Detection of cracks in structures using modal test data

https://doi.org/10.1016/0013-7944(92)90227-6Get rights and content

Abstract

A nondestructive evaluation procedure is presented for identifying a crack in a structure using modal test data. The structure is discretized into a set of elements and the crack is assumed to be located within one of the elements. Measured vibration frequencies and mode shapes are used in an identification process to identify the cracked element based on a simple reduced stiffness model. Static deflection analyses of the structure with and without a crack are performed and a strain energy equilibrium equation is constructed for determining the size of the crack. The detection of a crack on a damaged beam is used to illustrate the applications of the proposed procedure. The present procedure is general and can be easily extended to complex structures with multiple cracks.

References (11)

There are more references available in the full text version of this article.

Cited by (122)

  • A novel method for single and multiple damage detection in beams using relative natural frequency changes

    2019, Mechanical Systems and Signal Processing
    Citation Excerpt :

    In contrast, natural frequencies are easily measured using a single sensor at any accessible point in the structure (except for a node of any particular mode of vibration) and can be monitored with superior accuracy and reproducibility [8,9]. Thus, natural frequency-based damage detection has been presented in many studies [10–34]. Among these, some attempts to detect single damage in beam-like structures are as follows.

  • Dynamic characteristic analysis of cracked cantilever beams under different crack types

    2017, Engineering Failure Analysis
    Citation Excerpt :

    According to the existing literatures [10,11,31–34], two types of crack models are generally used in the previous study: open crack models [35,36] and breathing crack models [37–40]. Based on the open crack models, most researchers [29,30] estimated the presence of the crack by monitoring the frequency changes, which was effective for detecting large cracks. Nevertheless, natural frequency changes are not sensitive to small cracks, i.e., this monitoring method has its limitation [19,24].

View all citing articles on Scopus