1 Introduction

The definition of the capacity criteria for collapse assessment of buildings is not a trivial issue (e.g., Deniz et al. 2017; Terrenzi et al. 2018). With regard to reinforced concrete (RC) buildings, several studies addressed this problem by developing a variety of collapse criteria based on physical and mechanical-empirical aspects or deterministic assumptions. The seminal work by Mwafy and Elnashai (2001) defined local and global criteria for collapse assessment of RC buildings. Local criteria are based on section flexural and shear failure, whereas three global criteria are defined by inter-story drift ratio (IDR) thresholds, sidesway collapse, and reduction in lateral strength of the pushover (PO) curve. The flexural failure was associated with the ultimate section chord rotation θu, whereas the shear failure with the ultimate shear force/strength. The sidesway condition was quantitatively defined by the pioneering work of Vamvatsikos and Cornell (2002) as the onset of the (sub-)horizontal branch of the incremental dynamic analysis (IDA) curve, i.e., when a minor increase in terms of intensity measure (IM), e.g., spectral acceleration at the fundamental period (Sa(T1)), determines a particularly significant deformation, e.g., roof drift ratio (RDR) increase. This criterion is typically used when IDAs are performed and the focus is on the condition of null lateral stiffness (Goulet et al. 2007). A more conservative condition was also suggested for the collapse prevention limit state by Vamvatsikos et al. (2003); this consisted in a reduction of 80% of the local stiffness of the IDA curve. The sidesway condition could also be referred to the building static behavior, e.g., to PO curves, which typically require a minor computational effort to be evaluated. In particular, the collapse corresponds to RDR associated with null shear strength (Vamvatsikos et al. 2003; Suita et al. 2008; Shafei et al. 2011). Analogously to the assumption related to the more conservative IDA-based collapse criterion [i.e., reduction in local stiffness of the IDA (Vamvatsikos et al. 2003)], a given strength reduction in the PO curve could define a collapse prevention limit state. As an example, 50% reduction in lateral shear strength of the PO curve was considered to define the collapse limit in recent studies (Camata et al. 2017; Magliulo et al. 2018; Ricci et al. 2018). A similar but more conservative criterion was already established by Haselton and Deierlein (2007), who defined the ultimate RDR as the ratio associated with a reduction of 20% in lateral shear strength of the PO curve.

Both local and global collapse criteria defined in the above-mentioned studies were adopted in several studies such as in Ghobarah (2004), Rossetto and Elnashai (2005), Haselton et al. (2009), and Baradan Shoraka et al. (2013). Regulations and codes often provide phenomenological criteria correlated to the qualitative response of the buildings to horizontal and vertical actions. Eurocode 8 (British Standards Institution and European Committee for Standardization 2005) establishes building performance criteria that indirectly imply the safety concerning collapse. Such criteria are based on resistance, ductility, and stability of the structural members/components. The quantitative collapse criteria supplied by the codes often refer to the local response of single members, e.g., shear strength for brittle mechanisms and chord rotation for ductile mechanisms (CEN 2005; CS.LL.PP. 2018). Therefore, the global collapse is implicitly associated with the earliest (shear or flexural) failure of members/components. This conventional condition is typically quite conservative for code-conforming buildings and far below the sidesway collapse. ASCE 7-16 (American Society of Civil Engineers 2017b) defines both global and local acceptance criteria in the framework of the nonlinear response assessment and also refers to ASCE 41 (American Society of Civil Engineers 2017a) for the collapse prevention specifications. The global criteria consist of (a) prevention of the unacceptable response and (b) assessment of IDR. The unacceptable response was defined by analytical instability or predicted demands significantly exceeding (modeling) capacities. The element-level (or local) acceptance criteria are defined considering both force- and deformation-controlled actions. Regarding local deformation-controlled mechanisms, ASCE 7–16 provides (a) a main criterion, referred to ASCE 41 (American Society of Civil Engineers 2017a), and (b) an alternative criterion based on the comparison of the mean inelastic deformation and an aliquot of the loss of gravity-load-carrying inelastic capacity, experimentally assessed. In particular, ASCE 41 (American Society of Civil Engineers 2017a) provides the formulations to evaluate (a) the plastic rotation at significant lateral force capacity (i.e., 20% or larger loss from the peak value) and (b) the plastic rotation at loss of gravity-load support. The associated acceptance criteria capacities are also supplied for collapse prevention building performance level. The reported formulations were derived from (Ghannoum and Sivaramakrishnan 2012; Ghannoum and Matamoros 2014).

A variety of empirical formulations for the chord rotation capacity at the collapse θu can be found in the literature, and the formulations developed by Biskinis and Fardis (2010a, b), as well as the ones recommended by EN1998-3:2005 (CEN 2005) and fib Model Code 2010 (MC 2010) (Beverly and International Federation for Structural Concrete 2013; Fardis 2013), are among the most referenced ones. Empirical formulations are also supplied in ASCE 41 (American Society of Civil Engineers 2017a), as previously mentioned. EN1998-3:2005 (CEN 2005) also supplies an alternative capacity formulation based on a physical approach, i.e., by assuming that the plastic part of the section curvature is uniform over a conventional length of the plastic hinge (Lpl) (Ansal 2014). The draft of new EN1998-3 (CEN 2020) explicitly defines the collapse condition as a drop of moment equal to 20% of the capping value, according to the definition of Fardis and Biskinis (2003) and Haselton and Deierlein (2007). In this draft, the empirical formulation provided in the previous version is replaced by a novel one. Codes and guidelines such as FEMA P695 (Federal Emergency Management Agency (FEMA) 2009), FEMA 356 (Federal Emergency Management Agency (FEMA) 2000) and SEAOC Vision 2000 (Structural Engineers Association Of California (SEAOC) 1995) supply global capacity criteria based on building type-based IDR thresholds.

While several studies assessed the capacity models of RC members by comparing the capacity predictions with experimental results (Borg 2015; Fusco et al. 2018; Verderame and Ricci 2018), only few studies highlighted the significance of the selection of the criteria for the assessment of the collapse of RC buildings, especially for code-conforming buildings. Mpampatsikos et al. (2008) investigated the reliability of both Eurocode 8 (CEN 2005) and Italian seismic code OPCM 3431 (Presidente del Consiglio dei Ministri 2003, 2005) for the collapse assessment of irregular nonconforming RC buildings. They considered both empirical and physical formulations for θu provided in the reference codes. The extended study by Haselton et al. (2011) assessed the seismic risk of low-to-high rise bare frame RC buildings designed according to the US regulations by assuming sidesway collapse as a capacity criterion. Similarly, Noh and Tesfamariam (2018) evaluated the collapse risk related to low- and medium-rise bare and infilled frame RC buildings designed in compliance with the Canadian Standards (CSA 2014). Terrenzi et al. (2018, 2019) analyzed a medium- and high-rise code-conforming RC building. As collapse criteria, they considered the first achievement of the ultimate chord rotation θu (empirical formulation in EN1998-3), various IDR thresholds, and a reduction of 50% in lateral shear strength Vh of the PO curve (Camata et al. 2017; Ricci et al. 2018). Di Trapani et al. (2020) carried out IDAs for the fragility and reliability assessment of a five-story code-conforming RC building. The collapse condition was defined as the lowest IDRmax among the earliest achievement of (a) ultimate chord rotation of at least one column, (b) ultimate shear capacity of at least one column, and (c) IDR equal to 6.5%. This latter criterion was associated with the projection of the top column centroid being located out of the base cross-section.

In the framework of the performance-based earthquake engineering (PBEE) approach, the different criteria are not only alternative collapse capacities, but they can also be meant as capacity criteria associated with the spectrum of collapse damage conditions. In other words, each criterion has a role within the holistic concept of the building response, and local and global criteria are expected to be somehow correlated among them. The assessment of the correlations between the local and global response highlights the qualities of the building design process. However, this issue has not been sufficiently assessed, to the authors’ knowledge. If a building is conceived and designed according to the capacity design approach, such qualities should have distinctive characteristics, such as a significant lateral displacement margin between the heavily plastic behavior and the collapse, or a reduced margin between the earliest local collapse and the global one; furthermore, a global mechanism should be observed instead of a local one. Even though several studies assessed local and global collapse of frame RC buildings, no studies, to the knowledge of the authors, defined the relationships between the local and the global response of conforming buildings.

