Skip to main content
Erschienen in: Experimental Mechanics 4/2011

01.04.2011

Multi-scale Mechanical Characterization of Palmetto Wood using Digital Image Correlation to Develop a Template for Biologically-Inspired Polymer Composites

verfasst von: S. Haldar, N. Gheewala, K. J. Grande-Allen, M. A. Sutton, H. A. Bruck

Erschienen in: Experimental Mechanics | Ausgabe 4/2011

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Palmetto wood is garnering growing interest as a template for creating biologically-inspired polymer composites due to its historical use as an energy absorbing material in protective structures. In this study, quasi-static three-point bend tests have been performed to characterize the mechanical behavior of Palmetto wood. Full-field deformation measurements are obtained using Digital Image Correlation (DIC) to elucidate on the strain fields associated with the mechanical response. By analyzing strain fields at multiple length scales, it is possible to study the more homogeneous mechanical behavior at the macro-scale associated with the global load-deformation response; while at the microscale the mechanical behavior is more inhomogeneous due to microstructural failure mechanisms. Thus, it was possible to determine that, despite the presence of discontinuous macro-fiber reinforcement, at the macro-scale the response is associated with classical bending and progressive failure processes that are adequately described by Weibull statistics proceeding from the tensile side of the specimen. At the microscale, however, the failure mechanisms giving rise to the macroscopic response consist of both shear-dominated debonding between the fiber and matrix, and inter-fiber matrix failure due to pore collapse. These microscale mechanisms are present in both the compressive and tensile regions of the specimen, most likely due to local macro-fiber bending, which is independent of the global bending state. The pore collapse mechanism observed during mechanical loading appears to improve the energy absorption of the matrix material, thereby, transferring less energy and shear strain to the macro-fiber-matrix interface for initiation of debonding. However, the pore collapse mechanism can also accumulate substantial shear strain, which results in matrix shear cracking. Through these complex failure mechanisms, Palmetto wood exhibits a high resistance to catastrophic failure after damage initiation, an observation that can be used as inspiration for creating new polymer composite materials.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Bruck HA, Evans JJ, Peterson ML (2002) The role of mechanics in biological and biologically inspired materials. Exp Mech 42(4):361–371CrossRef Bruck HA, Evans JJ, Peterson ML (2002) The role of mechanics in biological and biologically inspired materials. Exp Mech 42(4):361–371CrossRef
2.
Zurück zum Zitat Forsberg F, Sjodahl M, Mooser R, Hack E, Wyss P (2010) Full three-dimensional strain measurements on wood exposed to three-point bending: analysis by use of digital volume correlation applied to synchrotron radiation micro-computed tomography image data. Strain 46(1):47–60CrossRef Forsberg F, Sjodahl M, Mooser R, Hack E, Wyss P (2010) Full three-dimensional strain measurements on wood exposed to three-point bending: analysis by use of digital volume correlation applied to synchrotron radiation micro-computed tomography image data. Strain 46(1):47–60CrossRef
3.
