Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 4/2014

01.07.2014 | Original Article

Simultaneous extraction of carotid artery intima-media interfaces in ultrasound images: assessment of wall thickness temporal variation during the cardiac cycle

verfasst von: Guillaume Zahnd, Maciej Orkisz, André Sérusclat, Philippe Moulin, Didier Vray

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 4/2014

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Objectives

   The aim of this work is to present and evaluate a novel segmentation method for localizing the contours of the intima-media complex in the carotid artery wall through longitudinal ultrasound B-mode imaging. The method is used to investigate the association between atherosclerosis risk factors and the cyclic variation of the intima-media thickness during the heart beat.

Methods

   The framework introduced is based on two main features. The first is a simultaneous extraction of both the lumen-intima and the media-adventitia interfaces, using the combination of an original shape-adapted filter bank and a specific dynamic programming scheme. The second is an innovative spatial transformation that eases the extraction of skewed and curved contours, and exploits the result from the previous image as a priori information, when processing the current image. The intima-media thickness is automatically derived from the estimated contours for each time step during the cardiac cycle. Our method was evaluated in vivo on 57 healthy volunteers and 25 patients at high cardiovascular risk. Reference contours were generated for each subject by averaging the tracings performed by three experienced observers.

Results

   Segmentation errors were \(29 \pm 27\,\upmu \hbox {m}\) for the lumen-intima interface, \(42 \pm 38\,\upmu \hbox {m}\) for the media-adventitia interface, and \(22 \pm 16\,\upmu \hbox {m}\) for the intima-media thickness. This uncertainty was similar to inter- and intra-observer variability. Furthermore, the amplitude of the temporal variation in thickness of the intima-media layers during the cardiac cycle was significantly higher in at-risk patients compared to healthy volunteers \((79 \pm 36\) vs. \(64 \pm 26\,\upmu \hbox {m},\, p=0.032)\).

Conclusion

   The method proposed may provide a relevant diagnostic aid for atherosclerosis screening in clinical studies.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Fußnoten
1
We drop \(n\) to simplify the notations, when it is not confusing, since all the subsequent steps detailed in this section are performed on the same time-point \(n\).
 
