Abstract
Air quality in urban areas attracts great attention due to increasing pollutant emissions and their negative effects on human health and environment. Numerous studies, such as those by Mouilleau and Champassith (J Loss Prevent Proc 22(3): 316–323, 2009), Xie et al. (J Hydrodyn 21(1): 108–117, 2009), and Yassin (Environ Sci Pollut Res 20(6): 3975–3988, 2013) focus on the air pollutant dispersion with no buoyancy effect or weak buoyancy effect. A few studies, such as those by Hu et al. (J Hazard Mater 166(1): 394–406, 2009; J Hazard Mater 192(3): 940–948, 2011; J Civ Eng Manag (2013)) focus on the fire-induced dispersion of pollutants with heat buoyancy release rate in the range from 0.5 to 20 MW. However, the air pollution source might very often be concentrated and intensive, as a consequence of the hazardous materials fire. Namely, transportation of fuel through urban areas occurs regularly, because it is often impossible to find alternative supply routes. It is accompanied with the risk of fire accident occurrences. Accident prevention strategies require analysis of the worst scenarios in which fire products jeopardize the exposed population and environment. The aim of this article is to analyze the impact of wind flow on air pollution and human vulnerability to fire products in a street canyon. For simulation of the gasoline tanker truck fire as a result of a multivehicle accident, computational fluid dynamics large eddy simulation method has been used. Numerical results show that the fire products flow vertically upward, without touching the walls of the buildings in the absence of wind. However, when the wind velocity reaches the critical value, the products touch the walls of the buildings on both sides of the street canyon. The concentrations of carbon monoxide and soot decrease, whereas carbon dioxide concentration increases with the rise of height above the street canyon ground level. The longitudinal concentration of the pollutants inside the street increases with the rise of the wind velocity at the roof level of the street canyon.
Similar content being viewed by others
References
Anwar K, Ejaz S, Ashraf M, Ahmad N, Javeed A (2012) Monitoring trace elements generated by automobiles: air pollutants with possible health impacts. Environ Sci Pollut Res, DOI 10.1007/s11356-012-1383-1
Assimakopoulos VD, Apsimon HM, Moussiopoulos NA (2003) A numerical study of atmospheric pollutant dispersion in different two-dimensional street canyon configurations. Atmos Environ 37(29):4037–4049
Ballach HJ, Wittig R, Wulff S (2002) Twenty-five years of biomonitoring lead in the Frankfurt/main area. Environ Sci Pollut Res 9(2):136–142
Baum HR, MaCaffery BJ (1989) Fire induced flow field—theory and experiment. Fire safety science. In: Proceedings of the second international symposium: 129–48
Buccolieri R, Sandberg M, Di Sabatino S (2010) City breathability and its link to pollutant concentration distribution within urban-like geometries. Atmos Environ 44(15):1894–1903
Button NP, Reilly PM (2000) Uncertainty in incident rates for trucks carrying dangerous goods. Accident Anal Prev 32(6):797–804
Chang CH, Meroney R (2003) Concentration and flow distributions in urban street canyons: wind tunnel and computational data. J Wind Eng Ind Aerod 91(9):1141–1154
Di Sabatino S, Buccolieri R, Pulvirenti B, Britter RE (2008) Flow and pollutant dispersion in street canyons using FLUENT and ADMS-Urban. Environ Model Assess 13(3):369–381
Drysdale D (2011) An introduction to fire dynamics, Wiley & Sons
Gaga EO, Döğeroğlu T, Özden Ö, Ari A, Yay OD, Altuğ H, Akyol N, Örnektekin S, Van Doorn W (2012) Evaluation of air quality by passive and active sampling in an urban city in Turkey: current status and spatial analysis of air pollution exposure. Environ Sci Pollut Res 19(8):3579–3596
Galatioto F, Bell MC (2013) Exploring the processes governing roadside pollutant concentrations in urban street canyon. Environ Sci Pollut Res, DOI 10.1007/s11356-012-1428-5
Hu LH, Fong NK, Yang LZ, Chow WK, Li YZ, Huo R (2007) Modeling fire-induced smoke spread and carbon monoxide transportation in a long channel: Fire Dynamics Simulator comparisons with measured data. J Hazard Mater 140:293–298
