Investigation of Impact Resistance of High-Strength Portland Cement Concrete Containing Steel Fibers

by
Mohammad Mohtasham Moein
1,
Ashkan Saradar
2,
Komeil Rahmati
3,
Arman Hatami Shirkouh
4,
Iman Sadrinejad
5,
Vartenie Aramali
6 and
Moses Karakouzian
7,*
1
Department of Civil Engineering, Allameh Mohaddes Nouri University, Nour 4641859558, Iran
2
Department of Civil Engineering, University of Guilan, Rasht 419961377, Iran
3
Department of Civil Engineering, Somesara Branch, Islamic Azad University, Somesara 4361947496, Iran
4
Department of Civil Engineering, Qazvin Branch, Islamic Azad University, Qazvin 1519534199, Iran
5
Department of Civil Engineering, Ramsar Branch, Islamic Azad University, Ramsar 4487136889, Iran
6
Department of Civil Engineering and Construction Management, California State University, Northridge, LA 91330, USA
7
Department of Civil and Environmental Engineering and Construction, University of Nevada, Las Vegas, NV 89154, USA
*
Author to whom correspondence should be addressed.
Materials 2022, 15(20), 7157; https://doi.org/10.3390/ma15207157
Submission received: 6 September 2022 / Revised: 29 September 2022 / Accepted: 10 October 2022 / Published: 14 October 2022
(This article belongs to the Special Issue Cementitious Materials and High Performance Concrete)

Abstract

:
Impact resistance of Portland cement concrete (PCC) is an essential property in various applications of PCC, such as industrial floors, hydraulic structures, and explosion-proof structures. Steel-fiber-fortified high-strength concrete testing was completed using a drop-weight impact assessment for impact strength. One mix was used to manufacture 320 concrete disc specimens cured in both humid and dry conditions. In addition, 30 cubic and 30 cylindrical specimens were used to evaluate the compressive and indirect tensile strengths. Steel fibers with hooked ends of lengths of 20, 30, and 50 mm were used in the concrete mixtures. Data on material strength were collected from impact testing, including the number of post-first-crack blows (INPBs), first-crack strength, and failure strength. Findings from the results concluded that all the steel fibers improved the mechanical properties of concrete. However, hooked steel fibers were more effective than crimped steel fibers in increasing impact strength, even with a smaller length-to-diameter ratio. Concrete samples containing hybrid fibers (hooked + crimped) also had lower compressive strength than the other fibers. Comparisons and analogies drawn between the test results and the static analyses (Kolmogorov–Smirnov and Kruskal–Wallis) show that the p-value of the analyses indicates a more normal distribution for curing in a humid environment. A significant difference was also observed between the energy absorptions of the reinforced mixtures into steel fibers.

1. Introduction

Concrete is the most used building material, with an annual consumption of well over 25 billion tons [1,2,3,4,5]. The availability of ingredients, ease of casting in any shape, economy, high compressive strength, as well as good durability in various environmental conditions are the factors that make concrete such a versatile construction material [6,7,8,9]. The use of concrete in constructing different structures, such as bridges, high-rise buildings, dams, and nuclear power plants, is inevitable, and as such, the concrete industry has seen remarkable progress in recent years. This progress has led to the development and production of high-strength concrete (HSC) and high-performance concrete (HPC) with desirable properties [10,11]. High-strength concrete has acceptable performance under harsh climates and humid environments due to its low permeability properties, thus decreasing maintenance and repair expenses [12,13,14]. Plain concrete, however, is generally fragile [13], with low tensile strength [15]. Different fibers are often added to concrete to improve the tensile strength, ductility, and toughness properties [1,16]. Generally, fibers can be made from manufactured products such as steel, glass, and synthetics or natural materials such as hemp, jute, and silk [15]. Among the various fibers used in manufacturing fiber-reinforced concrete, significant attention has been devoted to the use of steel fibers. Studies show that the presence of steel fibers can improve the properties of concrete, including increased compressive and tensile strength [17,18,19], thereby increasing energy absorption [17] as well as reducing water absorption by controlling cracks and mitigating them [19].
Concrete impact resistance is an essential property in various applications such as industrial floors, hydraulic structures, and explosion-proof structures. Given that the use of fiber-reinforced concrete in these structures is increasing, it is important to evaluate the impact resistance of concrete using different types of fibers. Among the various methods for assessing the impact strength of concrete, the drop-weight impact test proposed by ACI Committee 544 [20] is the simplest method. In this method, the impact strength of the concrete is evaluated based on the number of blows needed to produce the first crack and failure.
Some factors, such as the test character or the heterogeneous nature of concrete, can cause the impact test results to be highly dispersed [21]. Various studies have, therefore, investigated the statistical and experimental properties of fiber-reinforced concrete’s impact strength using the ACI 544 method. This study evaluates the effects of different curing conditions and different types of fibers, namely, hook and crimped steel fibers, and the impact resistance of fiber-reinforced concrete. Fiber-reinforced concrete mix designs were made and cured in either humid or dry conditions. Then, the drop-weight impact test was conducted, and impact strength parameters were determined for different curing conditions and different types of steel fiber.

