Tension, compression, and bending of superelastic shape memory alloy tubes

https://doi.org/10.1016/j.jmps.2012.12.012Get rights and content

Abstract

While many uniaxial tension experiments of shape memory alloys (SMAs) have been published in the literature, relatively few experimental studies address their behavior in compression or bending, despite the prevalence of this latter deformation mode in applications. In this study, superelastic NiTi tubes from a single lot of material were characterized in tension, compression, and pure bending, which allowed us to make direct comparisons between the deformation modes for the first time. Custom built fixtures were used to overcome some long-standing experimental difficulties with performing well-controlled loading and accurate measurements during uniaxial compression (avoiding buckling) and large-rotation bending. In all experiments, the isothermal, global, mechanical responses were measured, and stereo digital image correlation (DIC) was used to measure the evolution of the strain fields on the tube's outer surface.

As is characteristic of textured NiTi, our tubes exhibited significant tension–compression asymmetry in their uniaxial responses. Stress-induced transformations in tension exhibited flat force plateaus accompanied by strain localization and propagation. No such localization, however, was observed in compression, and the stress “plateaus” during compression always maintained a positive tangent modulus. While our uniaxial results are similar to the observations of previous researchers, the DIC strain measurements provided details of localized strain behavior with more clarity and allowed more quantitative measurements to be made. Consistent with the tension–compression asymmetry, our bending experiments showed a significant shift of the neutral axis towards the compression side. Furthermore, the tube exhibited strain localization on the tension side, but no localization on the compression side during bending. This is a new observation that has not been explored before. Detailed analysis of the strain distribution across the tube diameter revealed that the traditional assumption of elementary beam theory, that plane sections remain plane, does not hold. Yet when the strain was averaged over a few diameters of axial length, the tensile and compressive responses input into elementary beam theory predicted the global bending response with reasonable accuracy. While it is encouraging that a simple model could predict the moment–curvature response, we recommend that beam theory be used with caution. The averaged strain field can under/over predict local strains by as much as two-fold due to the localized deformation morphology.

Highlights

► Stereo DIC showed strain localization in tension, but not in compression. ► Custom built fixtures used in compression and large-rotation pure bending tests. ► Plane sections did not remain plane in bending, due to localizations on tension side. ► Tension side strain reached 2% prior to localization (2× higher than in pure tension). ► Despite localizations, beam theory accurately predicted global bending response.

Introduction

Shape memory alloys (SMAs), such as NiTi-based alloys (Nitinol), exhibit two remarkable properties, the shape memory effect and superelasticity. The shape memory effect is the material's ability to recover large mechanically induced strains upon heating above a transition temperature. Superelasticity (or pseudoelasticity) refers to the material's ability, above a transition temperature, to recover large strains isothermally during a mechanical load/unload cycle, usually via a hysteresis loop. The mechanism for superelasticity is a stress induced transformation from austenite (Aust) to martensite (M) during loading and a reverse transformation from M to Aust during unloading. The magnitude of the tensile strain recovery in a Nitinol polycrystal is between 5% and 8% in the low-cycle limit and near 2.5% in the high cycle fatigue limit.

The bending flexibility of SMAs has led to numerous applications in the consumer, civil, transportation, and biomedical engineering sectors. In the consumer sector, superelastic SMAs are used for their bending compliance in eyeglass frames, clothing, headphone headbands, and rugged cell phone antennas (Humbeeck, 1999). SMAs are being explored for vibration damping of civil engineering structures, using the superelastic hysteresis in bending (Dolce and Cardone, 2005, Choi et al., 2009). In recent years, SMAs have been extensively used in biomedical devices, where the strong trend towards minimally invasive surgery in medicine is often enabled by superelastic SMAs (Duerig et al., 1999). Self-expanding stents and stent grafts comprise the largest fraction of existing SMA biomedical applications. These devices are often laser cut from NiTi tubes into a series of crowns and struts, which are locally bent to fit the stent inside a catheter. The catheter delivers the stent to the desired location in the body, where it expands and scaffolds the circumference of a tubular lumen. Other SMA bending examples include catheter guidewires, inferior vena cava filters, tissue ablation devices, retrieval baskets, birth control devices, endoscopes, intra-aortic balloon pumps, and biopsy forceps. In dentistry, superelastic SMAs are used as pretensioned orthodontic wires and root canal files that must bend to accommodate tortuous crevices (Duerig et al., 1999, Morgan, 2004).

