Skip to main content
Erschienen in: Medical & Biological Engineering & Computing 3/2017

18.05.2016 | Original Article

Development of a compact continuum tubular robotic system for nasopharyngeal biopsy

verfasst von: Liao Wu, Shuang Song, Keyu Wu, Chwee Ming Lim, Hongliang Ren

Erschienen in: Medical & Biological Engineering & Computing | Ausgabe 3/2017

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Traditional posterior nasopharyngeal biopsy using a flexible nasal endoscope has the risks of abrasion and injury to the nasal mucosa and thus causing trauma to the patient. Recently, a new class of robots known as continuum tubular robots (CTRs) provide a novel solution to the challenge with miniaturized size, curvilinear maneuverability, and capability of avoiding collision within the nasal environment. This paper presents a compact CTR which is 35 cm in total length, 10 cm in diameter, 2.15 kg in weight, and easy to be integrated with a robotic arm to perform more complicated operations. Structural design, end-effector design, and workspace analysis are described in detail. In addition, teleoperation of the CTR using a haptic input device is developed for position control in 3D space. Moreover, by integrating the robot with three electromagnetic tracking sensors, a navigation system together with a shape reconstruction algorithm is developed. Comprehensive experiments are conducted to test the functionality of the proposed prototype; experiment results show that under teleoperation, the system has an accuracy of 2.20 mm in following a linear path, an accuracy of 2.01 mm in following a circular path, and a latency time of 0.1 s. It is also found that the proposed shape reconstruction algorithm has a mean error of around 1 mm along the length of the tubes. Besides, the feasibility and effectiveness of the proposed robotic system being applied to posterior nasopharyngeal biopsy are demonstrated by a cadaver experiment. The proposed robotic system holds promise to enhance clinical operation in transnasal procedures.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Burgner J, Swaney PJ, Lathrop RA, Weaver KD, Webster RJ (2013) Debulking from within: a robotic steerable cannula for intracerebral hemorrhage evacuation. IEEE Trans Biomed Eng 60(9):2567–2575CrossRefPubMed Burgner J, Swaney PJ, Lathrop RA, Weaver KD, Webster RJ (2013) Debulking from within: a robotic steerable cannula for intracerebral hemorrhage evacuation. IEEE Trans Biomed Eng 60(9):2567–2575CrossRefPubMed
2.
Zurück zum Zitat Burgner J, Rucker DC, Gilbert HB, Swaney PJ, Russell PT, Weaver KD, Webster RJ (2014) A telerobotic system for transnasal surgery. IEEE/ASME Trans Mechatron 19(3):996–1006CrossRef Burgner J, Rucker DC, Gilbert HB, Swaney PJ, Russell PT, Weaver KD, Webster RJ (2014) A telerobotic system for transnasal surgery. IEEE/ASME Trans Mechatron 19(3):996–1006CrossRef
3.
Zurück zum Zitat Butler EJ, Hammond-Oakley R, Chawarski S, Gosline AH, Codd P, Anor T, Madsen JR, Dupont PE, Lock J (2012) Robotic neuro-emdoscope with concentric tube augmentation. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2941–2946 Butler EJ, Hammond-Oakley R, Chawarski S, Gosline AH, Codd P, Anor T, Madsen JR, Dupont PE, Lock J (2012) Robotic neuro-emdoscope with concentric tube augmentation. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2941–2946
5.
Zurück zum Zitat Ebert LC, Ptacek W, Naether S, Fürst M, Ross S, Buck U, Weber S, Thali M (2010) Virtobot a multi-functional robotic system for 3d surface scanning and automatic post mortem biopsy. Int J Med Robot Comput Assist Surg 6(1):18–27 Ebert LC, Ptacek W, Naether S, Fürst M, Ross S, Buck U, Weber S, Thali M (2010) Virtobot a multi-functional robotic system for 3d surface scanning and automatic post mortem biopsy. Int J Med Robot Comput Assist Surg 6(1):18–27
6.