Literatur
1.
Zurück zum Zitat Acharya UR, Vinitha Sree S, Muthu Rama Krishnan M, Molinari F, Saba L, Ho SYS, Ahuja AT, Ho SC, Nicolaides A, Suri JS (2012) Atherosclerotic risk stratification strategy for carotid arteries using texture-based features. Ultrasound Med Biol 38(6):899–915PubMedCrossRef Acharya UR, Vinitha Sree S, Muthu Rama Krishnan M, Molinari F, Saba L, Ho SYS, Ahuja AT, Ho SC, Nicolaides A, Suri JS (2012) Atherosclerotic risk stratification strategy for carotid arteries using texture-based features. Ultrasound Med Biol 38(6):899–915PubMedCrossRef
2.
Zurück zum Zitat Baldassarre D, Amato M, Bondioli A, Sirtori CR, Tremoli E (2000) Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors. Stroke 31(10):2426–2430PubMedCrossRef Baldassarre D, Amato M, Bondioli A, Sirtori CR, Tremoli E (2000) Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors. Stroke 31(10):2426–2430PubMedCrossRef
3.
Zurück zum Zitat Bellman R (1966) Dynamic programming. Science 153(3731): 34–37 Bellman R (1966) Dynamic programming. Science 153(3731): 34–37
4.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327(8476):307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327(8476):307–310CrossRef
5.
Zurück zum Zitat Bots ML, Hoes AW, Koudstaal PJ, Hofman A, Grobbee DE (1997) Common carotid intima-media thickness and risk of stroke and myocardial infarction: the Rotterdam study. Circulation 96(5):1432–1437PubMedCrossRef Bots ML, Hoes AW, Koudstaal PJ, Hofman A, Grobbee DE (1997) Common carotid intima-media thickness and risk of stroke and myocardial infarction: the Rotterdam study. Circulation 96(5):1432–1437PubMedCrossRef
6.
Zurück zum Zitat Boutouyrie P, Germain DP, Tropeano AI, Laloux B, Carenzi F, Zidi M, Jeunemaitre X, Laurent S (2001) Compressibility of the carotid artery in patients with pseudoxanthoma elasticum. Hypertension 38(5):1181–1184PubMedCrossRef Boutouyrie P, Germain DP, Tropeano AI, Laloux B, Carenzi F, Zidi M, Jeunemaitre X, Laurent S (2001) Compressibility of the carotid artery in patients with pseudoxanthoma elasticum. Hypertension 38(5):1181–1184PubMedCrossRef
7.
Zurück zum Zitat Burke GL, Evans G, Riley WA, Sharrett AR, Howard G, Barnes RW, Rosamond W, Crow RS, Rautaharju PM, Heiss G (1995) Arterial wall thickness is associated with prevalent cardiovascular disease in middle-aged adults: the Atherosclerosis Risk in Communities (ARIC) study. Stroke 26(3):386–391PubMedCrossRef Burke GL, Evans G, Riley WA, Sharrett AR, Howard G, Barnes RW, Rosamond W, Crow RS, Rautaharju PM, Heiss G (1995) Arterial wall thickness is associated with prevalent cardiovascular disease in middle-aged adults: the Atherosclerosis Risk in Communities (ARIC) study. Stroke 26(3):386–391PubMedCrossRef
8.
Zurück zum Zitat Celermajer DS, Sorensen KE, Gooch VM, Sullivan ID, Lloyd JK, Deanfield JE, Spiegelhalter DJ (1992) Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis. Lancet 340(8828):1111–1115PubMedCrossRef Celermajer DS, Sorensen KE, Gooch VM, Sullivan ID, Lloyd JK, Deanfield JE, Spiegelhalter DJ (1992) Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis. Lancet 340(8828):1111–1115PubMedCrossRef
9.
Zurück zum Zitat Cheng DC, Jiang X (2008) Detections of arterial wall in sonographic artery images using dual dynamic programming. IEEE Trans Inf Technol Biomed 12(6):792–799PubMedCrossRef Cheng DC, Jiang X (2008) Detections of arterial wall in sonographic artery images using dual dynamic programming. IEEE Trans Inf Technol Biomed 12(6):792–799PubMedCrossRef
10.
Zurück zum Zitat Cheng DC, Schmidt-Trucksäss A, Cheng K, Burkhardt H (2002) Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images. Comput Methods Program Biomed 67(1):27–37CrossRef Cheng DC, Schmidt-Trucksäss A, Cheng K, Burkhardt H (2002) Using snakes to detect the intimal and adventitial layers of the common carotid artery wall in sonographic images. Comput Methods Program Biomed 67(1):27–37CrossRef
11.
