1985 Volume 25 Issue 12 Pages 1244-1250
The use of air-atomizing mist nozzle for the secondary cooling of continuous casting machine results in the following advantages over the conventional water spray nozzle: less longitudinal surface cracks and higher temperature of cast slabs, wide control range of cooling, and prevention of nozzle clogging. The air injection to the water spray nozzle is also good for preventing nozzle clogging.
The authors have developed a few types of air-atomizing nozzles and their application techniques, including methods of injection, for the secondary cooling system of the slab casters.
Discussed here are structural and fluidic features of the newly developed mist nozzles and the air-injection type spray nozzle with reference to some technical points concerning the new cooling system and the operational results.