3D Digital Volume Correlation of Synchrotron Radiation Laminography Images of Ductile Crack Initiation: An Initial Feasibility Study

verfasst von: T. F. Morgeneyer, L. Helfen, H. Mubarak, F. Hild

Erschienen in: Experimental Mechanics | Ausgabe 4/2013

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

A feasibility study of measuring 3D displacement fields in the bulk during ductile crack initiation via combined Synchrotron Radiation Computed Laminography (SRCL) and Digital Volume Correlation (DVC) is performed. In contrast to tomography, SRCL is a technique that is particularly adapted to obtain three-dimensional (3D) reconstructed volumes of objects that are laterally extended (i.e., in 2 directions) and thin in the third direction, i.e. sheet-like objects. In-situ laminography data of an initiating crack ahead of a machined notch are used with a voxel size of 0.7 μm. The natural contrast of the observed 2XXX Al-alloy caused by intermetallic particles and initial porosity is used to measure displacement fields via a global DVC technique assuming a continuous displacement field. An initial performance study is carried out on data of the same undeformed material but after a substantial shift of the laminography rotation axis with respect to the imaged specimen. Volume correlations between different loading steps provide displacement fields that are qualitatively consistent with the remote loading conditions. Computed strain fields display a strain concentration close to the notch tip.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
The resolution of a measuring system is the ‘smallest change in a quantity being measured that causes a perceptible change in the corresponding indication’ [42]. With this definition, high resolution levels do not allow small fluctuations to be measured.
 
Literatur
1.
Zurück zum Zitat Zerbst U, Heinimann M, Dalle Donne C, Steglich D (2009) Fracture and damage mechanics modelling of thin-walled structures. An overview. Eng Fract Mech 76:5–43CrossRef Zerbst U, Heinimann M, Dalle Donne C, Steglich D (2009) Fracture and damage mechanics modelling of thin-walled structures. An overview. Eng Fract Mech 76:5–43CrossRef
2.
Zurück zum Zitat Chen J, Madi Y, Morgeneyer TF, Besson J (2011) Plastic flow and ductile rupture of a 2198 Al-Cu-Li aluminium alloy. Comp Mat Sci 50:1365–1371CrossRef Chen J, Madi Y, Morgeneyer TF, Besson J (2011) Plastic flow and ductile rupture of a 2198 Al-Cu-Li aluminium alloy. Comp Mat Sci 50:1365–1371CrossRef
3.
Zurück zum Zitat Le Jolu T, Morgeneyer TF, Gourgues-Lorenzon A-F (2010) Effect of joint line remnant on fatigue lifetime of friction stir welded Al-Cu-Li alloy. Sci Tech Weld Join 15:694–698CrossRef Le Jolu T, Morgeneyer TF, Gourgues-Lorenzon A-F (2010) Effect of joint line remnant on fatigue lifetime of friction stir welded Al-Cu-Li alloy. Sci Tech Weld Join 15:694–698CrossRef
4.
Zurück zum Zitat Mahgoub E, Deng X, Sutton MA (2003) Three dimensional stress and deformation fields around flat and slant cracks under remote mode I loading conditions. Eng Fract Mech 70:2527–2542CrossRef Mahgoub E, Deng X, Sutton MA (2003) Three dimensional stress and deformation fields around flat and slant cracks under remote mode I loading conditions. Eng Fract Mech 70:2527–2542CrossRef
5.
Zurück zum Zitat Lorthios J, Nguyen F, Gourgues-Lorenzon A-F, Morgeneyer TF, Cugy P (2010) Damage observation in a high manganese austenitic Twinning Induced Plasticity (TWIP) steel by synchrotron radiation computed tomography. Scr Mat 63:1220–1223CrossRef Lorthios J, Nguyen F, Gourgues-Lorenzon A-F, Morgeneyer TF, Cugy P (2010) Damage observation in a high manganese austenitic Twinning Induced Plasticity (TWIP) steel by synchrotron radiation computed tomography. Scr Mat 63:1220–1223CrossRef
6.
Zurück zum Zitat Morgeneyer TF, Besson J (2011) Flat to slant ductile fracture transition: tomography examination and simulations using shear controlled void nucleation. Scr Mat 65:1002–1005CrossRef Morgeneyer TF, Besson J (2011) Flat to slant ductile fracture transition: tomography examination and simulations using shear controlled void nucleation. Scr Mat 65:1002–1005CrossRef
7.