Zurück zum Zitat Cinthio M, Jansson T, Ahlgren ÅR, Lindström K, Persson HW (2010) A method for arterial diameter change measurements using ultrasonic B-mode data. Ultrasound Med Biol 36(9):1504–1512PubMedCrossRef Cinthio M, Jansson T, Ahlgren ÅR, Lindström K, Persson HW (2010) A method for arterial diameter change measurements using ultrasonic B-mode data. Ultrasound Med Biol 36(9):1504–1512PubMedCrossRef
12.
Zurück zum Zitat Cinthio M, Jansson T, Persson HW, Lindstrom K, Ahlgren ÅR (2005) New non-invasive method for intima-media thickness and intima-media compression measurements. In: IEEE international ultrasonics symposium, vol 1, Rotterdam, Netherlands, pp 385–388 Cinthio M, Jansson T, Persson HW, Lindstrom K, Ahlgren ÅR (2005) New non-invasive method for intima-media thickness and intima-media compression measurements. In: IEEE international ultrasonics symposium, vol 1, Rotterdam, Netherlands, pp 385–388
13.
Zurück zum Zitat Cohen L (2006) Minimal paths and fast marching methods for image analysis. In: Paragios N, Chen Y, Faugeras O (eds) Handbook of mathematical models in computer vision. Springer, US, pp 97–111 Cohen L (2006) Minimal paths and fast marching methods for image analysis. In: Paragios N, Chen Y, Faugeras O (eds) Handbook of mathematical models in computer vision. Springer, US, pp 97–111
14.
Zurück zum Zitat Delsanto S, Molinari F, Giustetto P, Liboni W, Badalamenti S, Suri JS (2007) Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images. IEEE Trans Instrum Meas 56(4):1265–1274CrossRef Delsanto S, Molinari F, Giustetto P, Liboni W, Badalamenti S, Suri JS (2007) Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images. IEEE Trans Instrum Meas 56(4):1265–1274CrossRef
15.
Zurück zum Zitat Destrempes F, Meunier J, Giroux MF, Soulez G, Cloutier G (2009) Segmentation in ultrasonic B-mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization. IEEE Trans Med Imaging 28(2):215–229PubMedCrossRef Destrempes F, Meunier J, Giroux MF, Soulez G, Cloutier G (2009) Segmentation in ultrasonic B-mode images of healthy carotid arteries using mixtures of Nakagami distributions and stochastic optimization. IEEE Trans Med Imaging 28(2):215–229PubMedCrossRef
16.
Zurück zum Zitat Faita F, Gemignani V, Bianchini E, Giannarelli C, Ghiadoni L, Demi M (2008) Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator. J Ultrasound Med 27(9):1353–1361PubMed Faita F, Gemignani V, Bianchini E, Giannarelli C, Ghiadoni L, Demi M (2008) Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator. J Ultrasound Med 27(9):1353–1361PubMed
17.
Zurück zum Zitat Ford ES (2005) Risks for all-cause mortality, cardiovascular disease, and diabetes associated with the metabolic syndrome: a summary of the evidence. Diabetes Care 28(7):1769–1778PubMedCrossRef Ford ES (2005) Risks for all-cause mortality, cardiovascular disease, and diabetes associated with the metabolic syndrome: a summary of the evidence. Diabetes Care 28(7):1769–1778PubMedCrossRef
18.
Zurück zum Zitat Ford ES, Ajani UA, Croft JB, Critchley JA, Labarthe DR, Kottke TE, Giles WH, Capewell S (2007) Explaining the decrease in US deaths from coronary disease, 1980–2000. N Engl J Med 356(23):2388–2398PubMedCrossRef Ford ES, Ajani UA, Croft JB, Critchley JA, Labarthe DR, Kottke TE, Giles WH, Capewell S (2007) Explaining the decrease in US deaths from coronary disease, 1980–2000. N Engl J Med 356(23):2388–2398PubMedCrossRef
19.
Zurück zum Zitat Gemignani V, Faita F, Ghiadoni L, Poggianti E, Demi M (2007) A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images. IEEE Trans Med Imaging 26(3):393–404PubMedCrossRef Gemignani V, Faita F, Ghiadoni L, Poggianti E, Demi M (2007) A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images. IEEE Trans Med Imaging 26(3):393–404PubMedCrossRef
20.
Zurück zum Zitat Golemati S, Gastounioti A, Nikita KS (2013) Toward novel noninvasive and low-cost markers for predicting strokes in asymptomatic carotid atherosclerosis: the role of ultrasound image analysis. IEEE Trans Biomed Eng 60(3):653CrossRef Golemati S, Gastounioti A, Nikita KS (2013) Toward novel noninvasive and low-cost markers for predicting strokes in asymptomatic carotid atherosclerosis: the role of ultrasound image analysis. IEEE Trans Biomed Eng 60(3):653CrossRef