2. Research Background

Many researchers have studied the effect of steel fibers on the mechanical properties of different types of concrete. A complete report on the characteristics of consumable steel fibers and the types of tests performed in previous studies is reported in Table 1.
According to Table 1, about 54 papers containing useful information about concrete containing steel fibers were reviewed. The results indicate that investigating the effect of different shapes of steel fibers in concrete and comparing them can be considered for future studies. On the other hand, the length/diameter parameter is one of the most important items regarding steel fibers. According to the investigations, few papers have investigated the different length/diameter ratios in the laboratory and numerical field. The concrete curing environment is also one of the items affecting the mechanical characteristics of concrete, but most of the studies conducted on concrete containing steel fibers against impact strength are ultimately limited to a curing environment. Figure 1 shows the overview of the study process. In the present study, steel fibers are used as an effective factor in increasing the mechanical strength of concrete. Although various studies have been conducted on concrete containing steel fibers, the study of this type of concrete against impact load requires further investigation. Factors such as specimen geometry, fiber type, concrete mixture, nature of the test, and the nonhomogeneous condition of the concrete are very effective in the weight drop test [21,26]. Therefore, the statistical and laboratory investigations of the impact resistance of concrete containing steel fibers can provide clearer performance results for this type of concrete.
Therefore, in this study, in the first stage, a complete study was performed on the research on fiber-containing concrete and information such as concrete type, the shape of steel fibers, fiber length, fiber diameter, the length-to-diameter ratio of fibers, and fiber consumption dose; the mechanical tests performed on concrete are reported in a table. In the next step, to study the effect of the shape and length of fibers, steel fibers in different sizes were used. Additionally, to investigate the effect of curing conditions on the mechanical properties of concrete, two completely different curing environments were planned. After the fabrication and processing of the samples, compressive, tensile, and impact strength tests were used to evaluate mechanical strength. In order to provide clearer results, the results of the experiments were analyzed by statistical analysis. The behavior of concrete under short-duration dynamic loads (such as earthquakes, wind gusts, and machinery) is completely different from the behavior it exhibits under static load conditions. Therefore, the results of the present study can be considered a practical reference for projects that are of high importance, such as hospitals, nuclear power plants, tall buildings, etc. It is expected that the results of this study can provide useful information to civil engineers.

3. Materials and Methods

3.1. Materials

In our study, Portland Cement Type II (Table 2) was added to the concrete mixtures. Silica fume (Table 2) was also considered a mineral pozzolanic material to replace part of the weight of cement. For a coarse aggregate, gravel with a water absorption of 0.8% and the largest nominal grain size of 19 mm was used. For the fine aggregate component, natural sand with a water absorption of 1.3% and a maximum diameter of 4.75 was used. The particle size distributions of the fine and coarse aggregates are shown in Figure 2. The superplasticizer (Table 3) employed in the present study was derived from a basis of polycarboxylate with a specific weight of 1.2 ± 0.05 gr/cm3. The steel fibers utilized during this investigation had a tensile strength of 1140 MPa and were crimped and hooked (Table 4, Figure 3).

