1 Introduction

Often, it is observed that for very high retaining structures, poor/soft soil strata is not preferred for foundation, as it may lead to higher settlement with lower factor of safety of the overall structure. In such conditions, the technique of soil reinforcement is practiced to construct several cost-effective retaining structures such as retaining walls, bridge abutments etc. in an environment friendly and sustainable method. The commonly preferred reinforcement materials are galvanized steel strips, geosynthetics (in the form of woven geotextiles), geogrids and geocomposites, and fibers from natural and waste products. Reinforcements in the soil can improve the overall stability of the load-bearing structures constructed over the soil mass by using tensile reinforcements in the form of geogrid, when the load-bearing structure is subjected to static and dynamic loading conditions. The previously available literature from past studies and the current design methodologies followed during the construction of reinforced earth structures shows that the provision of reinforcement causes an increment in the load bearing capacity and enhanced overall stability of the retaining structure.

In such cases, tiered MSE walls may prove a safer structure as they will disperse the load on a larger area, leading to a safer solution for earth retaining structures.

Mechanically Stabilized Earth walls are the most common reinforced earth retaining structures. They can withstand much higher surcharge loads and have significant technical and cost advantages over conventional earth retention systems i.e. reinforced concrete retaining walls. In case of high retention of earth mass, MSE walls require a high volume of excavation to lay the reinforcing layer (geogrids), which requires a large land space behind the wall for the positioning of the reinforcing layer effectively. Sometimes, the unavailability of land space required for the placement of the reinforcing layer behind the wall requires an alternative solution because to economize the overall project cost, effective utilization of land space is an essential key. In such conditions, an alternative solution is to construct MSE walls in a tiered configuration because they are practical to construct, structurally sound, economical, aesthetically pleasing, environmentally consistent with the surroundings, and have minimal maintenance problems [1].

A tiered retaining wall system is a series of two or more stacked walls at different levels, where each tier is placed on the backfill surface of the preceding tier and spaced apart at a certain offset distance. When designed suitably, they not only retain the backfill and support the loads but also deliver an attractive appearance and provide room for plantation. This results in a wall having the desired overall height with reduced reinforcement stresses. If the offset is large, each tier may perform internally independent of the other tiers. However, the overall global (slope) stability might be affected [2, 3].

The design methods for 2-tiered and multi-tiered MSE retaining walls are suggested in FHWA [4], NCMA [5], and AASHTO [6], to determine the offset distances of multi-tiered-reinforced soil walls. The upper tier, of a 2-tiered MSE retaining wall, can be treated as an equivalent surcharge, and its magnitude is determined according to the offset distance as mentioned in NCMA.

In AASHTO [6] guidelines, the two tiers in a tiered wall system are considered to be independent of each other if the offset distance between the two tiers is greater than Hm tan(90 − ϕr), where Hm is the height of lower-tier and ϕr is the angle of internal friction of the reinforced soil backfill. Previous studies on multi-tiered-reinforced soil walls have shown that an increment in offset distance reduces the required reinforcement load and facing displacement. These studies demonstrated that the interaction between upper and lower tier creates an effect on the performance of the lower tier. The multi-tiered configuration could considerably reduce the residual lateral facing displacement and the average reinforcement load. In such cases, external and internal stability calculations of the lower-tier are performed assuming lower-tier being a single wall under the equivalent surcharge [7].

The analysis and design of tiered MSE retaining walls are often more complex than the conventional MSE retaining walls. In contrast, reinforcement parameters (length, vertical spacing, and stiffness) for tiered walls cannot be estimated using standard design charts. The behavior of tiered MSE retaining walls is complicated and unfortunately, their behavior in terms of performance under seismic loading has not been well-investigated in the available literature.

In view of above, the present study is aimed to assess the performance of a two-tiered MSE retaining wall each having a height of 6 m is compared with a 12 m high conventional MSE retaining wall with varying reinforcement length under static and seismic loading while evaluating their stability in terms of the factor of safety (FOS) and presents insight into the possible modes of failure of such complicated structures. For the abovementioned objective of the present study, a two-dimensional model is adopted for the simulation of the MSE retaining wall, and the analysis is carried out using the shear strength reduction method using the finite element analysis for the evaluation of the factor of safety of the MSE retaining wall system [8].