Despite the myriad of applications that employ superelastic SMA in bending, and despite the number of SMA bending models (we found 13) (Atanacković and Achenbach, 1989, Thier et al., 1991, Pelton et al., 1994, Plietsch et al., 1994, Berg, 1995b, Auricchio and Sacco, 1997, Raniecki et al., 2001, Rejzner et al., 2002, Purohit and Bhattacharya, 2002, Liew et al., 2004, Rajagopal and Srinivasa, 2005, Buratti, 2005, De la Flor et al., 2010), few careful pure-bending experiments exist in the literature. Traditional 4-point bending fixtures operate under the assumptions of small beam displacements and rotations, which are easily violated when used with slender SMA specimens. Under large displacements, undesirable axial loads tend to develop due to the support constraints. Also, curvature measurements are usually inferred from grip displacements or rotations. Measuring deformation from the grips is problematic with superelastic SMAs, since they frequently transform to martensite prematurely inside grips where stress concentrations exist. This causes grip slippage that makes the deformation measurement inaccurate, and it tends to mask any stress peaks associated with the onset of transformation. In effect, the very bending compliance that makes SMAs attractive for applications also creates experimental difficulties.

A number of researchers have built custom devices to apply pure bending moments to SMA wires with negligible shear and axial loads, but each study has certain limitations. Berg (1995a) performed one of the first pure bending studies on SMA wires in the published literature. Berg's work is notable because he bent his specimens roughly twice as far as other researchers, and he used an optical microscope to measure the curvature (κ) rather than relying on the grip rotation. In Berg's fixture the bending moment (M) was applied by hanging weights, resulting in a moment-controlled experiment. Unfortunately, this control mode was unstable when dM/dκ was close to zero, so gaps exist in Berg's data when this occurred. Furthermore, it is well known that the strain rate (especially in uniaxial tension) has a significant impact on the stress–strain response during the AM and MA transformation (e.g. Chang et al., 2006). Consequently, the bending response depends on the curvature rate, but as Berg acknowledged, his fixture had little control over this quantity. In other work, Bundara et al. (2000) also constructed a custom pure bending fixture, where the moment was applied to SMA wires by hanging weights. The moment curvature relation they measured was not as flat as Berg's, so they were able to capture more data points, but the strain rate still was not controlled. Rejzner et al. (2002) avoided this problem by building a displacement-controlled custom pure bending fixture that integrated directly into a load frame, but this design suffered from friction and imparted a small axial load on the specimen. The axial load was considered negligible by the authors and a friction correction was made, but the method was somewhat unclear to us. Furthermore both Bundara et al. (2000) and Rejzner et al. (2002) measured the curvature from the rotation of the grips, and bent their specimens roughly half as far as Berg, such that the outer fibers did not fully transform to martensite.

In this study, we sought to combine some of the best features of the previous studies and add new measurement capabilities.

  • 1.

    Instead of wires, NiTi tubes with a larger outer diameter were used to accommodate large bending deformations without requiring an extremely small radius of curvature. Although not used in the experiments shown here, this also allowed us to flow fluid within the tube to perform experiments at various temperatures while leaving the outer specimen surface unobscured for infrared or optical imaging (see Churchill, 2010).

  • 2.

    A custom pure bending fixture was built and integrated into a tensile testing machine, facilitating rotation-controlled experiments under large displacements and rotations.

  • 3.

    Unlike previous studies, the tube specimens from the same material lot were also characterized in uniaxial tension and compression to better quantify the tension/compression asymmetry, identify its implications for bending, and to assess whether uniaxial data could be used to predict the tube's pure bending response.

  • 4.

    Stereo digital image correlation (DIC) was used during all experiments to measure the deformation field of the tube specimens, which provided new information not found in the previous studies. DIC is a non-contact optical method used to measure full-field surface displacements of an object by tracking the specular pattern on the surface of a specimen (Sutton et al., 2009).