Zurück zum Zitat Gosline AH, Vasilyev NV, Butler EJ, Folk C, Cohen A, Chen R, Lang N, Del Nido PJ, Dupont PE (2012) Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools. Int J Robot Res 31(9):1081–1093CrossRef Gosline AH, Vasilyev NV, Butler EJ, Folk C, Cohen A, Chen R, Lang N, Del Nido PJ, Dupont PE (2012) Percutaneous intracardiac beating-heart surgery using metal MEMS tissue approximation tools. Int J Robot Res 31(9):1081–1093CrossRef
7.
Zurück zum Zitat Guler O, Yaniv Z (2012) Image-guided navigation: a cost effective practical introduction using the image-guided surgery toolkit (IGSTK). In: International conference of the IEEE engineering in medicine and biology society (EMBC), pp 6056–6059 Guler O, Yaniv Z (2012) Image-guided navigation: a cost effective practical introduction using the image-guided surgery toolkit (IGSTK). In: International conference of the IEEE engineering in medicine and biology society (EMBC), pp 6056–6059
8.
Zurück zum Zitat Hendrick RJ, Mitchell CR, Herrell SD, Webster RJ (2015) Hand-held transendoscopic robotic manipulators: a transurethral laser prostate surgery case study. Int J Robot Res 34(13):1559–1572CrossRef Hendrick RJ, Mitchell CR, Herrell SD, Webster RJ (2015) Hand-held transendoscopic robotic manipulators: a transurethral laser prostate surgery case study. Int J Robot Res 34(13):1559–1572CrossRef
9.
Zurück zum Zitat Horn BK (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(4):629–642CrossRef Horn BK (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(4):629–642CrossRef
10.
Zurück zum Zitat Kim B, Ha J, Park F, Dupont PE (2014) Optimizing curvature sensor placement for fast, accurate shape sensing of continuum robots. In: 2014 IEEE international conference on robotics and automation (ICRA), pp 5374–5379 Kim B, Ha J, Park F, Dupont PE (2014) Optimizing curvature sensor placement for fast, accurate shape sensing of continuum robots. In: 2014 IEEE international conference on robotics and automation (ICRA), pp 5374–5379
11.
Zurück zum Zitat King AD, Vlantis AC, Bhatia KS, Zee BC, Woo JK, Tse GM, Chan AT, Ahuja AT (2011) Primary nasopharyngeal carcinoma: diagnostic accuracy of MR imaging versus that of endoscopy and endoscopic biopsy. Radiology 258(2):531–537CrossRefPubMed King AD, Vlantis AC, Bhatia KS, Zee BC, Woo JK, Tse GM, Chan AT, Ahuja AT (2011) Primary nasopharyngeal carcinoma: diagnostic accuracy of MR imaging versus that of endoscopy and endoscopic biopsy. Radiology 258(2):531–537CrossRefPubMed
12.
Zurück zum Zitat Lee H, Kim J (2014) Estimation of flexible needle deflection in layered soft tissues with different elastic moduli. Med Biol Eng Comput 52(9):729–740CrossRefPubMed Lee H, Kim J (2014) Estimation of flexible needle deflection in layered soft tissues with different elastic moduli. Med Biol Eng Comput 52(9):729–740CrossRefPubMed
13.
Zurück zum Zitat Lozano R, Naghavi M, Foreman K, Lim S, Shibuya K, Aboyans V, Abraham J, Adair T, Aggarwal R, Ahn SY et al (2013) Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of disease study 2010. The Lancet 380(9859):2095–2128CrossRef Lozano R, Naghavi M, Foreman K, Lim S, Shibuya K, Aboyans V, Abraham J, Adair T, Aggarwal R, Ahn SY et al (2013) Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010: a systematic analysis for the global burden of disease study 2010. The Lancet 380(9859):2095–2128CrossRef
14.
