GLUCOSE DETECTION IN BLOOD USING NEAR-INFRARED SPECTROSCOPY: SIGNIFICANT WAVELENGTH FOR GLUCOSE DETECTION

Authors

  • Intan Maisarah Abd Rahim Department of Control & Mechatronic, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Herlina Abdul Rahim Department of Control & Mechatronic, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Rashidah Ghazali Department of Control & Mechatronic, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Ruhaizan Ismail Department of Control & Mechatronic, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
  • Julia Omar Department of Chemical Pathology, Hospital Universiti Sains Malaysia (HUSM) Kubang Kerian, 16150, Kubang Kerian, Kelantan, Malaysia

DOI:

https://doi.org/10.11113/jt.v78.9424

Keywords:

Near-infrared (NIR), blood glucose, non-invasive, wavelength

Abstract

World Health Organization (WHO) stated in 2004, about 347 million people suffered from diabetes and from this statistic, about 3.4 million died from the complication of kidney failure, heart attack, body part amputation and adequately reported suffered from blindness. There are several non-invasive techniques in measuring the blood glucose level developed nowadays and among the popular technique is the near-infrared (NIR) measurement, ultrasonic sensor implementation, multisensory systems, absorbance of transmittance, bio-impedance, voltage intensity, and thermography. Among these techniques, there are several approaches that displayed a lot of potential; nonetheless some of them have produced unsatisfying results. The NIR technique has been applied in some of previous research, however the wavelength used vary for different researcher. There are several points of views on the significant wavelength range that contains suitable information regarding the peaks of glucose in blood. This paper is focusing on the experimental data collection using the near-infrared spectroscopy technique. This paper furthermore discussing on determine the significant peaks of glucose that is suitable to be used as the indicator of the glucose in blood. The highest significant peaks of blood glucose detected from the range around 1450nm and 1930nm.

References

Trabelsi, E. M. A. A., Boukadoum , M., Fayomi, C. 2010. Blood Glucose Sensor Implant Using Nir Spectroscopy: Preliminary Design Study, In: Microelectron. (Icm), 2010 Int. Conf. On, Cairo, 2010. 176-179.

Ben Mohammadi, L., Klotzbuecher , T., Sigloch S., Welzel , Göddel , K., M., Pieber, T.R., Et Al. 2014. In Vivo Evaluation Of A Chip Based Near Infrared Sensor For Continuous Glucose Monitoring. Biosens. Bioelectron. 53: 99-104.

Chia, K. S., Abdul Rahim, H. Abdul Rahim, R. 2013. Evaluation Of Common Pre-Processing Approaches For Visible (Vis) And Shortwave Near Infrared (Swnir). Biosystems Engineering. 115(1): 1323-1328.

Review, C., Communication, S., Principle, G. 2002. World Medical Association Declaration Of Helsinki. Ethical Principles For Medical Research Involving Human Subjects. Nurs. Ethics. 9: 105-109.

Caduff, A., Mueller, M., Megej, A., Dewarrat, F., Suri, R. E., Klisic, J., Et Al. 2011. Characteristics Of A Multisensor System For Non Invasive Glucose Monitoring With External Validation And Prospective Evaluation. Biosens. Bioelectron. 26: 3794-3800.

So, C. F., Choi, K. S., Chung, J. W. Y., Wong, T. K. S. 2012. An Extension To The Discriminant Analysis Of Near-Infrared Spectra. Med. Eng. Phys. 35: 172-177.

I. Application, Integrity Application. 2013. Http://Www.Integrity-App.Com/ (Accessed January 01, 2014).

Caduff, A., Talary, M. S., Mueller, M., Dewarrat, F., Klisic, Donath, J., M., Et Al. 2009. Non-Invasive Glucose Monitoring In Patients With Type 1 Diabetes: A Multisensor System Combining Sensors For Dielectric And Optical Characterisation Of Skin. Biosens. Bioelectron. 24: 2778-2784.

Miyauchi, Y., Horiguchi, T., Ishizawa, H., Tezuka, S. I., Hara, H. 2010. Basis Examination For Development Of Noninvasive Blood Glucose Measuring Instrument By Near-Infrared Confocal Optical System. Sice Annu. Conf. (Sice). 3427-3429.

Miyauchi , Y., Horiguchi , T., Ishizawa, H., Tezuka , S. I., Hara, H. 2011. Blood Glucose Level Measurement By Confocal Reflection Photodetection System. Sice Annu. Conf. (Sice), 2011 Proc. 2011. 2686-2689.

Anas, M., Syafirah, M. N., Norali, A., Normahira,A. N. 2012. Non-Invasive Blood Glucose Measurement Application Of Near Infrared Optical Measurement. Sustain. Util. Dev. Eng. Technol. (Student), 2012 Ieee Conf. 2012. 258-261.

Nakamachi, E. 2010. Development Of Automatic Operated Blood Sampling System For Portable Type Self-Monitoring Blood Glucose Device. Annu. Int. Conf. Ieee Eng. Med. Biol. Soc. Embc’10. 2010. 335-338.

Amaral, C. F., Brischwein, M., Wolf, B. 2009. Multiparameter Techniques For Non-Invasive Measurement Of Blood Glucose. Sensors Actuators, B Chem. 140: 12-16.