Zurück zum Zitat Gershon AL, Bruck HA, Xu S, Sutton MA, Tiwari V (2010) Multiscale mechanical and structural characterizations of Palmetto wood for bio-inspired hierarchically structured polymer composites. Mater Sci Eng C 30:235–244CrossRef Gershon AL, Bruck HA, Xu S, Sutton MA, Tiwari V (2010) Multiscale mechanical and structural characterizations of Palmetto wood for bio-inspired hierarchically structured polymer composites. Mater Sci Eng C 30:235–244CrossRef
4.
Zurück zum Zitat Wei A, Carlsson TE (2003) Speckle interferometry for measurement of continuous deformations. Opt Lasers Eng 40:529–541CrossRef Wei A, Carlsson TE (2003) Speckle interferometry for measurement of continuous deformations. Opt Lasers Eng 40:529–541CrossRef
5.
Zurück zum Zitat Li X, Wei C, Yang Y (2005) Full field and microregion deformation measurement of thin films using electronic speckle pattern interferometry and array microindentation marker method. Opt Lasers Eng 43:869–884CrossRef Li X, Wei C, Yang Y (2005) Full field and microregion deformation measurement of thin films using electronic speckle pattern interferometry and array microindentation marker method. Opt Lasers Eng 43:869–884CrossRef
6.
Zurück zum Zitat Sutton MA, Mingqi C, Peters WH, Chao YJ, McNeill SR (1986) Application of an optimized digital correlation method to planar deformation analysis. Image Vis Comput 4:143–150CrossRef Sutton MA, Mingqi C, Peters WH, Chao YJ, McNeill SR (1986) Application of an optimized digital correlation method to planar deformation analysis. Image Vis Comput 4:143–150CrossRef
7.
Zurück zum Zitat Czarnek R, Lee J, Rantis T (1990) Moiré interferometry with enhanced resolution. Exp Tech 2:24–8CrossRef Czarnek R, Lee J, Rantis T (1990) Moiré interferometry with enhanced resolution. Exp Tech 2:24–8CrossRef
8.
Zurück zum Zitat Miller M, Mohammed L, Ho P (2001) Quantitative strain analysis of flip-chip electronic packages using phase-shifting moiré interferometry. Opt Lasers Eng 36:127–39CrossRef Miller M, Mohammed L, Ho P (2001) Quantitative strain analysis of flip-chip electronic packages using phase-shifting moiré interferometry. Opt Lasers Eng 36:127–39CrossRef
9.
Zurück zum Zitat Morimoto Y, Hayashi T (1984) Deformation measurement during powder compaction by a scanning moiré method. Exp Mech 24:112–116CrossRef Morimoto Y, Hayashi T (1984) Deformation measurement during powder compaction by a scanning moiré method. Exp Mech 24:112–116CrossRef
10.
Zurück zum Zitat Chen H, Liu D, Lee A (2000) Moiré in atomic force microscope. Exp Tech 24(1):31–32CrossRef Chen H, Liu D, Lee A (2000) Moiré in atomic force microscope. Exp Tech 24(1):31–32CrossRef
11.
Zurück zum Zitat Chien CH, Wu YD, Chiou YT, Hsieh CC, Chen YC, Chen TP, Tsai ML, Wang CT (2006) Nanoscale deformation measurement by using the hybrid method of gray-level and holographic interferometry. Opt Lasers Eng 44:80–91CrossRef Chien CH, Wu YD, Chiou YT, Hsieh CC, Chen YC, Chen TP, Tsai ML, Wang CT (2006) Nanoscale deformation measurement by using the hybrid method of gray-level and holographic interferometry. Opt Lasers Eng 44:80–91CrossRef
12.
Zurück zum Zitat Chang M, Hu CP, Lam P, Wyant JC (1985) High precision deformation measurement by digital phase shifting holographic interferometry. Appl Opt 24(22):3780–3783CrossRef Chang M, Hu CP, Lam P, Wyant JC (1985) High precision deformation measurement by digital phase shifting holographic interferometry. Appl Opt 24(22):3780–3783CrossRef
13.
Zurück zum Zitat Creath K (1985) Phase-shifting speckle interferometry. Appl Opt 24(18):3053–3058CrossRef Creath K (1985) Phase-shifting speckle interferometry. Appl Opt 24(18):3053–3058CrossRef
14.