Zurück zum Zitat Midwinter K, Ahmed A, Willatt D (2001) A randomised trial of flexible versus rigid nasendoscopy in outpatient sinonasal examination. Clin Otolaryngol Allied Sci 26(4):281–283CrossRefPubMed Midwinter K, Ahmed A, Willatt D (2001) A randomised trial of flexible versus rigid nasendoscopy in outpatient sinonasal examination. Clin Otolaryngol Allied Sci 26(4):281–283CrossRefPubMed
16.
Zurück zum Zitat Park YL, Elayaperumal S, Daniel B, Ryu SC, Shin M, Savall J, Black RJ, Moslehi B, Cutkosky MR (2010) Real-time estimation of 3-D needle shape and deflection for MRI-guided interventions. IEEE/ASME Trans Mechatron 15(6):906–915 Park YL, Elayaperumal S, Daniel B, Ryu SC, Shin M, Savall J, Black RJ, Moslehi B, Cutkosky MR (2010) Real-time estimation of 3-D needle shape and deflection for MRI-guided interventions. IEEE/ASME Trans Mechatron 15(6):906–915
17.
Zurück zum Zitat Phadke R, Saha M, Prasad K, Goyal D (2001) Transnasal access for sampling a skull base lesion. Am J Neuroradiol 22(4):745–747PubMed Phadke R, Saha M, Prasad K, Goyal D (2001) Transnasal access for sampling a skull base lesion. Am J Neuroradiol 22(4):745–747PubMed
18.
Zurück zum Zitat Ren H, Dupont PE (2011) Tubular structure enhancement for surgical instrument detection in 3D ultrasound. In: 2011 annual international conference of the IEEE in engineering in medicine and biology society, EMBC, pp 7203–7206. IEEE Ren H, Dupont PE (2011) Tubular structure enhancement for surgical instrument detection in 3D ultrasound. In: 2011 annual international conference of the IEEE in engineering in medicine and biology society, EMBC, pp 7203–7206. IEEE
19.
Zurück zum Zitat Ren H, Dupont PE (2012) Tubular enhanced geodesic active contours for continuum robot detection using 3D ultrasound. In: IEEE international conference on robotics and automation (ICRA), pp 2907–2912. IEEE Ren H, Dupont PE (2012) Tubular enhanced geodesic active contours for continuum robot detection using 3D ultrasound. In: IEEE international conference on robotics and automation (ICRA), pp 2907–2912. IEEE
20.
Zurück zum Zitat Rucker DC, Webster RJ, Chirikjian GS, Cowan NJ (2010) Equilibrium conformations of concentric-tube continuum robots. Int J Robot Res 29(10):1263–1280CrossRef Rucker DC, Webster RJ, Chirikjian GS, Cowan NJ (2010) Equilibrium conformations of concentric-tube continuum robots. Int J Robot Res 29(10):1263–1280CrossRef
21.
Zurück zum Zitat Sears P, Dupont P (2006) A steerable needle technology using curved concentric tubes. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2850–2856 Sears P, Dupont P (2006) A steerable needle technology using curved concentric tubes. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2850–2856
22.
Zurück zum Zitat Sears P, Dupont PE (2007) Inverse kinematics of concentric tube steerable needles. In: IEEE international conference on robotics and automation (ICRA), pp 1887–1892 Sears P, Dupont PE (2007) Inverse kinematics of concentric tube steerable needles. In: IEEE international conference on robotics and automation (ICRA), pp 1887–1892
23.
Zurück zum Zitat Selig J (2005) Geometric fundamentals of robotics (monographs in computer science series). Springer, New York Selig J (2005) Geometric fundamentals of robotics (monographs in computer science series). Springer, New York
24.
Zurück zum Zitat Song S, Li Z, Yu H, Ren H (2015) Electromagnetic positioning for tip tracking and shape sensing of flexible robots. IEEE Sens J 15(8):4565–4575CrossRef Song S, Li Z, Yu H, Ren H (2015) Electromagnetic positioning for tip tracking and shape sensing of flexible robots. IEEE Sens J 15(8):4565–4575CrossRef
25.