A further complicating issue for experiments on NiTi specimens is the possibility of strain localization during phase transformation. In pure tension, textured NiTi is known to exhibit strain localization and propagation during certain unstable portions of the superelastic response, and this has now been widely studied, at least at the macroscopic level. In NiTi wires, localization creates propagating necks along the specimen length (Lüders-like deformation) that are responsible for the distinct stress plateaus observed during stress-induced AM transformations at sufficiently slow loading rates (Shaw and Kyriakides, 1995, Iadicola and Shaw, 2002b, Chang et al., 2006). In thin strip (polycrystalline) NiTi specimens, localization manifests as angled fronts, sometimes with finer criss-crossing fingers, that propagate during portions of stress-induced transformations (Shaw and Kyriakides, 1997, Shaw and Kyriakides, 1998). In NiTi tube specimens, transformation front patterns are helical in certain cases, and macroscopically cylindrical in other cases, both of which were first extensively studied using optical photographs (Li and Sun, 2002, Ng and Sun, 2006, Feng and Sun, 2006). The helical patterns were later quantitatively measured using two-dimensional DIC (Favier et al., 2007). Perry et al. (2007) noted the occurrence of localized transformation during bending of a NiTi tube, but did not investigate further. In addition, the following are a few notable efforts to experimentally address the lattice-level details associated with strain localization. Brinson et al. (2004) used optical microscopy with an interference filter to observe the evolution of martensite in isolated grains prior to, during, and after localization during tensile testing of thin NiTi strips. Mao et al. (2010) used electron backscatter diffraction on NiTi tubes to measure the distribution of grain orientations. Schmahl et al. (2004), Hasan et al. (2008), and Young et al. (2010) performed synchrotron X-ray diffraction to measure martensite phase fractions and elastic lattice strains on either side of a transformation front in NiTi cold-rolled bars and fine grained wires during tension. Mehta et al. (2007) also collected synchrotron X-ray diffraction data while bending stent ligaments (annealed), and they highlighted certain untransformed regions that were not captured by their finite element model.

The implications of strain localization during phase transformation on bending behavior are largely unknown. Accordingly, our aim is to quantify the evolution of macroscopic strain fields and to connect the different deformation modes of tension, compression, and bending. We have not attempted diffraction experiments, similar to those mentioned above, to directly link the crystal lattice-level to the macroscopic behavior, although that would be a worthwhile, if challenging, endeavor. As will be shown, the macroscopic behavior is already rich enough to warrant its own study. For this purpose, we found stereo DIC particularly useful to provide more quantitative and higher resolution measurements than shown previously, leading to a clearer understanding of the macroscopic strain fields across these related modes. To our knowledge compression and bending of NiTi have not been studied before using DIC. DIC provided accurate local strain measurement in the specimen gage length without the need to resort solely to grip displacements or rotations. DIC clearly showed when strain localization did, or did not, occur. Furthermore, DIC allowed us to directly measure the evolution of the neutral strain axis for the first time during NiTi bending.

The heterogeneous nature of the bending strain fields also raises the question whether pure tension and pure compression responses can be used in classical beam theory to accurately predict a NiTi beam's moment–curvature response. Classical Euler–Bernoulli bending kinematics assumes a linear strain profile across the cross section, but as will be shown in Section 5, this does not hold true for bending of superelastic NiTi. Thus, elementary beam theory would seem to be invalid for this material, yet we show it can still be used in certain circumstances. The addition of uniaxial tension and compression data on material specimens from the same lot allowed us to directly compare these data sets with our bending data and to address when (and when not) to use elementary beam theory.

Section snippets

Materials and specimen preparation

The material studied was cold-drawn, slightly Ni-rich NiTi tube from Memry Corporation (P/N 10130W, Lot # 957152). The outer diameter and inner diameter were measured as D=2C=3.176mm (0.125 in) and 2.540 mm (0.100 in), respectively, which corresponds to an outer diameter to thickness ratio of D/H=10. Differential scanning calorimetry (DSC), using a Q2000 DSC (TA Instruments) at a scan rate of T˙=±10°C/min, was performed to characterize the transformation temperatures. The DSC specimen was prepared

Experimental setups

3.1 Tension and compression setups, 3.2 Bending setup describe the setups for uniaxial tension, uniaxial compression, and pure-bending experiments. All experiments were performed in room temperature air. Six experiments, two of each type, will be presented in the following sections, and Table 1 provides a summary of specimen gage lengths and loading rates. Experiments are identified by T1, T2, C1, C2, B1, and B2, denoting the type of experiment by the letter and the number denoting the first or

Tension and compression experiments

The mechanical responses of the tube specimens were first characterized in uniaxial tension and compression at nearly isothermal elongation rates in room temperature air. Here, we present uniaxial experiments for later comparison to the room temperature bending response of the tube. A more comprehensive set of experiments on similar tubes at various temperatures and rates can be found in Churchill (2010)4

Bending experiments

In this section, we present two bending experiments (B1 and B2) in room temperature air, each performed on new superelastic tube specimens cut from the same manufacturing lot used in the tension and compression experiments. The setup used 4-point (pure) bending as described in Section 3.2, and specimen dimensions were given in Table 1. The end-rotations were controlled at constant, slow rates in both experiments.