3.2. Mixing of Concrete and Casting of the Test Specimens

One concrete mixture with a water-to-binder (W/B) ratio of 0.4 and a cement grade of 450 kg/m3 was designed. The concrete mix proportions are given in Table 5. The concrete mixtures consisted of a control mix with no fiber and four combinations with fibers. The first mixture is called control concrete (R), which has no fibers. In the second mixture (F2), 2 cm crimped fibers were used to make the fiber concrete. Additionally, 3 cm hooked fibers and 5 cm crimped fibers were added to the third (F3) and fourth (F5) mixtures, respectively. Finally, in the fifth blend (F2F3), a combination of 2 cm crimped steel fibers and 3 cm hooked steel fibers was used. The distribution of steel fibers in all the fiber concrete mixtures was 1% by volume [34,71].
Figure 4 shows the results of the slump test of mixtures. For concrete without fibers, the amount of slump was 19 cm, while for other mixes that had steel fibers, a lower amount of slump was obtained. The results of the slump test of the mixtures show that the inclusion of steel fibers reduces the workability of the concrete. The result is confirmed by the study of Atis and Karahan [35].
After conducting the slump test, the concrete mixture was poured into 15 cm cubic molds for the compressive strength test and 30 × 15 cm cylindrical molds for the splitting tensile strength test (Figure 5). After 24 h, the samples were removed from the mold. One set of specimens was cured in humid conditions and another set was cured in a dry environment until they were ready to be tested. According to the ACI 308R-01 standard [72], in order to process the samples in a humid environment, the samples were placed in water at 23 ± 1 °C for 28 days; in order to dry the samples in a dry environment, the samples were placed in a laboratory environment at 25 °C for a 28-day curing period. The number of days was set.
The impact test was conducted in line with the drop-weight measurement recommended by ACI Group 544. As shown in Figure 6, this test consists of repeatedly dropping a hammer weighing 4.54 kg from a height of 457 mm on a steel ball with a radius of 63.5 mm located at the center of the sample’s surface. The strength of the initial crack was obtained by measuring the number of blows that resulted in the initial crack. The failure strength refers to the number of blows required to touch three of the four metal bushes of the impact device by the concrete disc. This test was performed on each type of concrete at 28 days of age on 64 concrete discs (32 disks in a humid environment and 32 disks in a dry environment) with a diameter of 15 cm and a thickness of 6.4 cm, having been cut from 15 × 30 cm cylindrical specimens (Figure 7). Details of the number of specimens and discs used for impact testing are reported in Figure 8.

3.3. Tests

The tests were performed on hardened concrete after a curing period of 28 days. The test specification, the size of the samples, and the standards used are given in Table 6. Moreover, in order to examine the efficiency of the fresh concrete, the slump test was performed on the fresh concrete. Figure 9. shows an overview of the experiments performed in the study. Repeatability (or reliability of re-testing) is a parameter used to describe a change in successive measurements of the same variable under similar conditions over a short period of time. The repeatability index is defined as follows [73,74]:
RI = Σ C V % N a l l
where ΣCV% = is the sum of coefficients of variation percentages and Nall = is the total number of mixtures.
Table 7 shows the results of repeatability testing for previous studies and the current study. Comparing the result indicator RI obtained for the present study with the previous studies shows that the results of the tests are stable and repeatable.

4. Results and Discussion

4.1. Compressive Strength

The 28-day specimens’ compressive strength was determined for humid and dry curing conditions, as shown in Figure 10a. The compressive strength of the specimens varied from 46 to 70 MPa. Figure 10a shows that, regardless of the type of curing, the addition of steel fibers increased the compressive strength of the high-strength concrete. On the other hand, the results showed that using crimped fibers with a longer length-to-diameter ratio resulted in higher compressive strength. Curing the specimens in a humid environment also resulted in higher compressive strength than those cured in a dry environment. This is attributed to the higher degree of hydration. This result was also reported by Bingöl and Tohumcu [82], Razzaghi et al. [83], and Benli et al. [84].
Examining fiber performance in concrete shows that 5 cm corrugated fibers increased the compressive strength of ordinary concrete by an average of 39%, while 3 cm and 2 cm corrugated fibers improved the compressive strength by 33% and 28%, respectively. A comparison of the mixtures’ compressive strengths indicates that the mixture containing 5 cm crimped fibers was 10%, 5%, and 9% stronger, on average, than F2, F3, and F3F2. This may be due to the longer length of the 5 cm wavy fibers compared to other fibers.

4.2. Splitting Tensile Strength

Figure 4b shows the 28-day splitting tensile strength of different concrete samples under both humid and dry curing conditions. The lowest splitting tensile strength was 3.15 MPa for the control concrete and concrete cured in dry conditions. This value increased up to 5.2 MPa for steel fibers and concrete cured in a humid environment. These findings reflect the fact that the tensile strength of the high-strength concrete showed increased values when using steel fibers. On the other hand, the results of Figure 10b show that the 3 cm hooked steel fibers resulted in higher tensile strength than the other fibers. The positive effect of curing in a humid environment compared to a dry environment is displayed in Figure 10b. The studies of Benli et al. [84], Haghighatnejad et al. [85], and Ismail et al. [86] also confirm the result. The addition of 3 cm hook fibers improved the tensile strength of the reference concrete by 19%, whereas 5 and 2 cm crimped fibers provided 8% and 14% improvement in the reference concrete, respectively.