Zurück zum Zitat Song S, Li Z, Yu H, Ren H (2015) Shape reconstruction for wire-driven flexible robots based on Bézier curve and electromagnetic positioning. Mechatronics 29:28–35CrossRef Song S, Li Z, Yu H, Ren H (2015) Shape reconstruction for wire-driven flexible robots based on Bézier curve and electromagnetic positioning. Mechatronics 29:28–35CrossRef
26.
Zurück zum Zitat Su H, Cardona DC, Shang W, Camilo A, Cole GA, Rucker DC, Webster RJ, Fischer GS (2012) A MRI-guided concentric tube continuum robot with piezoelectric actuation: a feasibility study. In: IEEE international conference on robotics and automation (ICRA), pp 1939–1945 Su H, Cardona DC, Shang W, Camilo A, Cole GA, Rucker DC, Webster RJ, Fischer GS (2012) A MRI-guided concentric tube continuum robot with piezoelectric actuation: a feasibility study. In: IEEE international conference on robotics and automation (ICRA), pp 1939–1945
27.
Zurück zum Zitat Subramaniam RP, Richardson RB, Morgan KT, Kimbell JS, Guilmette RA (1998) Computational fluid dynamics simulations of inspiratory airflow in the human nose and nasopharynx. Inhal Toxicol 10(2):91–120CrossRef Subramaniam RP, Richardson RB, Morgan KT, Kimbell JS, Guilmette RA (1998) Computational fluid dynamics simulations of inspiratory airflow in the human nose and nasopharynx. Inhal Toxicol 10(2):91–120CrossRef
28.
Zurück zum Zitat Torabi M, Gupta R, Walsh CJ (2014) Compact robotically steerable image-guided instrument for multi-adjacent-point (MAP) targeting. IEEE Trans Robot 30(4):802–815CrossRef Torabi M, Gupta R, Walsh CJ (2014) Compact robotically steerable image-guided instrument for multi-adjacent-point (MAP) targeting. IEEE Trans Robot 30(4):802–815CrossRef
29.
Zurück zum Zitat Wampler CW (1986) Manipulator inverse kinematic solutions based on vector formulations and damped least-squares methods. IEEE Trans Syst Man Cybern 16(1):93–101CrossRef Wampler CW (1986) Manipulator inverse kinematic solutions based on vector formulations and damped least-squares methods. IEEE Trans Syst Man Cybern 16(1):93–101CrossRef
30.
Zurück zum Zitat Webster R, Okamura AM, Cowan NJ (2006) Toward active cannulas: miniature snake-like surgical robots. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2857–2863 Webster R, Okamura AM, Cowan NJ (2006) Toward active cannulas: miniature snake-like surgical robots. In: IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 2857–2863
31.
Zurück zum Zitat Wei WI, Sham JS (2005) Nasopharyngeal carcinoma. The Lancet 365(9476):2041–2054CrossRef Wei WI, Sham JS (2005) Nasopharyngeal carcinoma. The Lancet 365(9476):2041–2054CrossRef
32.
Zurück zum Zitat Wirz R, Torres LG, Swaney PJ, Gilbert H, Alterovitz R, Webster RJ III, Weaver KD, Russell PT III (2015) An experimental feasibility study on robotic endonasal telesurgery. Neurosurgery 76(4):479–484CrossRefPubMedPubMedCentral Wirz R, Torres LG, Swaney PJ, Gilbert H, Alterovitz R, Webster RJ III, Weaver KD, Russell PT III (2015) An experimental feasibility study on robotic endonasal telesurgery. Neurosurgery 76(4):479–484CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Wu K, Wu L, Lim CM, Ren H (2014) An image based targeting method to guide a curvilinear concentric tube robot. In: IEEE international conference on robotics and biomimetics (ROBIO), pp 386–391 Wu K, Wu L, Lim CM, Ren H (2014) An image based targeting method to guide a curvilinear concentric tube robot. In: IEEE international conference on robotics and biomimetics (ROBIO), pp 386–391
34.