The present study covers the literature gap associated with the assessment of both local and global collapse capacity criteria related to code-conforming moment resisting frame (MRF) RC buildings. Two orders of aspects are investigated according to the PBEE approach: (1) collapse assessment of code-conforming low-rise RC frame buildings and (2) identification and quantification of the main features of the existing collapse criteria in terms of building response and seismic risk. The collapse assessment is performed by considering a wide variety of (local and global) collapse criteria as capacity measures (Sect. 2). The case studies consist of three-story bare frame (BF), infilled frame (IF), and pilotis frame (PF) buildings (Sect. 3). They are designed for three low-to-high seismicity sites in Italy according to the Italian building code NTC 2008 (CS.LL.PP. 2008) (Sect. 3). The seismic demand is evaluated by performing nonlinear multiple-stripe analysis (MSA) (Sect. 4). The characterization of local and global collapse capacity criteria (Sect. 5) is expressed in terms of (a) demand to capacity ratios, (b) fragility curves (collapse capacity assessment), (c) estimated and target collapse margin ratios and probabilities (collapse performance evaluation), and (d) inter-capacity margin ratios.

2 Capacity criteria

2.1 Local and global criteria

Both local and global engineering demand parameters (EDPs) were considered for the definition of the performance criteria, i.e., element section chord rotation θ, inter-story drift ratio IDR, and roof drift ratio RDR. It is recalled that IDR can be expressed as the sum of the average beam and column θ of the story (e.g., Panagiotakos and Fardis 2004) and that, in the case of a building with the same story height, RDR is equal to the average of the building IDRs. The ultimate chord rotation capacities θu essentially depend on the characteristics of the members and their cross-sections. The IDR limits are typically fixed thresholds that might depend on the building typology or characteristics (e.g., Ghobarah 2004). The RDR capacities can be associated with a specific decrease in the building base shear strength Vh of the PO curves (Camata et al. 2017; Ricci et al. 2018). Table 1 summarizes the investigated collapse capacity criteria, and it reports the essential formulation related to the case study applications. In particular, θu1 (Eq. 1) and θu2 (Eqs. 2.1, 2.2, and 2.3) are the empirical and the physical formulations recommended in EN1998-3:2005 (CEN 2005), whereas θu3 (Eqs. 3.1, 3.2, and 3.3) is the empirical capacity derived from the draft of new EN1998-3 (CEN 2020); θu4 (Eqs. 4.1, 4.2, 4.3, and 4.4) was developed by Haselton and Deierlein (2007); this latter is also referred to as HD capacity in the paper. IDRu1 (Eq. 5) was recommended by FEMA 356 (Federal Emergency Management Agency (FEMA) 2000) that also complies with FEMA 273 (Federal Emergency Management Agency (FEMA) 1997), IDRu2 (Eq. 6) was proposed by Ghobarah (2004), IDRu3 (Eq. 7) is recommended by ASCE 7–16 (American Society of Civil Engineers 2017b) and also used by Rajeev and Tesfamariam (2012), IDRu4 (Eq. 8) was developed by from Di Trapani et al. (2020), and IDRu5 (Eq. 9) was recommended by FEMA P695 (Federal Emergency Management Agency (FEMA) 2009) and corroborated in the literature. In particular, IDRu5 was found to be (a) well correlated to sidesway collapse or very reduced stiffness of most engineering structures (e.g., steel frames) (Vamvatsikos and Cornell 2002; Pourreza et al. 2021), (b) an upper bound collapse capacity estimate considering both ductile and nonductile RC buildings (Gokkaya et al. 2016), and (c) consistent with collapse of non-conforming Italian RC frame buildings by a sensitivity analysis performed by O’Reilly and Sullivan (2018). Therefore, in this study, this capacity is considered to be representative of reduced or null IDA slopes and relatively representative of sidesway collapse, with regard to the set of criteria investigated in this study.

Table 1 Collapse capacity criteria assessed in the present study and formulations related to the specific applications

The selected set of IDRu thresholds is representative of the whole range of potential significant IDR values and allows assessing the variability of this parameter in relation to the other ones. Furthermore, all IDRu criteria were derived from regulation and literature recommendations and, therefore, their use consideration is more than reasonable. RDRu1 (Eq. 10) was defined by Haselton and Deierlein (2007) as ultimate deformation capacity and RDRu2 (Eq. 11) was developed in the framework of RINTC project (Camata et al. 2017; RINTC Workgroup 2018; Magliulo et al. 2018; Ricci et al. 2018). The definition of the basic parameters used in Table 1 (Eqs. 1 to 11) is reported in the Notation section for the sake of brevity, whereas the main assumptions/specifications related to the present paper are reported in Sect. 2.2.

2.2 Main assumptions and specifications

The mean values were assumed for all mechanical parameters used for the computation of the capacities. For this purpose, the partial factor γel (Eqs. 1 and 2.1) was assumed equal to one (e.g., Borg 2015). The shear span Lv (Eqs. 1, 2.1, 2.2, 2.3, 3.2, 3.3, and 4.2) was assumed to be equal to half story height in all cases (Mpampatsikos et al. 2008). A fiber analysis was implemented in MATLAB for the estimation of both yielding and ultimate curvatures φy and φu (Eqs. 2.1, 2.2, and 3.2). The yielding curvature φy was evaluated by assuming the incipient yielding of the tension bars without taking into account the concrete confinement. The failure mechanisms to be assumed for the computation of the ultimate curvature φu were selected according to the specific section equilibrium. Both concrete compression and steel tension failure conditions were considered by also including the concrete confinement. In particular, the provisions reported in EN 1992–1-1:2004 §3.1.9 (CEN 2004) were implemented for the definition of the confinement model, as well as the ultimate strain of the longitudinal reinforcement εsu and effective lateral confining stress σ2 were defined according to EN1998-3:2005 §A.3.2.2(7.a) and (7.b). Such conditions were compliant with the formulation used for the evaluation of the plastic hinge length Lpl reported in formula A.5 in EN1998-3:2005 (Eq. 2.3).

Regarding the yielding chord rotation capacity θy, it is worth noting that the draft of new EN1998-3 reports a formulation that is slightly different from the one recommended in the current version of the Eurocode. Therefore, θy was computed according to the new Eurocode draft provisions for the evaluation of θu3 (Eq. 3.2), whereas the current Eurocode formulation was considered for the computation of θu2 (Eq. 2.2). However, the different formulations supply very similar values, with differences that are negligible in all cases. Another clarification related to the draft of the new Eurocode is due. The physical capacity (θu2) is considered to be an equivalent alternative to the empirical one (θu1) within the current version of the Eurocode. Differently, the Eurocode draft recommends the empirical capacity (θu3) for all cases in which the compression zone is rectangular and at right angles to the element web, e.g., the ordinary case of rectangular section, whereas the physical capacity (θu2) is recommended for any other condition. My was evaluated considering the formulation recommended by Haselton and Deierlein (2007) and developed by Panagiotakos and Fardis (2001), which is not reported in the manuscript for the sake of brevity.

3 Case studies and building design

Three-story residential MRF RC buildings were designed as ordinary buildings according to the Italian building code NTC 2008 (CS.LL.PP. 2008), which is compliant with Eurocode (British Standards Institution and European Committee for Standardization 2005). Figure 1 shows the (a) plan and (b) elevation layouts of the frames and (c) the typical architectural plan. BF, IF, and PF buildings were considered: IF has all bays infilled, whereas PF has bare ground floor bays and all other ones are infilled. Hollow clay brick panels having a thickness equal to 300 mm were considered as a representative system of typical Italian and Mediterranean RC building infills (Verderame et al. 2019). Each building type was designed according to three different seismicity sites: (a) L’Aquila (AQ), Naples (NA), and Milan (MI). Soil type “C” (shear wave velocity in the top 30 m in the range 180–360 ms−1) and topography class 1 (level ground) were considered for all sites. The details of the seismic hazard associated with the investigated sites are reported in Table 2 i.e., maximum bedrock acceleration (ag) considering both damage limit state (SLD in Italian) and life safety limit state (SLV in Italian). A return period TR equal to 50 (475) years corresponds to the design actions related to SLD (SLV) for ordinary buildings, with 63% (10%) probability of exceedance in 50 years. The buildings were designed by performing three-dimensional response spectrum analyses according to the common practice adopted for new buildings. Both SLD and SLV conditions were considered for the design. A ductility class “B” was assumed; this is equivalent to medium ductility class DCM in Eurocode. The behavior factor resulted in 3.9 since the building was regular in both plan and elevation (Fig. 1). Concrete C28/35 and steel B450C (yielding strength equal to 450 Nmm−2) were used as design materials. Deep perimetrical beams and flat internal beams were assumed as it is common for the considered layout. The floor slabs were one-way 250 mm thick. The infills/partitions were only considered as applied masses for all buildings according to the current practice, and special design conditions were applied to PF buildings given the irregular infill distribution in elevation. In particular, the seismic actions were amplified by a factor equal to 1.4 for the ground floor columns.

