahia (2000) ArticleTitleEffect of surface treatment and sterilization processes on the corrosion behavior of NiTi shape memory alloy J Biomed Mater Res 51 685–693 Occurrence Handle10880117 Occurrence Handle10.1002/1097-4636(20000915)51:4<685::AID-JBM17>3.0.CO;2-S Occurrence Handle1:CAS:528:DC%2BD3cXkvVygsL4%3D

    Article  PubMed  CAS  Google Scholar 

  15. SK Wilson JR Delk SuffixII (2005) ArticleTitleEctopic placement of AMS 800 urinary control system pressure-regulating balloon Urology 65 167–170 Occurrence Handle15667886 Occurrence Handle10.1016/j.urology.2004.09.042 Occurrence Handle1:STN:280:DC%2BD2M%2FktFegtA%3D%3D

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hongjian Liu PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Liu, H., Luo, Y., Higa, M. et al. Biochemical evaluation of an artificial anal sphincter made from shape memory alloys. J Artif Organs 10, 223–227 (2007). https://doi.org/10.1007/s10047-007-0395-y

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10047-007-0395-y

Key words

Navigation