4.3. Impact Strength

For each mixture and curing condition, 32 discs were tested for the drop-weight impact load. The number of blows required for the appearance of the first crack and for the final failure was determined in the tests. The results for the humid and dry curing conditions are given in Table 8. Regarding the statistical study of initial crack strength, fracture strength, and the increase in the number of post-first-crack blows (INPBs), two statistical procedures were chosen: the Kolmogorov–Smirnov and Kruskal–Wallis analyses. The Kolmogorov–Smirnov test examines the probability of whether the observations are normal or not. In this test, a p-value less than 0.05 means that the normal assumption was rejected. On the other hand, the Kruskal–Wallis test compares two or more groups of data. In the Kruskal–Wallis test, there was no significant difference between groups, as the p-value was greater than 0.5 [21].

4.3.1. First Crack Strength

Table 8 shows that the average number of blows needed for the appearance of the first crack was 144 in high-strength control concrete (R) cured in a humid environment. For the same curing conditions, the average number of blows for the first crack of fiber-reinforced concrete specimens of mixtures F2, F3, F5, and F2F3 were 172, 416, 223, and 173, respectively (Figure 11a). The presence of steel fibers in the concrete, therefore, enhanced the number of blows needed for the first crack. This is because the steel fibers reinforce the concrete in three directions, which helps the disk to absorb impact energy. The increased energy absorption capacity could eventually delay the emergence of the first crack [26]. Aghaei et al. [87] also reported an improvement in the concrete’s impact strength by adding steel fibers.
The results given in Table 8 show that high-strength concrete containing 5 cm crimped steel fibers can withstand a higher number of average blows than concrete containing 2 cm crimped steel fibers. This shows the positive effect that fibers with a longer length-to-diameter ratio have on impact strength. Fiber shape, however, also plays a role. The hooked fibers increased the impact strength of the high-strength concrete better than the crimped fibers did, even with a stronger length-to-diameter ratio. The trend observed for the performance of steel fibers in a humid environment is similar to that for curing in dry environments. In dry curing conditions, an average of 123 blows was required to create the first crack in the high-strength control concrete, which increased to 147, 227, 158, and 144 in the fiber-reinforced concretes F2, F3, F5, and F2F3, respectively (Figure 11a). For the mixtures, a 95% confidence interval was obtained on the average resistance of the first crack, which includes the lower and upper bounds (Table 8). This range indicates that there is a 95% chance that the true first-crack resistance is within this range [21,26].
The coefficients of the variation of the first-crack impact strength for mixtures R, F2, F3, F5, and F2F3 in a humid environment were 27%, 33%, 77%, 36%, and 37%, respectively. The corresponding values for dry curing conditions were 29%, 32%, 88%, 41% and 44%, respectively. Thus, the impact strength data shows more dispersion for dry-cured concrete than those cured in humid conditions.
As stated, p-values of less than 0.05, obtained by the Kolmogorov–Smirnov test, indicate that the data are not normally distributed. The normal probability shapes and histograms for different mixtures cured in humid conditions are plotted in Figure 12, Figure 13, Figure 14 and Figure 15. Figure 16, Figure 17, Figure 18 and Figure 19 show the corresponding values for dry curing conditions.
Figure 12a shows the frequency histograms, along with the normal plot, for reference concrete processed in a wet environment, which means that the resistance of the first crack of the reference concrete rarely follows a normal distribution. In addition, Figure 13a shows the normal probability plot of this mix. There is a low curvature plot in the lower half of the straight line that indicates a rarely normal distribution. On the other hand, the normal distribution of results was examined by the Kolmogorov–Smirnov test with a significance level of 0.05 (reported in Table 8). The p-value obtained for the first cracks of the reference concrete in a wet environment was 0.093, which confirms the above claim. Mixtures of F2 and F23 follow the normal distribution in Figure 13b and Figure 15b, respectively, due to the relatively close fit of the normal plot to the histogram (Figure 12b and Figure 14b, respectively) and the almost linear pattern of the data. Additionally, the p-value obtained by the K–S test showed a value greater than 0.15, which confirms their normal distribution. Mixtures of F3 and F5, however, do not follow the normal distribution due to the normal plot’s poor fit, shown in Figure 12c and Figure 14a, respectively, aside from the intensive deviation of the results from the straightforward line (Figure 13c and Figure 15a). The p-value of the K–S test was less than 0.01. Figure 16a and Figure 17a show the normal distribution of reference concrete in a dry environment due to the acceptable fit of the normal plots to the histogram and linear pattern of the data. On the other hand, this mixture’s p-value was equal to 0.141. Mixtures of F3 and F2F3 do not follow the normal distribution due to the poor representation in Figure 16c and Figure 18b as well as the nonlinear pattern in Figure 17c and Figure 19b. In addition, the p-value confirms this result from the K–S test. Finally, the incorporation of F5, according to Figure 18a and Figure 19a, as well as a p-value equal to 0.093, shows a rarely normal distribution. Table 8 confirms that the first-crack impact strengths of concretes F2 and F2F3 cured in a humid environment and those of mixtures R and F2 cured in a dry environment have shown approximately normal distributions.
Table 9 illustrates the comparison of the first-crack strength in the two curing environments against conventional high-strength concrete using the Kruskal–Wallis test. The results show that the first-crack impact strength in a humid environment for mixtures F2, F3, F5, and F2F3 compared to the reference high-strength concrete has p-values of 0.029, 0.000, 0.000, and 0.049, respectively. In addition, the corresponding p-values for dry curing conditions were 0.030, 0.001, 0.021 and 0.321, respectively. This indicates a significant improvement in the first-crack impact strength of high-strength concrete when the steel fibers were introduced separately compared to that of the high-strength control concrete.

