Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 7/2006

01.07.2006 | Original Article

Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis

verfasst von: Kivanc Akca, Murat Cavit Cehreli

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 7/2006

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

The purpose of this study was to explore the biomechanical effects of progressive marginal bone loss in the peri-implant bone. Finite element model of a Ø 4.1 × 10 mm Straumann dental implant and a solid abutment was constructed as predefined eight-layers around the implant neck. The implant-abutment complex was embedded in a cylindrical bone model to analyze bone biomechanics regardless of anatomical influences. Angular and circular progressive marginal bone loss was simulated by sequential removal of each layer, resulting crater-like defects and a total of ten finite element models for analysis. Each model was subjected to a vertical and oblique static load of 100 N in separate load cases. Principal stress minimum and maximum, displacement, and equivalent of elastic strain outcomes were compared. Under vertical loading, principal stresses minimum and maximum decreased remarkably as with the increase in bone resorption. Under oblique load simulations, decrease in principal stress maximum and minimum was evident. With progressive bone loss and under oblique load simulations, displacement and equivalent of elastic strain increased considerably in trabecular bone contacting the implant neck. The presence of cortical bone contacting a load-carrying implant, even in a bone defect, improves the biomechanical performance of implants in comparison with only trabecular bone support as a sequel of progressive marginal bone loss.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Akca K, Cehreli MC, Iplikcioglu H (2003) Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res 14:444–455CrossRef Akca K, Cehreli MC, Iplikcioglu H (2003) Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant. A nonlinear finite element stress analysis. Clin Oral Implants Res 14:444–455CrossRef
2.
Zurück zum Zitat Akca K, Iplikcioglu H (2002) Finite element stress analysis of the effect of short -implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil 4:350–356CrossRef Akca K, Iplikcioglu H (2002) Finite element stress analysis of the effect of short -implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil 4:350–356CrossRef
3.
Zurück zum Zitat Astrand P, Engquist B, Dahlgren S, Engquist E, Feldmann H, Grondahl K (1999) Astra tech and Brånemark system implants: a prospective 5-year comparative study. Results after one year. Clin Implant Dent Relat Res 1:17–26CrossRef Astrand P, Engquist B, Dahlgren S, Engquist E, Feldmann H, Grondahl K (1999) Astra tech and Brånemark system implants: a prospective 5-year comparative study. Results after one year. Clin Implant Dent Relat Res 1:17–26CrossRef
4.
Zurück zum Zitat Barbier L, Schepers E (1997) Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible. Int J Oral Maxillofac Implants 12:215–223 Barbier L, Schepers E (1997) Adaptive bone remodeling around oral implants under axial and nonaxial loading conditions in the dog mandible. Int J Oral Maxillofac Implants 12:215–223
5.
Zurück zum Zitat Brägger U (1998) Use of radiographs in evaluating success, stability and failure in implant dentistry. Periodontol 2000 17:77–88CrossRef Brägger U (1998) Use of radiographs in evaluating success, stability and failure in implant dentistry. Periodontol 2000 17:77–88CrossRef
6.
Zurück zum Zitat Cehreli MC, Akca K, Iplikcioglu H (2004a) Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis. Clin Oral Implants Res 15:481–9CrossRef Cehreli MC, Akca K, Iplikcioglu H (2004a) Force transmission of one- and two-piece morse-taper oral implants: a nonlinear finite element analysis. Clin Oral Implants Res 15:481–9CrossRef
7.
Zurück zum Zitat Cehreli M, Akkocaoğlu. M, Cömert A, Tekdemir I, Akca K (2005) Human ex vivo bone tissue strains around natural teeth versus immediate oral implants. Clin Oral Implants Res 16:540–548CrossRef Cehreli M, Akkocaoğlu. M, Cömert A, Tekdemir I, Akca K (2005) Human ex vivo bone tissue strains around natural teeth versus immediate oral implants. Clin Oral Implants Res 16:540–548CrossRef