Before presenting the experimental bending results and analysis, the implications

Summary and conclusions

Bending is a fundamental deformation mode of practical importance for superelastic SMAs, but there are few pure bending experiments in the literature, and none that are directly compared to pure tension and compression responses on the same material. We performed isothermal experiments on superelastic NiTi tubes in tension, compression, and large rotation, pure bending using custom-designed fixturing and stereo DIC to quantify the local strain field and eliminate grip effects. The important

Acknowledgments

We gratefully acknowledge the financial support for this work, provided by General Motors Company (through the GM/UM Collaborative Research Laboratory in Smart Materials and Structures), the National Science Foundation (Grant CMMI-0727331), and the US Department of Energy, Office of Basic Energy Sciences (Contract no. DE-SC0003996 monitored by Dr. John Vetrano). Our thanks go Prof. Kenneth Gall (Georgia Institute of Technology), Jeff Tyber (Tyber Medical LLC), and Hans Jürgen Maier (University

References (56)

  • Z.Q. Li et al.

    The initiation and growth of macroscopic martensite band in nano-grained NiTi microtube under tension

    Int. J. Plasticity

    (2002)
  • K. Liew et al.

    Analysis of the pseudoelastic behavior of a SMA beam by the element-free Galerkin method

    Eng. Anal. Boundary Elem.

    (2004)
  • S. Mao et al.

    EBSD studies of the stress-induced B2–B19'martensitic transformation in NiTi tubes under uniaxial tension and compression

    Acta Mater.

    (2010)
  • O. Matsumoto et al.

    Crystallography of martensitic transformation in Ti–Ni single crystals

    Acta Metall.

    (1987)
  • N. Morgan

    Medical shape memory alloy applications—the market and its products

    Mater. Sci. Eng. A

    (2004)
  • K.L. Ng et al.

    Stress-induced phase transformation and detwinning in NiTi polycrystalline shape memory alloy tubes

    Mech. Mater.

    (2006)
  • P. Purohit et al.

    On beams made of a phase-transforming material

    Int. J. Solids Struct.

    (2002)
  • B. Raniecki et al.

    Anatomization of hysteresis loops in pure bending of ideal pseudoelastic SMA beams

    Int. J. Mech. Sci.

    (2001)
  • J. Rejzner et al.

    Pseudoelastic behaviour of shape memory alloy beams under pure bendingexperiments and modelling

    Int. J. Mech. Sci.

    (2002)
  • W. Schmahl et al.

    Investigation of the phase evolution in a super-elastic NiTi shape memory alloy (5.07 at%) Ni under extensional load with synchrotron radiation

    Mater. Sci. Eng.A

    (2004)
  • J.A. Shaw et al.

    Thermomechanical aspects of NiTi

    J. Mech. Phys. Solids

    (1995)
  • J.A. Shaw et al.

    On the nucleation and propagation of phase transformation fronts in a NiTi alloy

    Acta Mater.

    (1997)
  • M. Young et al.

    Phase volume fractions and strain measurements in an ultrafine-grained NiTi shape-memory alloy during tensile loading

    Acta Mater.

    (2010)
  • Adler, P.H., Allen, J., J., L., Francis, R., 2007. Martensite transformations and fatigue behavior of Nitinol. J. ASTM...
  • T. Atanacković et al.

    Moment–curvature relations for a pseudoelastic beam

    Continuum Mech. Thermodyn.

    (1989)
  • F. Auricchio et al.

    A superelastic shape-memory-alloy beam model

    J. Intelligent Mater. Syst. Struct.

    (1997)
  • B. Berg

    Bending of superelastic wires, Part Iexperimental aspects

    J. Appl. Mech.

    (1995)
  • B. Berg

    Bending of superelastic wires, Part IIapplication to three-point bending

    J. Appl. Mech.

    (1995)
  • Cited by (0)