Abstract
Voltammetric method for the determination of non-steroidal anti-inflammatory drug mesalazine (5-ASA) is presented for the first time using boron-doped diamond electrode (BDDE). 5-ASA provides one well-developed SWV oxidation peak at about −900 mV (vs. saturated silver/silver chloride reference electrode) on BDDE. Britton-Robinson buffer (pH 7.0) was chosen as an optimal supporting electrolyte for the determination of 5-ASA using square wave voltammetry (SWV). Parameters of SWV were developed and low limit of detection (7.0 × 10−7 mol L−1) was reached. In addition, relative standard deviation of repeated measurements (c 5-ASA = 5 × 10−5 mol L−1, RSDM = 2.7%) and relative standard deviation of repeated determinations (RSDD < 1.5%) were calculated and confirm obtained good results. Applicability of the proposed method was verified by an analysis of a pharmaceutical preparation and spiked human urine.
Similar content being viewed by others
References
Abdolmohammad-Zadeh H, Kohansal S (2012) Determination of mesalamine by spectrofluorometry in human serum after solid-phase extraction with Ni-Al layered double hydroxide as a nanosorbent. J Braz Chem Soc 23:473–481. doi:10.1590/S0103-50532012000300014
Acharjya SK, Sahu A, Das S, Sagar P, Annapurna MM (2010) Spectrophotometric methods for the determination of mesalamine in bulk and pharmaceutical dosage forms. J Pharm Educ Res 1:63–67
Ahnfelt-Ronne I, Nielsen OH, Christensen A, Langholz E, Binder V, Riis P (1990) Clinical evidence supporting the radical scavenger mechanism of 5-aminosalicylic acid. Gatroenterology 98:1162–1169. doi:10.1016/0016-5085(90)90329-Y
Barek J, Fischer J, Navrátil T, Pecková K, Yosypchuk B, Zima J (2007) Nontraditional electrode materials in environmental analysis of biologically active organic compounds. Electroanalysis 19:2003–2014. doi:10.1002/elan.200703918
Beckett EL, Lawrence NS, Evans RG, Davis J, Compton RG (2001) Sonoelectrochemically enhanced determination of 5-aminosalicylic acid. Talanta 54:871–877. doi:10.1016/S0039-9140(01)00337-X
Bystrowska B, Nowak J, Brandys J (2000) Validation of a LC method for the determination of 5-aminosalicylic acid and its metabolite in plasma and urine. J Pharm Biomed Anal 22:341–347. doi:10.1016/S0731-7085(99)00292-7
Gotti R, Pomponio R, Bertucci C, Cavrini V (2001) Determination of 5-aminosalicylic acid related impurities by micellar electrokinetic chromatography with an ion-pair reagent. J Chromatogr A 916:175–183. doi:10.1016/S0021-9673(00)01097-9
Iacucci M, Silva S, Ghosd S (2010) Mesalazine in inflammatory bowel disease: a trendy topic once again? Can J Gastroenterol 24:127–133. doi:10.1155/2010/586092
Janíková-Bandžuchová L, Šelešovská R, Schwarzová-Pecková K, Chýlková J (2015) Sensitive voltammetric method for rapid determination of pyridine herbicide triclopyr on bare boron-doped diamond electrode. Electrochim Acta 154:421–429. doi:10.1016/j.electacta.2014.12.064
Joshi R, Kumar S, Unnikrishnan M, Mukherjee T (2005) Free radical scavenging reactions of sulfasalazine, 5-aminosalicylic acid and sulfapyridine: mechanistic aspects and antioxidant activity. Free Radic Res 39:1163–1172. doi:10.1080/10715760500177880
Kraft A (2007) Doped diamond: a compact review on a new versatile electrode. Int J Electrochem Sci 2:355–385
Moharana AK, Banerjee M, Panda S, Muduli JN (2011) Development and validation of UV spectrophotometric method for the determination of mesalamine in bulk and tablet formulation. Int J Pharm Pharm Sci 3:19–21. ISSN- 0975-1491
Musilová J, Barek J, Pecková K (2009) Použití diamantových filmových elektrod dopovaných borem pro stanovení organických látek. Chem Listy 103:469–478
Nigović B, Šimunić B (2003) Determination of 5-aminosalicylic acid in pharmaceutical formulation by differential pulse voltammetry. J Pharm Biomed Anal 31:169–174. doi:10.1016/S0731-7085(02)00469-7
Nobilis M, Vybíralová Z, Sládková K, Lísa M, Holčapek M, Květina J (2006) High-performance liquid-chromatographic determination of 5-aminosalicylic acid and its metabolites in blood plasma. J Chromatogr A 1119:299–308. doi:10.1016/j.chroma.2006.01.058
Palsmeier RK, Radzik DM, Lunte CE (1992) Investigation of the degradation mechanism of 5-aminosalicylic acid in aqueous solution. Pharm Res 9:933–938. doi:10.1023/A:1015813302412
