Abstract
This report presents results from research towards a fully integrated, wireless neural interface consisting of a 100-channel microelectrode array, a custom-designed signal processing and telemetry IC, an inductive power receiving coil, and SMD capacitors. An integration concept for such a device was developed, and the materials and methods used to implement this concept were investigated. We developed a multi-level hybrid assembly process that used the Utah Electrode Array (UEA) as a circuit board. The signal processing IC was flip-chip bonded to the UEA using Au/Sn reflow soldering, and included amplifiers for up to 100 channels, signal processing units, an RF transmitter, and a power receiving and clock recovery module. An under bump metallization (UBM) using potentially biocompatible materials was developed and optimized, which consisted of a sputter deposited Ti/Pt/Au thin film stack with layer thicknesses of 50/150/150 nm, respectively. After flip-chip bonding, an underfiller was applied between the IC and the UEA to improve mechanical stability and prevent fluid ingress in in vivo conditions. A planar power receiving coil fabricated by patterning electroplated gold films on polyimide substrates was connected to the IC by using a custom metallized ceramic spacer and SnCu reflow soldering. The SnCu soldering was also used to assemble SMD capacitors on the UEA. The mechanical properties and stability of the optimized interconnections between the UEA and the IC and SMD components were measured. Measurements included the tape tests to evaluate UBM adhesion, shear testing between the Au/Sn solder bumps and the substrate, and accelerated lifetime testing of the long-term stability for the underfiller material coated with a a-SiCx:H by PECVD, which was intended as a device encapsulation layer. The materials and processes used to generate the integrated neural interface device were found to yield a robust and reliable integrated package.
Similar content being viewed by others
References
J. Aziz, R. Genov, M. Derchansky, B. Bardakjian, P. Carlen, 256-Channel Neural Recording Microsystem with On-Chip 3D Electrodes. In Proceedings of 2007 IEEE International Solid-State Circuits Conference, 160–161, 594, San Francisco, CA, USA (2007)
A. Branner, R.B. Stein, E. Fernandez, Y. Aoyagi, R.A. Normann, Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve IEEE Trans. Biomed. Eng. 51, 146–157 (2004). doi:10.1109/TBME.2003.820321
P.K. Campbell, K.E. Jones, R.J. Huber, K.W. Horch, R.A. Normann, A silicon-based, three-dimensional neural interface: manufacturing processes for an intra cortical electrode array IEEE Trans. Biomed. Eng 38, 758–768 (1991). doi:10.1109/10.83588
C.A. Chestek, V. Gilja, R.J. Kier, P. Nuyujukian, S.I. Ryu, F. Solzbacher, R. Harrison, K.V. Shenoy, C. Hermes, RF wireless low-power neural recording system for freely-behaving primates. In Proc. of the 2008 IEEE International Symposium on Circuits and Systems (ISCAS 2008), Seattle, Washington (2008)
G.A. DeMichele, P.R. Troyk, Integrated multichannel wireless biotelemetry system. In Proc. 25th Int. IEEE-EMBS Conf., 3372–3375, Cancun, Mexico (2003)
S. Farshchi, P. Nuyujukian, A. Pesterev, I. Mody, J.W. Judy, A. Tiny, OS enabled MICA2-based wireless neural interface IEEE Trans. Biomed. Eng. 53, 1416–1424 (2006). doi:10.1109/TBME.2006.873760
M.D. Gingerich, J.F. Hetke, D.J. Anderson, K.D. Wise, A 256-site 3-D CMOS microelectrode array for multipoint stimulation and recording in the central nervous system. In Proc. Int. Conf. Solid-State Sensors and Actuators, 416–419, Munich, Germany (2001)
R. Hahn, A. Kamp, A. Ginolas, M. Schmidt, J. Wolf, V. Glaw, M. Töpper, O. Ehrmann, H. Reichl, High power multichip modules employing the planar embedding technique and microchannel water heat sinks IEEE Trans. Compon. Pack. A 20, 432–441 (1997)
R.R. Harrison, P.T. Watkins, R.J. Kier, R.O. Lovejoy, D.J. Black, B. Greger, F. Solzbacher, A low-power integrated circuit for a wireless100-electrode neural recording system IEEE J. Solid-State Circuits 42, 123–133 (2007a). doi:10.1109/JSSC.2006.886567