21.
Zurück zum Zitat Golemati S, Stoitsis J, Sifakis EG, Balkizas T, Nikita KS (2007) Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery. Ultrasound Med Biol 33(12):1918–1932PubMedCrossRef Golemati S, Stoitsis J, Sifakis EG, Balkizas T, Nikita KS (2007) Using the Hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery. Ultrasound Med Biol 33(12):1918–1932PubMedCrossRef
22.
Zurück zum Zitat Haller C, Schulz J, Schmidt-Trucksäss A, Burkardt H, Schmitz D, Dickhuth HH, Sandrock M (2007) Sequential based analysis of intima-media thickness (IMT) in common carotid artery studies. Atherosclerosis 195(2):e203–e209PubMedCrossRef Haller C, Schulz J, Schmidt-Trucksäss A, Burkardt H, Schmitz D, Dickhuth HH, Sandrock M (2007) Sequential based analysis of intima-media thickness (IMT) in common carotid artery studies. Atherosclerosis 195(2):e203–e209PubMedCrossRef
23.
Zurück zum Zitat Ilea DE, Duffy C, Kavanagh L, Stanton A, Whelan PF (2013) Fully automated segmentation and tracking of the intima media thickness in ultrasound video sequences of the common carotid artery. IEEE Trans Ultrason Ferroelectr Freq Control 60(1):158–177PubMedCrossRef Ilea DE, Duffy C, Kavanagh L, Stanton A, Whelan PF (2013) Fully automated segmentation and tracking of the intima media thickness in ultrasound video sequences of the common carotid artery. IEEE Trans Ultrason Ferroelectr Freq Control 60(1):158–177PubMedCrossRef
24.
Zurück zum Zitat Laurent S, Boutouyrie P, Asmar R, Gautier I, Laloux B, Guize L, Ducimetiere P, Benetos A (2001) Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients. Hypertension 37(5):1236–1241PubMedCrossRef Laurent S, Boutouyrie P, Asmar R, Gautier I, Laloux B, Guize L, Ducimetiere P, Benetos A (2001) Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients. Hypertension 37(5):1236–1241PubMedCrossRef
25.
Zurück zum Zitat Lee YB, Choi YJ, Kim MH (2010) Boundary detection in carotid ultrasound images using dynamic programming and a directional Haar-like filter. Comput Biol Med 40(8):687–697PubMedCrossRef Lee YB, Choi YJ, Kim MH (2010) Boundary detection in carotid ultrasound images using dynamic programming and a directional Haar-like filter. Comput Biol Med 40(8):687–697PubMedCrossRef
26.
Zurück zum Zitat Liang Q, Wendelhag I, Wikstrand J, Gustavsson T (2000) A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images. IEEE Trans Med Imaging 19(2):127–142PubMedCrossRef Liang Q, Wendelhag I, Wikstrand J, Gustavsson T (2000) A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images. IEEE Trans Med Imaging 19(2):127–142PubMedCrossRef
27.
Zurück zum Zitat Loizou CP, Pattichis CS, Pantziaris M, Tyllis T, Nicolaides A (2007) Snakes based segmentation of the common carotid artery intima media. Med Biol Eng Comput 45(1):35–49PubMedCrossRef Loizou CP, Pattichis CS, Pantziaris M, Tyllis T, Nicolaides A (2007) Snakes based segmentation of the common carotid artery intima media. Med Biol Eng Comput 45(1):35–49PubMedCrossRef
28.
Zurück zum Zitat Lorenz MW, Markus HS, Bots ML, Rosvall M, Sitzer M (2007) Prediction of clinical cardiovascular events with carotid intima-media thickness: a systematic review and meta-analysis. Circulation 115(4):459–467PubMedCrossRef Lorenz MW, Markus HS, Bots ML, Rosvall M, Sitzer M (2007) Prediction of clinical cardiovascular events with carotid intima-media thickness: a systematic review and meta-analysis. Circulation 115(4):459–467PubMedCrossRef
29.
Zurück zum Zitat Meinders JM, Kornet L, Hoeks APG (2003) Assessment of spatial inhomogeneities in intima media thickness along an arterial segment using its dynamic behavior. Am J Physiol-Heart Circ Physiol 285(1):H384–H391PubMed Meinders JM, Kornet L, Hoeks APG (2003) Assessment of spatial inhomogeneities in intima media thickness along an arterial segment using its dynamic behavior. Am J Physiol-Heart Circ Physiol 285(1):H384–H391PubMed