4.3.2. Failure Strength

According to the average strength values presented in Table 8, in humid environments, the average failure strength of conventional high-strength concrete is 150 blows. The average failure strength of F2, F3, F5, and F2F3 mixtures are 192, 455, 257, and 200 blows, respectively, indicating the improved failure strength of high-strength concrete with the addition of steel fibers (Figure 11b).
Similarities were observed in the strength of the first crack, the mean blows’ strength at failure, and the high-strength concrete containing 5 cm crimped steel fibers increasing from 2 cm crimped steel fibers. This demonstrates the effective role of a higher length/diameter ratio in increasing the impact strength of the concrete. Hooked fibers, however, have better performance in increasing the concrete’s strength compared to crimped fibers, even with a lower diameter ratio. In a dry environment, the average failure strength of conventional high-strength concrete is 129 blows, and the mean failure strength of F2, F3, F5, and F2F3 mixtures is 158, 237, 173, and 163, respectively (Figure 11b). As with the first-crack strength, a 95% confidence interval on the mean for failure strength was obtained (Table 8). This range indicates that there is a 95% chance that the true failure strength is within this range [21,26].
Therefore, in dry environments, as in humid environments, the addition of steel fibers to high-strength concrete improves failure strength. Average impacts for failure in humid environments compared to dry environments for conventional high-strength concrete were 1.162 times, for concrete containing 2 cm crimped steel fiber 1.215 times, for 3 cm hooked steel fiber 1.919 times, for 5 cm crimped steel fiber 1.485 times, and for fiber composition 1.226 times. Similar to the strength of the first crack, the comparison of the failure strength coefficient of variation in the two environments also shows higher values in dry environments than in humid environments.
Figure 20, Figure 21, Figure 22 and Figure 23 show the histogram shapes and the normal probability of failure strength for humid environments. Additionally, Figure 24, Figure 25, Figure 26 and Figure 27 show the same for failure strength in dry environments. The shapes and results of the Kolmogorov–Smirnov test in Table 8 show the F5, F2, and F2F3 mixtures’ almost normal distribution of failure strength in a humid environment. The distribution of the F2 mixture was also almost normal in a dry environment.
Figure 20a shows the frequency histogram with the normal plot, and Figure 21a shows the normal probability plot for the failure resistance R. Additionally, the p-value of the K–S test, which is equal to 0.068, is the result of a seldom normal distribution for this mixture. Figure 20b and Figure 22a,b, which are related to mixtures of F2, F5, and F2F3, respectively, show a relatively close fit of the normal plot to the histogram. In addition, Figure 21b and Figure 23a,b demonstrate the almost linear pattern of the mixed data. The p-value for mixtures F2, F5, and F2F3 by the K–S test indicates a number greater than 0.15, which confirms the normal distribution of these mixtures. For the F3 mixture, Figure 20c and Figure 21c, plus the p-value (0.087), show that a normal distribution is rare. Reference concrete in a dry environment also rarely shows a normal distribution due to the poor display in Figure 24a and Figure 25a. The p-value for this mixture is equal to 0.075, which confirms its rarely normal distribution. The F2 mixture shows a normal distribution due to the relatively acceptable results of the normal plot with the histogram in Figure 24b, the almost linear pattern of the data in Figure 25b, as well as a p-value greater than 0.15 from the K–S test. Mixtures of F3, F5, and F2F3 do not follow the normal distribution due to poor representation of the fit between the normal plot and the histogram in Figure 21c and Figure 22a,b, respectively. This is also due to the nonlinear pattern in Figure 25c and Figure 27a,b, respectively. The p-value obtained from the K–S test for these mixtures also indicates abnormal distributions.
Table 9 compares the failure strength of two curing environments with the Kruskal–Wallis test against conventional high-strength concrete. The results show that the failure strength of humid environments for F2, F3, F5, and F2F3, with respect to conventional high-strength concrete, have p-values of 0.001, 0.000, 0.000, and 0.001, respectively. In dry environments, the values obtained were 0.003, 0.000, 0.002, and 0.058, respectively.
Figure 28 displays the failure pattern of the control concrete (no steel fibers) and fiber sample concrete under the drop-weight impact test. As expected, non-steel discs exhibited brittle behavior and failed to gain centralized, sudden, and massive cracking (Figure 28a). Additionally, fewer blows were recorded from the time of the first crack to final disc failure. Examination of the crack pattern in the discs containing steel fibers showed multiple and interconnected cracks (Figure 28b). In addition, the separation of particles in the discs and the release of fibers in these types of mixtures were accompanied by the maintenance of matrix integrity. This is due to the bridging properties of the fibers, which can be seen in Figure 28c.

