A New Venous Entry Detection Method Based on Electrical Bio-impedance Sensing

  • Medical Robotics
  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

Peripheral intravenous catheterization (PIVC) is frequently required for various medical treatments. Over 1 billion PIVC operations are performed per year in the United States alone. However, this operation is characterized by a very low success rate, especially amongst pediatric patients. Statistics show that only 53% of first PIVC attempts are successful in pediatric patients. Since their veins are small and readily rupture, multiple attempts are commonly required before successfully inserting the catheter into the vein. This article presents and evaluates a novel venous entry detection method based on measuring the electrical bio-impedance of the contacting tissue at the tip of a concentric electrode needle (CEN). This detection method is then implemented in the design of a clinical device called smart venous entry indicator (SVEI), which lights up a LED to indicate the venous entry when the measured value is within the range of blood. To verify this detection method, two experiments are conducted. In the first experiment, we measured the bio-impedance during the insertion of a CEN into a rat’s tail vein with different excitation frequencies. Then three classifiers are tested to discriminate blood from surrounding tissues. The experimental results indicate that with 100 kHz excitation frequency the blood bio-impedance can be identified with accuracy nearly 100%, demonstrating the feasibility and reliability of the proposed method for venous entry detection. The second experiment aims to assess the impact of SVEI on PIVC performance. Ten naive subjects were invited to catheterize a realistic baby arm phantom. The subjects are equally divided into two groups, where one group does PIVC with SVEI and the other group uses an ordinary IV catheter. The results show that subjects using SVEI can achieve much higher success rates (86%) than those performing PIVC in a conventional way (12%). Also, all subjects assisted by SVEI succeeded in their first trials while no one succeed in their first attempt using the conventional unassisted system. These results demonstrate the proposed detection method has great potential to improve pediatric PIVC performance, especially for non-expert clinicians. This supports further investment towards clinical validation of the technology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8

Similar content being viewed by others

References

  1. Ad5933 datasheet document (2013). http://www.analog.com/media/en/technical-documentation/data-sheets/AD5933.pdf

  2. Andreuccetti, D., Fossi, R., Petrucci, C. An internet resource for the calculation of the dielectric properties of body tissues in the frequency range 10 hz-100 ghz. Internet document, 1997.

  3. Brewer, R.: Improving peripheral iv catheterization through robotics: From simple assistive devices to a fully-autonomous system. Doctor of Philosophy, Stanford University (2015).

  4. Chen, A., Nikitczuk, K., Nikitczuk, J., Maguire, T., Yarmush, M.: Portable robot for autonomous venipuncture using 3d near infrared image guidance. Technology 1(01), 72–87 (2013).

    Article  PubMed  PubMed Central  Google Scholar 

  5. Cheng, Z., Davies, B.L., Caldwell, D.G., Mattos, L.S. A venipuncture detection system for robot-assisted intravenous catheterization. In: 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob), pp. 80–86. IEEE, 2016.

  6. Cheng, Z., Davies, B.L., Caldwell, D.G., Barresi, G., Xu, Q., Mattos, L.S.: A hand-held robotic device for peripheral intravenous catheterization. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 231(12), 1165–1177 (2017).

    Article  Google Scholar 

  7. Frey, A.M.: Success rates for peripheral iv insertion in a children’s hospital. Journal of Infusion Nursing 21(3), 160–165 (1998).

    CAS  Google Scholar 

  8. Haas, N.A.: Clinical review: vascular access for fluid infusion in children. Critical care 8(6), 1 (2004).

    Article  Google Scholar 

  9. Hernandez, D.J., Sinkov, V.A., Roberts, W.W., Allaf, M.E., Patriciu, A., Jarrett, T.W., Kavoussi, L.R., Stoianovici, D.: Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access. The Journal of urology 166(4), 1520–1523 (2001).

    Article  CAS  PubMed  Google Scholar 

  10. Jacobson, A.F., Winslow, E.H.: Variables influencing intravenous catheter insertion difficulty and failure: an analysis of 339 intravenous catheter insertions. Heart & Lung: The Journal of Acute and Critical Care 34(5), 345–359 (2005).

    Article  Google Scholar 

  11. Kalra, A. Iv insertion technique in infants and small children, 2016. https://www.youtube.com/watch?v=bu5zgfZFViY.

  12. Kalvøy, H., Frich, L., Grimnes, S., Martinsen, Ø.G., Hol, P.K., Stubhaug, A.: Impedance-based tissue discrimination for needle guidance. Physiological measurement 30(2), 129 (2009).

    Article  PubMed  Google Scholar 

  13. Khalil, S.F., Mohktar, M.S., Ibrahim, F.: The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases. Sensors 14(6), 10895–10928 (2014).

