Skip to main content
Erschienen in: International Journal of Computer Assisted Radiology and Surgery 7/2015

01.07.2015 | Original Article

Deformable registration of preoperative MR, pre-resection ultrasound, and post-resection ultrasound images of neurosurgery

verfasst von: Hassan Rivaz, D. Louis Collins

Erschienen in: International Journal of Computer Assisted Radiology and Surgery | Ausgabe 7/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Purpose

Sites that use ultrasound (US) in image-guided neurosurgery (IGNS) of brain tumors generally have three sets of imaging data: preoperative magnetic resonance (MR) image, pre-resection US, and post-resection US. The MR image is usually acquired days before the surgery, the pre-resection US is obtained after the craniotomy but before the resection, and finally, the post-resection US scan is performed after the resection of the tumor. The craniotomy and tumor resection both cause brain deformation, which significantly reduces the accuracy of the MR–US alignment.

Method

Three unknown transformations exist between the three sets of imaging data: MR to pre-resection US, pre- to post-resection US, and MR to post-resection US. We use two algorithms that we have recently developed to perform the first two registrations (i.e., MR to pre-resection US and pre- to post-resection US). Regarding the third registration (MR to post-resection US), we evaluate three strategies. The first method performs a registration between the MR and pre-resection US, and another registration between the pre- and post-resection US. It then composes the two transformations to register MR and post-resection US; we call this method compositional registration. The second method ignores the pre-resection US and directly registers the MR and post-resection US; we refer to this method as direct registration. The third method is a combination of the first and second: it uses the solution of the compositional registration as an initial solution for the direct registration method. We call this method group-wise registration.

Results

We use data from 13 patients provided in the MNI BITE database for all of our analysis. Registration of MR and pre-resection US reduces the average of the mean target registration error (mTRE) from 4.1 to 2.4 mm. Registration of pre- and post-resection US reduces the average mTRE from 3.7 to 1.5 mm. Regarding the registration of MR and post-resection US, all three strategies reduce the mTRE. The initial average mTRE is 5.9 mm, which reduces to 3.3 mm with the compositional method, 2.9 mm with the direct technique, and 2.8 mm with the group-wise method.

