Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 3/2011

01.03.2011 | Original Article

Effects of micro-magnetic field at the surface of 316L and NiTi alloy on blood compatibility

verfasst von: Qiang Liu, Xiao Nong Cheng, Huang Xia Fei

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 3/2011

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

We have established the micro-magnetic field on the surfaces of 316L stainless steel and NiTi alloy through the magnetization process of sol–gel prepared TiO2 thin film with the powder of SrFe12O19. The nano-sized with brown color of SrFe12O19 powder was verified by transmission electron microscope. By using X-ray diffraction, surface roughometer, and corrosion experimental test, the deposited thin film can decrease the etching of body fluid as well as prevent the hazardous Ni ions released from the metal. Moreover, with evaluation of dynamic cruor time test and blood platelets adhesion test, we found the micro-magnetic field of the thin film can improve the blood compatibility.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Armitage DA, Parker TL, Grant DM (2003) Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J Biomed Mater Res A 66(1):129–137PubMedCrossRef Armitage DA, Parker TL, Grant DM (2003) Biocompatibility and hemocompatibility of surface-modified NiTi alloys. J Biomed Mater Res A 66(1):129–137PubMedCrossRef
2.
Zurück zum Zitat Berry MV, Geim AK (1997) Of flying frog and levitrons. Eur J Phys 18:307–313CrossRef Berry MV, Geim AK (1997) Of flying frog and levitrons. Eur J Phys 18:307–313CrossRef
3.
Zurück zum Zitat Chu CL, Hu T, Wu SL et al (2007) Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidation. Acta Biomater 3(5):795–806PubMedCrossRef Chu CL, Hu T, Wu SL et al (2007) Surface structure and properties of biomedical NiTi shape memory alloy after Fenton’s oxidation. Acta Biomater 3(5):795–806PubMedCrossRef
4.
Zurück zum Zitat Dee KC, Puleo DA, Bizios R (2002) An introduction to tissue–biomaterial interactions. Wiley, Hoboken, NJ ISBN 0-471-25394-4CrossRef Dee KC, Puleo DA, Bizios R (2002) An introduction to tissue–biomaterial interactions. Wiley, Hoboken, NJ ISBN 0-471-25394-4CrossRef
5.
Zurück zum Zitat Gutensohn K, Beythien C, Bau J et al (2000) In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 99(6):577–585PubMedCrossRef Gutensohn K, Beythien C, Bau J et al (2000) In vitro analyses of diamond-like carbon coated stents: reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 99(6):577–585PubMedCrossRef
6.
Zurück zum Zitat Haïdopoulos M, Turgeon S, Sarra-Bournet C et al (2006) Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications. J Mater Sci Mater Med 17(7):647–657PubMedCrossRef Haïdopoulos M, Turgeon S, Sarra-Bournet C et al (2006) Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications. J Mater Sci Mater Med 17(7):647–657PubMedCrossRef
7.
Zurück zum Zitat Higashi T, Yamagishi A, Takeuchi T, Kawaguchi N et al (1993) Orientation of erythrocytes in a strong static magnetic field. Blood 82:1328–1334PubMed Higashi T, Yamagishi A, Takeuchi T, Kawaguchi N et al (1993) Orientation of erythrocytes in a strong static magnetic field. Blood 82:1328–1334PubMed
8.
Zurück zum Zitat Higashi T, Sagawa S, Kawaguchi N, Yamagishi A (1993) Effects of a strong static magnetic field on blood platelets. Platelets 4:341–342PubMedCrossRef Higashi T, Sagawa S, Kawaguchi N, Yamagishi A (1993) Effects of a strong static magnetic field on blood platelets. Platelets 4:341–342PubMedCrossRef
9.
Zurück zum Zitat Higashi T, Ashida N, Takeuchi T (1997) Orientation of blood cells in static magnetic field. Physica B 237/238:616–620CrossRef Higashi T, Ashida N, Takeuchi T (1997) Orientation of blood cells in static magnetic field. Physica B 237/238:616–620CrossRef
10.
Zurück zum Zitat Jones MI, McColl IR, Grant DM et al (1999) Haemocompatibility of DLC and TiC–TiN interlayers on titanium. Diam Relat Mater 8(2–5):457–462CrossRef Jones MI, McColl IR, Grant DM et al (1999) Haemocompatibility of DLC and TiC–TiN interlayers on titanium. Diam Relat Mater 8(2–5):457–462CrossRef
11.
Zurück zum Zitat Liu JX, Yang DZ, Shi F et al (2003) Sol–gel deposited TiO2 film on NiTi surgical alloy for biocompatibility improvement. Thin Solid Film 429:225–230CrossRef Liu JX, Yang DZ, Shi F et al (2003) Sol–gel deposited TiO2 film on NiTi surgical alloy for biocompatibility improvement. Thin Solid Film 429:225–230CrossRef
12.
Zurück zum Zitat Michiardi A, Aparicio C, Planell JA et al (2006) New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res B 77(2):249–256 Michiardi A, Aparicio C, Planell JA et al (2006) New oxidation treatment of NiTi shape memory alloys to obtain Ni-free surfaces and to improve biocompatibility. J Biomed Mater Res B 77(2):249–256