R.R. Harrison, P.T. Watkins, R.J. Kier, D.J. Black, R.O. Lovejoy, R.A. Normann, F. Solzbacher, Design and testing of an integrated circuit for multi-electrode neural recording. In Proceedings of the 20th International Conference on VLSI Design (VLSID 2007), Bangalore, India (2007b)
R.R. Harrison, R.J. Kier, C.A. Chestek, V. Gilja, P. Nuyujukian, S.I. Ryu, B. Greger, F. Solzbacher, K.V. Shenoy, Wireless neural signal acquisition with single low-power integrated circuit. In Proc. of the 2008 IEEE International Symposium on Circuits and Systems (ISCAS 2008), Seattle, Washington (2008)
J.L. Hill, D.E. Culler, Mica: a wireless platform for deeply embedded networks IEEE Micro 22, 12–24 (2002). doi:10.1109/MM.2002.1134340
L.R. Hochberg, M.D. Serruya, G.M. Friehs, J.A. Mukand, M. Saleh, A.H. Caplan, A. Branner, D. Chen, R.D. Penn, J.P. Donoghue, Neuronal ensemble control of prosthetic devices by a human with tetraplegia Nature 442, 164–171 (2006). doi:10.1038/nature04970
A.C. Hoogerwerf, K.D. Wise, A three-dimensional microelectrode array for chronic neural recording IEEE Trans. Biomed. Eng. 41, 1136–1146 (1994). doi:10.1109/10.335862
J.-M. Hsu, L. Rieth, S. Kammer, K.P. Koch, R.A. Normann, F. Solzbacher, PECVD a-SiC:H and Parylene encapsulation for chronically implanted neural recording devices. NIH/NINDS Neural Interfaces Workshop, Bethesda, MD, USA (2005)
J.-M. Hsu, P. Tathireddy, L. Rieth, R.A. Normann, F. Solzbacher, Characterization of a-SiCx:H thin films as an encapsulation material for integrated silicon based neural interface devices Thin. Solid. Films 516, 34–41 (2007). doi:10.1016/j.tsf.2007.04.050
J.-M. Hsu, L. Rieth, R.A. Normann, P. Tathireddy, F. Solzbacher, Hermetic encapsulation of an integrated neural interface device with Parylene-C. IEEE Trans. Biomed. Eng. (2008a) accepted for publication
J.-M. Hsu, L. Rieth, S. Kammer, M. Orthner, F. Solzbacher, Influence of thermal and deposition processes on the surface morphology, crystallinity, and adhesion of Parylene-C Sens. Mater. 20, 071–086 (2008b)
M. Hutter, H. Hohnke, H. Oppermann, M. Klein, G. Engelmann, Assembly and Reliability of Flip Chip Solder Joints Using Miniaturized Au/Sn Bumps., In Proc. 54th Electronic Components and Technology Conf., Las Vegas, NV, USA (2004)
P. Irazoqui-Pastor, I. Mody, J.W. Judy, Transcutaneous RF-powered neural recording device. In Proc. 24th Annu. Conf./Annu. Fall Meeting Biomedical Engineering Society 3, 2105–2106, Houston, TX, USA (2002)
K.E. Jones, P.K. Campbell, R.A. Normann, A glass/silicon composite intra cortical electrode array Ann. Biomed. Eng. 20, 423–437 (1992). doi:10.1007/BF02368134
C. Kim, K.D. Wise, A 64-site multishank CMOS low-profile neural stimulating probe IEEE J. Solid-State Circuits 31, 1230–1238 (1996). doi:10.1109/4.535406
S. Kim, K. Zoschke, M. Klein, D. Black, K. Buschick, M. Toepper, P. Tathireddy, R. Harrison, H. Oppermann, F. Solzbacher, Switchable polymer based thin film coils as a power module for wireless neural interfaces Sensors Actuators A 136, 467–474 (2007). doi:10.1016/j.sna.2006.10.048
D.R. Kipke, R.J. Vetter, J.C. Williams, J.F. Hetke, Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex IEEE Trans. Neural Syst. Rehabil. Eng. 11, 151–155 (2003). doi:10.1109/TNSRE.2003.814443
S. Martel, N. Hatsapoulos, I. Hunter, J. Donoghue, J. Burger, J. Malasek, C. Wiseman, R. Dyer, Development of a Wireless Brain Implant: the Telemetric Electrode Array System (TEAS) Project. In Proceedings of the 23rd Annual EMBS International Conference, Istanbul, Turkey (2001)
M. Modarreszadeh, R.N. Schmidt, Wireless, 32-channel, EEG and epilepsy monitoring system. In Proc. 19th Int. Conf. IEEE/EMBS, 1157–1160, Chicago, IL, USA (1997)
P. Mohseni, K. Najafi, A wireless FM multichannel microsystem for biomedical neural recording applications. In Proc. IEEE Southwest Symp. Mixed Signal Design, 217–222, Tucson, AZ, USA (2003)
P. Mohseni, K. Najafi, Wireless multichannel biopotential recording using an integrated FM telemetry circuit. In Proc. 26th Annu. Int. Conf. Engineering in Medicine and Biology Soc., 4083–4086, San Francisco, CA, USA (2004)
A. Nieder, Miniature stereo radio transmitter for simultaneous recording of multiple single-neuron signals from behaving owls J. Neurosci. Methods 101, 157–164 (2000). doi:10.1016/S0165-0270(00)00263-6