Fig. 1
figure 1

a Plan and b elevation layouts of the frames and c typical architectural plan. The dimensions are in m

Table 2 Site details and design accelerations at bedrock ag related to both SLD and SLV conditions, i.e., 50 and 475 return period TR years (CS.LL.PP. 2018)

The three-dimensional models had fixed bases and rigid floor diaphragms. The stairwell elements, including the knee beams, were fully considered in the models. A cracked flexural stiffness corresponding to 0.50 and 0.75 times the gross section’s one was assumed for beams and columns, respectively. The structural details of all building members are not reported in the paper for the sake of brevity; however, more details on both design process and structural elements can be found in (RINTC Workgroup 2018). The main details of the design are summarized in Table 3, i.e., the ratio between the ground floor total column area and the total floor area \(\bar{a }\), the average of the longitudinal steel ratios related to the perimetrical (internal) beams \(\bar{{\rho }_{bp}}\) (\(\bar{{\rho }_{bi}}\)), and the average of the longitudinal steel ratios related to the ground floor columns \(\bar{{\rho }_{cg}}\). The cross-section dimensions of all structural members and the reinforcement details of the beams did not vary for BF, IF, and PF buildings for the same sites.

Table 3 Summary of the main design parameters

4 Numerical analysis

The numerical models related to the case study buildings were developed in the framework of the Italian RINTC project (RINTC Workgroup 2018; Ricci et al. 2018). Nonlinear static analyses were performed to evaluate the capacity criteria associated with RDRu1 and RDRu2. Time-history analyses were performed according to a MSA procedure to assess the seismic demand in terms of θ, IDR, and RDR.

4.1 Numerical modeling

Three-dimensional models were built in OpenSees (McKenna et al. 2000); they included the frame and stairwell members, as well as the infills when present in the building layout. The structures were fixed at the base (no soil-structure interaction); the floor diaphragms were assumed to be rigid. Since the buildings were designed according to modern capacity design criteria (NTC 2008 (CS.LL.PP. 2008), shear failure of the frame elements and inelastic response of the beam-to-column joints were expected to be prevented (e.g., Ricci et al. 2018). Therefore, the modeling did not account for these latter responses, as well as the end-offsets were not implemented in the models.

4.1.1 Bare frame and stairwell elements

A phenomenological model based on lumped plasticity was considered for all frame and stairwell elements. In particular, the inelastic response followed the peak-oriented hysteretic degradation model developed by Ibarra and Krawinkler (2005) and Ibarra et al. (2005), often referred to as IMK model. This model was available within the software database (Karavasilis et al. 2009), and it was widely used in past studies such as in (Haselton et al. 2011; Lin et al. 2013; Ercolino et al. 2018; Ricci et al. 2018; Cimmino et al. 2020; Shahnazaryan and O’Reilly 2021). The IMK model does not account for the influence of the axial force variation on the moment-rotation response, and a fixed value of the axial load has to be assumed for the determination of the modeling parameters. Each structural member was modeled as a series (Fig. 2a), composed of four nodes (two external (frame) nodes and two internal ones) and three elements between them. A zeroLength element was assigned between the frame node and the internal one for each member’s end, and an elasticBeamColumn was set between the internal nodes. The uniaxialMaterial ModIMKPeakOriented (IMK model) response was assigned to the zeroLength elements. The P-δ effects (second order geometrical effects) were also considered in the modeling.

Fig. 2
figure 2

Inelastic modeling: a global member model and b IMK backbone curve and hysteretic features of peak-oriented hysteretic response model implemented through uniaxialMaterial ModIMKPeakOriented

The modeling parameters related to ModIMKPeakOriented response consist of the backbone features and the degrading parameters. The IMK backbone (Fig. 2b) is defined for each (positive/negative) direction by effective yielding moment My, effective elastic stiffness K0, strain hardening ratio αs (i.e., hardening to effective elastic stiffness ratio), pre-capping rotation Δθp, and post-capping rotation Δθpc, whereas the degraded capacity parameters consist of the ratio κ between the residual moment capacity Mr and My and the ultimate rotation capacity θu. In Fig. 2b, θy, θc, and θr are the yielding, capping, and residual rotations, whereas MC and as are the capping moment and the capping to yielding moment ratio (i.e., Mc/My); the strain hardening ratio αs is defined by (Mc-My)/Δθp/K0 and the hardening stiffness can be expressed by αs·K0.

For each stage of the response, the hysteretic degradation of both strength and stiffness is taken into account by the parameters λ and c. An asymmetric hysteretic behavior can also be modeled by setting the rate D. For a more detailed description and discussion on the modeling parameters, please see the seminal studies by Ibarra and Krawinkler (2005), Ibarra et al. (2005), Haselton and Deierlein (2007), and Lignos et al. (2011).

The modeling assumes a unique response for the pre-yielding branch (Fig. 2b), and the effective elastic stiffness K0 should be ranging between the uncracked and the secant-to-yield one; in particular, the implemented stiffness was computed depending on the dimensionless axial force, ranging within 20–60% of the gross stiffness (RINTC Workgroup 2018). The elastic stiffness of the zeroLength element was assumed to be ten times the elasticBeamColumn one according to several studies (Ibarra and Krawinkler 2005; Ercolino et al. 2018; Iervolino et al. 2018; Magliulo et al. 2018; Ricci et al. 2018), with the series behavior equaling the global member response (Ibarra and Krawinkler 2005). The formulation proposed by Haselton and Deierlein (2007) and Haselton et al. (2008) was considered for the evaluation of the modeling parameters. The formulation details are not reported in the paper since they are well-established in the literature and available in the referenced studies. Moreover, the collapse capacity related to such formulation was already reported in Eqs. 4.1 to 4.4 (Table 1) for the definition of θu4.

The capping to yielding moment ratio as and the residual to yielding moment ratio κ were assumed to be equal to 1.13 and zero for all elements according to Haselton and Deierlein (2007). The formulation for λ was derived by Lignos et al. (2011), and c was assumed to be equaling zero. A symmetric hysteretic response was considered by assuming D equal to one.

The stairwell elements consisted of full-height and inter-floor short columns, inclined beams, and floor and inter-floor beams. Such elements were modeled analogously to the frame elements, even though some modifications were made for the inclined beams because of their peculiar geometry. In particular, the stiffness of the axial degree of freedom of the elasticBeamColumn elements (related to the inclined beams) was assumed equal to zero, and an inelastic truss element was added in parallel. An asymmetric elastic–plastic behavior was assigned to the truss element.

Mass- and initial tangent stiffness-proportional Rayleigh damping was assumed, with a damping ratio equal to 5% assigned to (a) half of the first mode frequency (due to the period elongation phenomena) and (b) second mode frequency of the prevalently translational modes. According to Ibarra and Krawinkler (2005), the damping was only assigned to the elasticBeamColumn elements (Fig. 2a). This allowed avoiding the typical issues related to the damping forces generated by the sudden stiffness variation within the plastic hinges over the plastic range behavior (Charney 2008; Ricci et al. 2018).

4.1.2 Infill panels

The presence of the infills was taken into account within the global building model by implementing their in-plane response. Each infill panel (Fig. 3a) was modeled by two symmetric independent diagonal strut elements only responding under compression (Fig. 3b).

Fig. 3
figure 3

a Geometry of an infill panel and b schematic of the frame and strut elements. The dotted black (solid grey) lines in a are representative of the axis (external edges) of the frame structure, whereas the brick pattern fields depict the infill panels. The square elements in b represent the frame nodes; the solid black lines are representative of the modeling frame elements, whereas the solid and dashed grey lines depict the modeling strut elements

The modeling was implemented according to Decanini and Fantin (1986), Bertoldi et al. (1993), Decanini et al. (2004, 2014). The equivalent strut behavior of the infills depends on the characteristics of the panel (e.g., Fig. 3a). The width of the equivalent strut element \(\bar{\omega }\) (Fig. 3b) was computed according to Smith (1962), i.e. by using Eq. (12), where K1 and K2 are experimental constants defined in Eq. (13), λh is a dimensionless relative stiffness parameter defined in Eq. (14), and dp is the equivalent strut length. In Eq. (14), Em is the equivalent elastic modulus of the infills, e is the thickness of the panel, ϕ is the strut-to-frame beam angle, Ec is the elastic modulus of the concrete, I is the moment of inertia of the columns, h is the (centerline) height of the story, and hp is the infill panel height.

$$\bar{\omega } = \left( {\frac{{{\text{K}}_{1} }}{{\lambda {\text{h}}}} + {\text{K}}_{2} } \right)d_{p}$$
(12)
$${\text{K}}_{1} \left( {{\text{K}}_{2} } \right) = \left\{ {\begin{array}{*{20}l} {1.3\left( { - 1.78} \right)} \hfill & {{\text{if}}\;\lambda {\text{h}} \le 3.14} \hfill \\ {0.707\left( {0.01} \right)} \hfill & {{\text{if }}\;3.14 \le \lambda {\text{h}} \le 7.85} \hfill \\ {0.47\left( {0.04} \right)} \hfill & {{\text{if}}\;\lambda {\text{h}} \ge 7.85} \hfill \\ \end{array} } \right.;$$
(13)
$$\lambda {\text{h}} = \sqrt[4]{{\frac{{{\text{E}}_{{\text{m}}} {\text{ e sin}}2\phi }}{{4{\text{ E}}_{{\text{c}}} {\text{ I h}}_{{\text{p}}} }}}}{\text{ h}}$$
(14)

The strut behavior is modeled by a backbone curve, defined as lateral force Hm versus displacement u (Fig. 4), and consisting in four branches: (a) elastic pre-cracking, (b) post-cracking, (c) softening, and (d) plastic (or residual). The elastic branch is defined by the cracking lateral force and displacement Hmf and uf (F in Fig. 4), whereas the peak strength condition is defined by the peak lateral force and the corresponding displacement Hmfc and ufc (FC in Fig. 4). The residual conditions are defined by the residual lateral force and displacement Hmr and ur.

