To read this content please select one of the options below:

Effect of inhibitor concentration and hydrodynamic conditions on the inhibitive behaviour of combinations of sodium silicate and HEDP for corrosion control in carbon steel water transmission pipes

Mobin Salasi (Corrosion Laboratory, Department of Materials Engineering, Tarbiat Modares University, Tehran, Iran)
Taghi Shahrabi (Corrosion Laboratory, Department of Materials Engineering, Tarbiat Modares University, Tehran, Iran)
Emad Roayaei (Research and Development Directorate, National Iranian Oil Company, Tehran, Iran)

Anti-Corrosion Methods and Materials

ISSN: 0003-5599

Article publication date: 27 March 2007

735

Abstract

Purpose

To study and compare the inhibition effects of eco‐friendly inhibitors of sodium silicate and 1‐hydroxyethylidene 1,1 diphosphonic acid (HEDP) in corrosion control and prevention of soft water discolouration (red water) in carbon steel pipelines.

Design/methodology/approach

Electrochemical impedance and Tafel polarization measurements were used to study corrosion inhibition properties. The experiments were carried out under different concentration ratios of inhibitors. Different hydrodynamic conditions were applied to simulate pipeline fluid flow. Scanning electron microscopy (SEM) and EDAX analysis were used for surface studies.

Findings

It was observed that corrosion inhibitor combinations under static conditions showed synergistic effects at low concentrations. The inhibition efficiency and synergistic behaviours of inhibitors were enhanced as the electrolyte turbulence was increased. In addition, the inhibitor concentration value required to reach maximum inhibition decreased. It was found that at 20 ppm sodium silicate and 5 ppm HEDP, co‐inhibition efficiencies increased significantly to more than 90 per cent and the corrosion rate decreased far below 1 mpy as the electrode rotational speed was increased. Surface studies using SEM revealed the formation of a compact and uniform film of co‐inhibitors.

Practical implications

The results of this paper can be used for the development of effective, non‐toxic and economically attractive corrosion inhibitor formulations for soft water transmission pipelines.

Originality/value

The observed synergistic behaviour can be due to the incorporation of the silicate gel‐like network through organic phosphorous bonds. The hydrodynamic condition of the electrolyte leads to enhancement of inhibition efficiency, which indicates that the corrosion inhibition was mass transfer controlled.

Keywords

Citation

Salasi, M., Shahrabi, T. and Roayaei, E. (2007), "Effect of inhibitor concentration and hydrodynamic conditions on the inhibitive behaviour of combinations of sodium silicate and HEDP for corrosion control in carbon steel water transmission pipes", Anti-Corrosion Methods and Materials, Vol. 54 No. 2, pp. 82-92. https://doi.org/10.1108/00035590710733575