Zurück zum Zitat Maire E, Zhou S, Adrien J, Dimichiel M (2011) Damage quantification in aluminium alloys using in situ tensile tests in X-ray tomography. Eng Fract Mech 78:2679–2690CrossRef Maire E, Zhou S, Adrien J, Dimichiel M (2011) Damage quantification in aluminium alloys using in situ tensile tests in X-ray tomography. Eng Fract Mech 78:2679–2690CrossRef
8.
Zurück zum Zitat Landron C, Bouaziz O, Maire E, Adrien J (2010) Characterization and modeling of void nucleation by interface decohesion in dual phase steels. Scr Mat 63:973–976CrossRef Landron C, Bouaziz O, Maire E, Adrien J (2010) Characterization and modeling of void nucleation by interface decohesion in dual phase steels. Scr Mat 63:973–976CrossRef
9.
Zurück zum Zitat Maire E, Morgeneyer TF, Landron C, Adrien J, Helfen L (2012) Bulk evaluation of ductile damage development using high resolution tomography and laminography. C R Phys 13:328–336CrossRef Maire E, Morgeneyer TF, Landron C, Adrien J, Helfen L (2012) Bulk evaluation of ductile damage development using high resolution tomography and laminography. C R Phys 13:328–336CrossRef
10.
Zurück zum Zitat Helfen L, Myagotin A, Mikulík P, Pernot P, Voropaev A, Elyyan M, Di Michiel M, Baruchel J, Baumbach T (2011) On the implementation of computed laminography using synchrotron radiation. Rev Sci Instrum 82 Helfen L, Myagotin A, Mikulík P, Pernot P, Voropaev A, Elyyan M, Di Michiel M, Baruchel J, Baumbach T (2011) On the implementation of computed laminography using synchrotron radiation. Rev Sci Instrum 82
11.
Zurück zum Zitat Helfen L, Morgeneyer TF, Xu F, Mavrogordato MN, Sinclair I, Schillinger B, Baumbach T (2012) Synchrotron and neutron laminography for three-dimensional imaging of devices and flat material specimens. Int J Mater Res 2012:170–173CrossRef Helfen L, Morgeneyer TF, Xu F, Mavrogordato MN, Sinclair I, Schillinger B, Baumbach T (2012) Synchrotron and neutron laminography for three-dimensional imaging of devices and flat material specimens. Int J Mater Res 2012:170–173CrossRef
12.
Zurück zum Zitat Maurel V, Helfen L, N’Guyen F, Köster A, Di Michiel M, Baumbach T, Morgeneyer TF (2012) Three-dimensional investigation of thermal barrier coatings by synchrotron-radiation computed laminography. Scr Mat 66:471–474CrossRef Maurel V, Helfen L, N’Guyen F, Köster A, Di Michiel M, Baumbach T, Morgeneyer TF (2012) Three-dimensional investigation of thermal barrier coatings by synchrotron-radiation computed laminography. Scr Mat 66:471–474CrossRef
13.
Zurück zum Zitat Moffat AJ, Wright P, Helfen L, Baumbach T, Johnson G, Spearing SM, Sinclair I (2010) In situ synchrotron computed laminography of damage in carbon fibre-epoxy [90/0]s laminates. Scr Mat 62:97–100CrossRef Moffat AJ, Wright P, Helfen L, Baumbach T, Johnson G, Spearing SM, Sinclair I (2010) In situ synchrotron computed laminography of damage in carbon fibre-epoxy [90/0]s laminates. Scr Mat 62:97–100CrossRef
14.
Zurück zum Zitat Morgeneyer TF, Helfen L, Sinclair I, Proudhon H, Xu F, Baumbach T (2011) Ductile crack initiation and propagation assessed via in situ synchrotron radiation computed laminography. Scr Mat 65:1010–1013CrossRef Morgeneyer TF, Helfen L, Sinclair I, Proudhon H, Xu F, Baumbach T (2011) Ductile crack initiation and propagation assessed via in situ synchrotron radiation computed laminography. Scr Mat 65:1010–1013CrossRef
15.