Conclusion

Deformable registration of MR and pre- and post-resection US images significantly improves their alignment. Among the three methods proposed for registering the MR to post-resection US, the group-wise method gives the lowest TRE values. Since the running time of all registration algorithms is less than 2 min on one core of a CPU, they can be integrated into IGNS systems for interactive use during surgery.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Hill D, Maurer C, Maciunas R, Barwise J, Fitzpatrick M, Wang M (1998) Measurement of intraoperative brain surface deformation under a craniotomy. Neurosurgery 43(3):514–526PubMedCrossRef Hill D, Maurer C, Maciunas R, Barwise J, Fitzpatrick M, Wang M (1998) Measurement of intraoperative brain surface deformation under a craniotomy. Neurosurgery 43(3):514–526PubMedCrossRef
2.
Zurück zum Zitat Roberts D, Hartov A, Kennedy F, Miga M, Paulsen K (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43(4):749–758PubMedCrossRef Roberts D, Hartov A, Kennedy F, Miga M, Paulsen K (1998) Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases. Neurosurgery 43(4):749–758PubMedCrossRef
3.
Zurück zum Zitat Ji S, Fan X, Hartov A, Roberts DW, Paulsen KD (2012) Estimation of intraoperative brain deformation. In: Soft tissue biomechanical modeling for computer assisted surgery. Springer, New York, pp 97–133 Ji S, Fan X, Hartov A, Roberts DW, Paulsen KD (2012) Estimation of intraoperative brain deformation. In: Soft tissue biomechanical modeling for computer assisted surgery. Springer, New York, pp 97–133
4.
Zurück zum Zitat Kuhnt D, Bauer MH, Nimsky C (2012) Brain shift compensation and neurosurgical image fusion using intraoperative MRI: current status and future challenges. Crit Rev Biomed Eng 40(3):175–185 Kuhnt D, Bauer MH, Nimsky C (2012) Brain shift compensation and neurosurgical image fusion using intraoperative MRI: current status and future challenges. Crit Rev Biomed Eng 40(3):175–185
5.
Zurück zum Zitat Nabavi A, Black P et al (2001) Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery 48(4):787–798PubMed Nabavi A, Black P et al (2001) Serial intraoperative magnetic resonance imaging of brain shift. Neurosurgery 48(4):787–798PubMed
6.
Zurück zum Zitat Nimsky C, Fujita A, Ganslandt O, Von Keller B, Fahlbusch R (2004) Volumetric assessment of glioma removal by intraoperative high-field magnetic resonance imaging. Neurosurgery 55(4):358–370PubMedCrossRef Nimsky C, Fujita A, Ganslandt O, Von Keller B, Fahlbusch R (2004) Volumetric assessment of glioma removal by intraoperative high-field magnetic resonance imaging. Neurosurgery 55(4):358–370PubMedCrossRef
7.
Zurück zum Zitat Truwit C, Martin AJ, Hall WA (2012) MRI guidance of minimally invasive cranial applications. In: Interventional magnetic resonance imaging. Springer, New York, pp 97–112 Truwit C, Martin AJ, Hall WA (2012) MRI guidance of minimally invasive cranial applications. In: Interventional magnetic resonance imaging. Springer, New York, pp 97–112
8.
Zurück zum Zitat Giordano M, Gerganov VM, Metwali H, Fahlbusch R, Samii A, Samii M, Bertalanffy H (2014) Feasibility of cervical intramedullary diffuse glioma resection using intraoperative magnetic resonance imaging. Neurosurg Rev 37(1):139–146CrossRef Giordano M, Gerganov VM, Metwali H, Fahlbusch R, Samii A, Samii M, Bertalanffy H (2014) Feasibility of cervical intramedullary diffuse glioma resection using intraoperative magnetic resonance imaging. Neurosurg Rev 37(1):139–146CrossRef
9.
Zurück zum Zitat Czyż M, Tabakow P, Weiser A, Lechowicz-Głogowska B, Zub L, Jarmundowicz W (2014) The safety and effectiveness of low field intraoperative mri guidance in frameless stereotactic biopsies of brain tumoursdesign and interim analysis of a prospective randomized trial. Neurosurg Rev 37(1):127–137PubMedCentralPubMedCrossRef Czyż M, Tabakow P, Weiser A, Lechowicz-Głogowska B, Zub L, Jarmundowicz W (2014) The safety and effectiveness of low field intraoperative mri guidance in frameless stereotactic biopsies of brain tumoursdesign and interim analysis of a prospective randomized trial. Neurosurg Rev 37(1):127–137PubMedCentralPubMedCrossRef
