Choosing configurations of transmission line tower grounding by back flashover probability value

  • Research Article
  • Published:
Frontiers in Energy Aims and scope Submit manuscript

Abstract

There is a considerable number of works devoted to electrical characteristics of grounding. These characteristics are important in general. However, in application to grounding of transmission line towers they are not enough to determine what grounding construction is preferable in some particular case, because these characteristics are calculated or measured apart from the grounded object, and only limited number of current (or voltage) source waveforms is used. This paper indicates reasons in favor of the fact that to choose the optimum design of grounding, the calculation model should include the tower as it is. The probability of back flashover, which provides both qualitative and quantitative estimate of the grounding structure efficiency, can be taken as the criterion for the grounding design. The insulation flashover probability is calculated on the basis of engineering method, which evaluates breakdown strength of insulation for nonstandard waveshapes, and probability data on lightning currents. Different approaches are examined for identifying the back flashover probability, as not only amplitudes but also other parameters can be taken into account. Finite-difference time-domain method is used for calculations of transients. It is found that lightning current waveform can greatly influence calculated back flashover probability value.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Dwight H B. Calculation of resistances to ground. Transactions of the American Institute of Electrical Engineers, 1936, 55(12): 1319–1328

    Article  Google Scholar 

  2. Otero A F, Cidras J, del Alamo J L. Frequency-dependent grounding system calculation by means of a conventional nodal analysis technique. IEEE Transactions on Power Delivery, 1999, 14(3): 873–878

    Article  Google Scholar 

  3. Liu Y, Theethayi N, Thottappillil R. An engineering model for transient analysis of grounding system under lightning strikes: nonuniform transmission-line approach. IEEE Transactions on Power Delivery, 2005, 20(2): 722–730

    Article  Google Scholar 

  4. Grcev L D, Dawalibi F. An electromagnetic model for transients in grounding systems. IEEE Transactions on Power Delivery, 1990, 5 (4): 1773–1781

    Article  Google Scholar 

  5. Tanabe K. Novel method for analyzing the transient behavior of grounding systems based on the finite-difference time-domain method. In: IEEE Power Engineering Society Winter Meeting. Columbus, USA, 2001, 1128–1132

    Google Scholar 

  6. Olsen R G, Willis M C. A comparison of exact and quasi-static methods for evaluating grounding systems at high frequencies. IEEE Transactions on Power Delivery, 1996, 11(2): 1071–1081

    Article  Google Scholar 

  7. Yutthagowith P, Ametani A, Nagaoka N, Baba Y. Application of the partial element equivalent circuit method to tower surge response calculations. IEEJ Transactions on Electrical and Electronic Engineering, 2011, 6(4): 324–330

    Article  Google Scholar 

  8. Sarajcev P, Vujevic S. A review of methods for grounding grid analysis. In: 17th International Conference on Software, Telecommunications Computer Networks, SoftCOM. Hvar, Croatia, 2009, 42–49

    Google Scholar 

  9. Dos Santos T L T, De Oliveira RMS. da S S Sobrinho C L, Almeida J F. Soil ionization in different types of grounding grids simulated by FDTD method. In: SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference (IMOC). 2009, 127–132

    Chapter  Google Scholar 

  10. Thang T H, Baba Y, Nagaoka N, Ametani A, Itamoto N, Rakov V A. FDTD simulations of corona effect on lightning-induced voltages. IEEE Transactions on Electromagnetic Compatibility, 2014, 56(1): 168–176

    Article  Google Scholar 

  11. Grcev L, Rachidi F. On tower impedances for transient analysis. IEEE Transactions on Power Delivery, 2004, 19(3): 1238–1244

    Article  Google Scholar 

  12. Motoyama H, Kinoshita Y, Nonaka K, Baba Y. Experimental and analytical studies on lightning surge response of 500-kV transmission tower. IEEE Transactions on Power Delivery, 2009, 24(4): 2232–2239

    Article  Google Scholar 

  13. Taflove A, Hagness S C. Computational Electrodynamics: The Finite-Difference Time-Domain Method (Artech House, Incorporated). Berlin, Germany, 2005

    MATH  Google Scholar 

  14. Noda T, Yonezawa R, Yokoyama S, Takahashi Y. Error in propagation velocity due to staircase approximation of an inclined thin wire in FDTD surge simulation. IEEE Transactions on Power Delivery, 2004, 19(4): 1913–1918

    Article  Google Scholar 

  15. Railton C J, Paul D L, Craddock I J, Hilton G S. The treatment of geometrically small structures in FDTD by the modification of assigned material parameters. IEEE Transactions on Antennas and Propagation, 2005, 53(12): 4129–4136

    Article  Google Scholar 

  16. Taniguchi Y, Baba Y, Nagaoka N, Ametani A. An improved thin wire representation for FDTD computations. IEEE Transactions on Antennas and Propagation, 2008, 56(10): 3248–3252

    Article  MathSciNet  Google Scholar 

  17. Guiffaut C, Reineix A, Pecqueux B. New oblique thin wire formalism in the FDTD method with multiwire junctions. IEEE Transactions on Antennas and Propagation, 2012, 60(3): 1458–1466