4.3.3. The Frequency of Blows after the Initial Crack

The comparison in Table 8 shows that in humid and dry environments, the average number of blows after the first crack until failure for the high-strength control concrete was six blows. The values for mixtures F2, F3, F5, and F2F3, cured in a humid environment, were 6.5, 3.33, 5.66, and 4.5 times that of the control concrete, respectively. Similarly, the average number of blows after the first crack until failure for mixtures F2, F3, F5, and F2F3, cured in a dry environment, was 1.83, 1.83, 2.5, and 3.16 times that for the control concrete, respectively. This again demonstrates the efficiency of reinforced high-strength concrete with steel fibers. These figures also show that curing in humid environments can improve the number of blows after the first crack in fiber concrete. Table 9 shows the comparison of the INPB in the two curing environments through the Kruskal–Wallis test against the high-strength control concrete. The results show that concrete containing steel fibers in both curing environments significantly increases the frequency of blows following the occurrence of the first crack, which means that the fibers inhibit the propagation of cracks and delay final failure.

4.3.4. Ductility Index and Impact Energy

In the field of impact resistance, in addition to first-crack strength and failure strength, a new term, the ductility index (λ), has been defined by Cao [88]. This index reflects the toughness of concrete discs after cracking [49]. The ductility index is defined as the ratio of the impact energy absorbed by the concrete from crack to failure (NfailNfirst) to the impact energy absorbed by the first visible crack in the concrete (Nfirst). The ductility index (λ) and impact energy are defined by the following formula [49,89]:
λ = N f a i l N f i r s t N f i r s t
E = N f a i l × m g h
where λ = the ductility index, Nfirst = first visual crack, Nfail = ultimate crack, E = impact energy (J), m = mass of hammer, g = gravitation acceleration, and h = height of drop.
The ductility index (λ) for different mixtures in Table 10 shows that the mixtures containing steel fibers have a better performance in increasing the toughness of concrete after cracking. This is due to the bridging property of the steel fibers, which gives the steel fibers an extraordinary ability to absorb higher impact energy after cracking [25,63,90]. The findings obtained in the present research are consistent with previous studies [21,91,92]. According to Table 10, it is observed that the addition of steel fibers significantly increases the impact energy; this process occurs both in the first-crack stage and in the failure stage [13,93]. This indicates that the presence of fibers delays the initiation of the first crack and prevents crack propagation [49]. Additionally, Figure 29 shows a schematic view of impact energy for different mixtures. Comparing the results of mixtures in both environments indicates that the lowest value of impact energy is related to mixtures without fibers (R). Additionally, the F3 mixture shows the highest amount of impact energy in both curing environments.