8.
Zurück zum Zitat Cehreli M, Sahin S, Akca K (2004b) Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts. J Dent 32:123–132CrossRef Cehreli M, Sahin S, Akca K (2004b) Role of mechanical environment and implant design on bone tissue differentiation: current knowledge and future contexts. J Dent 32:123–132CrossRef
9.
Zurück zum Zitat Cehreli MC, Akca K (2005) Mechanobiology of bone and mechanocoupling of endosseous titanium oral implants. J Long Term Eff Med Implants 15:139–152CrossRef Cehreli MC, Akca K (2005) Mechanobiology of bone and mechanocoupling of endosseous titanium oral implants. J Long Term Eff Med Implants 15:139–152CrossRef
10.
Zurück zum Zitat Davarpanah M, Martinez H, Etienne D, Zabalegui I, Mattout P, Chiche F, Michel JF (2002) A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data. Int J Oral Maxillofac Implants 17:820–8 Davarpanah M, Martinez H, Etienne D, Zabalegui I, Mattout P, Chiche F, Michel JF (2002) A prospective multicenter evaluation of 1,583 3i implants: 1- to 5-year data. Int J Oral Maxillofac Implants 17:820–8
11.
Zurück zum Zitat Esposito M, Hirsch J-M, Lekholm U, Thompsen P (1998). Biological factors contributing to failures of osseointegrated oral implants (II) Etiopathogenesis. Eur J Oral Sci 106:721–764CrossRef Esposito M, Hirsch J-M, Lekholm U, Thompsen P (1998). Biological factors contributing to failures of osseointegrated oral implants (II) Etiopathogenesis. Eur J Oral Sci 106:721–764CrossRef
12.
Zurück zum Zitat Esposito M, Worthington HV, Coulthard P (2001) In search of truth: the role of systematic reviews and meta-analyses for assessing the effectiveness of rehabilitation with oral implants. Clin Implant Dent Relat Res 3:62–78CrossRef Esposito M, Worthington HV, Coulthard P (2001) In search of truth: the role of systematic reviews and meta-analyses for assessing the effectiveness of rehabilitation with oral implants. Clin Implant Dent Relat Res 3:62–78CrossRef
13.
Zurück zum Zitat Frost HM (1987a) Bone “mass” and “mechanostat”, a proposal. Anat Rec 219:1–19CrossRef Frost HM (1987a) Bone “mass” and “mechanostat”, a proposal. Anat Rec 219:1–19CrossRef
14.
Zurück zum Zitat Frost HM (1987b) The mechanostat proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. Bone Miner 2:73–85 Frost HM (1987b) The mechanostat proposed pathogenic mechanism of osteoporoses and the bone mass effects of mechanical and nonmechanical agents. Bone Miner 2:73–85
15.
Zurück zum Zitat Frost HM (1997) Perspective, on our-age related bone loss: Insights from a new paradigm. J Bone Miner Res 12:1539–1546CrossRef Frost HM (1997) Perspective, on our-age related bone loss: Insights from a new paradigm. J Bone Miner Res 12:1539–1546CrossRef
16.
Zurück zum Zitat Goldman FM, Millsap JS, Brenman HS (1957) Origin of registration of the architectural pattern, the lamina dura, and the alveolar crest in the dental radiograph. Oral Surg Oral Med Oral Pathol 10:749–58CrossRef Goldman FM, Millsap JS, Brenman HS (1957) Origin of registration of the architectural pattern, the lamina dura, and the alveolar crest in the dental radiograph. Oral Surg Oral Med Oral Pathol 10:749–58CrossRef
17.
Zurück zum Zitat Goaz PW, White SC (eds) (1987) Oral radiology: principles and interpretation. 176. St Louis: CV Mosby company Goaz PW, White SC (eds) (1987) Oral radiology: principles and interpretation. 176. St Louis: CV Mosby company
18.
Zurück zum Zitat Heitz-Mayfield LJ, Schmid B, Weigel. C, Gerber. S, Bosshardt. DD, Jönsson J, Lang NP (2004) Does excessive occlusal load affect osseointegration? An experimental study in the dog. Clin Oral Implants Res 15:259–268CrossRef Heitz-Mayfield LJ, Schmid B, Weigel. C, Gerber. S, Bosshardt. DD, Jönsson J, Lang NP (2004) Does excessive occlusal load affect osseointegration? An experimental study in the dog. Clin Oral Implants Res 15:259–268CrossRef
19.