Fig. 4
figure 4

Backbone curve related to the equivalent strut element (Decanini and Fantin 1986; Bertoldi et al. 1993; Decanini et al. 2004, 2014)

Hmfc was found using Eq. 15, where γm is a factor used to obtain a median value from the experimental (lognormal) estimation, and σmin is defined in Eq. 16. In particular, σmin is the minimum value among the considered failure mode compression strengths, i.e., (a) diagonal tension (σbr1), (b) sliding shear along the horizontal joints (σbr2), (c) crushing in the corner in contact with the frame (σbr3), and (d) diagonal compression (σbr4). Such failure modes describe the typical seismic response of infill panels evidenced by experimental tests and post-event surveys. The failure mode strengths σbr1 to σbr4 are defined in Eqs. (1720) where σ0 is the vertical stress due to the gravitational loads, τm0 is shear strength measured through diagonal compression tests, \({f}_{sr}\) is the sliding strength in the joints, and σm0 is the vertical compression strength measured on masonry specimens.

$${\text{H}}_{{{\text{mfc}}}} = {\upgamma }_{{\text{m}}} {{ \sigma }}_{{{\text{min}}}} {{ e \bar{\omega } cos}}\phi$$
(15)
$${\upsigma }_{{{\text{min}}}} = {\text{min}}\left\{ {{\upsigma }_{{{\text{br}}1}} ,{\upsigma }_{{{\text{br}}2}} ,{\upsigma }_{{{\text{br}}3}} ,{\upsigma }_{{{\text{br}}4}} } \right\}$$
(16)
$${\upsigma }_{{{\text{br}}1}} = \frac{{0.3{{ \sigma }}_{0} + 0.6{{ \tau }}_{{{\text{m}}0}} }}{{\frac{{{\bar{\omega }}}}{{{\text{d}}_{{\text{p}}} }}}}$$
(17)
$${\upsigma }_{{{\text{br}}2}} = \frac{{0.3{{ \sigma }}_{0} + {\text{ f}}_{{{\text{sr}}}} { }\left( {1.2{\text{ sin}}\phi + 0.45{\text{ cos}}\phi } \right)}}{{\frac{{{\bar{\omega }}}}{{{\text{d}}_{{\text{p}}} }}}}$$
(18)
$${\upsigma }_{{{\text{br}}3}} = {\upsigma }_{{{\text{m}}0}} \frac{{1.12{\text{ sin}}\phi {\text{ cos}}\phi }}{{{\text{K}}_{1} \left( {{\lambda h}} \right)^{ - 0.12} + {\text{K}}_{2} \left( {{\lambda h}} \right)^{ - 0.88} }}$$
(19)
$${\upsigma }_{{{\text{br}}4}} = {\upsigma }_{{{\text{m}}0}} \frac{{1.16{{ \sigma }}_{{{\text{m}}0}} {\text{ tan}}\phi }}{{{\text{K}}_{1} + {\text{K}}_{2} {{ \lambda h}}}}$$
(20)

Hmf and Hmr were assumed to be 0.8 and 0.35 times Hmfc, respectively, whereas the displacement limits related to the backbone curve (i.e., uf, ufc, ur) were derived from recent studies (Cardone and Perrone 2015; Sassun et al. 2016). The factor γm was assumed equal to 1.18. The elastic modulus of the infill panel Em resulted in 4.312 GPa. The vertical stress σ0 was equal to zero, and the compression strength σm0 was set equal to 6 MPa. The shear strength τm0 was assumed to be equal to \(\sqrt{{\sigma }_{m0}}\) (where \({\sigma }_{m0}\) is in Kg/cm2), resulting in 0.77 MPa, whereas the sliding strength \({f}_{sr}\) was set equal to 0.7 τm0, resulting in 0.54 MPa. Such assumptions were corroborated by other past studies (Camata et al. 2017; Terrenzi et al. 2018; Ricci et al. 2018), and widely discussed in (RINTC Workgroup 2018).

The presence of the openings within the infill panels was also taken into account by assuming a reduction in both stiffness and strength of the strut behavior, according to Decanini et al. (2014). The reduction coefficient ρo defined in Eq. (21) was applied to both the (full panel) ultimate strength Hmfc and secant stiffness Kmfc. In particular, αa and α1 are defined in Eqs. (22) and (23), respectively, where l0 and h0 are the horizontal and vertical dimensions of the opening. The presence of the opening was implemented in the global models according to the architectural layout shown in Fig. 1c.

$$\rho_{{\text{o}}} = 0.55\exp \left( { - 0.035{ }\alpha_{{\text{a}}} } \right) + 0.44\exp \left( { - 0.025{ }\alpha_{1} } \right)$$
(21)
$$\alpha_{{\text{a}}} = 100\frac{{{\text{l}}_{0} {\text{h}}_{0} }}{{{\text{l}}_{{\text{p}}} {\text{ h}}_{{\text{p}}} }}{ }$$
(22)
$$\alpha_{1} = 100\frac{{{\text{l}}_{0} }}{{{\text{l}}_{{\text{p}}} }}$$
(23)

The infill panel strut response was implemented by assigning the uniaxial Material Concrete01 behavior to the diagonal elements (Fig. 3b). In fact, this response was able to fit the backbone curve with good agreement, with particular regard to the initial elastic and the softening branches (RINTC Workgroup 2018).

4.2 Static and time history analyses

Nonlinear static analyses were performed considering both uniform (UNI) and modal (MOD) force distributions in both positive/negative horizontal directions (X, Y, and Y+). PO curves were produced in terms of Vh versus RDR. Bidirectional nonlinear MSA (Jalayer 2003; Scozzese et al. 2020) was performed by considering the conditional spectrum (CS) approach for the definition of the loading histories (Jayaram et al. 2011; Lin et al. 2013). In particular, the analysis records were derived by Iervolino et al. (2017, 2018). The spectral acceleration corresponding to the fundamental period of the buildings Sa(T1) was assumed as IM. Ten IM levels (or stripes) were defined by assuming the return period TR equal to 10, 50, 100, 250, 500, 1000, 2500, 10,000, and 100,000 years. For each IM level, 20 pairs of records (i.e., both horizontal components) were selected from the Italian accelerometric archive ITACA (http://itaca.mi.ingv.it) and the NGAwest2 database (http://peer.berkeley.edu/ngawest2/), and they were processed in order to achieve the compatibility with the conditional spectral accelerations. The fundamental periods T1 used for the spectral processing were assumed equal to 1.00, 0.50, and 0.15 s for BF, PF, and IF respectively, according to the modal response of the building typologies (RINTC Workgroup 2018; Suzuki and Iervolino 2019). As a representative depiction, the acceleration spectra Sa(T) related to AQ site (soil type C) are reported in Fig. 5, considering (a) the maximum component spectra and median/percentiles related to IM level 7 and (b) the median spectra related to all IM levels. The spectral acceleration related to the fundamental building period Sa(T1) is plotted versus TR (and related IM levels) in Fig. 6 for all sites and building typologies.

Fig. 5
figure 5

Acceleration spectra Sa(T) related to AQ site, considering a maximum component spectra (max comp), median, and 16th/84th percentiles related to IM level 7, and b median spectra related to all IM levels

Fig. 6
figure 6

Spectral acceleration corresponding to the fundamental vibration period Sa(T1) versus return period TR and corresponding IM level, related to a AQ, b NA, and c MI sites

5 Collapse characterization

5.1 Methodology

The collapse capacity and seismic demand related to the investigated buildings were assessed to characterize the different capacity criteria as a function of the building behavior and collapse features. The characterization of the collapse capacity criteria was expressed in terms of EDP capacities, demand to capacity ratios, fragility curves (building capacity estimation), estimated and target collapse margin ratios and probabilities (building collapse performance), and inter-capacity margin ratios.