Zurück zum Zitat Pedrini G, Tiziani HJ (1994) Double-pulse electronic speckle interferometry for vibration analysis. Appl Opt 33(34):7857–63CrossRef Pedrini G, Tiziani HJ (1994) Double-pulse electronic speckle interferometry for vibration analysis. Appl Opt 33(34):7857–63CrossRef
15.
Zurück zum Zitat Moore AJ, Hand DP, Barton JS, Jones JDC (1999) Transient deformation measurement with electronic speckle pattern interferometry and a high-speed camera. Optical Society of America 38:1159–1162 Moore AJ, Hand DP, Barton JS, Jones JDC (1999) Transient deformation measurement with electronic speckle pattern interferometry and a high-speed camera. Optical Society of America 38:1159–1162
16.
Zurück zum Zitat Anderson DJ, Valera JD, Jones JDC (1993) Electronic speckle pattern interferometry using diode laser spectroscopic illumination. Meas Sci Technol 4:982–987CrossRef Anderson DJ, Valera JD, Jones JDC (1993) Electronic speckle pattern interferometry using diode laser spectroscopic illumination. Meas Sci Technol 4:982–987CrossRef
17.
Zurück zum Zitat Cookson TJ, Butters JN, Pollard HC (1978) Pulsed lasers in electronic speckle pattern interferometry. Opt Laser Technol 10:119–124CrossRef Cookson TJ, Butters JN, Pollard HC (1978) Pulsed lasers in electronic speckle pattern interferometry. Opt Laser Technol 10:119–124CrossRef
18.
Zurück zum Zitat Moore AJ, Pérez-López C (1996) Fringe-visibility enhancement and phase calculation in double-pulsed addition ESPI. J Mod Opt 43:1829–1844CrossRef Moore AJ, Pérez-López C (1996) Fringe-visibility enhancement and phase calculation in double-pulsed addition ESPI. J Mod Opt 43:1829–1844CrossRef
19.
Zurück zum Zitat Zhang D, Arola DD (2004) Applications of digital image correlation to biological tissues. J Biomed Opt 9(4):691–699CrossRef Zhang D, Arola DD (2004) Applications of digital image correlation to biological tissues. J Biomed Opt 9(4):691–699CrossRef
20.
Zurück zum Zitat Parks VJ (1982) Strain measurement using grids. Opt Eng 21:633–9 Parks VJ (1982) Strain measurement using grids. Opt Eng 21:633–9
21.
Zurück zum Zitat Goldrein HT, Palmer SJP, Huntley JM (1995) Automated fine grid technique for measurement of large-strain deformation maps. Opt Lasers Eng 23:305–18CrossRef Goldrein HT, Palmer SJP, Huntley JM (1995) Automated fine grid technique for measurement of large-strain deformation maps. Opt Lasers Eng 23:305–18CrossRef
22.
Zurück zum Zitat Peters WH, Ranson WF (1981) Digital imaging techniques in experimental stress analysis. Opt Eng 21:427–31 Peters WH, Ranson WF (1981) Digital imaging techniques in experimental stress analysis. Opt Eng 21:427–31
23.
Zurück zum Zitat Chu TC, Ranson WF, Sutton MA (1985) Applications of digital-image-correlation techniques to experimental mechanics. Exp Mech 25(3):232–44CrossRef Chu TC, Ranson WF, Sutton MA (1985) Applications of digital-image-correlation techniques to experimental mechanics. Exp Mech 25(3):232–44CrossRef
24.
Zurück zum Zitat Berfield TA, Patel JK, Shimmin RG, Braun PV, Lambros J, Sottos NR (2007) Micro- and nanoscale deformation measurement of surface and internalpPlanes via digital image correlation. Exp Mech 47:51–62CrossRef Berfield TA, Patel JK, Shimmin RG, Braun PV, Lambros J, Sottos NR (2007) Micro- and nanoscale deformation measurement of surface and internalpPlanes via digital image correlation. Exp Mech 47:51–62CrossRef
25.
Zurück zum Zitat Davea S, Songa X, Hofmanna F, Dragnevskia K, Korsunsky AM (2009) Digital image correlation and finite element analysis of inter- and intra-granular deformation. Procedia Eng 1:197–200CrossRef Davea S, Songa X, Hofmanna F, Dragnevskia K, Korsunsky AM (2009) Digital image correlation and finite element analysis of inter- and intra-granular deformation. Procedia Eng 1:197–200CrossRef