Zurück zum Zitat Hoshaw SJ, Brunski JB, Cochran GVB (1994) Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 9:345–360 Hoshaw SJ, Brunski JB, Cochran GVB (1994) Mechanical loading of Brånemark implants affects interfacial bone modeling and remodeling. Int J Oral Maxillofac Implants 9:345–360
20.
Zurück zum Zitat Isidor F (1996) Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 7:143–152CrossRef Isidor F (1996) Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys. Clin Oral Implants Res 7:143–152CrossRef
21.
Zurück zum Zitat Jee WSS (2001) Integrated bone tissue physiology: Anatomy and physiology. In: Cowin SC (eds) Bone mechanics handbook. CRP LLC, Florida, pp 1–35 Jee WSS (2001) Integrated bone tissue physiology: Anatomy and physiology. In: Cowin SC (eds) Bone mechanics handbook. CRP LLC, Florida, pp 1–35
22.
Zurück zum Zitat Kitamura E, Stegaroiu R, Nomura S, Miyakawa O (2004) Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res 15:401–412CrossRef Kitamura E, Stegaroiu R, Nomura S, Miyakawa O (2004) Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clin Oral Implants Res 15:401–412CrossRef
23.
Zurück zum Zitat Kitamura E, Stegaroiu R, Nomura S, Miyakawa O (2005) Influence of marginal bone resorption on stress around an implant – a three-dimensional finite element analysis. J Oral Rehabil 32:279–286CrossRef Kitamura E, Stegaroiu R, Nomura S, Miyakawa O (2005) Influence of marginal bone resorption on stress around an implant – a three-dimensional finite element analysis. J Oral Rehabil 32:279–286CrossRef
24.
Zurück zum Zitat Lang NP, Brëgger U, Walther D, Beamer B, Kornman KS (1993) Ligature-induced periimplant infection in cynomolgus monkeys. I. Clinical and radiographic findings. Clin Oral Implants Res 4:2–11CrossRef Lang NP, Brëgger U, Walther D, Beamer B, Kornman KS (1993) Ligature-induced periimplant infection in cynomolgus monkeys. I. Clinical and radiographic findings. Clin Oral Implants Res 4:2–11CrossRef
25.
Zurück zum Zitat Lindhe J, Berglundh T, Ericsson I, Liljenberg B, Marinello C (1992) Experimental breakdown of peri-implant and periodontal tissues. Clin Oral Implants Res 3:9–16CrossRef Lindhe J, Berglundh T, Ericsson I, Liljenberg B, Marinello C (1992) Experimental breakdown of peri-implant and periodontal tissues. Clin Oral Implants Res 3:9–16CrossRef
26.
Zurück zum Zitat Mellal A, Wiskott HWA, Botsis J, Scherrer SS, Belser UC (2004) Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implants Res 15:239–248CrossRef Mellal A, Wiskott HWA, Botsis J, Scherrer SS, Belser UC (2004) Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implants Res 15:239–248CrossRef
27.
Zurück zum Zitat Melsen B, Lang NP (2001) Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res 12:144–152CrossRef Melsen B, Lang NP (2001) Biological reactions of alveolar bone to orthodontic loading of oral implants. Clin Oral Implants Res 12:144–152CrossRef
28.
Zurück zum Zitat Miyata T, Kobayashi Y, Araki H, Motomura Y, Shin K (1998) The influence of controlled occlusal overload on peri-implant tissue: a histologic study in monkeys. Int J Oral Maxillofac Implants 13:677–683 Miyata T, Kobayashi Y, Araki H, Motomura Y, Shin K (1998) The influence of controlled occlusal overload on peri-implant tissue: a histologic study in monkeys. Int J Oral Maxillofac Implants 13:677–683
29.
Zurück zum Zitat Miyata T, Kobayashi Y, Araki H, Motomura Y, Shin K (2000) The influence of controlled occlusal overload on peri-implant tissue. Part: 3 a histologic study in monkeys. Int J Oral Maxillofac Implants 15:425–431 Miyata T, Kobayashi Y, Araki H, Motomura Y, Shin K (2000) The influence of controlled occlusal overload on peri-implant tissue. Part: 3 a histologic study in monkeys. Int J Oral Maxillofac Implants 15:425–431
30.
Zurück zum Zitat Moberg LE, Kondell PA, Sagulin GB, Bolin A, Heimdahl A, Gynther GW (2001) Brånemark system and ITI dental implant system for treatment of mandibular edentulism. A comparative randomized study 3-year follow-up. Clin Oral Implants Res 12:450–61CrossRef Moberg LE, Kondell PA, Sagulin GB, Bolin A, Heimdahl A, Gynther GW (2001) Brånemark system and ITI dental implant system for treatment of mandibular edentulism. A comparative randomized study 3-year follow-up. Clin Oral Implants Res 12:450–61CrossRef