10.
Zurück zum Zitat Sommer B, Grummich P, Coras R, Kasper BS, Blumcke I, Hamer HM, Stefan H, Buchfelder M, Roessler K (2013) Integration of functional neuronavigation and intraoperative mri in surgery for drug-resistant extratemporal epilepsy close to eloquent brain areas. Neurosurg Focus 34(4):E4PubMedCrossRef Sommer B, Grummich P, Coras R, Kasper BS, Blumcke I, Hamer HM, Stefan H, Buchfelder M, Roessler K (2013) Integration of functional neuronavigation and intraoperative mri in surgery for drug-resistant extratemporal epilepsy close to eloquent brain areas. Neurosurg Focus 34(4):E4PubMedCrossRef
11.
Zurück zum Zitat Black P, Jolesz FA, Medani K (2011) From vision to reality: the origins of intraoperative mr imaging. In: Intraoperative imaging. Springer, New York, pp 3–7 Black P, Jolesz FA, Medani K (2011) From vision to reality: the origins of intraoperative mr imaging. In: Intraoperative imaging. Springer, New York, pp 3–7
12.
Zurück zum Zitat Keles G, Lamborn K, Berger S (2003) Coregistration accuracy and detection of brain shift using intraoperative sononavigation during resection of hemispheric tumors. Neurosurgery 53:556–562PubMedCrossRef Keles G, Lamborn K, Berger S (2003) Coregistration accuracy and detection of brain shift using intraoperative sononavigation during resection of hemispheric tumors. Neurosurgery 53:556–562PubMedCrossRef
13.
Zurück zum Zitat Unsgaard A, Selbekk T, Gronningsaeter S, Ommedal S, Nagelhus H (2005) Ability of navigated 3D ultra-sound to delineate gliomas and metastases: comparison of image interpretations with histopathology. Acta Neurochir 147(4):1259–1269PubMedCrossRef Unsgaard A, Selbekk T, Gronningsaeter S, Ommedal S, Nagelhus H (2005) Ability of navigated 3D ultra-sound to delineate gliomas and metastases: comparison of image interpretations with histopathology. Acta Neurochir 147(4):1259–1269PubMedCrossRef
14.
Zurück zum Zitat Letteboer M, Willems P, Viergever M, Niessen W (2005) Brain shift estimation in image-guided neurosurgery using 3-d ultrasound. IEEE Trans Med Imag 52:267–276 Letteboer M, Willems P, Viergever M, Niessen W (2005) Brain shift estimation in image-guided neurosurgery using 3-d ultrasound. IEEE Trans Med Imag 52:267–276
15.
Zurück zum Zitat Rygh O, Selbekk T, Torp S, Lydersen S, Hernes T, Unsgaard G (2005) Comparison of navigated 3D ultrasound findings with histopathology in subsequent phases of glioblastoma resection. Acta Neurochirur 150(10):1033–1042CrossRef Rygh O, Selbekk T, Torp S, Lydersen S, Hernes T, Unsgaard G (2005) Comparison of navigated 3D ultrasound findings with histopathology in subsequent phases of glioblastoma resection. Acta Neurochirur 150(10):1033–1042CrossRef
16.
Zurück zum Zitat Miller D, Benes L, Sure U (2011) Stand-alone 3d-ultrasound navigation after failure of conventional image guidance for deep-seated lesions. Neurosurg Rev 34(3):381–388PubMedCrossRef Miller D, Benes L, Sure U (2011) Stand-alone 3d-ultrasound navigation after failure of conventional image guidance for deep-seated lesions. Neurosurg Rev 34(3):381–388PubMedCrossRef
17.
Zurück zum Zitat Ji S, Fan X, Roberts DW, Hartov A, Paulsen KD (2011) Optimizing nonrigid registration performance between volumetric true 3d ultrasound images in image-guided neurosurgery. In: SPIE medical imaging. International Society for Optics and Photonics, pp 79640V–79640V Ji S, Fan X, Roberts DW, Hartov A, Paulsen KD (2011) Optimizing nonrigid registration performance between volumetric true 3d ultrasound images in image-guided neurosurgery. In: SPIE medical imaging. International Society for Optics and Photonics, pp 79640V–79640V
18.
Zurück zum Zitat Ji S, Roberts DW, Hartov A, Paulsen KD et al (2012) Intraoperative patient registration using volumetric true 3d ultrasound without fiducials. Med Phys 39(12):7540PubMedCentralPubMedCrossRef Ji S, Roberts DW, Hartov A, Paulsen KD et al (2012) Intraoperative patient registration using volumetric true 3d ultrasound without fiducials. Med Phys 39(12):7540PubMedCentralPubMedCrossRef
