Abstract
A nonlinear dynamic morphometric model of breathing mechanics during artificial ventilation is described. On the basis of the Weibel symmetrical representation of the tracheobronchial tree, the model accurately accounts for the geometrical and mechanical characteristics of the conductive zone and packs the respiratory zone into a viscoelastic Voigt body. The model also accounts for the main mechanisms limiting expiratory flow (wave speed limitation and viscous flow limitation), in order to reproduce satisfactorily, under dynamic conditions, the expiratory flow limitation phenomenon occurring in normal subjects when the difference between alveolar pressure and tracheal pressure (driving pressure) is high. Several expirations characterized by different levels of driving pressure are simulated and expiratory flow limitation is detected by plotting the isovolume pressure–flow curves. The model is used to study the time course of resistance and total cross-sectional area as well as the ratio of fluid velocity to wave speed (speed index), in conductive airway generations. The results highlight that the coupling between dissipative pressure losses and airway compliance leads to onset of expiratory flow limitation in normal lungs when driving pressure is increased significantly by applying a subatmospheric pressure to the outlet of the ventilator expiratory channel; wave speed limitation becomes predominant at still higher driving pressures.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Avanzolini, G., and P. Barbini. A versatile identification method applied to analysis of respiratory mechanics. IEEE Trans. Biomed. Eng. 31:520–526, 1984.
Barbini, P., G. Cevenini, and G. Avanzolini. Nonlinear mechanisms determining expiratory flow limitation in mechanical ventilation: A model-based interpretation. Ann. Biomed. Eng. 31:908–916, 2003.
Barbini, P., G. Cevenini, F. Bernardi, M. R. Massai, G. Gnudi, and G. Avanzolini. Effect of compliant intermediate airways on total respiratory resistance and elastance in mechanical ventilation. Med. Eng. Phys. 23:185–194, 2001.
Barbini, P., G. Cevenini, K. R. Lutchen, and M. Ursino. Estimating respiratory mechanical parameters of ventilated patients: A critical study in the routine intensive-care unit. Med. Biol. Eng. Comput. 32:153–160, 1994.
Dawson, S. V., and E. A. Elliott. Wave-speed limitation on expiratory flow—A unifying concept. J. Appl. Physiol. 43:498–515, 1977.
D’Angelo, E., E. Calderini, G. Torri, F. M. Robatto, D. Bono, and J. Milic-Emili. Respiratory mechanics in anaesthetized paralysed humans: Effects of flow, volume and time. J. Appl. Physiol. 67:2556–2564, 1989.
Elad, D., R. D. Kamm, and A. H. Shapiro. Choking phenomena in a lung-like model. J. Biomech. Eng. 109:1–9, 1987.
Fung, Y. C. Biomechanics: Mechanical Properties of Living Tissues. New York: Springer-Verlag, 1993.
Ginzburg, I., and D. Elad. Dynamic model of the bronchial tree. J. Biomed. Eng. 15:283–288, 1993.
Horsfield, K., G. Dart, D. E. Olson, G. F. Filley, and G. Cumming. Models of the human bronchial tree. J. Appl. Physiol. 31:207–217, 1971.
Hughes, J. M., F. G. Hoppin, and J. Mead. Effect of lung inflation on bronchial length and diameter in excised lungs. J. Appl. Physiol. 32:25–35, 1972.
Hyatt, R. E., T. A. Wilson, and Y. Bar. Prediction of maximal expiratory flow in excised human lungs. J. Appl. Physiol. 48:991–998, 1980.
Hyatt, R. E., J. R. Rodarte, T. A. Wilson, and R. K. Lambert. Mechanisms of expiratory flow limitation. Ann. Biomed. Eng. 9:489–499, 1981.
Hyatt, R. E. Expiratory flow limitation. J. Appl. Physiol. 55:1–7, 1983.
Kaczka, D. W., E. P. Ingenito, E. Israel, and K. R. Lutchen. Airway and lung tissue mechanics in asthma. Effects of albuterol. Am. J. Respir. Crit. Care Med. 159:169–178, 1999.
Kaczka, D. W., E. P. Ingenito, S. C. Body, S. E. Duffy, S. J. Mentzer, M. M. DeCamp, and K. R. Lutchen. Inspiratory lung impedance in COPD: Effects of PEEP and immediate impact of lung volume reduction surgery. J. Appl. Physiol. 90:1833–1841, 2001.
Lambert, R. K., T. A. Wilson, R. E. Hyatt, and J. R. Rodarte. A computational model for expiratory flow. J. Appl. Physiol. 52:44–56, 1982.
Lambert, R. K. Bronchial mechanical properties and maximal expiratory flows. J. Appl. Physiol. 62:2426–2435, 1987.
Lambert, R. K. A new computational model for expiratory flow from nonhomogeneous human lungs. J. Biomech. Eng. 111:200–205, 1989.
