High-transition-temperature superconducting quantum interference devices

D. Koelle, R. Kleiner, F. Ludwig, E. Dantsker, and John Clarke
Rev. Mod. Phys. 71, 631 – Published 1 April 1999
PDFExport Citation

Abstract

The advent of high-Tc superconductors gave great impetus to the development of thin-film superconducting quantum interference devices (SQUIDs) for operation at temperatures up to the boiling point of liquid nitrogen, 77 K. The spectral density of the white flux noise can be calculated analytically for rf SQUIDs and by computer simulation for dc SQUIDs; however, observed noise spectral densities are typically an order of magnitude higher. Low-frequency 1/f noise from thermally activated vortex motion is a much bigger issue in high-Tc SQUIDs at 77 K than in low-Tc SQUIDs because of the low flux-pinning energies in high-Tc superconductors. The magnitude of the noise depends strongly on the quality of the thin films, and much effort has been expended to improve techniques for depositing YBa2Cu3O7x (YBCO) on lattice-matched single-crystal substrates. Substantial effort has also been invested in the development of new types of Josephson junctions, of which grain-boundary junctions are the most widely used in SQUIDs. Appropriate electronic read-out schemes largely eliminate 1/f noise from fluctuations in the junction critical current in both rf and dc SQUIDs. Typical levels of white flux noise are a few μΦ0Hz1/2 (Φ0 is the flux quantum). Magnetometers—consisting of a superconducting flux transformer coupled to a SQUID—achieve a white magnetic-field noise as low as 10 fT Hz1/2, increasing to typically 30 fT Hz1/2 at 1 Hz. When these devices are operated in an unshielded environment, it is important to minimize the motion of trapped vortices and induced supercurrents, which can greatly increase the 1/f noise. The ambient noise is far greater than the intrinsic noise of the devices, but can be substantially reduced by various gradiometer configurations. There is now considerable effort to apply high-Tc SQUIDs in magnetocardiology, nondestructive evaluation, microscopy, and geophysics.

    DOI:https://doi.org/10.1103/RevModPhys.71.631

    ©1999 American Physical Society

    Authors & Affiliations

    D. Koelle

    • II. Physikalisches Institut, Lehrstuhl für Angewandte Physik, Universität zu Köln, D-50937 Köln, Germany

    R. Kleiner

    • Physikalisches Institut III, Universität Erlangen-Nürnberg, D-91058 Erlangen, Germany

    F. Ludwig

    • Physikalisch-Technische Bundesanstalt, Section Cryosensors, D-10587 Berlin, Germany

    E. Dantsker and John Clarke

    • Physics Department, University of California, Berkeley, and Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720

    References (Subscription Required)

    Click to Expand
    Issue

    Vol. 71, Iss. 3 — April - June 1999

    Reuse & Permissions
    Access Options
    Author publication services for translation and copyediting assistance advertisement

    Authorization Required


    ×
    ×

    Images

    ×

    Sign up to receive regular email alerts from Reviews of Modern Physics

    Log In

    Cancel
    ×

    Search


    Article Lookup

    Paste a citation or DOI

    Enter a citation
    ×