19.
Zurück zum Zitat Mercier L, Fonov V, Haegelen C, Maesstro R, Petrecca K, Collins DL (2012) Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery. Compt Aided Surg 7(1):125–136 Mercier L, Fonov V, Haegelen C, Maesstro R, Petrecca K, Collins DL (2012) Comparing two approaches to rigid registration of three-dimensional ultrasound and magnetic resonance images for neurosurgery. Compt Aided Surg 7(1):125–136
20.
Zurück zum Zitat Selbekk T, Jakola AS, Solheim O, Johansen TF, Lindseth F, Reinertsen I, Unsgård G (2013) Ultrasound imaging in neurosurgery: approaches to minimize surgically induced image artefacts for improved resection control. Acta Neurochirur 155(6):973–980CrossRef Selbekk T, Jakola AS, Solheim O, Johansen TF, Lindseth F, Reinertsen I, Unsgård G (2013) Ultrasound imaging in neurosurgery: approaches to minimize surgically induced image artefacts for improved resection control. Acta Neurochirur 155(6):973–980CrossRef
21.
Zurück zum Zitat Reinertsen I, Jakola A, Friderichsen P, Lindseth F, Solheim O, Selbekk T, Unsgård G (2012) A new system for 3d ultrasound-guided placement of cerebral ventricle catheters. Int J Comput Assist Radiol Surg 7(1):151–157PubMedCrossRef Reinertsen I, Jakola A, Friderichsen P, Lindseth F, Solheim O, Selbekk T, Unsgård G (2012) A new system for 3d ultrasound-guided placement of cerebral ventricle catheters. Int J Comput Assist Radiol Surg 7(1):151–157PubMedCrossRef
22.
Zurück zum Zitat Mercier L, Del Maestro RF, Petrecca K, Araujo D, Haegelen C, Collins DL (2012) Online database of clinical mr and ultrasound images of brain tumors. Med Phys 39:3253PubMedCrossRef Mercier L, Del Maestro RF, Petrecca K, Araujo D, Haegelen C, Collins DL (2012) Online database of clinical mr and ultrasound images of brain tumors. Med Phys 39:3253PubMedCrossRef
23.
Zurück zum Zitat Fan X, Ji S, Fontaine K, Hartov A, Roberts D, Paulsen K (2011) Simulation of brain tumor resection in image-guided neurosurgery. In: SPIE medical imaging. International society for optics and photonics, pp 79640U–79640U Fan X, Ji S, Fontaine K, Hartov A, Roberts D, Paulsen K (2011) Simulation of brain tumor resection in image-guided neurosurgery. In: SPIE medical imaging. International society for optics and photonics, pp 79640U–79640U
24.
Zurück zum Zitat Fan X, Ji S, Hartov A, Roberts D, Paulsen K (2013) Retractor-induced brain shift compensation in image-guided neurosurgery. In: SPIE medical imaging. International Society for Optics and Photonics, pp 86710K–86710K Fan X, Ji S, Hartov A, Roberts D, Paulsen K (2013) Retractor-induced brain shift compensation in image-guided neurosurgery. In: SPIE medical imaging. International Society for Optics and Photonics, pp 86710K–86710K
25.
Zurück zum Zitat Rivaz H, Boctor EM, Choti MA, Hager GD (2014) Ultrasound elastography using multiple images. Med Image Anal 18(2):314–329PubMedCrossRef Rivaz H, Boctor EM, Choti MA, Hager GD (2014) Ultrasound elastography using multiple images. Med Image Anal 18(2):314–329PubMedCrossRef
28.
Zurück zum Zitat Roche A, Pennec X, Malandain G, Ayache N (2001) Rigid registration of 3-d ultrasound with mr images: a new approach combining intensity and gradient information. IEEE Trans Med Imag 20(72):291–237 Roche A, Pennec X, Malandain G, Ayache N (2001) Rigid registration of 3-d ultrasound with mr images: a new approach combining intensity and gradient information. IEEE Trans Med Imag 20(72):291–237
29.
Zurück zum Zitat Arbel T, Morandi X, Comeau R, Collins DL (2004) Automatic non-linear mri-ultrasound registration for the correction of intra-operative brain deformations. Comput Aided Surg 9(4):123–136PubMedCrossRef Arbel T, Morandi X, Comeau R, Collins DL (2004) Automatic non-linear mri-ultrasound registration for the correction of intra-operative brain deformations. Comput Aided Surg 9(4):123–136PubMedCrossRef
30.