Pastorini E, Locatelli M, Simon P, Roda G, Roda E, Roda A (2008) Development and validation of a HPLC-ESI-MS/MS method for the determination of 5-aminosalicylic acid and its major metabolite N-acetyl-5-aminosalicylic acid in human plasma. J Chromatogr B 872:99–106. doi:10.1016/j.jchromb.2008.07.026
Pecková K, Barek J (2011) Boron doped diamond microelectrodes and microelectrode arrays in organic electrochemistry. Curr Org Chem 15:3014–3028. doi:10.2174/138527211798357164
Pecková K, Musilová J, Barek J (2009) Boron-doped diamond film electrodes—new tool for Voltammetric determination of organic substances. Crit Rev Anal Chem 39:148–172. doi:10.1080/10408340903011812
Pithadia AB, Jain S (2011) Treatment of inflammatory bowel disease (IBD). Pharmacol Rep 63:629–642. doi:10.1016/S1734-1140(11)70575-8
Pleskov YV, Sakharova AY, Krotova MD, Bouilov LL, Spitsyn BV (1987) Photoelectrochemical properties of semiconductor diamond. J Electroanal Chem 228:19–27. doi:10.1016/0022-0728(87)80093-1
Punchard NA, Greenfield SM, Thompson RPH (1992) Mechanism of action of 5-aminosalicylic acid. Mediat Inflamm 1:151–165. doi:10.1155/S0962935192000243
Qureshia AI, Cohenb RD (2005) Mesalamine delivery systems: do they really make much difference? Adv Drug Deliv Rev 57:281–302. doi:10.1016/j.addr.2004.08.008
Rao TN, Loo BH, Sarada BV, Terashima C, Fujishima A (2002) Electrochemical detection of carbamate pesticides at conductive diamond electrodes. Anal Chem 74:1578–1583. doi:10.1021/ac010935d
Sartori ER, Medeiros RA, Rocha-Filho RC, Fatibello-Filho O (2010) Square-wave voltammetric determination of propranolol and atenolol in pharmaceuticals using a boron-doped diamond electrode. Talanta 81:1418–1424. doi:10.1016/j.talanta.2010.02.046
Šelešovská R, Janíková-Bandžuchová L, Chýlková J (2015) Sensitive voltammetric sensor based on boron-doped diamond electrode for determination of the chemotherapeutic drug methotrexate in pharmaceutical and biological samples. Electroanalysis 27:42–51. doi:10.1002/elan.201400326
Šelešovská R, Janíková L, Pithardtová K, Chýlková J, Tomášková M (2016a) Sensitive voltammetric determination of herbicide terbutryn using solid electrodes based on silver amalgam and boron-doped diamond. Monatsh Chem 147:207–217. doi:10.1007/s00706-015-1556-y
Šelešovská R, Štěpánková M, Janíková L, Nováková K, Vojs M, Marton M, Behúl M (2016b) Surface and electrochemical characterization of boron-doped diamond electrodes prepared under different conditions. Monatsh Chem 147:1353–1364. doi:10.1007/s00706-015-1640-3
Shahrokhian S, Hosseini P, Kamalzadeh Z (2013) Investigation of the electrochemical behavior of mesalazine on the surface of a glassy carbon Electrode modified with CNT/PPY doped by 1,5-naphthalenedisulfonic acid. Electroanalysis 25:2481–2491. doi:10.1002/elan.201300333
Švorc Ľ, Rievaj M, Bustin D (2013) Green electrochemical sensor for environmental monitoring of pesticides: determination of atrazine in river waters using a boron-doped diamond electrode. Sens Actuators B 181:294–300. doi:10.1016/j.snb.2013.02.036
Uliana CV, Yamanaka H, Garbellini GS, Salazar-Banda GR (2010) Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes. Quim Nova 33:964–967. doi:10.1590/S0100-40422010000400036
van Bodegraven AA, Mulder CJJ (2006) Indications for 5-aminosalicylate in inflammatory bowel disease: is the body of evidence complete? World J Gastroenterol 12:6115–6123. doi:10.3748/wjg.v12.i38.6115
Wangfuengkanagul N, Chailapakul O (2002) Electrochemical analysis of acetaminophen using a boron-doped diamond thin film electrode applied to flow injection system. J Pharm Biomed Anal 28:841–847. doi:10.1016/S0731-7085(01)00695-1
Xu J, Granger MC, Chen Q, Strojek JW, Lister TE, Swain GM (1997) Boron-doped diamond thin-film electrodes. Anal Chem 69:591A–597A. doi:10.1021/ac971791z
Zavazalova J, Barek J, Peckova K (2014) Boron doped diamond electrodes in voltammetry: New designs and applications. An overview. Sens Electroanal 8:21. ISBN: 978-80-7395-782-7
Acknowledgements
This work was supported by the University of Pardubice (Project No. SGS_2017_002).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Štěpánková, M., Šelešovská, R., Janíková, L. et al. Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode. Chem. Pap. 71, 1419–1427 (2017). https://doi.org/10.1007/s11696-017-0135-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11696-017-0135-6