I. Obeid, M.A.L. Nicolelis, P.D. Wolf, A multichannel telemetry system for single unit neural recordings J. Neurosci. Methods 133, 33–38 (2004). doi:10.1016/j.jneumeth.2003.09.023
J. Parramon, P. Doguet, D. Martin, M. Verleyssen, R. Munoz, L. Leija, E. Valderrama, ASIC-based batteryless implantable telemetry microsystem for recording purposes. In Proc. 19th Int. IEEE-EMBS Conf., 2225–2228, Chicago, IL, USA (1997)
W.R. Patterson, Y.-K. Song, C.W. Bull, I. Ozden, A.P. Deangellis, C. Lay, J.L. McKay, A.V. Nurmikko, J.D. Donoghue, B.W. Connors, A microelectrode/microelectronic hybrid device for brain implantable neuroprosthesis applications IEEE Trans. Biomed. Eng. 51, 1845–1853 (2004). doi:10.1109/TBME.2004.831521
P.J. Rousche, R.A. Normann, Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex J. Neurosci. Methods 82, 1–15 (1998). doi:10.1016/S0165-0270(98)00031-4
P.J. Rousche, R.A. Normann, Chronic intracortical microstimulation (ICMS) of cat sensory cortex using the utah intracortical electrode array IEEE Trans. Rehabil. Eng. 7, 56–68 (1999). doi:10.1109/86.750552
G. Santhanam, S.I. Ryu, B.M. Yu, A. Afshar, K.V. Shenoy, A high-performance brain-computer interface Nature 442, 195–198 (2006). doi:10.1038/nature04968
H.J. Song, D.R. Allee, K.T. Speed, Single chip system for bio-data acquisition, digitization and telemetry In Proc. 1997 IEEE Int. Symp. Circuits Systems 3, 1848–1851 (1997)Hong Kong
Y.-K. Song, W.R. Patterson, C.W. Bull, D.A. Borton, Y. Li, A.V. Nurmikko, J.D. Simeral, J.D. Donoghue, A brain implantable microsystem with hybrid RF/IR telemetry for advanced neuroengineering applications. In Proceedings of the 29th Annual International Conference of the IEEE EMBS, 445-448, Lyon, France (2007)
T. Stieglitz, H. Beutel, M. Schuettler, J.-U. Meyer, Micromachined, polyimide-based devices for flexible neural interfaces Biomed. Microdevices 2, 283–294 (2000). doi:10.1023/A:1009955222114
T. Stieglitz, M. Schuettler, K.P. Koch, Implantable biomedical microsystems for neural prostheses IEEE Eng. Med. Biol. Mag. 24, 58–65 (2005). doi:10.1109/MEMB.2005.1511501
S. Takeuchi, I. Shimoyama, A radio-telemetry system with a shape memory alloy microelectrode for neural recording of freely moving insects IEEE Trans. Biomed. Eng. 51, 133–137 (2004). doi:10.1109/TBME.2003.820310
M.E. Thomas, M.P. Hartnett, J.E. McKay, The use of surface profilometers for the measurement of wafer curvature J. Vac. Sci. Technol. A 6, 2570–2571 (1998). doi:10.1116/1.575550
M. Töpper, J. Wolf, V. Glaw, K. Buschick, A. Dabek, L. Dietrich, O. Ehrmann, H. Reichl, MCM-D with Embedded Active and Passive Components. In Proceedings ISHM 1996, Minneapolis, USA (1996)
M. Töpper, K. Buschick, J. Wolf, V. Glaw, R. Hahn, A. Dabek, O. Ehrmann, H. Reichl, Embedding Technology—A Chip-First Approach using BCB. In Proc. of the 3rd International Symposium on Advanced Packaging Materials, 11–14 (1997)
M. Töpper, D. Tönnies, Microelectronic Packaging, in Semiconductor Fabrication Handbook, ed. by M.H. Geng (McGraw-Hill, 2005), pp. 21.1–21.54
K.D. Wise, D.J. Anderson, J.F. Hetke, D.R. Kipke, K. Najafi, Wireless implantable microsystems: high-density electronic interfaces to the nervous system Proc. IEEE 92, 76–97 (2004). doi:10.1109/JPROC.2003.820544
Y. Yao, M.N. Gulari, J.F. Hetke, K.D. Wise, A self-testing multiplexed CMOS stimulating probe for a 1024-site neural prosthesis. In Proc. IEEE Int. Conf. Solid-State Sensors and Actuators, 1213–1216, Boston, MA, USA (2003)
Y. Yao, M.N. Gulari, J.A. Wiler, K.D. Wise, A microassembled low-profile three-dimensional microelectrode array for neural prosthesis applications J. Microelectromech. Syst. 16, 977–988 (2007). doi:10.1109/JMEMS.2007.896712
Acknowledgment
This work was supported in part by NIH/NINDS Contract HHSN265200423621C and by DARPA under Contract N66001-06-C-8005. The authors gratefully acknowledge the colleagues at Fraunhofer IZM for their technical assistance in setup and conducting IC bumping, flip chip bonding and SMD reflow soldering.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, S., Bhandari, R., Klein, M. et al. Integrated wireless neural interface based on the Utah electrode array. Biomed Microdevices 11, 453–466 (2009). https://doi.org/10.1007/s10544-008-9251-y
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10544-008-9251-y