Hu LH, Huo R, Yang D (2009) Large eddy simulation of fire-induced buoyancy driven plume dispersion in an urban street canyon under perpendicular wind flow. J Hazard Mater 166(1):394–406
Hu LH, Xu Y, Zhu W, Wu L, Tang F, Lu KH (2011) Large eddy simulation of pollutant gas dispersion with buoyancy ejected from building into an urban street canyon. J Hazard Mater 192(3):940–948
Hu LH, Zhang XC, Zhu W, Ning Z, A global relation of fire smoke re-circulation behavior in urban street canyons, J Civ Eng Manag (in press);
Jovanović V, Tica S, Milovanović B, Živanović P (2009) Researching and analyzing the features of oil and demand for transporting oil derivates in the area of Belgrade. Transport-Vilnius 24(3):249–256
Kim JJ, Baik JJ (2004) A numerical study of the effects of ambient wind direction on flow and dispersion in urban street canyons using the RNG k–ε turbulence model. Atmos Environ 38(19):3039–3048
McGrattan KB (2005) Numerical simulation of the Caldecott tunnel fire, April 1982, National Institute of Standards and `nology, Washington
McGrattan K, Hostikka S, Floyd J, Baum H, Mell RRW, McDermott R (2009) Fire Dynamics Simulator (version 5.4) Technical reference guide. National Institute of Standards and Technology, Washington
Mouilleau Y, Champassith A (2009) CFD Simulations of atmospheric gas dispersion using the Fire Dynamics Simulator (FDS). J Loss Prevent Proc 22(3):316–323
Pesic DJ, Blagojevic MD, Glisovic SM (2011) The model of air pollution generated by fire chemical accident in an urban street canyon. Transport Res D-Tr E 16(4):321–326
Rehm RG, Baum HR (1978) The equations of motion for thermally driven, buoyant flows. J Res NBS 83:297–308
Richardson LF (1922) Weather prediction by numerical process. Cambridge University Press, Cambridge
Rinne T, Hietaniemi J, Hostikka S (2007) Experimental validation of the FDS simulations of smoke and toxic gas concentrations. VTT, Finland
Salizzoni P, Grosjean N, Mejean P, Perkins RJ, Soulhac L, Vanliefferinge R (2007) Wind tunnel study of the exchange between a street canyon and the external flow, Air Pollut Model Appl XVII:430–437.
Smagorinsky J (1963) General circulation experiments with the primitive equationsI. The basic experiment. Mon Weather Rev 91(3):99–164
Vardoulakis S, Fisher BEA, Pericleous K, Gonzalez-Flesca N (2003) Modelling air quality in street canyons: a review. Atmos Environ 37(2):155–182
Venegas LE, Mazzeo NA (2000) Carbon monoxide concentration in a street canyon of Buenos Aires City (Argentina). Environ Monit Assess 65(1–2):417–423
Xia JY, Hussaini MY, Leung DYC (2005) Numerical simulation of street canyon flows with simple building geometries. J Environ Eng-ASCE 131(7):1099–1105
Xie S, Zhang Y, Qi L, Tang X (2003) Spatial distribution of traffic-related pollutant concentrations in street canyons. Atmos Environ 37(23):3213–3224
Xie X, Wang J, Huang Z (2009) Traffic emission transportation in street canyons. J Hydrodyn 21(1):108–117
Yassin MF (2013) Numerical modeling on air quality in an urban environment with changes of the aspect ratio and wind direction. Environ Sci Pollut Res 20(6):3975–3988
Zeng WR, Chow WK (2011) A note on modeling combustion of common fuels with mixture fraction. Int J Eng Performance-Based Fire Codes 10(1):6–11
Zhang XC, Hu LH, Tang F, Wang Q (2012) Large eddy simulation of fire smoke dispersion re-circulation in urban street canyons of different aspect ratios. The 9th Asia-Oceania Symposium on Fire Science and Technology, Oct. 18-22, Hefei, China
Acknowledgments
The research described in this article was realized as part of the scientific project: “Improvement of monitoring system and assessment of long-term population exposure to environmental pollutants using neural networks” funded by The Ministry of Education and Science of the Republic of Serbia.
Author information
Authors and Affiliations
Corresponding author
Additional information
Resposible editor: Michael Matthies
Rights and permissions
About this article
Cite this article
Pesic, D.J., Blagojevic, M.D. & Zivkovic, N.V. Simulation of wind-driven dispersion of fire pollutants in a street canyon using FDS. Environ Sci Pollut Res 21, 1270–1284 (2014). https://doi.org/10.1007/s11356-013-1999-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11356-013-1999-9