2 Numerical modeling of MSE retaining wall

In the present study, FHWA [4] recommendations have been followed to design the walls (spacing and length of reinforcement) and to examine the behavior under gravity and seismic loading using finite element modeling for various lengths of reinforcement. In the present study, various cases of MSE retaining wall (single-tier and two-tier) are considered as a two-dimensional problem for the numerical modeling, as the plane strain conditions prevail in such retaining wall structures, which is best suitable for 2-dimensional analysis [9, 10] with sufficient accuracy and time-saving in the computational analysis. As per the guidelines of FHWA for the design of tiered MSE walls, which suggests that the individual walls in the tiered system can be treated as separate, independent walls when the offset distance, D, exceeds the following criterion:

$$D \, = \, H_{m} \tan \left( {90 \, - \, \varphi_{{\text{r}}} } \right)$$
(1)

where Hm is the height of the lower of the two tiers and φr is the friction angle for the reinforced soil backfill [4].

For the present study, a two-tiered superimposed MSE retaining wall and conventional MSE retaining wall reinforced using geogrid having a total height of 12 m with a rigid facing (concrete blocks) were considered to investigate their stability under gravity and seismic loading.

For the numerical simulation of the structure considered under the study, the actual stress path being experienced by the overall wall system in practice is being followed step by step as described below. A rigid leveling pad (concrete) with dimensions 2.0 m × 0.2 m (in elevation) is laid on the foundation soil over which a rigid concrete facing with dimensions 1.5 m × 0.6 m (in elevation) is laid and behind which a layer of backfill having a lift of 0.6 m is deposited. Before placing the next concrete block as a facing, a geogrid layer of the desired length, L is placed on the finalized backfill surface in the previous lift such that a portion of geogrid length is well-clamped between the successive concrete facings. In the next step, the backfill layer is deposited over the geogrid layer is deposited behind the concrete facing and this procedure is repeated until the desired height of the wall is achieved. Here, the geogrid reinforcement is modeled as an elastic material to withstand the tensile load, and the backfill is considered as an elastoplastic material that follows the Mohr–Coulomb model.

The force transfer mechanism between two dissimilar materials is simulated as an elastoplastic interface and appropriate interface coefficient values are assigned at all the interfaces in the MSE wall system. The interface coefficients for concrete block-geosynthetic interface and soil-geosynthetic interface are taken as 0.8 and 0.65, respectively. For the numerical analysis of geogrid-reinforced soil retaining wall, a series of organized simulations were executed using a finite element based computational tool Optum G2 [11] in the two-dimensional analysis [8].

The stability of the overall structure is evaluated using the strength reduction method and the factor of safety is calculated. The total height of the single-tier wall is considered as 12 m (H) and the height of the two-tiers for lower (H1) and upper (H2) tier is taken as 6 m each (H1 = H2 = 6 m). The offset distance between the two tiers is taken as D = 9 m. Complete details of the geometrical configuration of single-tier and two-tiered MSE retaining walls reinforced with geogrid are shown in Figs. 1 and 2, respectively. Material properties used in the present study are shown in Table 1. To provide the adequate boundary conditions for the reinforced soil wall system, the bottom was kept fixed and roller supports were provided at the vertical edges of the mesh.

Fig. 1
figure 1

Typical mesh for a 12 m high single tier MSE retaining wall considered in the present study

Fig. 2
figure 2

Typical mesh for a two-tier MSE retaining wall having a height of 12 m considered in the present study

Table 1 Material properties considered in the present study

To get an accurate result from the numerical analysis, the selection of an appropriate number of total elements in the mesh is the primary essential requirement in the numerical simulation a sensitivity analysis has been carried out.

Outcomes of the sensitivity analysis confirmed that 10,000 elements in the mess were found an appropriate choice for the mesh generated for the reinforced soil retaining wall system.

