Skip to main content
Log in

Experimental Investigation of the Steady Flow Downstream of the St. Jude Bileaflet Heart Valve: A Comparison Between Laser Doppler Velocimetry and Particle Image Velocimetry Techniques

  • Published:
Annals of Biomedical Engineering Aims and scope Submit manuscript

Abstract

This study investigates turbulent flow, based on high Reynolds number, downstream of a prosthetic heart valve using both laser Doppler velocimetry (LDV) and particle image velocimetry (PIV). Until now, LDV has been the more commonly used tool in investigating the flow characteristics associated with mechanical heart valves. The LDV technique allows point by point velocity measurements and provides enough statistical information to quantify turbulent structure. The main drawback of this technique is the time consuming nature of the data acquisition process in order to assess an entire flow field area. Another technique now used in fluid dynamics studies is the PIV measurement technique. This technique allows spatial and temporal measurement of the entire flow field. Using this technique, the instantaneous and average velocity flow fields can be investigated for different positions. This paper presents a comparison of PIV two-dimensional measurements to LDV measurements, performed under steady flow conditions, for a measurement plane parallel to the leaflets of a St. Jude Medical (SJM) bileaflet valve. Comparisons of mean velocity obtained by the two techniques are in good agreement except for where there is instability in the flow. For second moment quantities the comparisons were less agreeable. This suggests that the PIV technique has sufficient temporal and spatial resolution to estimate mean velocity depending on the degree of instability in the flow and also provides sufficient images needed to duplicate mean flow but not for higher moment turbulence quantities such as maximum turbulent shear stress. © 2000 Biomedical Engineering Society.

PAC00: 8719Uv, 4262Be, 8780-y

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  • 1Bruss, K. H., H. Reul, J. van Gilse, and E. Knott. Pressure drop and velocity fields at four mechanical heart valve prostheses: Bjork-Shiley Standard, Bjork-Shiley Concave Convex, Hall-Kaster, and St. Jude. Med. Life Support Syst.1:3-15, 1983.

    Google Scholar 

  • 2Fontaine, A. A., J. T. Ellis, M. T. Healy, J. Hopmeyer, and A. P. Yoganathan. Identification of peak stresses in cardiac prostheses: A comparison of two-dimensional versus three-dimensional principal stress analyses. ASAIO J.42:154-163, 1996.

    Google Scholar 

  • 3Healy, M. T., J. T. Ellis, A. A. Fontaine, C. A. Jarrett, and A. P. Yoganathan. An automated method for analysis and visualization of laser Doppler velocimetry data. Ann. Biomed. Eng.25:335-343, 1997.

    Google Scholar 

  • 4Karatekin, ö., F. Y. Wang, and J. M. Charbonnier. Characterization of a Bluff Body Wake Using LDV and PIV Techniques, Ninth International Symposium Applications of Laser Techniques to Fluid Mechanics. Berlin: Springer, to be published.

  • 5Lim, W. L., Y. T. Chew, T. C. Chew, and H. T. Low. Steady flow dynamics of prosthetic aortic heart valves: A comparative evaluation with PIV techniques. J. Biomech.31:411-421, 1998.

    Google Scholar 

  • 6Lim, W. L., T. C. Yong, C. C. Tuan, and H. T. Low. Steady flow velocity field and turbulent stress mappings downstream of a porcine bioprosthetic aortic valve. Ann. Biomed. Eng.25:86-95, 1997.

    Google Scholar 

  • 7Lourenco, L. M. A Kinetic Model for Gas-Particle Suspension Flow in a Horizontal Duct and its Numerical Implementation, Université Libre de Bruxelles, Doctoral thesis, 1982.

  • 8Munson, B. R., D. F. Young, and T. H. Okiishi. Fundamentals of Fluid Mechanics, 3rd ed. 1998, p. 480.

  • 9Woo, Y. R., and A. P. Yoganathan. In vitro pulsatile flow velocity and turbulence shear stress measurements in the vicinity of mechanical aortic heart valve prostheses. Life Support Syst.3:283-312, 1985.

    Google Scholar 

  • 10Yoganathan, A. P. Cardiovascular Fluid Mechanics: 1. Fluid Dynamics of prosthetic Aortic valves, 2. Use of the Fast Fourier Transform in the Analysis of Cardiovascular Sounds. California Institute of Technology, Ph.D. thesis, 1978.

  • 11Yoganathan, A. P.et al., Bileaflet, tilting disc and porcine aortic valve substitutes: In vitro hydrodynamic characteristics. J. Am. Coll. Cardiol.2:313-320, 1984.

    Google Scholar 

  • 12Yoganathan, A. P., W. H. Corcoran, and E. C. Harrison. In vitro velocity measurements in the near vicinity of aortic valve prostheses. J. Biomech. Eng.12:135-152, 1979.

    Google Scholar 

  • 13Yoganathan, A. P., T. M. Wick, and H. Reul. The Influence of Flow Characteristics of Prosthetic Valves on Thrombus Formation. In Thrombosis, Embolism and Bleeding, 1st ed., London; ICR, 1992, pp.123-148.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Browne, P., Ramuzat, A., Saxena, R. et al. Experimental Investigation of the Steady Flow Downstream of the St. Jude Bileaflet Heart Valve: A Comparison Between Laser Doppler Velocimetry and Particle Image Velocimetry Techniques. Annals of Biomedical Engineering 28, 39–47 (2000). https://doi.org/10.1114/1.252

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1114/1.252

Navigation