Lorino, A. M., H. Lorino, and A. Harf. A synthesis of Otis, Mead, and Mount mechanical respiratory models. Respir. Physiol. 97:123–133, 1994.
Lourens, M. S., B. van den Berg, H. C. Hoogsteden, and J. M. Bogaard. Flow-volume curves as measurement of respiratory mechanics during ventilatory support: the effect of the exhalation valve. Intensive Care Med. 25:799–804, 1999.
Lourens, M. S., B. van den Berg, A. F. M. Verbraak, H. C. Hoogsteden, and J. M. Bogaard. Effect of series of resistance levels on flow limitation in mechanically ventilated COPD patients. Respir. Physiol. 127:39–52, 2001.
Lourens, M. S., B. van den Berg, H. C. Hoogsteden, and J. M. Bogaard. Detection of flow limitation in mechanically ventilated patients. Intensive Care Med. 27:1312–1320, 2001.
Lutchen, K. R. Optimal selection of frequencies for estimating parameters from respiratory impedance data. IEEE Trans. Biomed. Eng. 35:607–617, 1988.
Macklem, P. T. The mechanics of breathing. Am. J. Respir. Crit. Care Med. 157:S88–S94, 1998.
Nucci, G., S. Tessarin, and C. Cobelli. A morphometric model of lung mechanics for time-domain analysis of alveolar pressures during mechanical ventilation. Ann. Biomed. Eng. 30:537–545, 2002.
Nucci, G., B. Suki, and K. R. Lutchen. Modeling airflow-related shear stress during heterogeneous constriction and mechanical ventilation. J. Appl. Physiol. 95: 348–356, 2003.
Nunn, J. F. Applied Respiratory Physiology. London: Butterworths, 1987.
Pardaens, J., K. P. van de Woestijne, and J. Clément. A physical model of expiration. J. Appl. Physiol. 33:479–490, 1972.
Pedersen, O. F., H. J. L. Brackel, J. M. Bogaard, and K. F. Kerrebijn. Wave-speed-determined flow limitation at peak flow in normal and asthmatic subjects. J. Appl. Physiol. 83:1721–1732, 1997.
Pedley, T. J., R. C. Schroter, and M. F. Sudlow. The prediction of pressure drop and variation of resistance within the human bronchial airways. Respir. Physiol. 9:387–405, 1970.
Polak, A. G., and K. R. Lutchen. Computational model for forced expiration from asymmetric normal lungs. Ann. Biomed. Eng. 31:891–907, 2003.
Polese, G., E. Angelo, A. Rossi, and J. Milic-Emili. Effect of inspiratory flow waveform on work on endotracheal tubes: A model analysis. Intensive Care Med. 25:503–507, 1999.
Rohrer, F. Der stroemungswiderstand in den menschlichen atemwegen und der einfluss der unregelmaessigen verzweigung des bronchialsystems auf den atmungsverlauf in verschiedenen lungenbezirken. Arch. Ges. Physiol. 162:225–229, 1915.
Shapiro, A. H. Steady flow in collapsible tubes. Trans. ASME 126–147, 1977.
Similowski, T., and J. H. T. Bates. Two-compartment modelling of respiratory system mechanics at low frequencies: Gas redistribution or tissue rheology? Eur. Respir. J. 4:353–358, 1991.
Smaldone, G. C., and P. L. Smith. Location of flow-limiting segments via airway catheters near residual volume in humans. J. Appl. Physiol. 59:502–508, 1985.
Sullivan, M., J. Paliotta, and M. Saklad. Endotracheal tube as a factor in measurement of respiratory mechanics. J. Appl. Physiol. 41:590–592, 1976.
Valta, P., C. Corbeil, A. Lavoie, R. Campodonico, N. Koulouris, M. Chasse, J. Braidy, and J. Milic-Emili. Detection of expiratory flow limitation during mechanical ventilation. Am. J. Respir. Crit. Care Med. 150:1311–1317, 1994.
Weibel, E. R. Morphometry of the Human Lung. Berlin: Springer-Verlag, 1963.
Webster, J. G. Medical Instrumentation–Application and Design. Boston: Houghton Mifflin Company, 1992.
West, J. B. Respiratory physiology–The essentials, 5th ed. Baltimore: Williams & Wilkins, 1994.
West, J. B. Pulmonary Pathophysiology–The Essentials, 5th ed. Baltimore: Williams & Wilkins, 1998.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Barbini, P., Brighenti, C., Cevenini, G. et al. A Dynamic Morphometric Model of the Normal Lung for Studying Expiratory Flow Limitation in Mechanical Ventilation. Ann Biomed Eng 33, 518–530 (2005). https://doi.org/10.1007/s10439-005-2511-6
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s10439-005-2511-6