Zurück zum Zitat Collins DL, Neelin P, Peters TM, Evans AC (1994) Automatic 3d intersubject registration of mr volumetric data in standardized talairach space. J Comput Assist Tomogr 18(2):192–205PubMedCrossRef Collins DL, Neelin P, Peters TM, Evans AC (1994) Automatic 3d intersubject registration of mr volumetric data in standardized talairach space. J Comput Assist Tomogr 18(2):192–205PubMedCrossRef
31.
Zurück zum Zitat Kuklisova-Murgasova M, Cifor A, Napolitano R, Papageorghiou A, Quaghebeur G, Rutherford MA, Hajnal JV, Alison Noble J, Schnabel JA (2013) Registration of 3d fetal neurosonography and mri. Med Image Anal 17(8):1137–1150 Kuklisova-Murgasova M, Cifor A, Napolitano R, Papageorghiou A, Quaghebeur G, Rutherford MA, Hajnal JV, Alison Noble J, Schnabel JA (2013) Registration of 3d fetal neurosonography and mri. Med Image Anal 17(8):1137–1150
32.
Zurück zum Zitat Penney G, Blackall J, Hamady M, Sabharwal T, Adam A, Hawks D (2004) Registration of freehand 3d ultrasound and magnetic resonance liver images. Med Imag Anal 8(1):81–91CrossRef Penney G, Blackall J, Hamady M, Sabharwal T, Adam A, Hawks D (2004) Registration of freehand 3d ultrasound and magnetic resonance liver images. Med Imag Anal 8(1):81–91CrossRef
33.
Zurück zum Zitat Ji S, Wu Z, Hartov A, Roberts D, Paulsen K (2008) Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery. Med Phys 35(10):4612–4624PubMedCentralPubMedCrossRef Ji S, Wu Z, Hartov A, Roberts D, Paulsen K (2008) Mutual-information-based image to patient re-registration using intraoperative ultrasound in image-guided neurosurgery. Med Phys 35(10):4612–4624PubMedCentralPubMedCrossRef
34.
Zurück zum Zitat Hartov A, Roberts DW, Paulsen KD (2008) A comparative analysis of coregistered ultrasound and magnetic resonance imaging in neurosurgery. Neurosurgery 62(3):91–101PubMedCrossRef Hartov A, Roberts DW, Paulsen KD (2008) A comparative analysis of coregistered ultrasound and magnetic resonance imaging in neurosurgery. Neurosurgery 62(3):91–101PubMedCrossRef
35.
Zurück zum Zitat Brooks R, Collins DL, Morandi X, Arbel T (2008) Deformable ultrasound registration without reconstruction. In: Medical image computing and computer-assisted intervention-MICCAI 2008. Springer, New York, pp 1023–1031 Brooks R, Collins DL, Morandi X, Arbel T (2008) Deformable ultrasound registration without reconstruction. In: Medical image computing and computer-assisted intervention-MICCAI 2008. Springer, New York, pp 1023–1031
36.
Zurück zum Zitat Zhang W, Brady M, Becher H, Noble A (2011) Spatio-temporal (2d+t) non-rigid registration of real-time 3d echocardiography and cardiovascular mr image sequences. Phys Med Biol 56:1341–1360PubMedCrossRef Zhang W, Brady M, Becher H, Noble A (2011) Spatio-temporal (2d+t) non-rigid registration of real-time 3d echocardiography and cardiovascular mr image sequences. Phys Med Biol 56:1341–1360PubMedCrossRef
37.
Zurück zum Zitat Kybic J, Unser M (2003) Fast parametric elastic image registration. IEEE Trans Med Imaging 12:1427–1442 Kybic J, Unser M (2003) Fast parametric elastic image registration. IEEE Trans Med Imaging 12:1427–1442
38.
Zurück zum Zitat Rivaz H, Boctor EM, Choti MA, Hager GD (2011) Real-time regularized ultrasound elastography. IEEE Trans Med Imaging 30(4):928–945PubMedCrossRef Rivaz H, Boctor EM, Choti MA, Hager GD (2011) Real-time regularized ultrasound elastography. IEEE Trans Med Imaging 30(4):928–945PubMedCrossRef
39.
Zurück zum Zitat Jannin P, Fitzpatrick JM, Hawkes DJ, Pennec X, Shahidi R, Vannier MW (2002) Validation of medical image processing in image-guided therapy. Neurosurgery 21(2):1445–1449 Jannin P, Fitzpatrick JM, Hawkes DJ, Pennec X, Shahidi R, Vannier MW (2002) Validation of medical image processing in image-guided therapy. Neurosurgery 21(2):1445–1449
Metadaten
Titel
Deformable registration of preoperative MR, pre-resection ultrasound, and post-resection ultrasound images of neurosurgery
verfasst von
Hassan Rivaz
D. Louis Collins
Publikationsdatum
01.07.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 7/2015
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-014-1099-4

Weitere Artikel der Ausgabe 7/2015

International Journal of Computer Assisted Radiology and Surgery 7/2015 Zur Ausgabe