13.
Zurück zum Zitat Poon RW, Yeung KW, Liu XY et al (2005) Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys. Biomaterials 26(15):2265–2272PubMedCrossRef Poon RW, Yeung KW, Liu XY et al (2005) Carbon plasma immersion ion implantation of nickel-titanium shape memory alloys. Biomaterials 26(15):2265–2272PubMedCrossRef
14.
Zurück zum Zitat Ratner BD (2007) The catastrophe revisited: blood compatibility in the 21st century. Biomaterials 28:5144–5147PubMedCrossRef Ratner BD (2007) The catastrophe revisited: blood compatibility in the 21st century. Biomaterials 28:5144–5147PubMedCrossRef
15.
Zurück zum Zitat Shabalovskaya S, Anderegg J, Humbeek JV (2008) Critical overview of nitinol surface and their modifications for medical applications. Acta Biomater 4:447–467PubMedCrossRef Shabalovskaya S, Anderegg J, Humbeek JV (2008) Critical overview of nitinol surface and their modifications for medical applications. Acta Biomater 4:447–467PubMedCrossRef
16.
Zurück zum Zitat Simon MD, Geim AK (2000) Diamagnetic levitation: flying frogs and floating magnets. J Appl Phys 87(9):6200–6204CrossRef Simon MD, Geim AK (2000) Diamagnetic levitation: flying frogs and floating magnets. J Appl Phys 87(9):6200–6204CrossRef
17.
Zurück zum Zitat Starosvetsky D, Gotman I (2001) Corrosion behavior of titanium nitride coated Ni–Ti shape memory surgical ally. Biomaterials 22:1853–1859PubMedCrossRef Starosvetsky D, Gotman I (2001) Corrosion behavior of titanium nitride coated Ni–Ti shape memory surgical ally. Biomaterials 22:1853–1859PubMedCrossRef
18.
Zurück zum Zitat Tepe G, Wendl HP, Khorchidi S, Schmehl J, Wiskirchen J, Pusich B et al (2002) Thrombogenicity of various endovascular stent types: an in vitro evaluation. J Vasc Interv 13(10):1029–1035CrossRef Tepe G, Wendl HP, Khorchidi S, Schmehl J, Wiskirchen J, Pusich B et al (2002) Thrombogenicity of various endovascular stent types: an in vitro evaluation. J Vasc Interv 13(10):1029–1035CrossRef
19.
Zurück zum Zitat Tepe G, Schmehl J, Wendl HP, Sivio S et al (2006) Reduced thrombogenicity of nitinol stents—in vitro evaluation of different surface modification and coatings. Biomaterials 27:643–650PubMedCrossRef Tepe G, Schmehl J, Wendl HP, Sivio S et al (2006) Reduced thrombogenicity of nitinol stents—in vitro evaluation of different surface modification and coatings. Biomaterials 27:643–650PubMedCrossRef
20.
Zurück zum Zitat Thierry B, Merhi Y, Bilodeau L et al (2002) Nitinol versus stainless steel: acute thrombogenicity study in an ex vivo porcine model. Biomaterials 23:2997–3005PubMedCrossRef Thierry B, Merhi Y, Bilodeau L et al (2002) Nitinol versus stainless steel: acute thrombogenicity study in an ex vivo porcine model. Biomaterials 23:2997–3005PubMedCrossRef
21.
Zurück zum Zitat Torbet J, Freyssinet JM, Hudry-Clergeon G (1981) Oriented fibrin gels formed by polymerization in strong magnetic fields. Nature 289:91–93PubMedCrossRef Torbet J, Freyssinet JM, Hudry-Clergeon G (1981) Oriented fibrin gels formed by polymerization in strong magnetic fields. Nature 289:91–93PubMedCrossRef
22.
Zurück zum Zitat Tsyganov I, Maitz MF, Wieser E et al (2003) Structure and properties of titanium oxide layers prepared by metal plasma immersion ion implantation and deposition. Surf Coat Technol 174–175(9–10):591–596CrossRef Tsyganov I, Maitz MF, Wieser E et al (2003) Structure and properties of titanium oxide layers prepared by metal plasma immersion ion implantation and deposition. Surf Coat Technol 174–175(9–10):591–596CrossRef
23.
Zurück zum Zitat Yamagishi A, Takeuchi T, Higashi T, Date M (1992) Diamagnetic orientation of blood cells in high magnetic field. Physica B 177:523–526CrossRef Yamagishi A, Takeuchi T, Higashi T, Date M (1992) Diamagnetic orientation of blood cells in high magnetic field. Physica B 177:523–526CrossRef
24.
Zurück zum Zitat Yeung KW, Poon RW, Chu PK et al (2007) Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. J Biomed Mater Res A 82(2):403–414PubMed Yeung KW, Poon RW, Chu PK et al (2007) Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials. J Biomed Mater Res A 82(2):403–414PubMed
Metadaten
Titel
Effects of micro-magnetic field at the surface of 316L and NiTi alloy on blood compatibility
verfasst von
Qiang Liu
Xiao Nong Cheng
Huang Xia Fei
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 3/2011
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-010-0685-z

Weitere Artikel der Ausgabe 3/2011

Medical & Biological Engineering & Computing 3/2011 Zur Ausgabe