4.3.5. Prediction of Impact Failure Strength

Prediction equations for fracture strength in humid and dry environments are shown in Table 11, where Np-fail represents the failure strength and Nfirst the first-crack strength according to the regression analysis of the impact strength data. According to the regression analysis, the linear relationship between the strengths at the first crack and failure in concrete specimens in both environments is supported by a suitable correlation coefficient.
The coefficient of determination (R2) of mixtures cured in humid and dry environments is shown in Table 11. Obtaining a coefficient of determination of 0.7 or higher, for most statistical experts, results in a reasonable model [21,94]. Based on the results, the obtained equations can successfully illustrate the relationships between the first-crack strength, the failure of conventional high-strength concrete samples, and the high-strength mixtures armed with steel fibers. The results are confirmed by the studies in Table 12 about the linear relationship between the first and ultimate crack impact resistance. In order to evaluate the prediction models’ accuracy, MAD and MAPE were used [21,26,95]:
M A D = N M N P n
M A P E = 1 n   N M N P N M × 100
MAD represents the mean absolute deviation, and MAPE measures the mean absolute percentage error, where Np is the predicted fracture strength, and NM denotes the failure strength measured. Additionally, n shows the number of samples tested. Table 12 shows the MAD and MAPE values derived from the forecasting models. All mixtures exhibit relatively low MAD and MAPE values in the two environments, and this may contribute to the prediction of failure strength projections with higher accuracy [49].

4.4. Validation of Results

Table 13 shows the results of previous studies. Items such as the type of fiber, the amount of fiber consumption, the process of compressive and tensile strength, the number of blows for the resistance of the first crack and failure, INPB, proposed equations, MAD, MAPE, R2, and p from the Kolmogorov–Smirnov test were collected. The comparison of the results of the present study with the results of previous studies is confirmed.

5. Conclusions

This study statistically analyzes the effect that different types of steel fibers have on the impact strength of high-strength concrete under different curing conditions, and it extracts the following results:
  • The presence of different steel fibers improves the compressive strength by 22% to 40%, and 5 cm corrugated fibers allow the greatest increase in strength. In addition, humid-cured samples have higher compressive strength (up to 12%).
  • The presence of different steel fibers improves the tensile strength by 17% to 60%, and 3 cm hooked-end steel fibers allow the greatest increase in strength. The humid-cured samples also have higher tensile strength (up to 21%).
  • The presence of steel fibers in concrete improves some parameters. For example, the number of blows for first-crack strength, failure strength, and energy absorption increase by 1.194–2.288 times, 1.224–3.033 times, and 1.83–6.5 times, respectively. Fiber shape also had an impact on the strength of the concrete, with the best performance being the 3 cm hooks.
  • The comparison of F2 and F5 shows that taking into account the ratio of length to diameter, the presence of crimped fibers with a higher ratio of length to diameter has a better performance in increasing the strength of the first crack and failure.
  • The relationships obtained in this study indicate a high correlation between first-crack strength and failure strength. Statistical analysis (Kolmogorov–Smirnov and Kruskal–Wallis) also shows a more normal distribution of humid environments and a significant difference in steel-reinforced concrete by p-value.
  • In addition to adding fibers to concrete, proper curing can also improve impact strength. This shows the importance of the hydration process for concrete.

Author Contributions

Conceptualization, A.S., I.S. and M.K.; Data curation, M.M.M., A.S., K.R. and A.H.S.; Formal analysis, A.S. and A.H.S.; Funding acquisition, M.K.; Investigation, M.M.M., A.S. and I.S.; Methodology, M.M.M., A.S., K.R., A.H.S., I.S. and M.K.; Project administration, A.S.; Resources, A.S.; Software, M.M.M., A.S., K.R. and V.A.; Supervision, A.S. and M.K.; Writing—review & editing, V.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

Not applicable.

Conflicts of Interest

The authors declare no conflict of interest.

Nomenclature

CScompressive strength
Ccellulose fiber
Eimpact energy
FSflexural strength
Fcfirst crack
ggravitation acceleration
HSChigh-strength concrete
HPChigh-performance concrete
hheight of drop
INPBthe increase in the number of post-first-crack blows
ISimpact strength
K-Sthe Kolmogorov–Smirnov test
K-Wthe Kruskal–Wallis test
l/dthe length/diameter
MKmetakaolin
Mmass of hammer
MADthe mean absolute deviation
MAPEthe mean absolute percentage error
Nfirstfirst visual crack
Nfailultimate crack
Np-failthe failure strength
Npthe predicted fracture strength
NMthe failure strength measured
PPpolypropylene
PCCPortland cement concrete
RGrecycled glass
RCrecycled Carbon
R2the coefficient of determination
SFsteel fiber
TStensile strength
UCultimate crack
W/Bwater-to-binder ratio
λductility index

