Linear Elastic Properties of the Facial Soft Tissues Using an Aspiration Device: Towards Patient Specific Characterization

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Biomechanical modeling of the facial soft tissue behavior is needed in aesthetic or maxillo-facial surgeries where the simulation of the bone displacements cannot accurately predict the visible outcome on the patient’s face. Because these tissues have different nature and elastic properties across the face, depending on their thickness, and their content in fat or muscle, individualizing their mechanical parameters could increase the simulation accuracy. Using a specifically designed aspiration device, the facial soft tissues deformation is measured at four different locations (cheek, cheekbone, forehead, and lower lip) on 16 young subjects. The stiffness is estimated from the deformations generated by a set of negative pressures using an inverse analysis based on a Neo Hookean model. The initial Young’s modulus of the cheek, cheekbone, forehead, and lower lip are respectively estimated to be 31.0 kPa ± 4.6, 34.9 kPa ± 6.6, 17.3 kPa ± 4.1, and 33.7 kPa ± 7.3. Significant intra-subject differences in tissue stiffness are highlighted by these estimations. They also show important inter-subject variability for some locations even when mean stiffness values show no statistical difference. This study stresses the importance of using a measurement device capable of evaluating the patient specific tissue stiffness during an intervention.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5

Similar content being viewed by others

References

  1. Ansys. Theory Reference. Ansys Manual, Release 5.6, 1999.

  2. Ariji, Y., M. Nakayama, W. Nishiyama, and E. Ariji. Applications of sonographic elastography to the oral and maxillofacial region. J. Radiol. Radiat. Ther. 2(2):1049–1057, 2014.

    Google Scholar 

  3. Barbarino, G. G., M. Jabareen, J. Trzewik, A. Nkengne, G. Stamatas, and E. Mazza. Development and validation of a three-dimensional finite element model of the face. J. Biomech. Eng. 131(4):041006–041011, 2009.

    Article  PubMed  CAS  Google Scholar 

  4. Barbarino, G. G., M. Jabareen, and E. Mazza. Experimental and numerical study on the mechanical behavior of the superficial layers of the face. Skin Res. Technol. 17(4):434–444, 2011.

    Article  PubMed  Google Scholar 

  5. Bickel, B., P. Kaufmann, M. Skouras, B. Thomaszewski, D. Bradley, T. Beeler, P. Jackson, S. Marschner, W. Matusik, and M. Gross. Physical face cloning. ACM Trans. Gr. SIGGRAPH 31(4):118:1–118:10, 2012.

    Google Scholar 

  6. Chabanas, M., Y. Payan, C. Marécaux, P. Swider, and F. Boutault. Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. Lect. Notes Comput. Sci. 3078:19–27, 2004.

    Article  Google Scholar 

  7. Cua, A. B., K. P. Wilhelm, and H. I. Maibach. Elastic properties of human skin: relation to age, sex, and anatomical region. Arch. Dermatol. Res. 282(5):283–288, 1990.

    Article  PubMed  CAS  Google Scholar 

  8. Flynn, C., A. Taberner, P. Nielsen, and S. Fels. Simulating the three-dimensional deformation of in vivo facial skin. J. Mech. Behav. Biomed. Mater. 28:484–494, 2013.

    Article  PubMed  Google Scholar 

  9. Gerard, J. M., J. Ohayon, V. Luboz, P. Perrier, and Y. Payan. Non linear elastic properties of the lingual and facial tissues assessed by indentation technique. Application to the biomechanics of speech production. Med. Eng. Phys. 27(10):884–892, 2005.

    Article  PubMed  CAS  Google Scholar 

  10. Hendriks, F. M., D. Brokken, C. W. J. Oomens, D. L. Bader, and F. P. T. Baaijens. The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experiments. Med. Eng. Phys. 28:259–266, 2006.

    Article  PubMed  CAS  Google Scholar 

  11. Hollenstein, M., M. Bajka, B. Röhrnbauer, S. Badir, and E. Mazza. Measuring the in vivo behavior of soft tissue and organs using the aspiration device. Soft tissue biomechanical modeling for computer assisted surgery, studies in mechanobiology. Tissue Eng. Biomater. 11:201–228, 2012.