31.
Zurück zum Zitat Mombelli A (1999) Prevention and therapy of periimplant infections. In: Lang NP, Karring T, Lindhe J (eds) Proceedings of the third European wsorkshop on Periodontology. Quintessenz Verlag, Berlin pp 281–303 Mombelli A (1999) Prevention and therapy of periimplant infections. In: Lang NP, Karring T, Lindhe J (eds) Proceedings of the third European wsorkshop on Periodontology. Quintessenz Verlag, Berlin pp 281–303
32.
Zurück zum Zitat Mericske-Stern R, Piotti M, Sirtes G (1996) 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study. Clin Oral Implants Res 7:387–396CrossRef Mericske-Stern R, Piotti M, Sirtes G (1996) 3-D in vivo force measurements on mandibular implants supporting overdentures. A comparative study. Clin Oral Implants Res 7:387–396CrossRef
33.
Zurück zum Zitat Quirynen M, Naert I, van Steenberghe D (1992) Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 3:1–8CrossRef Quirynen M, Naert I, van Steenberghe D (1992) Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. Clin Oral Implants Res 3:1–8CrossRef
34.
Zurück zum Zitat Ricci G, Aimetti M, Stablum W, Guasti A (2004) Crestal bone resorption 5 years after implant loading: clinical and radiologic results with a 2-stage implant system. Int J Oral Maxillofac Implants 19:597–602 Ricci G, Aimetti M, Stablum W, Guasti A (2004) Crestal bone resorption 5 years after implant loading: clinical and radiologic results with a 2-stage implant system. Int J Oral Maxillofac Implants 19:597–602
35.
Zurück zum Zitat Sanz M, Alandex J, Lazaro P, Calvo JL, Quirynen M, van Steenberghe D (1991) Histopathologic characteristics of peri-implant soft tissues in Branemark implants with 2 district clinical and radiological patterns. Clin Oral Implants Res 2:128–134CrossRef Sanz M, Alandex J, Lazaro P, Calvo JL, Quirynen M, van Steenberghe D (1991) Histopathologic characteristics of peri-implant soft tissues in Branemark implants with 2 district clinical and radiological patterns. Clin Oral Implants Res 2:128–134CrossRef
36.
Zurück zum Zitat Schou S, Holmstrup P, Reibel J, Juhl M, Hjorting-Hansen E, Kornman KS (1993) Ligature-induced marginal inflammation around osseointegrated implants and ankylosed teeth: stereologic and histologic observations in cynomolgus monkeys (Macaca fascicularis). J Periodontol 64:529–537 Schou S, Holmstrup P, Reibel J, Juhl M, Hjorting-Hansen E, Kornman KS (1993) Ligature-induced marginal inflammation around osseointegrated implants and ankylosed teeth: stereologic and histologic observations in cynomolgus monkeys (Macaca fascicularis). J Periodontol 64:529–537
37.
Zurück zum Zitat Turner CH (1999) Toward a mathematical description of bone biology: the principle of cellular accomodation. Calcif Tissue Int 65:466–471CrossRef Turner CH (1999) Toward a mathematical description of bone biology: the principle of cellular accomodation. Calcif Tissue Int 65:466–471CrossRef
38.
Zurück zum Zitat Weber HP, Crohin CC, Fiorellini JP (2000) A 5-year prospective clinical and radiographic study of non-submerged dental implants. Clin Oral Implants Res 11:144–53CrossRef Weber HP, Crohin CC, Fiorellini JP (2000) A 5-year prospective clinical and radiographic study of non-submerged dental implants. Clin Oral Implants Res 11:144–53CrossRef
39.
Zurück zum Zitat Wennström J, Zurdo J, Karlsson S, Ekestubbe A, Gröndahl K, Lindhe J (2004) Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function. J Clin Periodontol 31:1077–1083CrossRef Wennström J, Zurdo J, Karlsson S, Ekestubbe A, Gröndahl K, Lindhe J (2004) Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function. J Clin Periodontol 31:1077–1083CrossRef
Metadaten
Titel
Biomechanical consequences of progressive marginal bone loss around oral implants: a finite element stress analysis
verfasst von
Kivanc Akca
Murat Cavit Cehreli
Publikationsdatum
01.07.2006
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 7/2006
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-006-0072-y

Weitere Artikel der Ausgabe 7/2006

Medical & Biological Engineering & Computing 7/2006 Zur Ausgabe