    Article  MathSciNet  Google Scholar 

  18. Sunde E D. Earth Conduction Effects in Transmission Systems. New York: Dover Publications, 1968

    Google Scholar 

  19. Rakov V A, Borghetti A, Bouquegneau C, Chisholm W A, Cooray V, Cummins K, Diendorfer G, Heidler F, Hussein A M, Ishii M, Nucci C A, Piantini A, Pinto O, Qie X, Rachidi F, Saba M, Shindo T, Schulz W, Thottappillil R, Visacro S. Lightning parameters for engineering applications. CIGRE, 2013, Tech Broch no. 549

    Google Scholar 

  20. La Forest J J. Transmission line reference book, 345 kV and above. Electric Power Research Institute, 1982

    Google Scholar 

  21. Heidler F, Cvetic J. A class of analytical functions to study the lightning effects associated with the current front. European Transactions on Electrical Power, 2002, 12(2): 141–150

    Article  Google Scholar 

  22. CIGRE. Guide to Procedures for Estimating the Lightning Performance of Transmission Lines., 2015-02-27, http://c4.cigre. org/WG-Area/WG-C4.23-Guide-to-Procedures-for-Estimating-the- Lightning-Performance-of-Transmission-Lines

  23. Vainer A L. Leaking of current from elements of reinforced concrete foundations of transmission line towers. Elektrichestvo, 1960, (12): 34–40 (in Russian)

    Google Scholar 

  24. Korsuncev A V, Pokrovskaya K I. Reinforced concrete foundations resistance calculation technique. Elektricheskie Stancii, 1968, (11): 63–68 (in Russian)

    Google Scholar 

  25. Vainer A L. Leaking of current from reinforced concrete foundations in soils with high resistivity. Elektrichestvo, 1970, (11): 74–77(in Russian)

    MathSciNet  Google Scholar 

  26. Caldwell R O, Darveniza M. Experimental and analytical studies of the effect of non-standard waveshapes on the impulse strength of external insulation. IEEE Transactions on Power Apparatus and Systems, 1973, PAS-92(4): 1420–1428

    Article  Google Scholar 

  27. Pigini A, Rizzi G, Garbagnati E, Porrino A, Baldo G, Pesavento G. Performance of large air gaps under lightning overvoltages: experimental study and analysis of accuracy predetermination methods. IEEE Transactions on Power Delivery, 1989, 4(2): 1379–1392

    Article  Google Scholar 

  28. Chisholm W A. New challenges in lightning impulse flashover modeling of air gaps and insulators. IEEE Electrical Insulation Magazine, 2010, 26(2): 14–25

    Article  Google Scholar 

  29. Takami J, Okabe S. Observational results of lightning current on transmission towers. IEEE Transactions on Power Delivery, 2007, 22(1): 547–556

    Article  Google Scholar 

  30. Visacro S, Soares A, Schroeder M A O, Cherchiglia L C L, de Sousa V J. Statistical analysis of lightning current parameters: measurements at Morro do Cachimbo Station. Journal of Geophysical Research, D, Atmospheres, 2004, 109(D1): 19–34

    Article  Google Scholar 

  31. Korsuncev A V, Kuznecova S E. Dangerous parameters curves and calculation of probability of transmission line insulation flashover caused by lightning strikes. Izvestiya NIIPT, 1963, (10): 3–17 (in Russian)

    Google Scholar 

  32. Okabe S, Takami J. Evaluation of improved lightning stroke current waveform using advanced statistical method. IEEE Transactions on Power Delivery, 2009, 24(4): 2197–2205

    Article  Google Scholar 

  33. Ballarotti M G, Medeiros C, Saba M M F, Schulz W, Pinto O. Frequency distributions of some parameters of negative downward lightning flashes based on accurate-stroke-count studies. Journal of Geophysical Research, D, Atmospheres, 2012, 117(D6): 2240–2260

    Article  Google Scholar 

  34. Anderson R B, Eriksson A J. Lightning parameters for engineering applications, Electra, 1980, (69): 65–102

    Google Scholar 

  35. Jiang R, Jiang S, Zhang Y, Xu Y, Xu L, Zhang D. GPU-accelerated parallel FDTD on distributed heterogeneous platform. International Journal of Antennas and Propagation, 2014, 18(1): 118–121

    Google Scholar 

  36. Datsios Z G, Mikropoulos P N, Tsovilis T E. Estimation of the minimum shielding failure current causing flashover in overhead lines of the hellenic transmission system through ATP-EMTP simulations. In: 2012 International Conference on Lightning Protection (ICLP). Vienna, Austria, 2012, 1–5

    Chapter  Google Scholar 

  37. De Conti A, Visacro S. Analytical representation of single- and double-peaked lightning current waveforms. IEEE Transactions on Electromagnetic Compatibility, 2007, 49(2): 448–451

    Article  Google Scholar 

  38. Khodr H M, Machado e Moura A, Miranda V. Optimal design of grounding system in transmission line. In: International Conference on Intelligent Systems Applications to Power Systems. Rio de Janeiro, Brazil, 2007, 1–9

    Google Scholar 

  39. Alipio R, Visacro S. Frequency Dependence of Soil Parameters: effect on the lightning response of grounding electrodes. IEEE Transactions on Electromagnetic Compatibility, 2013, 55(1): 132–139

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Dmitry Kuklin.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kuklin, D. Choosing configurations of transmission line tower grounding by back flashover probability value. Front. Energy 10, 213–226 (2016). https://doi.org/10.1007/s11708-016-0398-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11708-016-0398-6

Keywords

Navigation