The EDP collapse capacities were evaluated in the study, and they presented in Sect. 5.2; these were computed as described in Sect. 2. The chord rotation and inter-story drift ratio capacities (θu and IDRu, respectivelty) were estimated considering formulations and criteria derived from regulations and literature (Table 1), whereas the roof drift ratio capacities (RDRu) were estimated by processing the PO curves related to the performed numerical analyses (Sect. 4), according to literature studies.

The demand to capacity ratio (D/C) can be considered as a damage ratio of the structural members (e.g., Panagiotakos and Fardis 2004). D/C was evaluated as a function of (a) capacity criterion and (b) IM level. The D/C ratios were evaluated in the study and reported in Sect. 5.3. Considering the ith capacity criterion and the jth IM level, the kth data point represents the maximum ratio between the (maximum) seismic demand and the ith capacity criterion, where the seismic demand is related to the jth IM level and kth loading history, and both demand and capacity are expressed in terms of the ith capacity criterion EDP. The (maximum) D/C ratios related to the ultimate chord rotation θu (inter-story drift ratio IDRu) were defined as the maximum values among the ratios evaluated for frame and stairwell elements (all stories) related to both directions. The maximum D/C ratios related to the ultimate roof drift ratio (RDRu) were defined as the maximum values among the ratios related to both directions.

The fragility was defined as the probability that EDP exceeds or equals the EDP (capacity) threshold edp, given IM equal to Sa(T1), i.e., P[EDP ≥ edp | Sa(T1)]. The fragility was computed according to type-B or bounding method, defined by Porter et al. (2006, 2007), and a lognormal best-fitting model was assumed to fit the record-to-record data variability. The other sources of uncertainty (e.g., design requirements and modeling uncertainties) were not explicitly taken into account for the computation of the fragility curves since (a) the focus of the fragility assessment was on the record-to-record variability and (b) the other sources were not accurately estimated in the present study. The fragility median and (record to record) logarithmic standard deviation parameters are defined as m and β. Porter method was widely used in the literature (e.g., Di Sarno et al. 2019; Cremen and Baker 2019); therefore, the formulation is omitted for the sake of brevity. The fragility assessment was performed in the study and is reported in Sect. 5.4, considering the results related to AQ site buildings since the NA and MI buildings did not present an adequate minimum number of collapses corresponding to the highest IM level for all capacity criteria (e.g., Baker 2015; Suzuki and Iervolino 2019).

The collapse margin ratio represents a measure of the safety level of the building concerning the collapse and the collapse safety reserve (Haselton et al. 2011; Rofooei and Seyedkazemi 2020). The collapse margin ratio can be defined as the ratio between the median collapse capacity and the spectral demand of the maximum considered earthquake (MCE) ground motion (Federal Emergency Management Agency (FEMA) 2009; NEHRP Consultants Joint Venture 2010; American Society of Civil Engineers 2017b). The collapse performance was evaluated in this study, and the results are reported in Sect. 5.5. In particular, the estimated collapse margin ratios were computed and compared to the related acceptable or target values. The collapse margin ratios \({Z}_{2/50}\) and \({Z}_{5/50}\) were computed as shown in Eqs. (24) and (25), i.e., by considering the previously defined Sa(T1)2/50 and Sa(T1)5/50 as a spectral demand related to the MCE ground motion, respectively. It is worth mentioning that the reference collapse margin ratio assessment and the related performance evaluation were developed considering risk-targeted ground motion maps in the US and referring to the (risk-targeted) MCE ground motions (Federal Emergency Management Agency (FEMA) 2009; American Society of Civil Engineers 2017b). Some insightful technical comments regarding (risk-targeted) MCE ground motions and collapse assessment can be found in the seminal studies by Haselton et al. (2017) and Fajfar (2018). It is recalled that (a) Sa(T1)2/50 and Sa(T1)5/50 represent the Sa(T1) values conditional to 2% and 5% probability of exceedance in 50 years for the considered site and soil condition (corresponding to return period TR equal to 2475 and 975 years, respectively) and (b) m is the median value of the collapse fragility (expressed as Sa(T1)), considering a given collapse criterion. The conditional collapse probability (Sect. 5.5) can be defined as the fragility curve ordinate associated with the spectral demand related to the MCE ground motion, which in this case corresponds to Sa(T1)2/50 and Sa(T1)5/50.

$${\text{Z}}_{2/50} = \frac{{\text{m}}}{{{\text{Sa}}\left( {{\text{T}}_{1} } \right)_{2/50} }}$$
(24)
$${\text{Z}}_{5/50} = \frac{{\text{m}}}{{{\text{Sa}}\left( {{\text{T}}_{1} } \right)_{5/50} }}$$
(25)

A value equal to 10% was assumed as a target collapse probability (\({\bar{P} }_{c}\)), according to (Federal Emergency Management Agency (FEMA) 2009; American Society of Civil Engineers 2017b). The acceptable collapse margin ratio (\(\bar{Z }\)) was defined as it was recommended in (Federal Emergency Management Agency (FEMA) 2009; Zhang and He 2020), i.e., according to Eq. (26), where βTOT is the total uncertainty (i.e., logarithmic standard deviation including all main uncertainty sources), and ΦSTD represents the cumulative distribution function (CDF) of the standard normal distribution.

$${\bar{\text{Z}}} = {\text{exp}}\left( { - {\upbeta }_{{{\text{TOT}}}} {{ \Phi }}_{{{\text{STD}}}}^{ - 1} \left( {{\bar{\text{P}}}_{{\text{c}}} } \right)} \right)$$
(26)

The collapse margin ratios (e.g., \({Z}_{2/50}\) and \({Z}_{5/50}\)) are not directly affected by the dispersion of the fragility curves, but the dispersion affects the value of the acceptable collapse margin \(\bar{Z }\) (Eq. 26). In particular, \(\bar{Z }\) increases exponentially with βTOT (e.g., Eq. 26 (Zhang and He 2020)). The conditional collapse probability is directly conditioned by the fragility dispersion and tends to increase as the standard deviation increases (e.g., (Federal Emergency Management Agency (FEMA) 2009)). Some further insights and recent development regarding target collapse margin ratios and collapse probabilities can be found in (Douglas and Gkimprixis 2018; Zhang and He 2020).

For the abovementioned reasons, \(\bar{Z }\) was evaluated considering both record-to-record uncertainty (β) and total uncertainty (βTOT). This latter was defined according to (Federal Emergency Management Agency (FEMA) 2009) and is reported in Eq. (27), where design requirements uncertainty (βDR), test data uncertainty (βTD), and modeling uncertainty (βMDL) were assumed to be equal to 0.30, i.e., an average value evaluated over the recommended range of values, which is also compliant with typical values suggested in other literature studies (e.g., Porter et al. 2006).

$$\beta_{{{\text{TOT}}}} = \sqrt {\beta^{2} + \beta_{{{\text{DR}}}}^{2} + \beta_{{{\text{TD}}}}^{2} + \beta_{{{\text{MDL}}}}^{2} }$$
(27)

The inter-capacity margin ratio \({\rm{Z}}_{X}^{Y}\) is defined in Eq. (28), where X and Y are the two capacity criteria between which the margin has to be assessed and mX and mY are the related median values. The inter-capacity margin ratios were computed in the study, and the most relevant results are reported in Sect. 5.6.

$${\text{Z}}_{{\text{X}}}^{{\text{Y}}} = \frac{{{\text{m}}_{{\text{Y}}} }}{{{\text{m}}_{{\text{X}}} }}$$
(28)

Assessing the inter-capacity margin ratios identified between different criteria allows (a) checking the effects of the design process and prescriptions and (b) assessing the local to global collapse response and the yielding to heavily plastic behavior of the building. These margin ratios correlate in a quantitative manner the different criteria and relate their characteristics to the resulting building capacity. As an example, regular code-conforming buildings are expected to exhibit a relatively simultaneous degradation process of the ductile element sections, having the distribution of the plastic behavior as spread as possible over the candidate elements and regions. Then, while the margin, in terms of displacements, between the development of a global plastic behavior and the earliest element section collapse should be significant, the capacity margin between the earliest (ductile) element section collapse and the global collapse should be as reduced as possible, showing consistency between the global response and the behavior of the single members. Such (inter-capacity) margin can be considered as an irregularity feature of the building behavior.