30.
Zurück zum Zitat Metz CT, Klein S, Schaap M, van Walsum T, Niessen WJ (2011) Nonrigid registration of dynamic medical imaging data using nD+t B-splines and a groupwise optimization approach. Med Image Anal 15(2):238–249PubMedCrossRef Metz CT, Klein S, Schaap M, van Walsum T, Niessen WJ (2011) Nonrigid registration of dynamic medical imaging data using nD+t B-splines and a groupwise optimization approach. Med Image Anal 15(2):238–249PubMedCrossRef
31.
Zurück zum Zitat Molinari F, Liboni W, Giustetto P, Badalamenti S, Suri JS (2009) Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. J Mech Med Biol 9(04):481–505CrossRef Molinari F, Liboni W, Giustetto P, Badalamenti S, Suri JS (2009) Automatic computer-based tracings (ACT) in longitudinal 2-D ultrasound images using different scanners. J Mech Med Biol 9(04):481–505CrossRef
32.
Zurück zum Zitat Molinari F, Zeng G, Suri JS (2010) A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound. Comput Methods Program Biomed 100(3):201–221CrossRef Molinari F, Zeng G, Suri JS (2010) A state of the art review on intima-media thickness (IMT) measurement and wall segmentation techniques for carotid ultrasound. Comput Methods Program Biomed 100(3):201–221CrossRef
33.
Zurück zum Zitat Molinari F, Zeng G, Suri JS (2011) Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images. Med Biol Eng Comput 49(8):177–192CrossRef Molinari F, Zeng G, Suri JS (2011) Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images. Med Biol Eng Comput 49(8):177–192CrossRef
34.
Zurück zum Zitat Nilsson T, Ahlgren ÅR, Jansson T, Persson HW, Lindström K, Nilsson J, Cinthio M (2011) A method for measuring the variation of intima-media thickness during the entire cardiac cycle using B-mode images. In: IEEE international ultrasonics symposium, Orlando, FL, pp 2126–2129 Nilsson T, Ahlgren ÅR, Jansson T, Persson HW, Lindström K, Nilsson J, Cinthio M (2011) A method for measuring the variation of intima-media thickness during the entire cardiac cycle using B-mode images. In: IEEE international ultrasonics symposium, Orlando, FL, pp 2126–2129
35.
Zurück zum Zitat O’Leary DH, Polak JF, Kronmal RA, Manolio TA, Burke GL, Wolfson SKJ (1999) Carotid-artery intima and media thickness as a risk factor for myocardial infarction and stroke in older adults. N Engl J Med 340(1):14–22PubMedCrossRef O’Leary DH, Polak JF, Kronmal RA, Manolio TA, Burke GL, Wolfson SKJ (1999) Carotid-artery intima and media thickness as a risk factor for myocardial infarction and stroke in older adults. N Engl J Med 340(1):14–22PubMedCrossRef
36.
Zurück zum Zitat Pannier B, Guerin AP, Marchais SJ, Metivier F, Safar ME, London GM (2000) Postischemic vasodilation, endothelial activation, and cardiovascular remodeling in end-stage renal disease. Kidney Int 57(3):1091–1099PubMedCrossRef Pannier B, Guerin AP, Marchais SJ, Metivier F, Safar ME, London GM (2000) Postischemic vasodilation, endothelial activation, and cardiovascular remodeling in end-stage renal disease. Kidney Int 57(3):1091–1099PubMedCrossRef
37.
Zurück zum Zitat Polak JF, Johnson C, Harrington A, Wong Q, O’Leary DH, Burke G, Yanez ND: Changes in carotid intima-media thickness during the cardiac cycle: the multi-ethnic study of atherosclerosis. J Am Heart Assoc 1(4) (2012). doi:10.1161/JAHA.112.001420 Polak JF, Johnson C, Harrington A, Wong Q, O’Leary DH, Burke G, Yanez ND: Changes in carotid intima-media thickness during the cardiac cycle: the multi-ethnic study of atherosclerosis. J Am Heart Assoc 1(4) (2012). doi:10.​1161/​JAHA.​112.​001420
38.
Zurück zum Zitat Polak JF, Meisner A, Pencina MJ, Wolf PA, D’Agostino RB (2012) Variations in common carotid artery intima-media thickness during the cardiac cycle: implications for cardiovascular risk assessment. J Am Soc Echocardiogr 25(9):1023–1028PubMedCentralPubMedCrossRef Polak JF, Meisner A, Pencina MJ, Wolf PA, D’Agostino RB (2012) Variations in common carotid artery intima-media thickness during the cardiac cycle: implications for cardiovascular risk assessment. J Am Soc Echocardiogr 25(9):1023–1028PubMedCentralPubMedCrossRef
