A measurement concept has been realized for the detection of carbon dioxide, where the CO2 induced pressure generation by an enclosed pH-sensitive hydrogel is measured with a micro pressure sensor. The application of the sensor is the quantification of the partial pressure of CO2 (Pco2) in the stomach as diagnosis for gastrointestinal ischemia. The principle is put to the proof by examining the sensor response to changes in Pco2. Furthermore, the response time, temperature-sensitivity and resolution are determined. The sensor responds well to changes in Pco2 with a maximum pressure generation of 0.29× 105 Pa at 20 kPa CO2. The 90% response time varies between 1.5 and 4.5 minutes at 37∘C. The sensor shows a linear temperature-sensitivity which can easily be compensated for, and enables detection of Pco2 changes as small as 0.5 kPa CO2.
Similar content being viewed by others
References
C.R. Adams, K.M. Bamford, and M.P. Early, Principles of Horticulture, 3rd edition (Butterworth-Heinemann, Oxford, UK, 1984).
Ph. Arquint, A. van den Berg, and B.H. van der Schoot N.F. de Rooij, Sens. Actuators B 13–14, 340 (1993).
C. Baird, Environmental Chemistry, 1st edition (W.H. Freemand and Company, New York, USA, 1995).
F. Baldini, A. Falai, A.R. De Gaudio, D. Landi, A. Lueger, A. Mencaglia, D. Scherr, and W. Trettnak, Sens. Actuators B 90, 132 (2003).
H. Beyenal, C.C. Davis, and Z. Lewandowski, Sens. Actuators B 97, 202 (2004).
H. Brønsted and J. Kopeček, in Polyelectrolyte Gels, edited by R.S. Harland (American Chemical Society, Washington DC, 1992), Vol. 480, Chap. 17, p. 285.
Q. Cai, K. Zeng, C. Ruan, T.A. Desai, and C.A. Grimes, Anal. Chem. 76, 4038 (2004).
M.F. Choi and P. Hawkins, Anal. Chem. 67, 3897 (1995).
H.W. Davenport, The ABC of Acid-Base Chemistry, 6th edition (University of Chicago press, Chicago, USA, 1974).
R.E. Ellis and B.D. Schurin, Appl. Opt. 8, 2265 (1969).
C.A. Erdmann, K.C. Steiner, and M.G. Apte, Proc. Indoor Air Conference 3, 443 (2002).
R. Fasching, F. Keplinger, G. Hanreich, G. Jobst, G. Urban, F. Kohl, and R. Chabicovsky, Sens. Actuators B 78, 291 (2001).
P.E. Grimshaw, J.H. Nussbaum, and A.J. Grodzinsky, J. Chem. Phys. 93, 4462 (1990).
A.B. Groeneveld and J.J. Kolkman, J. Crit. Care 9, 198 (1994).
A. Haeusler and J. Meyer, Sens. Actuators B 34, 388 (1996).
J.Z. Hilt, A.K. Gupta, R. Bashir, and N.A. Peppas, Biomedical Microdevices 5, 177 (2003).
S. Herber, W. Olthuis, and P. Bergveld, Sens. Actuators B 91, 378 (2003).
S. Herber, W. Olthuis, P. Bergveld, and A. van den Berg, Sens Actuators 103, 284 (2004a).
S. Herber, W. Olthuis, P. Bergveld, and A. van den Berg, J. Chem. Phys. 121, 2746 (2004b).
N. Imanaka, M. Kamikawa, and G. Adachi, Anal. Chem. 74, 4800 (2002).
N. Imanaka, M. Kamikawa, S. Tamura, and G. Adachi, Sens. Actuators B 77, 301 (2001).
J.J. Kolkman, J.A. Otte, and A.B. Groeneveld, Br. J. Anaesth. 84, 101 (2000).
J.J. Kolkman, L.J. Zwaarekam, K. Boshuizen, A.B. Groeneveld, and S.G. Meuwissen, J. Clin. Monit 13, 115 (1997).
M.D. Marazuela, M.C. Moreno Bondi, and G. Orellana, Sens. Actuators B 29, 126 (1995).
Y. Miyachi, G. Sakai, K. Shimanoe, and N. Yamazoe, Sens. Actuators B 93, 250 (2003).
T. Miyata, N. Asami, and T. Uragami, Nature 399, 766 (1999).
T. Miyata, T. Uragami, and K. Nakamae, Adv. Drug Delivery Rev. 54, 79 (2002).
M.C. Moreno Bondi, E. Segovia, and M.D. Marazuela, Anal. Chem. 64, 2210 (1992).
W.N. Opdycke and M. Meyerhoff, Anal. Chem. 58, 950 (1986).
J.A. Otte, E. Oostveen, R.H. Geelkerken, A.B. Groeneveld, and J.J. Kolkman, J. Appl. Physiol. 91, 866 (2001).
C. Ruan, K.G. Ong, C. Mungle, M. Paulose, N.J. Nickl, and C.A. Grimes, Sens. Actuators B 96, 61 (2003).
B.D. Schurin and R.E. Ellis, Appl. Opt. 7, 467 (1968).
T. Sekiguchi, Y. Nagai, T. Makino, K. Ohno, M. Nakamura, H. Hosaka, H. Sakio, S. Ohtsu, and H. Takahashi, Sens. Actuators B 49, 171 (1998).
J.W. Severinghaus and A.F. Bradley, J. Appl. Physiol. 13, 515 (1958).
J.H. Shin, J.S. Lee, S.H. Choi, D.K. Lee, H. Nam, and G.S. Cha, Anal. Chem. 72, 4468 (2002).
E. Steudel, P. Birke, and W. Weppner, Electrochimica Acta 42, 3147 (1997).
Z.A. Strong, A.W. Wang, and C.F. McConaghy, Biomedical Microdevices 4, 97 (2002).
H. Suzuki and H. Arakawa, Anal. Chem. 71, 1737 (1999).
S. Tamura, N. Imanaka, M. Kamikawa, and G. Adachi, Sens. Actuators B 73, 205 (2001).
M.J. Tierney and H.L. Kim, Anal. Chem. 65, 3435 (1993).
K. Tsukada, Y. Miyahara, Y. Shibata, and H. Miyagi, Sens. Actuators B 2, 291 (1990).
H. van der Linden, S. Herber, W. Olthuis, and P. Bergveld, The Analyst 28, 325 (2003).
B.H. Weigi and O.S. Wolfbeis, Anal. Chem. 66, 3323 (1994).
Y. Zhang, H. Ji, G.M. Brown, and T. Thundat, Anal. Chem. 75, 4773 (2003).
P. Zhao and W. Cai, Anal. Chem. 69, 5052 (1997).
Z. Zhou, L. Feng, and Y. Zhou, Sens. Actuators B 76, 60 (2001).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Herber, S., Bomer, J., Olthuis, W. et al. A Miniaturized Carbon Dioxide Gas Sensor Based on Sensing of pH-Sensitive Hydrogel Swelling with a Pressure Sensor. Biomed Microdevices 7, 197–204 (2005). https://doi.org/10.1007/s10544-005-3026-5
Issue Date:
DOI: https://doi.org/10.1007/s10544-005-3026-5