5.2 EDP capacities

The empirical chord rotation formulations (θu1 and θu3) produce quite similar capacities for all elements, and the new Eurocode draft capacity (θu3) is typically slightly smaller than the current one. The physical formulation (θu2) often determines capacities larger than the empirical ones (θu1 and θu3); this is more significant for element sections that present a significant ultimate curvature. A similar trend was already found by Fusco et al. (2018), who compared the current Eurocode empirical and the physical (or mechanical-empirical) formulations to the experimental results related to literature tests on rectangular columns (it is worth specifying that the experimental database considered in (Fusco et al. 2018) was related to a wide range of geometrical and mechanical properties, which are in average not very similar to the ones related to the present study). The variation of the ultimate curvature directly affects the physical rotational capacity (Eq. 2.1), while this influence is less direct for the empirical ones. The difference between the HD capacity (θu4) and the empirical ones was quite irregular, and the former (latter) was often larger than the latter (former) for columns (beams). The considered IDRu capacities were already defined in Table 1. The roof drift (RD) values associated with the RDRu capacities (RDu1 and RDu2) are reported in Table 4 for both X and Y directions. The assumed RDRu capacities (i.e., minimum values over the different cases) are reported in Fig. 7 as RD values for (a) X and (b) Y directions. The PO curves are available in (RINTC Workgroup 2018; Ricci et al. 2018).

Table 4 Collapse capacities RDu1 and RDu2 related to RDRu1 and RDRu2 for both X and Y directions
Fig. 7
figure 7

Minimum collapse capacities related to RDRu1 and RDRu2 plotted as RD values for a X and b Y directions

5.3 Demand to capacity ratios

Figures 8, 9, and 10 depict the demand (D) to capacity (C) ratios (D/C) considering all capacity criteria and all building typologies for AQ, NA, and MI, respectively. The different building typology clearly affects the trend of D/C over the investigated collapse criteria. For instance, RDRu capacities (overall) resulted in the least conservative ratios for (all sites) BF and PF, whereas for IF (all sites) they produced ratios more similar to the other types of capacity. The discrepancy between RDRu1 and RDRu2 was quite reduced (significant) for BF and PF (IF). IDRu1 was particularly severe compared to the other IDRu capacities, which produced quite similar D/C ratios; this was more significant for IF and PF as the IDRu1 threshold was reduced for infilled inter-stories. IDRu5 was associated with the lowest D/C ratios, which were followed by RDRu2 one in terms of magnitude. It is recalled that IDRu5 could be representative of a condition relatively close or coinciding with sidesway collapse, as it was discussed in Sect. 2.1.

Fig. 8
figure 8

Maximum demand to capacity ratios D/C considering all collapse capacity criteria related to AQ site for a BF, b IF, and c PF buildings. The ratios related to θu and IDRu were defined as the maximum values among the ratios evaluated for frame and stairwell elements and among all stories, respectively, related to both directions. The ratios related to RDRu were defined as the maximum values among the ratios related to both directions. The numbers reported over each sub-plot indicate the number of occurred failures associated with the specific capacity criterion

Fig. 9
figure 9

Maximum demand to capacity ratios D/C considering all collapse capacity criteria related to NA site for a BF, b IF, and c PF buildings. The ratios related to θu and IDRu were defined as the maximum values among the ratios evaluated for frame and stairwell elements and among all stories, respectively, related to both directions. The ratios related to RDRu were defined as the maximum values among the ratios related to both directions. The numbers reported over each sub-plot indicate the number of occurred failures associated with the specific capacity criterion

Fig. 10
figure 10

Maximum demand to capacity ratios D/C considering all collapse capacity criteria related to MI site for a BF, b IF, and c PF buildings. The ratios related to θu and IDRu were defined as the maximum values among the ratios evaluated for frame and stairwell elements and among all stories, respectively, related to both directions. The ratios related to RDRu were defined as the maximum values among the ratios related to both directions. The numbers reported over each sub-plot indicate the number of occurred failures associated with the specific capacity criterion

The similarity between θu1 and θu3 produced very similar D/C results, and θu1 was the least conservative capacity; θu2 produced D/C ratios intermediate between the empirical and the HD capacity ones. No collapse occurred corresponding to the SLV state (i.e., IM level 5) for (all sites) BF, with (all capacity) D/C ratios ranging in 0.1 to 0.6 for AQ. IF and PF buildings were more critical (considering IDRu1) since one collapse occurred at SLV for AQ IF, almost one (maximum D/C equal to about 0.95) for AQ PF, and almost one for NA IF (maximum D/C equal to about 0.98). It is worth noting that the collapses related to IM level 8 BF MI (one case out of 20 for all capacities) were related to dynamic instability, and they were probably caused by numerical issues; however, they were not neglected for the sake of completeness.

The collapse occurrences NC0, NC1, and NCT related to the chord rotation capacities θu are reported in Table 5 for each element type of all AQ site buildings and corresponding to IM levels 9 and 10; four element types are taken into account, i.e., frame column, frame beam, stairwell short column, and stairwell short beam. In particular, for a given IM level, NC0 is the number of occurrences out of 20 pairs of records in which at least a member section of the specific element type reached collapse, whereas NC1 is the number of occurrences in which at least a member section of the specific element type reached collapse while no member section of any other element type collapsed. NCT is the total number of collapse occurrences out of 20 pairs of records considering all element types together. Obviously, the difference between NC1 and NC0 represents the occurrences in which the collapse of at least an element section of the specific element type occurs together with the collapse of at least an element section of any other element type (e.g., one beam section and one column section collapsed). The frame elements typically exhibit less collapses if compared to the stairwell elements, as it can be seen by comparing the related NC0 values. NC1 is equal zero for columns in all cases, whereas it equals one for beams in very few cases (reported in bold). The stairwell elements are quite more critical than the frame members (NC0), and they collapse earlier than these latter in some cases (e.g., NC1 is nonzero in some cases). No significant differences were identified comparing stairwell short columns and beams in terms of collapse occurrences (NC0 and NC1). In most cases, when an element type section collapsed, at least a section of any other element types reached collapse as well, showing that the collapse involves more element types. Some insights into the correlation between the collapse capacity criteria and the inelastic behavior of the buildings are also reported in the following sections.

Table 5 Collapse occurrences NC0, NC1, and NCT related to chord rotation capacities θu for each element type of all AQ site buildings and corresponding to IM levels 9 and 10

5.4 Fragility curves

Figure 11 shows the fragility curves related to (a) BF, (b) IF, and (c) PF buildings; Table 6 reports the related values of the median (m) and logarithmic standard deviation (β) for comparison purposes. The Sa(T1) values conditional to 2% and 5% probability of exceedance in 50 years for the considered site and soil condition, i.e., Sa(T1)2/50 and Sa(T1)5/50, are also reported; they are related to return period TR equal to 2475 and 975 years, respectively. The 2% limit (near collapse limit state NCLS) was recommended by Eurocode (CEN 2005), US codes (e.g., Luco et al. 2007), and this is widely used in the literature (Goulet et al. 2007; Haselton et al. 2011), whereas the 5% (collapse prevention limit state, SLC in Italian) one was reported by the Italian NTC 2008 (CS.LL.PP. 2008). In particular, the hazard parameters were derived from the database provided by Meletti and Montaldo (2007), and the spectral accelerations were compliant with the Italian NTC 2008 design spectra (CS.LL.PP. 2008). The fragility curves related to the yielding limit of the buildings are also reported in Fig. 11. This condition was defined by considering the earliest achievement of the yielding chord rotation θy (defined in Eq. 4.2) by at least one member section end.

Fig. 11
figure 11

Fragility curves evaluated considering the spectral acceleration ordinate corresponding to the building fundamental period (Sa(T1)) related to AQ site a BF, b IF, and c PF buildings

Table 6 Fragility median (m) and (record-to-record) logarithmic standard deviation (β) related to AQ site buildings for all considered capacity criteria

As a first comment, the yielding limit of the building was found to be consistent with the collapse seismic demand in terms of Sa(T1)2/50 and Sa(T1)5/50. As a matter of fact, for all building typologies (and AQ site) the collapse demand was associated with a high and very high probability of yielding initiation (e.g., larger than 75 and 95%). This confirms the consistency of the code-conforming building design since the building exhibit an inelastic behavior under normative collapse demands.

PF is more critical than BF and IF for all capacity criteria, whereas the relative discrepancies depend on the considered capacity criterion for the other building typologies. In fact, the different capacities produced quite spread fragilities for the different building typologies. This was particularly evident for IF buildings, for which the median fragility Sa(T1) ranged between 1.2 and 6.0 g. IDRu1 and IDRu5 produced the highest and lowest fragility for all building typologies, respectively, where higher fragility is meant as larger exceedance probability values for given IM thresholds, or equivalently, lower IM values for given exceedance probability thresholds. It is recalled that IDRu5 is expected to be more representative of sidesway-like conditions, and this is also consistent with the estimated fragilities. It is worth noting that RDRu2 follows IDRu5 in terms of higher fragility, and this also agrees with the nature of the former criterion (50% shear strength drop in PO curve from the peak value). The discrepancy between RDRu2 and IDRu5 fragility curves is relatively reduced for PF and relatively significant for BF, whereas it has an intermediate value for IF.