    Article  PubMed  Google Scholar 

  14. Kuensting, L.L., DeBoer, S., Holleran, R., Shultz, B.L., Steinmann, R.A., Venella, J.: Difficult venous access in children: taking control. Journal of Emergency Nursing 35(5), 419–424 (2009).

    Article  PubMed  Google Scholar 

  15. Larsen, P., Eldridge, D., Brinkley, J., Newton, D., Goff, D., Hartzog, T., Saad, N.D., Perkin, R.: Pediatric peripheral intravenous access: does nursing experience and competence really make a difference? Journal of Infusion Nursing 33(4), 226–235 (2010).

    Article  PubMed  Google Scholar 

  16. Martinsen, O.G., Grimnes, S.: Bioimpedance and bioelectricity basics. Academic Press, (2011)

    Google Scholar 

  17. Mialich, M.S., Sicchieri, J.M.F., Junior, A.A.J.: Analysis of body composition: a critical review of the use of bioelectrical impedance analysis. International Journal of Clinical Nutrition 2(1), 1–10 (2014).

    Google Scholar 

  18. Nafiu, O.O., Burke, C., Cowan, A., Tutuo, N., Maclean, S., Tremper, K.K.: Comparing peripheral venous access between obese and normal weight children. Pediatric Anesthesia 20(2), 172–176 (2010).

    Article  Google Scholar 

  19. Ogden-Grable, H., Gill, G.W.: Phlebotomy puncture juncture: preventing phlebotomy errorspotential for harming your patients. Laboratory Medicine 36(7), 430–433 (2005).

    Article  Google Scholar 

  20. Riera, A., Langhan, M., Northrup, V., Santucci, K., Chen, L.: Remember the saphenous: ultrasound evaluation and intravenous site selection of peripheral veins in young children. Pediatric emergency care 27(12), 1121–1125 (2011).

    Article  PubMed  Google Scholar 

  21. Saito, H., Mitsubayashi, K., Togawa, T.: Detection of needle puncture to blood vessel by using electric conductivity of blood for automatic blood sampling. Sensors and Actuators A: Physical 125(2), 446–450 (2006).

    Article  CAS  Google Scholar 

  22. Schoevaerdts, L., Esteveny, L., Gijbels, A., Smits, J., Ourak, M., Borghesan, G., Reynaerts, D., Vander Poorten, E. Development of a new bio-impedance sensor to detect retinal vessel punctures for retinal vein occlusion treatment. In: Proceedings of the 7th Joint Workshop on New Technologies for Computer/Robot Assisted Surgery, pp. 55–56, 2017.

  23. Shlamovitz, G.Z. Pediatric intravenous cannulation, 2015. http://emedicine.medscape.com/article/2008690-overview.

  24. Simhi, E., Kachko, L., Bruckheimer, E., Katz, J.: A vein entry indicator device for facilitating peripheral intravenous cannulation in children: a prospective, randomized, controlled trial. Anesthesia & Analgesia 107(5), 1531–1535 (2008).

    Article  Google Scholar 

  25. Trebbels, D., Fellhauer, F., Jugl, M., Haimerl, G., Min, M., Zengerle, R.: Online tissue discrimination for transcutaneous needle guidance applications using broadband impedance spectroscopy. IEEE Transactions on Biomedical Engineering 59(2), 494–503 (2012).

    Article  PubMed  Google Scholar 

  26. Troianos, C.A., Hartman, G.S., Glas, K.E., Skubas, N.J., Eberhardt, R.T., Walker, J.D., Reeves, S.T., et al.: Guidelines for performing ultrasound guided vascular cannulation: recommendations of the american society of echocardiography and the society of cardiovascular anesthesiologists. Anesthesia & Analgesia 114(1), 46–72 (2012).

    Article  Google Scholar 

  27. Vanhoutte, G., Verhoye, M., Raman, E., Roberts, M., Linden, A.: In-vivo non-invasive study of the thermoregulatory function of the blood vessels in the rat tail using magnetic resonance angiography. NMR in Biomedicine 15(4), 263–269 (2002).

    Article  CAS  PubMed  Google Scholar 

  28. yZivanovic, A., Davies, B.L.: A robotic system for blood sampling. IEEE Transactions on Information Technology in Biomedicine 4(1), 8–14 (2000).

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Dr. Monica Morini, Dr. Michele Cilli, and Federica Piccardi from the Animal Facility of Istituto Italiano di Tecnologia for assisting the in vivo animal experiment.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Zhuoqi Cheng.

Additional information

Associate Editor Daniel Elson oversaw the review of this article.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cheng, Z., Davies, B.L., Caldwell, D.G. et al. A New Venous Entry Detection Method Based on Electrical Bio-impedance Sensing. Ann Biomed Eng 46, 1558–1567 (2018). https://doi.org/10.1007/s10439-018-2025-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10439-018-2025-7

Keywords

Navigation