As per the suggestions laid by FHWA for multi-tiered walls, the range of geogrid reinforcement length in the lower and upper walls should not be less than 0.7 times of the individual wall height for static case restricted up to 1.1 times of the individual wall height [4]. NCMA [5] suggests that the length of reinforcement must not be less than 0.6 times the individual wall height. Therefore in this study the variation of reinforcement length ranges from 0.5 to 1.2 which covers both the criterion laid by FHWA and NCMA.

In the present study, the ratio of the reinforcement to the height of the wall (L/H ratio) is varied from 0.5 to 1.2 at an interval of 0.2 units. The variation of L/H ratio has intentionally been considered for the cases L/H < 0.7 and L/H > 1.1, to have an insight into the generation of failure surfaces in the reinforced wall for the cases when reinforcing length is either insufficient or more than the required length.

The stability assessment of reinforced retaining wall for the case of conventional and two-tier under seismic loading is carried out for a range of horizontal seismic acceleration coefficient, kh = 0.12, 0.24 and 0.36 and compared with the non-seismic case, i.e. kh = 0. Failure modes of the wall and their transition from one mode to another mode of failure due to the variation in the geogrid length configuration and horizontal seismic acceleration have been analyzed and presented in the next section.

3 Results and discussion

From the numerical analysis carried out in the present study, the factor of safety of various wall systems is obtained by the shear strength reduction method and discussed in the following section.

3.1 Effect of variation of the horizontal seismic acceleration coefficient (kh)

The tiered wall system experiences some significant variations in FOS values due to the change in the horizontal seismic acceleration coefficient (kh). Figure 3 demonstrates the variation of FOS w.r.t various horizontal seismic acceleration coefficients (kh). As suggested by FHWA [4], for a safely designed wall system, the FOS value must not be lesser than 1.50, where the geotechnical parameters are based on limited information; and where the wall/slope contains or supports a structural element. In the two-tiered wall system, the best value of FOS obtained under gravity loading conditions is 1.99, which is far above the required criterion and can be stated as a fine performance of the tiered wall system. With an increase in the kh values, the FOS reduces to 0.92. But, as stated by FHWA, for seismic loading conditions, the length of reinforcement must be greater than or equal to 1.0H, so at the highest value of horizontal seismic acceleration coefficient, kh = 0.36, the L/H ratios falling under this criteria, i.e. L/H = 1.0, and 1.2, provide satisfactory values of FOS as 1.52 and 1.53 respectively, thus making this design safe and serviceable. The single-tiered wall system with a total height of 12 m fails miserably in providing the required FOS, which is 1.031, barely crossing the criterion for a safely designed wall. Again, as the kh value increases from zero to 0.36, a drastic fall in FOS value from 1.03 to 0.44 is noted, thus depicting the inefficiency of the tall wall under seismic loading conditions. Overall a hike of 47% in FOS values is registered on comparing the analysis of single-tier and two-tiered walls. Here, the two-tiered wall system emerges as a suitable alternative to the monolithic tall wall system. Hence, it can be suggested that if the need arises to erect a tall wall under seismic loading conditions, a two-tiered wall system is the most convenient substitute.

Fig. 3
figure 3

Effect of variation of the horizontal seismic acceleration coefficient (kh) in two tiered wall system

3.2 Effect of the variation of reinforcement length

Figure 4 shows a graphical representation of the effect of reinforcement length on the FOS of the two-tiered wall system. It is observed that an increment in the reinforcement length agrees to the increased stability of the wall system. The FOS values are much higher when suitable and sufficient length of reinforcement is provided. The stability of the wall increases by 24% and 40% under gravity loading conditions and seismic loading conditions respectively, as the reinforcement length is increased from 0.5 to 1.2. Although the increased kh values inversely affect the performance of the MSE wall, yet the FOS values are adequate to construct a durable structure. A comparison of the optimum L/H ratio for various horizontal ground acceleration coefficient level for conventional and two-tier MSE retaining walls is presented in Table 2.

