Skip to main content

Advertisement

Log in

CAUDLES-EF: Carotid Automated Ultrasound Double Line Extraction System Using Edge Flow

  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

The evaluation of the carotid artery wall is essential for the diagnosis of cardiovascular pathologies or for the assessment of a patient’s cardiovascular risk. This paper presents a completely user-independent algorithm, which automatically extracts the far double line (lumen–intima and media–adventitia) in the carotid artery using an Edge Flow technique based on directional probability maps using the attributes of intensity and texture. Specifically, the algorithm traces the boundaries between the lumen and intima layer (line one) and between the media and adventitia layer (line two). The Carotid Automated Ultrasound Double Line Extraction System based on Edge-Flow (CAUDLES-EF) is characterized and validated by comparing the output of the algorithm with the manual tracing boundaries carried out by three experts. We also benchmark our new technique with the two other completely automatic techniques (CALEXia and CULEXsa) we previously published. Our multi-institutional database consisted of 300 longitudinal B-mode carotid images with normal and pathologic arteries. We compared our current new method with previous methods, and showed the mean and standard deviation for the three methods: CALEXia, CULEXsa, and CAUDLES-EF as 0.134 ± 0.088, 0.074 ± 0.092, and 0.043 ± 0.097 mm, respectively. Our IMT was slightly underestimated with respect to the ground truth IMT, but showed a uniform behavior over the entire database. Regarding the Figure of Merit (FoM), CALEXia and CULEXsa showed the values of 84.7% and 91.5%, respectively, while our new approach, CAUDLES-EF, performed the best at 94.8%, showing a good improvement compared to previous methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

References

  1. Amato M, et al: Carotid intima-media thickness by B-mode ultrasound as surrogate of coronary atherosclerosis: correlation with quantitative coronary angiography and coronary intravascular ultrasound findings. European Heart Journal 28(17):2094–101, 2007

    Article  PubMed  Google Scholar 

  2. Rosvall M, et al: Incidence of stroke is related to carotid IMT even in the absence of plaque. Atherosclerosis 179(2):325–31, 2005

    Article  PubMed  CAS  Google Scholar 

  3. Saba, L. and G. Mallarini, A comparison between NASCET and ECST methods in the study of carotids Evaluation using Multi-Detector-Row CT angiography. Eur J Radiol, 2009

  4. Touboul PJ, et al: Mannheim carotid intima-media thickness consensus (2004–2006). An update on behalf of the Advisory Board of the 3 rd and 4th Watching the Risk Symposium, 13th and 15th European Stroke Conferences, Mannheim, Germany, 2004, and Brussels, Belgium, 2006. Cerebrovasc Dis 23(1):75–80, 2007

    Article  PubMed  Google Scholar 

  5. Touboul PJ, et al: Mannheim intima-media thickness consensus. Cerebrovasc Dis 18(4):346–9, 2004

    Article  PubMed  Google Scholar 

  6. Delsanto S, et al: CULEX-completely user-independent layers extraction: ultrasonic carotid artery images segmentation. Conf Proc IEEE Eng Med Biol Soc 6:6468–71, 2005

    PubMed  Google Scholar 

  7. Delsanto S, et al: Characterization of a Completely User-Independent Algorithm for Carotid Artery Segmentation in 2-D Ultrasound Images. Instrumentation and Measurement, IEEE Transactions on 56(4):1265–1274, 2007

    Article  Google Scholar 

  8. Molinari F, et al: Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. Journal of Mechanics in Medicine and Biology 9(4):481–505, 2009

    Article  Google Scholar 

  9. Molinari F, Zeng G, Suri JS: An integrated approach to computer- based automated tracing and its validation for 200 common carotid arterial wall ultrasound images: A new technique. J Ultras Med 29:399–418, 2010

    Google Scholar 

  10. Molinari F, Zeng G, Suri JS: Intima-media thickness: setting a standard for completely automated method for ultrasound. IEEE Transaction on Ultrasonics Ferroelectrics and Frequency Control 57(5):1112–1124, 2010

    Article  Google Scholar 

  11. Zhen, Y., et al. Four image interpolation techniques for ultrasound breast phantom data acquired using Fischer's full field digital mammography and ultrasound system (FFDMUS): a comparative approach. in Image Processing, 2005. ICIP 2005. IEEE International Conference on. 2005

  12. Loizou CP, et al: Comparative evaluation of despeckle filtering in ultrasound imaging of the carotid artery. Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on 52(10):1653–1669, 2005

    Article  Google Scholar 

  13. Loizou CP, et al: Quality evaluation of ultrasound imaging in the carotid artery based on normalization and speckle reduction filtering. Med Biol Eng Comput 44(5):414–26, 2006

    Article  PubMed  CAS  Google Scholar 

  14. Ma, W.Y. and B.S. Manjunath. Edge Flow: A Framework of Boundary Detection and Image Segmentation. in Computer Society Conference on Computer Vision and Pattern Recognition. 1997. San Juan

  15. Suri JS, Haralick RM, Sheehan FH: Greedy algorithm for error correction in automatically produced boundaries from low contrast ventriculograms. Pattern Analysis and Applications 3(1):39–60, 2000

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Filippo Molinari.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Molinari, F., Meiburger, K.M., Zeng, G. et al. CAUDLES-EF: Carotid Automated Ultrasound Double Line Extraction System Using Edge Flow. J Digit Imaging 24, 1059–1077 (2011). https://doi.org/10.1007/s10278-011-9375-0

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10278-011-9375-0

Keywords

Navigation