    Google Scholar 

  12. Keeve, E., S. Girod, R. Kikinis, and B. Girod. Deformable modeling of facial tissue for craniofacial surgery simulation. J. Comput. Aided Surg. 3:228–238, 1998.

    Article  CAS  Google Scholar 

  13. Kerdok, A. E., M. P. Ottensmeyer, and R. D. Howe. Effects of perfusion on the viscoelastic characteristics of liver. J. Biomech. 39(12):2221–2231, 2006.

    Article  PubMed  Google Scholar 

  14. Koch R., S. Roth, M. Gross, A. Zimmermann, and H. Sailer. A Framework for Facial Surgery Simulation. Technical Report 326, ETH Zurich, 1999.

  15. Lapeer, R. J., P. D. Gasson, and V. Karri. A hyperelastic finite-element model of human skin for interactive real-time surgical simulation. IEEE Trans. Biomed. Eng. 58(4):1013–1022, 2011.

    Article  PubMed  Google Scholar 

  16. Luboz, V., E. Promayon, G. Chagnon, T. Alonso, D. Favier, C. Barthod, and Y. Payan. Validation of a Light Aspiration Device for in vivo Soft Tissue Characterization (LASTIC). Soft Tissue Biomechanical Modeling for Computer Assisted Surgery. Berlin: Springer, pp. 243–256, 2012.

    Book  Google Scholar 

  17. Nazari, M. A., P. Perrier, M. Chabanas, and Y. Payan. Shaping by stiffening: a modeling study for lips. Mot. Control 15(1):141–168, 2011.

    Google Scholar 

  18. Ryu, H. S., Y. H. Joo, S. O. Kim, K. C. Park, and S. W. Youn. Influence of age and regional differences on skin elasticity as measured by the Cutometer. Skin Res. Technol. 14(3):354–358, 2008.

    Article  PubMed  Google Scholar 

  19. Schiavone P., T. Boudou, E. Promayon, P. Perrier, and Y. Payan. A light sterilizable pipette device for the in vivo estimation of human soft tissues constitutive laws. Proceedings of the 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, IEEE EMBS 2008, pp. 4298–4301, 2008.

  20. Schiavone, P., F. Chassat, T. Boudou, E. Promayon, F. Valvidia, and Y. Payan. In vivo measurement of human brain elasticity using a light aspiration device. Med. Image Anal. 13:673–678, 2009.

    Article  PubMed  CAS  Google Scholar 

  21. Schiavone, P., E. Promayon, and Y. Payan. LASTIC: a light aspiration device for in vivo soft tissue characterization. Lect. Notes Comput. Sci. 5958:1–10, 2010.

    Article  Google Scholar 

  22. Welch, B. L. The generalization of “Student’s” problem when several different population variances are involved. Biometrika 34(1–2):28–35, 1947.

    PubMed  CAS  Google Scholar 

  23. Zachow, S., E. Gladiline, H. Hege, and P. Deuflhard. Finite element simulation for soft tissue prediction. In: Computer Assisted Radiology and Surgery, CARS’00, edited by H. Lemke, and et al. San Francisco: Elsevier, 2000, pp. 23–28.

    Google Scholar 

Download references

Acknowledgments

We would like to thank Jacques Ohayon (TIMC-IMAG) for his contribution to this work and especially his help to design LASTIC and the process to estimate the stiffness modulus.

Conflict of interest

None.

Funding

This work was supported by French state funds managed by the ANR within the Investissements d’Avenir programme (Labex CAMI) under reference ANR-11-LABX-0004.

Ethical Approval

This study was conducted according to the principles expressed in the Declaration of Helsinki and all participants gave their written informed consent. Ethical approval was given by the CERNI committee under the reference 2013-11-19-30.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Y. Payan.

Additional information

Associate Editor Amit Gefen oversaw the review of this article.

Electronic supplementary material

Below is the link to the electronic supplementary material.

Electronic supplementary material 1 (PDF 1005 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Luboz, V., Promayon, E. & Payan, Y. Linear Elastic Properties of the Facial Soft Tissues Using an Aspiration Device: Towards Patient Specific Characterization. Ann Biomed Eng 42, 2369–2378 (2014). https://doi.org/10.1007/s10439-014-1098-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-014-1098-1

Keywords

Navigation