For IF and PF, a large fragility discrepancy between IDRu1 and the other IDRu capacities was observed, whereas this was minor for BF. It is recalled that IDRu1 is quite reduced for infilled inter-stories if compared to the other IDRu thresholds, whereas it is more comparable to these latter for bare stories. IDRu1 is certainly very conservative (especially for IF and PF), and it relates to an early plastic global response of the building, especially for IF and PF buildings, as it can be seen by comparing the yielding limit fragility and the IDRu1 collapse fragility curves. On the other side, RDRu2 and IDRu5 correspond to a more significant plastic (degradation) response, and it likely supplies quite reduced safety margins with regard to global collapse. θu4 produced fragilities lower than the other θu ones for all building typologies, whereas these latter were more comparable among them, with θu2 fragility slightly lower than the empirical ones. Indeed, the general conservativeness of the empirical formulations is highlighted. The IDRu2 to IDRu4 fragility range matches quite well the θu ones for BF, while it is relatively centered on the θu4 curve for both IF and PF. In particular, θu4 is associated with fragility very similar to the IDRu4 one for all building typologies (especially for BF and PF), which is still relatively distanced from RDRu2 and IDRu5 curves. This evidence suggests that, regardless of the different building typologies (i.e., BF, IF, and PF), IDRu4 is consistent with a relevant incursion into the inelastic response (e.g., onset of local collapse processes) even though still far from heavy softening (RDRu2) and sidesway-like collapse (IDRu5). More quantitative details on this aspect will be discussed in the following sections.

5.5 Collapse performance

Figure 12 shows the estimated collapse margin ratios Z2/50 and Z5/50 and the conditional collapse probabilities (considering record-to-record uncertainty β) larger than 0.09% for all capacity criteria related to AQ (a) BF, (b) IF, and (c) PF. Overall, the margin ratios are relatively large (low) for BF (PF). IF ratios are intermediate between BF and PF, except for RDRu1 and IDRu1, which are as critical as the PF ones. Figure 12 stresses the severity of IDRu1 (RDRu1) for both IF and PF (IF): very critical collapse margin ratios and probabilities were found. The relatively critical condition related to RDRu1 was mainly due to the low RDRu1 capacity, which was associated with large elastic stiffness and the heavy softening over the early post-yield branch (e.g., Ricci et al. 2018). Considering all criteria but IDRu1, the collapse capacity margin ratios (collapse probabilities) are larger (smaller) than the ones found by Haselton et al. (2011) and Noh and Tesfamariam (2018). The collapse margin ratio associated with IDRu5, which is likely to be the most adherent to sidesway-like collapse, is extremely high for BF (e.g., larger than 12), high for IF (e.g., larger than 7) and relatively reduced for PF (e.g., larger than 3). For PF, IF, and BF, the collapse margin ratio related to IDRu5 is quite similar, mildly larger, and significantly larger than the one associated with RDRu2, respectively. This highlights that the safety associated with heavy plastic incursion and global softening response (e.g., RDRu2) significantly depends on the building typology, and this is similar to, mildly larger, and significantly larger than the one associated with a sidesway-like collapse (IDRu5) for PF, IF, and BF buildings.

Fig. 12
figure 12

Collapse margin ratios Z2/50 (small thick markers) and Z5/50 (large thin markers) for all considered capacity criteria related to AQ a BF, b IF, and c PF buildings. The conditional collapse probabilities larger than 0.09% are reported (in %) at the top of each figure for each criterion; the inferior number (in bold) is related to Sa(T1)2/50 and the superior one (in italic) to Sa(T1)5/50

Despite the extreme conservativeness of IDRu1, the collapse probability related to this criterion significantly exceeded \({\bar{P} }_{c}\) only for IF using Sa(T1)2/50 and for PF. In fact, the collapse probability just exceeded \({\bar{P} }_{c}\) for IF using Sa(T1)5/50 and was below 0.09% for BF. Considering all criteria but IDRu1, the collapse probabilities are significantly far below the target value (\({\bar{P} }_{c}\) equal to 10%), as it can be seen in Fig. 12. RDRu1, θu1, and θu3 related to IF and θu3 related to PF exhibit the largest collapse probabilities, which are still significantly lower than \(\bar{P }\).

Table 7 reports the results of the collapse margin assessment. In particular, the acceptable collapse margin ratios (\(\bar{Z }\)) and collapse margin to acceptable margin ratios (\({\rm{Z}}_{2/50}/\bar{\rm{Z} }\)) and \({\rm{Z}}_{5/50}/\bar{\rm{Z} }\)) are reported considering both record-to-record uncertainty β and total uncertainty βTOT. The results related to RDRu2 and IDRu5 are highlighted according to the nature of these capacity criteria: both \({Z}_{2/50}/\bar{Z }\) and \({Z}_{5/50}/\bar{Z }\) related to BF are extremely large (e.g., larger than 3.5–4), and this stresses the excessive conservativeness of the design prescription for this building typology. The ratios associated with PF are significantly lower than the BF ones, but still (slightly) larger than the unity. This might suggest that despite the critical performance of PF buildings, the safety conditions are still satisfactory, even though with relatively reduced margin ratios. The ratios related to IF buildings have an intermediate value between BF and PF (e.g., larger than 2.5–3). It is recalled that the reported results are related to AQ site buildings, which are associated with the highest hazard conditions (and with the strictest design prescriptions). The collapse margin to acceptable margin ratios related to the other criteria quantify the correlations between the building safety and the different nature of the criteria. These values are reported in the paper for comparison purposes, and further comments on these values are omitted for the sake of brevity. Since the present work is not focused on the influence of the building typology on the collapse but addresses the influence of the different capacity criteria, further details and comments on the former aspects are also omitted.

Table 7 Collapse performance assessment related to AQ BF, IF, and PF buildings: acceptable collapse margin ratio (\(\bar{\rm{Z} }\)) and collapse margin ratios (\({\rm{Z}}_{2/50}\) and \({\rm{Z}}_{5/50}\)) to \(\bar{\rm{Z} }\) ratios evaluated considering record-to-record uncertainty (β) and total uncertainty (βTOT)

5.6 Inter-capacity margin ratios

\({\rm{Z}}_{X}^{Y}\) was computed considering Y equal to IDRu5 (i.e., \({Z}_{X}^{IDRu5}\)) and X equal to all capacity criteria for AQ (a) BF, (b) IF, and (c) PF buildings (Fig. 13). \({Z}_{X}^{IDRu5}\)identifies the building capacity from the X criterion capacity to the most adherent to the sidesway collapse. Depending on the specific X criterion, \({Z}_{X}^{IDRu5}\) provides useful information on the building response associated with the peculiar criterion characteristics. For example, \({Z}_{\theta y}^{IDRu5}\) defines the margin capacity corresponding to the whole post-elastic building response: a larger (smaller) value can be representative of a system that develops a more (less) significant resistance from the first yielding to the global collapse. Analogously, \({Z}_{\theta u}^{IDRu5}\) identifies the margin capacity corresponding to the local to sidesway-like collapse development. \({Z}_{\theta y}^{IDRu5}\) supplies quantitative information on the ductility of the buildings, even though the related capacity margin is not expressed as a deformation capacity. Analogously, the other margin ratios (e.g., \({Z}_{\theta u}^{IDRu5})\) supply information on the post-elastic and softening properties and capacities of the buildings, also expressed as a function of the building typology. The relatively higher (lower) inelastic capacity of BF (PF) building is quantitatively confirmed by larger (lower) \({Z}_{X}^{IDRu5}\) ratios. BF \({Z}_{\theta y}^{IDRu5}\) is approximately the double and triple of IF \({Z}_{\theta y}^{IDRu5}\) and PF \({Z}_{\theta y}^{IDRu5}\), respectively, and this latter was equal to about 5.4. BF \({Z}_{RDRu1}^{IDRu5}\) is slightly larger than PF \({Z}_{RDRu1}^{IDRu5}\), whereas IF \({Z}_{RDRu1}^{IDRu5}\) is 2.5 and 1.9 times larger than PF \({Z}_{RDRu1}^{IDRu5}\) and BF \({Z}_{RDRu1}^{IDRu5}\), respectively. \({Z}_{RDRu2}^{IDRu5}\) is relatively similar among the different building typologies, and IF (BF) exhibit the lowest (highest) value, equal to 1.10 (1.43); PF exhibits an intermediate value (1.23). PF \({Z}_{IDRu1}^{IDRu5}\) is quite similar to BF one, whereas IF \({Z}_{IDRu1}^{IDRu5}\) is significantly larger than BF and PF \({Z}_{IDRu1}^{IDRu5}\); PF \({Z}_{IDRu2}^{IDRu5}\), \({Z}_{IDRu3}^{IDRu5}\), and \({Z}_{IDRu4}^{IDRu5}\) values are quite similar to IF ones, and smaller than BF ones. \({Z}_{\theta u}^{IDR5}\) ratios related to BF (PF) range within 2 and 3 (1 and 2), and this stresses the high (low) local to global collapse capacity related to BF (PF). IF \({Z}_{\theta u}^{IDR5}\) is intermediate between the other building typologies.