39.
Zurück zum Zitat Rocha R, Campilho A, Silva J, Azevedo E, Santos R (2010) Segmentation of the carotid intima-media region in B-mode ultrasound images. Image Vis Comput 28(4):614–625CrossRef Rocha R, Campilho A, Silva J, Azevedo E, Santos R (2010) Segmentation of the carotid intima-media region in B-mode ultrasound images. Image Vis Comput 28(4):614–625CrossRef
40.
Zurück zum Zitat Rossi AC, Brands PJ, Hoeks APG (2010) Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: a novel algorithm providing scan quality control. Ultrasound Med Biol 36(3):467–479PubMedCrossRef Rossi AC, Brands PJ, Hoeks APG (2010) Automatic localization of intimal and adventitial carotid artery layers with noninvasive ultrasound: a novel algorithm providing scan quality control. Ultrasound Med Biol 36(3):467–479PubMedCrossRef
41.
Zurück zum Zitat Sandrock M, Hansel J, Schulze J, Schmitz D, Niess A, Burkhardt H, Schmidt-Trucksäss A (2008) Sequentially based analysis versus image based analysis of intima media thickness in common carotid arteries studies—do major IMT studies underestimate the true relations for cardio-and cerebrovascular risk? Cardiovasc Ultrasound 6(32):1–8 Sandrock M, Hansel J, Schulze J, Schmitz D, Niess A, Burkhardt H, Schmidt-Trucksäss A (2008) Sequentially based analysis versus image based analysis of intima media thickness in common carotid arteries studies—do major IMT studies underestimate the true relations for cardio-and cerebrovascular risk? Cardiovasc Ultrasound 6(32):1–8
42.
Zurück zum Zitat Schaar JA, Muller JE, Falk E, Virmani R, Fuster V, Serruys PW, Colombo A, Stefanadis C, Ward CS, Moreno PR, Maseri A, van der Steen AFW (2003) Terminology for high-risk and vulnerable coronary artery plaques. Report of a meeting on the vulnerable plaque, June 17 and 18, (2003) Santorini, Greece. Eur Heart J 25(12):1077–1082 CrossRef Schaar JA, Muller JE, Falk E, Virmani R, Fuster V, Serruys PW, Colombo A, Stefanadis C, Ward CS, Moreno PR, Maseri A, van der Steen AFW (2003) Terminology for high-risk and vulnerable coronary artery plaques. Report of a meeting on the vulnerable plaque, June 17 and 18, (2003) Santorini, Greece. Eur Heart J 25(12):1077–1082 CrossRef
43.
Zurück zum Zitat Selzer RH, Hodis HN, Kwong-Fu H, Mack WJ, Lee PL, Liu CR, Liu CH (1994) Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images. Atherosclerosis 111(1):1–11PubMedCrossRef Selzer RH, Hodis HN, Kwong-Fu H, Mack WJ, Lee PL, Liu CR, Liu CH (1994) Evaluation of computerized edge tracking for quantifying intima-media thickness of the common carotid artery from B-mode ultrasound images. Atherosclerosis 111(1):1–11PubMedCrossRef
44.
Zurück zum Zitat Selzer RH, Mack WJ, Lee PL, Kwong-Fu H, Hodis HN (2001) Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames. Atherosclerosis 154(1):185–193PubMedCrossRef Selzer RH, Mack WJ, Lee PL, Kwong-Fu H, Hodis HN (2001) Improved common carotid elasticity and intima-media thickness measurements from computer analysis of sequential ultrasound frames. Atherosclerosis 154(1):185–193PubMedCrossRef
46.
Zurück zum Zitat Teynor A, Caviezel S, Dratva J, Künzli N, Schmidt-Trucksäss A (2012) An automated, interactive analysis system for ultrasound sequences of the common carotid artery. Ultrasound Med Biol 38(8):1440–1450PubMedCrossRef Teynor A, Caviezel S, Dratva J, Künzli N, Schmidt-Trucksäss A (2012) An automated, interactive analysis system for ultrasound sequences of the common carotid artery. Ultrasound Med Biol 38(8):1440–1450PubMedCrossRef
47.
Zurück zum Zitat Touboul PJ, Hennerici MG, Meairs S, Adams H, Amarenco P, Bornstein N, Csiba L, Desvarieux M, Ebrahim S, Jaff M, Kownator S, Naqvi T, Prati P, Rundek T, Sitzer M, Schminke U, Tardif JC, Taylor A, Vicaut E, Woo KS (2012) Mannheim carotid intima-media thickness and plaque consensus (2004–2006–2011). Cerebrovasc Dis 34:290–296PubMedCentralPubMedCrossRef Touboul PJ, Hennerici MG, Meairs S, Adams H, Amarenco P, Bornstein N, Csiba L, Desvarieux M, Ebrahim S, Jaff M, Kownator S, Naqvi T, Prati P, Rundek T, Sitzer M, Schminke U, Tardif JC, Taylor A, Vicaut E, Woo KS (2012) Mannheim carotid intima-media thickness and plaque consensus (2004–2006–2011). Cerebrovasc Dis 34:290–296PubMedCentralPubMedCrossRef