Zurück zum Zitat Sutton MA, Orteu J-J, Schreier H (2009) Image correlation for shape, motion and deformation measurements: basic concepts. Theory and Applications, Springer Sutton MA, Orteu J-J, Schreier H (2009) Image correlation for shape, motion and deformation measurements: basic concepts. Theory and Applications, Springer
16.
Zurück zum Zitat Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39:217–226CrossRef
17.
Zurück zum Zitat Smith TS, Bay BK, Rashid MM (2002) Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech 42:272–278CrossRef Smith TS, Bay BK, Rashid MM (2002) Digital volume correlation including rotational degrees of freedom during minimization. Exp Mech 42:272–278CrossRef
18.
Zurück zum Zitat Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l′analyse des matériaux et des structures. Inst Mes Métrol 4:43–88 Bornert M, Chaix J-M, Doumalin P, Dupré J-C, Fournel T, Jeulin D, Maire E, Moreaud M, Moulinec H (2004) Mesure tridimensionnelle de champs cinématiques par imagerie volumique pour l′analyse des matériaux et des structures. Inst Mes Métrol 4:43–88
19.
Zurück zum Zitat Verhulp E, van Rietbergen B, Huiskes R (2004) A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech 37:1313–1320CrossRef Verhulp E, van Rietbergen B, Huiskes R (2004) A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech 37:1313–1320CrossRef
20.
Zurück zum Zitat Liu L, Morgan E (2007) Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. J Biomech 40:3516–3520CrossRef Liu L, Morgan E (2007) Accuracy and precision of digital volume correlation in quantifying displacements and strains in trabecular bone. J Biomech 40:3516–3520CrossRef
21.
Zurück zum Zitat Forsberg F, Mooser R, Arnold M, Hack E, Wyss P (2008) 3D Micro-scale deformations of wood in bending: synchrotron radiation μCT data analyzed with digital volume correlation. J Struct Biol 164:255–262CrossRef Forsberg F, Mooser R, Arnold M, Hack E, Wyss P (2008) 3D Micro-scale deformations of wood in bending: synchrotron radiation μCT data analyzed with digital volume correlation. J Struct Biol 164:255–262CrossRef
22.
Zurück zum Zitat Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51:2407–2415CrossRef Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51:2407–2415CrossRef
23.
Zurück zum Zitat Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X ray microtomography images. Acta Mater 57:4090–4101CrossRef Limodin N, Réthoré J, Buffière J-Y, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using 3D correlation of laboratory X ray microtomography images. Acta Mater 57:4090–4101CrossRef
24.
Zurück zum Zitat Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-Ray computed tomography of solid foam. Comp Part A 39:1253–1265CrossRef Roux S, Hild F, Viot P, Bernard D (2008) Three dimensional image correlation from X-Ray computed tomography of solid foam. Comp Part A 39:1253–1265CrossRef
25.
Zurück zum Zitat Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Mecanique 336:643–649MATHCrossRef Réthoré J, Tinnes J-P, Roux S, Buffière J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Mecanique 336:643–649MATHCrossRef
26.
Zurück zum Zitat Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Meth Appl Mech Eng 199:1307–1325MATHCrossRef Rannou J, Limodin N, Réthoré J, Gravouil A, Ludwig W, Baïetto M-C, Buffière J-Y, Combescure A, Hild F, Roux S (2010) Three dimensional experimental and numerical multiscale analysis of a fatigue crack. Comput Meth Appl Mech Eng 199:1307–1325MATHCrossRef
27.
Zurück zum Zitat Limodin N, Réthoré J, Buffière J-Y, Hild F, Roux S, Ludwig W, Rannou J, Gravouil A (2010) Influence of closure on the 3D propagation of fatigue cracks in a nodular cast iron investigated by X-ray tomography and 3D volume correlation. Acta Mater 58:2957–2967CrossRef Limodin N, Réthoré J, Buffière J-Y, Hild F, Roux S, Ludwig W, Rannou J, Gravouil A (2010) Influence of closure on the 3D propagation of fatigue cracks in a nodular cast iron investigated by X-ray tomography and 3D volume correlation. Acta Mater 58:2957–2967CrossRef
28.