Fig. 4
figure 4

Effect of variation of reinforcement length in two tiered wall system

Table 2 Comparison of the optimum L/H ratio for various horizontal ground acceleration coefficient level for conventional and two-tier MSE retaining walls

3.3 Potential failure planes

The critical failure planes which were observed under gravity loading and seismic loading are presented in Figs. 5 and 6 for single-tiered and two-tiered walls, respectively. In the case of a single-tier wall, the observed critical failure plane originated at the corner of the leveling pad, with a high-stress zone below the leveling pad. This particular behavior may be attributed to the fact that with an increase in the reinforcement length, the overall width of reinforced soil mass increases acting as a single unit. When the whole massive reinforced zone moves laterally away from the backfill, a high stressed zone is generated below the leveling pad. In the case of the two-tiered MSE wall, the critical failure plane propagates from the end of reinforcements provided at the base of the wall. A combined failure plane passes below the walls and meets at the end of the reinforcement layers in each wall, further extending towards the backfill surface. One more prominent effect of change in reinforcement length is observed that with an increase in the length of reinforcement, a clear gap between the end of reinforcement in lower-tier wall and leveling pad of the upper-tier wall gets decreases, which makes them behave like a single unit as mentioned in FHWA. Furthermore, when this clear gap decreases, the upper-tier wall, which is just above the lower tier wall, acts as a static surcharge to the lower wall due to its proximity and subsequently increases the stresses in the bottom portion of the lower tier. This overall scenario creates a single critical failure plane that is being originated just below the leveling pad of the lower tier. Moreover, a curved shear failure zone also can be seen below the leveling pad of the lower tier. At lower reinforcement lengths, critical failure planes are observed at the ends of the reinforcement length encased in the backfill soil, like the previous case (walls under gravity loading). However, a triangular wedge shear failure formation observed in the case of two-tiered MSE walls below the upper tier wall.

Fig. 5
figure 5

General propagation of failure plane observed in single tiered wall system

Fig. 6
figure 6

General propagation of failure plane observed in two tiered wall system

4 Conclusions

The present study observes the stability of the reinforced soil retaining wall and its potential modes of failure with the variation of geogrid length for the conventional and two-tiered MSE retaining walls. It is observed that the soil mass beneath the offset distance does not intersect the failure path in case of tiered MSE retaining wall, thus justifying the fact that after a calculated offset distance the walls exert no influence over each other. Also in the conventional MSE retaining wall, it is noted that with increases in the amplitude of seismicity (seismic ground acceleration coefficient) causes disturbance in the soil below the leveling pad rather than the soil reinforced in between the geogrid, which made the leveling pad to sinks before any failure occurs in the reinforced zone. In the case of two-tiered MSE retaining walls, it is observed that as the seismicity increases the failure pattern shows a more definite wedge-like geometry. The failure begins at the toe and propagates towards the backfill. In conventional MSE retaining wall failure also occurs at the end of the geosynthetic layer further propagating towards the backfill. Moreover, some distinctive conclusions drawn from the study are mentioned as follows:

  1. (1)

    The factor of safety (FOS) values are found to be greater for two-tiered MSE retaining walls compared to a single-tiered MSE wall, registering a rise of around 47% in FOS than conventional MSE retaining walls. Therefore, it is suggested that whenever the need arises due to geological or topographical restraints, it safe and convenient to construct two-tiered MSE retaining walls as an alternative, owing to their benefits.

  2. (2)

    The optimum length of reinforcement required for achieving a satisfactory factor of safety in two-tiered walls is much lesser than the optimum length required for achieving the same FOS in conventional MSE retaining walls. The study suggests an optimum reinforcement length of 0.8H for non-seismic loading conditions and 1.1H for seismic loading conditions for the safe design of the MSE wall. The suggestions so delivered, agrees to the criterion set by FHWA.

  3. (3)

    This study observes that in monolithic walls the failure plane propagates from the toe of the wall and stresses are developed near the toe. With an increase in seismicity, the force on the geosynthetic layer is also increased. The stresses are also developed in between the geosynthetic layer and the backfill. In the case of two-tiered walls, the failure plane propagates from the toe to the backfill in a wedge-like structure. The geosynthetic layer is not much affected.

  4. (4)

    The study also proves the efficiency of the two-tiered MSE walls under seismic loading conditions, as the two-tiered wall system performs better than the single-tiered wall at the highest level of seismic excitation, still comfortably crossing the given criterion, therefore suggesting the construction of two-tiered wall system under seismic loading conditions.