Caduff, A., Hirt , E., Feldman , Y., Ali, Z., Heinemann, L. 2003. First Human Experiments With A Novel Non-Invasive, Non-Optical Continuous Glucose Monitoring System. Biosens. Bioelectron. 19: 209-217

Caduff, A., Dewarrat, F., Talary, M., Stalder, G., Heinemann, L., Feldman, Y. 2006. Non-Invasive Glucose Monitoring In Patients With Diabetes: A Novel System Based On Impedance Spectroscopy. Biosens. Bioelectron. 22: 598-604.

Menon, K. A. U., Hemachandran, D., Kunnath, A. T. 2013. Voltage Intensity Based Non-Invasive Blood Glucose Monitoring. Comput. Commun. Netw. Technol. (Icccnt),2013 Fourth Int. Conf., Tiruchengode. 2013. 1-5.

Li, P., Du, G., Cai, W., Shao, X. 2012. Journal Of Pharmaceutical And Biomedical Analysis Rapid And Nondestructive Analysis Of Pharmaceutical Products Using Near-Infrared Diffuse Reflectance Spectroscopy. J. Pharm. Biomed. Anal. 70: 288-294.

Jiang, Y. Hu, X., Zhang, L., Fan, J., Wu, W. 2013. Construction Of Near-Infrared Photonic Crystal Glucose-Sensing Materials For Ratiometric Sensing Of Glucose In Tears. Biosens. Bioelectron. 48: 94-99.

Li, Q.-B., Li, L.-N., Zhang, G.-J. 2010. A Nonlinear Model For Calibration Of Blood Glucose Noninvasive Measurement Using Near Infrared Spectroscopy. Infrared Phys. Technol. 53: 410-417.

Khan, F., Pickup, J. C. 2013. Near-Infrared Fluorescence Glucose Sensing Based On Glucose/Galactose-Binding Protein Coupled To 651-Blue Oxazine. Biochem. Biophys. Res. Commun. 438: 488-492.

Yeh, S. J.,Hanna, C. F., Khalil, O. S. 2003. Monitoring Blood Glucose Changes In Cutaneous Tissue By Temperature-Modulated Localized Reflectance Measurements. Clin. Chem. 49: 924-934.

Yoshinari, H., Ishizawa, H., Fukuda, M., Tokutake, S. 2012. Non-Invasive Self Monitoring Of Blood Glucose System Using Near-Infrared Spectroscopy. Sice Annual Conference (Sice), 2012 Proceedings Of Akita, 2012. 1852-1854.

Chuah, Z.-M., Paramesran, R., Thambiratnam , K., S.-Poh, C. 2010. A Two-Level Partial Least Squares System For Non-Invasive Blood Glucose Concentration Prediction. Chemom. Intell. Lab. Syst. 104: 347-351.

Abdalsalam, O. S., Osman, A. K. M., Abd-Alhadi, R. M., Alshmaa, S. D. 2013. Design Of Simple Noninvasive Glucose Measuring Device. Comput. Electr. Electron. Eng. (Icceee), 2013 Int. Conf. 2013. 216-219.

Neves, A. C. D. O., De Araújo, A. A., Silva, B. L., Valderrama, P., Março, P. H., De Lima, K. M. G. 2012. Near Infrared Spectroscopy And Multivariate Calibration For Simultaneous Determination Of Glucose, Triglycerides And High-Density Lipoprotein In Animal Plasma. J. Pharm. Biomed. Anal. 66: 252-257.

Zhou, Y., Zheng, C., Cao, H., Li, X., Sha, J. 2012. Measurement Of Hemoglobin In Whole Blood Using A Partial Least Squares Regression Model With Selected Second Derivative Near Infrared Transmission Spectral Signals. Biochem. Biophys. Res. Commun. 420: 205-209.

Tenhunen, J., Kopola, H., Myllyla, R. 1998 Non-Invasive Glucose Measuremnt Based On Selective Near Infrared Absorption; Requirement On Instrumentation And Spectral Range. Measurement. 24: 173-177.

Pleitez, M., Von Lilienfeld-Toal, H., Mäntele, W. 2012. Infrared Spectroscopic Analysis Of Human Interstitial Fluid In Vitro And In Vivo Using FT-IR Spectroscopy And Pulsed Quantum Cascade Lasers (QCL): Establishing A New Approach To Non Invasive Glucose Measurement. Spectrochim. Acta - Part A Mol. Biomol. Spectrosc. 85: 61-65.

Kramer, K. E., Small, G. W. 2007. Robust Absorbance Computations In The Analysis Of Glucose By Near-Infrared Spectroscopy. Vib. Spectrosc. 43: 440-446.

Mueller, M., Grunze, M., Leiter, E. H., Reifsnyder, P. C., Klueh, U., Kreutzer, D. 2009. Non-Invasive Glucose Measurements In Mice Using Mid-Infrared Emission Spectroscopy. Sensors Actuators, B Chem. 142: 502-508.

Wan, B., Small, G. W., 2010. Wavelet Analysis Used For Spectral Background Removal In The Determination Of Glucose From Near-Infrared Single-Beam Spectra. Anal. Chim. Acta. 681: 63-70.

Downloads

Published

2016-07-24

Issue

Section

Science and Engineering

How to Cite

GLUCOSE DETECTION IN BLOOD USING NEAR-INFRARED SPECTROSCOPY: SIGNIFICANT WAVELENGTH FOR GLUCOSE DETECTION. (2016). Jurnal Teknologi, 78(7-4). https://doi.org/10.11113/jt.v78.9424