Zurück zum Zitat Morgeneyer TF, Besson J, Proudhon H, Starink MJ, Sinclair I (2009) Experimental and numerical analysis of toughness anisotropy in AA2139 Al-alloy sheet. Acta Mater 57:3902–3915CrossRef Morgeneyer TF, Besson J, Proudhon H, Starink MJ, Sinclair I (2009) Experimental and numerical analysis of toughness anisotropy in AA2139 Al-alloy sheet. Acta Mater 57:3902–3915CrossRef
29.
Zurück zum Zitat Helfen L, Baumbach T, Mikulík P, Kiel D, Pernot P, Cloetens P, Baruchel J (2005) High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography. Appl Phys Lett 86 Helfen L, Baumbach T, Mikulík P, Kiel D, Pernot P, Cloetens P, Baruchel J (2005) High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography. Appl Phys Lett 86
30.
Zurück zum Zitat Helfen L, Myagotin A, Rack A, Pernot P, Mikulík P, Di Michiel M, Baumbach T (2007) Synchrotron-radiation computed laminography for high-resolution three-dimensional imaging of flat devices. Phys Stat Sol (a) 204:2760–2765CrossRef Helfen L, Myagotin A, Rack A, Pernot P, Mikulík P, Di Michiel M, Baumbach T (2007) Synchrotron-radiation computed laminography for high-resolution three-dimensional imaging of flat devices. Phys Stat Sol (a) 204:2760–2765CrossRef
31.
Zurück zum Zitat Xu F, Helfen L, Baumbach T, Suhonen H (2012) Comparison of image quality in computed laminography and tomography. Opt Express 20:794–806CrossRef Xu F, Helfen L, Baumbach T, Suhonen H (2012) Comparison of image quality in computed laminography and tomography. Opt Express 20:794–806CrossRef
32.
Zurück zum Zitat Helfen L, Baumbach T, Cloetens P, Baruchel J (2009) Phase contrast and holographic computed laminography. Appl Phys Lett 94 Helfen L, Baumbach T, Cloetens P, Baruchel J (2009) Phase contrast and holographic computed laminography. Appl Phys Lett 94
33.
Zurück zum Zitat Xu F, Helfen L, Moffat AJ, Johnson G, Sinclair I, Baumbach T (2010) Synchrotron radiation computed laminography for polymer composite failure studies. J Synchron Radiat 17:222–226CrossRef Xu F, Helfen L, Moffat AJ, Johnson G, Sinclair I, Baumbach T (2010) Synchrotron radiation computed laminography for polymer composite failure studies. J Synchron Radiat 17:222–226CrossRef
34.
Zurück zum Zitat Harasse S, Hirayama N, Yashiro W, Momose A (2010) X-ray phase laminography with Talbot interferometer. Proc SPIE 7804 Harasse S, Hirayama N, Yashiro W, Momose A (2010) X-ray phase laminography with Talbot interferometer. Proc SPIE 7804
35.
Zurück zum Zitat Altapova V, Helfen L, Myagotin A, Hänschke D, Moosmann J, Gunneweg J, Baumbach T (2012) Phase contrast laminography based on Talbot interferometry. Opt Express 20:6496–6508CrossRef Altapova V, Helfen L, Myagotin A, Hänschke D, Moosmann J, Gunneweg J, Baumbach T (2012) Phase contrast laminography based on Talbot interferometry. Opt Express 20:6496–6508CrossRef
36.
Zurück zum Zitat Krug K, Porra L, Coan P, Wallert A, Dik J, Coerdt A, Bravin A, Elyyan M, Reischig P, Helfen L, Baumbach T (2008) Relics in medieval altarpieces? Combining X ray tomographic, laminographic and phase contrast imaging to visualize thin organic objects. J Synchron Radiat 15:55–61CrossRef Krug K, Porra L, Coan P, Wallert A, Dik J, Coerdt A, Bravin A, Elyyan M, Reischig P, Helfen L, Baumbach T (2008) Relics in medieval altarpieces? Combining X ray tomographic, laminographic and phase contrast imaging to visualize thin organic objects. J Synchron Radiat 15:55–61CrossRef
37.