Fig. 13
figure 13

Inter-capacity margin ratios \({Z}_{X}^{Y}\) computed considering Y = IDRu5 (i.e., \({Z}_{X}^{IDR5}\)) related to AQ a BF, b IF, and c PF buildings

\({\rm{Z}}_{X}^{Y}\) was also evaluated considering the following inter-capacity margin ratios related to AQ site buildings (Fig. 14): θu1 to RDRu1, θu1 to RDRu2, RDRu1 to RDRu2, θu1 to IDRu4, θy to RDRu1, and θy to IDRu1. θu1 was chosen to represent the rotational collapse capacity since this formulation typically represents the most used criterion among the investigated ones. The margin between RDRu2 and θu1 is larger than the margin between RDRu1 and θu1, proving that RDRu1 is more consistent with the local criterion; for IF building, the margin to θu1 is lower than one, showing that unexpectedly RDRu1 condition precedes the local collapse, as already revealed by Fig. 11. The θu1 to IDRu4 margin ratio does not depend on the building type and has a value which is not extremely large (e.g., smaller than the θu1 to RDRu2 margin ratio). A significant margin ratio is found regarding yielding limit, if RDRu1 is considered, especially for BF building, whereas the yielding limit margin is smaller if IDRu1 is considered, especially for both IF and PF buildings.

Fig. 14
figure 14

Inter-capacity margin ratios \({{\varvec{Z}}}_{{\varvec{X}}}^{{\varvec{Y}}}\) related to AQ site buildings

6 Key findings and research implications

The key findings resulting from the collapse characterization are summarized and discussed in the following according to the most relevant aspects.

6.1 Yielding limit

The buildings exhibit (local) yielding limit (θy) in almost all cases (e.g., very high probability over different records) under the seismic demand related to the collapse condition. This confirms a consistency with one of the main objectives of the capacity design approach. IDRu1 was found to be compatible with the building yielding onset for both infilled typologies, with the IDRu1 exhibiting a slightly lower fragility than θy. This does not occur for bare frame buildings, where IDRu1 corresponds to a fragility significantly lower than θy. IDRu1 criterion is confirmed to be extremely conservative as a collapse criterion.

6.2 Chord rotation collapse

The frame elements typically exhibit less collapses if compared to the stairwell elements. For both frame and stairwell elements, even though the beam-to-column capacity design brings to the development of the plastic hinges of the beams before than the column ones, the collapse of the two types of elements is generally contemporaneous.

6.3 θ u capacity criteria

The new Eurocode draft capacity in terms of empirical ultimate rotation (θu3) produces capacities quite similar to the empirical formulation reported in the current Eurocode (θu1), with θu3 slightly smaller than θu1 in some cases. This results in very similar fragility curves and collapse margin ratios/probabilities, with θu3 resulting in slightly higher vulnerability. The physical formulation (θu2) and the Haselton and Deierlein (HD) capacity (θu4) often produce capacities larger than the empirical ones (θu1 and θu3). In particular, θu2 can be considerably larger than θu1 and θu3 for element sections that present a significant ultimate curvature. The fragility (collapse margin ratios) related to θu2 are moderately lower (moderately higher) than θu1 and θu3 ones, whereas the fragility (collapse margin ratios) related to θu4 are significantly lower (significantly higher) than θu1 and θu3 ones. The results confirm that the investigated empirical chord rotation formulations can be preferred to the alternative ones (e.g., physical-based) since they are moderately more conservative. As a matter of fact, the draft of the new Eurocode specifies that the physical formulation should be used in very peculiar cases, and that the empirical formulation should be used for ordinary cases (e.g., rectangular sections). In these regards, this might represent a downgrade of the physical formulation, which is considered to be alternative to the empirical one by the current version of the Eurocode.

The capacity margin ratios identified between the local collapse (e.g., considering the earliest θu1 achievement) and heavy plastic and significantly degraded response (e.g., RDRu1 and RDRu2, respectively) is not significantly large (e.g., not larger than two). The margin ratio does not significantly depend on the building type for RDRu2, whereas it is lower (higher) for IF (BF and PF) considering RDRu1. It is recalled that this margin could be considered to be an index of irregularity of the building inelastic response, and the implication is that this irregularity is not considerably high and that it does not significantly depend on the building typology.

6.4 IDRu5 capacity criterion

IDRu5 was confirmed to be consistent with heavy plastic incursions and significant degradation and compatible with critical deformations of the building, towards a sidesway-like collapse. As a matter of fact, this latter criterion determines the lowest fragility, which is significantly (slightly) lower than RDRu2 for BF (IF and PF) buildings. It is recalled that this latter criterion was associated with a drop of 50% of the shear strength related to the pushover curve (PO) (heavy softening). Further analyses could correlate IDRu5 to actual sidesway collapse in quantitative terms, in order to corroborate the related findings.

6.5 IDRu2 to IDRu4 capacity criteria

The IDRu2 to IDRu4 fragility curves are compatible with the θu ones, especially considering IDRu4 and θu4for BF/PF buildings. Moreover, IDRu4 is also relatively far from RDRu2 and IDRu5 curves. Therefore, IDRu4 can be considered to be consistent with a condition of incursion into the plastic response that is still early if compared to heavy inelastic global response and sidesway-like collapse. This characteristic is not affected by the different building typologies, and this condition expresses the robustness of the criterion. Therefore, IDRu4 criterion might be used for reliable expeditious assessment of collapse since the quick and less accurate criterion evaluation (fixed threshold) is balanced by a higher safety.

6.6 Inter-capacity margin ratios

The inelastic capacities of the investigated buildings can be expressed as a function of the estimated inter-capacity margin ratios. For example, the higher and lower inelastic performance of BF and PF buildings is overall expressed by larger and lower \({Z}_{X}^{IDRu5}\), respectively. Analogously, the other characteristic of the local to global response and yielding to heavily plastic behavior can be assessed by considering the provided inter-capacity ratios.

6.7 Design safety

Considering IDRu5 as a capacity criterion, the collapse margin ratios are significantly higher and slightly higher than the target values considering BF and PF buildings, respectively, and IF buildings have intermediate trend. Therefore, the design prescriptions produce excessively conservative and just safe responses regarding BF and PF buildings, respectively, with intermediate over-safety conditions regarding IF buildings. It is worth to recall that the identified trends are related to AQ site buildings, which are designed considering the highest seismic hazard in Italy.

7 Conclusions

The paper investigated several capacity criteria—some of them never investigated—for the assessment of the collapse of low-rise RC frame buildings. In particular, bare frame (BF), infilled frame (IF), and pilotis frame (PF) buildings were designed according to the Italian building code considering low-to-high seismicity sites in Italy. The collapse capacity was assessed by considering both local and global collapse criteria, which were derived from literature studies and codes. The seismic demand was assessed by nonlinear multiple-stripe analysis (MSA) by considering modeling of both frame elements and infills. The collapse characterization was conducted according to the performance-based earthquake engineering (PBEE) approach. Collapse demand to capacity ratios were computed, and fragility curves were evaluated. The collapse margin ratios/probabilities were estimated, and their comparison with target (or acceptable) values allowed assessing the collapse performance according to the different criteria. Finally, the margin identified among the investigated criteria results (inter-capacity margin ratios) were evaluated.

The paper supplied novel information and technical insights into the collapse of low-rise code-conforming buildings, focusing on the influence of the different capacity criteria on the building collapse features. In particular, quantitative information was supplied on the building yielding and inelastic capacities and on the collapse performance according to the different criteria. In the light of the results, the use of consistent capacity criteria was discussed and safety and economic considerations regarding the design process were outlined.

The study cannot be considered to be exhaustive despite the extensive and wide numerical analyses and the robust assessment methodologies. It should be stressed that the quantitative findings might reflect the fact the low-rise buildings were considered in the study. However, the methodology can be fully extended to different building types and soil conditions, and the trends of the findings could also be found with regard to different case studies and applications. Finally, further analyses should be performed by refining the numerical modeling (e.g., including beam-to-column joint response) and assessing the sidesway collapse considering a more direct approach.