26.
Zurück zum Zitat Sztefek P, Vanleene M, Olsson R, Collinson R, Pitsillides AA, Shefelbine S (2009) Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia. J Biomech. doi:10.1016/j.jbiomech.2009.10.042 Sztefek P, Vanleene M, Olsson R, Collinson R, Pitsillides AA, Shefelbine S (2009) Using digital image correlation to determine bone surface strains during loading and after adaptation of the mouse tibia. J Biomech. doi:10.​1016/​j.​jbiomech.​2009.​10.​042
27.
Zurück zum Zitat Gonzalez J, Knauss WG (1998) Strain inhomogeneity and discontinuous crack growth in particulate composite. J Mech Phys Solids 35(09):1981–1985CrossRef Gonzalez J, Knauss WG (1998) Strain inhomogeneity and discontinuous crack growth in particulate composite. J Mech Phys Solids 35(09):1981–1985CrossRef
28.
Zurück zum Zitat Choi S, Shah SP (1997) Measurement of deformations on concrete subjected to compression using image correlation. Exp Mech 37(3):307–313CrossRef Choi S, Shah SP (1997) Measurement of deformations on concrete subjected to compression using image correlation. Exp Mech 37(3):307–313CrossRef
29.
Zurück zum Zitat Wang Y, Cuitiño AM (2002) Full-field measurements of heterogeneous deformation patterns on polymeric foams using digital image correlation. Int J Solids Struct 39(13–14):3777–3796CrossRef Wang Y, Cuitiño AM (2002) Full-field measurements of heterogeneous deformation patterns on polymeric foams using digital image correlation. Int J Solids Struct 39(13–14):3777–3796CrossRef
30.
Zurück zum Zitat Tong W (1997) Detection of plastic deformation patterns in a binary aluminum alloy. Exp Mech 37(4):452–459CrossRef Tong W (1997) Detection of plastic deformation patterns in a binary aluminum alloy. Exp Mech 37(4):452–459CrossRef
31.
Zurück zum Zitat Bastawros AF, Bart-Smith H, Evans AG (2000) Experimental analysis of deformation mechanisms in a closed-cell aluminum alloy foam. J Mech Phys Solids 48(2):301–322CrossRefMATH Bastawros AF, Bart-Smith H, Evans AG (2000) Experimental analysis of deformation mechanisms in a closed-cell aluminum alloy foam. J Mech Phys Solids 48(2):301–322CrossRefMATH
32.
Zurück zum Zitat Zink AG, Davidson RW, Hanna RB (1995) Strain measurement in wood using a digital image correlation technique. Wood Fiber Sci 27(4):346–359 Zink AG, Davidson RW, Hanna RB (1995) Strain measurement in wood using a digital image correlation technique. Wood Fiber Sci 27(4):346–359
33.
Zurück zum Zitat Samarasinghe S, Kulasiri D, Nicolle K (1997) Study of mode-I and mixed-mode fracture in wood using digital image correlation method. Proceedings of International Wood Engineering Conference, Louisiana, USA Samarasinghe S, Kulasiri D, Nicolle K (1997) Study of mode-I and mixed-mode fracture in wood using digital image correlation method. Proceedings of International Wood Engineering Conference, Louisiana, USA
34.
Zurück zum Zitat Chow CL, Lu TJ (1989) On evolution law of anisotropic damage. Eng Fract Mech 34(3):679–701CrossRef Chow CL, Lu TJ (1989) On evolution law of anisotropic damage. Eng Fract Mech 34(3):679–701CrossRef
Metadaten
Titel
Multi-scale Mechanical Characterization of Palmetto Wood using Digital Image Correlation to Develop a Template for Biologically-Inspired Polymer Composites
verfasst von
S. Haldar
N. Gheewala
K. J. Grande-Allen
M. A. Sutton
H. A. Bruck
Publikationsdatum
01.04.2011
Verlag
Springer US
Erschienen in
Experimental Mechanics / Ausgabe 4/2011
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-010-9422-7

Weitere Artikel der Ausgabe 4/2011

Experimental Mechanics 4/2011 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.