48.
Zurück zum Zitat Trawiński Z (2008) Ultrasonic method for relative changes of intima-media thickness measurements in common carotid artery. Hydroacoustics 11:411–418 Trawiński Z (2008) Ultrasonic method for relative changes of intima-media thickness measurements in common carotid artery. Hydroacoustics 11:411–418
49.
Zurück zum Zitat Trawiński Z, Powałowski T (2006) Modeling and ultrasonic examination of common carotid artery wall thickness changes. Arch Acoust 31:29–34 Trawiński Z, Powałowski T (2006) Modeling and ultrasonic examination of common carotid artery wall thickness changes. Arch Acoust 31:29–34
50.
Zurück zum Zitat Wijeysundera HC, Machado M, Farahati F, Wang X, Witteman W, van der Velde G, Tu JV, Lee DS, Goodman SG, Petrella R, O’Flaherty M, Krahn M, Capewell S (2010) Association of temporal trends in risk factors and treatment uptake with coronary heart disease mortality, 1994–2005. JAMA J Am Med Assoc 303(18):1841–1847CrossRef Wijeysundera HC, Machado M, Farahati F, Wang X, Witteman W, van der Velde G, Tu JV, Lee DS, Goodman SG, Petrella R, O’Flaherty M, Krahn M, Capewell S (2010) Association of temporal trends in risk factors and treatment uptake with coronary heart disease mortality, 1994–2005. JAMA J Am Med Assoc 303(18):1841–1847CrossRef
51.
Zurück zum Zitat Wikstrand J (2007) Methodological considerations of ultrasound measurement of carotid artery intima-media thickness and lumen diameter. Clin Physiol Funct Imaging 27(6):341–345PubMedCrossRef Wikstrand J (2007) Methodological considerations of ultrasound measurement of carotid artery intima-media thickness and lumen diameter. Clin Physiol Funct Imaging 27(6):341–345PubMedCrossRef
52.
Zurück zum Zitat Woodman RJ, Playford DA, Watts GF, Cheetham C, Reed C, Taylor RR, Puddey IB, Beilin LJ, Burke V, Mori TA, Green D (2001) Improved analysis of brachial artery ultrasound using a novel edge-detection software system. J Appl Physiol 91(2):929–937PubMed Woodman RJ, Playford DA, Watts GF, Cheetham C, Reed C, Taylor RR, Puddey IB, Beilin LJ, Burke V, Mori TA, Green D (2001) Improved analysis of brachial artery ultrasound using a novel edge-detection software system. J Appl Physiol 91(2):929–937PubMed
53.
Zurück zum Zitat Zahnd G, Vray D, Sérusclat A, Alibay D, Bartold M, Brown A, Durand M, Jamieson LM, Kapellas K, Maple-Brown LJ, O’Dea K, Moulin P, Celermajer DS, Skilton MR (2012) Longitudinal displacement of the carotid wall and cardiovascular risk factors: associations with aging, adiposity, blood pressure and periodontal disease independent of cross-sectional distensibility and intima-media thickness. Ultrasound Med Biol 38(10):1705–1715PubMedCrossRef Zahnd G, Vray D, Sérusclat A, Alibay D, Bartold M, Brown A, Durand M, Jamieson LM, Kapellas K, Maple-Brown LJ, O’Dea K, Moulin P, Celermajer DS, Skilton MR (2012) Longitudinal displacement of the carotid wall and cardiovascular risk factors: associations with aging, adiposity, blood pressure and periodontal disease independent of cross-sectional distensibility and intima-media thickness. Ultrasound Med Biol 38(10):1705–1715PubMedCrossRef
Metadaten
Titel
Simultaneous extraction of carotid artery intima-media interfaces in ultrasound images: assessment of wall thickness temporal variation during the cardiac cycle
verfasst von
Guillaume Zahnd
Maciej Orkisz
André Sérusclat
Philippe Moulin
Didier Vray
Publikationsdatum
01.07.2014
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 4/2014
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-013-0945-0

Weitere Artikel der Ausgabe 4/2014

International Journal of Computer Assisted Radiology and Surgery 4/2014 Zur Ausgabe