Zurück zum Zitat Weitkamp T, Tafforeau P, Boller E, Cloetens P, Valade J-P, Bernard P, Peyrin F, Ludwig W, Helfen L, Baruchel J (2010) Status and evolution of the ESRF beamline ID19. In. ICXOM 2009, AIP Conf. Proc Weitkamp T, Tafforeau P, Boller E, Cloetens P, Valade J-P, Bernard P, Peyrin F, Ludwig W, Helfen L, Baruchel J (2010) Status and evolution of the ESRF beamline ID19. In. ICXOM 2009, AIP Conf. Proc
38.
Zurück zum Zitat Rack A, Weitkamp T, Riotte M, Grigoriev D, Rack T, Helfen L, Baumbach T, Dietsch R, Holz T, Krämer M, Siewert F, Meduna M, Cloetens P, Ziegler E (2010) Comparative study of multilayers used in monochromators for synchrotron-based coherent hard X-ray imaging. J Synchron Radiat 17:496–510CrossRef Rack A, Weitkamp T, Riotte M, Grigoriev D, Rack T, Helfen L, Baumbach T, Dietsch R, Holz T, Krämer M, Siewert F, Meduna M, Cloetens P, Ziegler E (2010) Comparative study of multilayers used in monochromators for synchrotron-based coherent hard X-ray imaging. J Synchron Radiat 17:496–510CrossRef
39.
Zurück zum Zitat Sijbers J, Postnovz A (2004) Reduction of ring artefacts in high resolution micro-CT reconstructions. Phys Med Biol 49:247–253CrossRef Sijbers J, Postnovz A (2004) Reduction of ring artefacts in high resolution micro-CT reconstructions. Phys Med Biol 49:247–253CrossRef
40.
Zurück zum Zitat Cloetens P, Pateyron-Salomé M, Buffière J-Y, Peix G, Baruchel J, Peyrin F, Schlenker M (1997) Observation of microstructure and damage in materials by phase sensitive radiography and tomography. J Appl Phys 81 Cloetens P, Pateyron-Salomé M, Buffière J-Y, Peix G, Baruchel J, Peyrin F, Schlenker M (1997) Observation of microstructure and damage in materials by phase sensitive radiography and tomography. J Appl Phys 81
41.
Zurück zum Zitat Zienkievicz OC, Taylor RL (1989) The Finite Element Method. McGraw-Hill Zienkievicz OC, Taylor RL (1989) The Finite Element Method. McGraw-Hill
42.
Zurück zum Zitat 99-12:2007 IIg. International Vocabulary of Metrology—Basic and General Concepts and Associated Terms, VIM. International Organization for Standardization; 2007 99-12:2007 IIg. International Vocabulary of Metrology—Basic and General Concepts and Associated Terms, VIM. International Organization for Standardization; 2007
43.
Zurück zum Zitat Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef Hild F, Maire E, Roux S, Witz J-F (2009) Three dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320CrossRef
44.
Zurück zum Zitat Limodin N, Réthoré J, Adrien J, Buffière J-Y, Hild F, Roux S (2011) Analysis and artifact correction for volume correlation measurements using tomographic images from a laboratory X-ray source. Exp Mech 51:959–970CrossRef Limodin N, Réthoré J, Adrien J, Buffière J-Y, Hild F, Roux S (2011) Analysis and artifact correction for volume correlation measurements using tomographic images from a laboratory X-ray source. Exp Mech 51:959–970CrossRef
45.
Zurück zum Zitat Leclerc H, Périé J-N, Hild F, Roux S (2012) Digital volume correlation: what are the limits to the spatial resolution? Méc & Indust., submitted Leclerc H, Périé J-N, Hild F, Roux S (2012) Digital volume correlation: what are the limits to the spatial resolution? Méc & Indust., submitted
Metadaten
Titel
3D Digital Volume Correlation of Synchrotron Radiation Laminography Images of Ductile Crack Initiation: An Initial Feasibility Study
verfasst von
T. F. Morgeneyer
L. Helfen
H. Mubarak
F. Hild
Publikationsdatum
01.04.2013
Verlag
Springer US
Erschienen in
Experimental Mechanics / Ausgabe 4/2013
Print ISSN: 0014-4851
Elektronische ISSN: 1741-2765
DOI
https://doi.org/10.1007/s11340-012-9660-y

Weitere Artikel der Ausgabe 4/2013

Experimental Mechanics 4/2013 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.