Zurück zum Zitat Wu L, Yang X, Chen K, Ren H (2014) A minimal POE-based model for robotic kinematic calibration with only position measurements. IEEE Trans Autom Sci Eng 12(2):758–763CrossRef Wu L, Yang X, Chen K, Ren H (2014) A minimal POE-based model for robotic kinematic calibration with only position measurements. IEEE Trans Autom Sci Eng 12(2):758–763CrossRef
35.
Zurück zum Zitat Wu K, Wu L, Lim CM, Ren H (2015) Model-free image guidance for intelligent tubular robots with pre-clinical feasibility study: towards minimally invasive trans-orifice surgery. In: IEEE international conference on information and automation (ICIA), pp 749–754 Wu K, Wu L, Lim CM, Ren H (2015) Model-free image guidance for intelligent tubular robots with pre-clinical feasibility study: towards minimally invasive trans-orifice surgery. In: IEEE international conference on information and automation (ICIA), pp 749–754
36.
Zurück zum Zitat Wu K, Wu L, Ren H (2015) Motion planning of continuum tubular robots based on features extracted from statistical atlas. In: IEEE international conference on intelligent robots and systems (IROS), pp 5512–5517 Wu K, Wu L, Ren H (2015) Motion planning of continuum tubular robots based on features extracted from statistical atlas. In: IEEE international conference on intelligent robots and systems (IROS), pp 5512–5517
37.
Zurück zum Zitat Wu L, Tan BLW, Ren H (2015) Prototype development of a hand-held robotic light pipe for intraocular procedures. In: 2015 IEEE international conference on robotics and biomimetics (ROBIO), pp 368–373 Wu L, Tan BLW, Ren H (2015) Prototype development of a hand-held robotic light pipe for intraocular procedures. In: 2015 IEEE international conference on robotics and biomimetics (ROBIO), pp 368–373
38.
Zurück zum Zitat Yang X, Wu L, Li J, Chen K (2014) A minimal kinematic model for serial robot calibration using POE formula. Robot Comput Integr Manuf 30(3):326–334CrossRef Yang X, Wu L, Li J, Chen K (2014) A minimal kinematic model for serial robot calibration using POE formula. Robot Comput Integr Manuf 30(3):326–334CrossRef
39.
Zurück zum Zitat Yoon HS, Oh SM, Jeong JH, Lee SH, Tae K, Koh KC, Yi BJ (2011) Active bending endoscope robot system for navigation through sinus area. In: 2011 IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 967–972 Yoon HS, Oh SM, Jeong JH, Lee SH, Tae K, Koh KC, Yi BJ (2011) Active bending endoscope robot system for navigation through sinus area. In: 2011 IEEE/RSJ international conference on intelligent robots and systems (IROS), pp 967–972
40.
Zurück zum Zitat Yu H, Wu L, Wu K, Ren H (2016) Development of a multi-channel concentric tube robotic system with active vision for transnasal nasopharyngeal carcinoma procedures. IEEE Robot Autom Lett 1(2):1172–1178CrossRef Yu H, Wu L, Wu K, Ren H (2016) Development of a multi-channel concentric tube robotic system with active vision for transnasal nasopharyngeal carcinoma procedures. IEEE Robot Autom Lett 1(2):1172–1178CrossRef
Metadaten
Titel
Development of a compact continuum tubular robotic system for nasopharyngeal biopsy
verfasst von
Liao Wu
Shuang Song
Keyu Wu
Chwee Ming Lim
Hongliang Ren
Publikationsdatum
18.05.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Medical & Biological Engineering & Computing / Ausgabe 3/2017
Print ISSN: 0140-0118
Elektronische ISSN: 1741-0444
DOI
https://doi.org/10.1007/s11517-016-1514-9

Weitere Artikel der Ausgabe 3/2017

Medical & Biological Engineering & Computing 3/2017 Zur Ausgabe