References

  1. Afroughsabet, V.; Biolzi, L.; Monteiro, P.J. The effect of steel and polypropylene fibers on the chloride diffusivity and drying shrinkage of high-strength concrete. Compos. Part B Eng. 2018, 139, 84–96. [Google Scholar] [CrossRef]
  2. Celik, K.; Meral, C.; Mancio, M.; Mehta, P.K.; Monteiro, P.J. A comparative study of self-consolidating concretes incorporating high-volume natural pozzolan or high-volume fly ash. Constr. Build. Mater. 2014, 67, 14–19. [Google Scholar] [CrossRef]
  3. Mansoori, A.; Moein, M.M.; Mohseni, E. Effect of micro silica on fiber-reinforced self-compacting composites containing ceramic waste. J. Compos. Mater. 2021, 55, 95–107. [Google Scholar] [CrossRef]
  4. Saha, A.K.; Khan, M.N.N.; Sarker, P.K.; Shaikh, F.A.; Pramanik, A. The ASR mechanism of reactive aggregates in concrete and its mitigation by fly ash: A critical review. Constr. Build. Mater. 2018, 171, 743–758. [Google Scholar] [CrossRef]
  5. Tahmouresi, B.; Nemati, P.; Asadi, M.A.; Saradar, A.; Moein, M.M. Mechanical strength and microstructure of engineered cementitious composites: A new configuration for direct tensile strength, experimental and numerical analysis. Constr. Build. Mater. 2021, 269, 121361. [Google Scholar] [CrossRef]
  6. Aggarwal, Y.; Siddique, R. Microstructure and properties of concrete using bottom ash and waste foundry sand as partial replacement of fine aggregates. Constr. Build. Mater. 2014, 54, 210–223. [Google Scholar] [CrossRef] [Green Version]
  7. Ghasemzadeh Mosavinejad, H.; Saradar, A.; Tahmouresi, B. Hoop stress-strain in fiber-reinforced cementitious composite thin-walled cylindrical shells. J. Mater. Civ. Eng. 2018, 30, 04018258. [Google Scholar] [CrossRef]
  8. Koushkbaghi, M.; Alipour, P.; Tahmouresi, B.; Mohseni, E.; Saradar, A.; Sarker, P.K. Influence of different monomer ratios and recycled concrete aggregate on mechanical properties and durability of geopolymer concretes. Constr. Build. Mater. 2019, 205, 519–528. [Google Scholar] [CrossRef]
  9. Saradar, A.; Tahmouresi, B.; Mohseni, E.; Shadmani, A. Restrained shrinkage cracking of fiber-reinforced high-strength concrete. Fibers 2018, 6, 12. [Google Scholar] [CrossRef] [Green Version]
  10. Johari, M.M.; Brooks, J.; Kabir, S.; Rivard, P. Influence of supplementary cementitious materials on engineering properties of high strength concrete. Constr. Build. Mater. 2011, 25, 2639–2648. [Google Scholar] [CrossRef]
  11. Wille, K.; Naaman, A.E.; Parra-Montesinos, G.J. Ultra-High Performance Concrete with Compressive Strength Exceeding 150 MPa (22 ksi): A Simpler Way. ACI Mater. J. 2011, 108, 34–46. [Google Scholar]
  12. El-Helou, R.G.; Haber, Z.B.; Graybeal, B.A. Mechanical Behavior and Design Properties of Ultra-High-Performance Concrete. ACI Mater. J. 2022, 119, 181–194. [Google Scholar]
  13. Nia, A.A.; Hedayatian, M.; Nili, M.; Sabet, V.A. An experimental and numerical study on how steel and polypropylene fibers affect the impact resistance in fiber-reinforced concrete. Int. J. Impact Eng. 2012, 46, 62–73. [Google Scholar]
  14. Sharma, R.; Jang, J.G.; Bansal, P.P. A comprehensive review on effects of mineral admixtures and fibers on engineering properties of ultra-high-performance concrete. J. Build. Eng. 2022, 45, 103314. [Google Scholar] [CrossRef]
  15. Neville, A.M. Properties of Concrete; Pitman: Wetherby, UK, 1973. [Google Scholar]
  16. Saradar, A.; Nemati, P.; Paskiabi, A.S.; Moein, M.M.; Moez, H.; Vishki, E.H. Prediction of mechanical properties of lightweight basalt fiber reinforced concrete containing silica fume and fly ash: Experimental and numerical assessment. J. Build. Eng. 2020, 32, 101732. [Google Scholar] [CrossRef]
  17. Abbass, W.; Khan, M.I.; Mourad, S. Evaluation of mechanical properties of steel fiber reinforced concrete with different strengths of concrete. Constr. Build. Mater. 2018, 168, 556–569. [Google Scholar] [CrossRef]
  18. El-Dieb, A.S. Mechanical, durability and microstructural characteristics of ultra-high-strength self-compacting concrete incorporating steel fibers. Mater. Des. 2009, 30, 4286–4292. [Google Scholar] [CrossRef]
  19. Nili, M.; Afroughsabet, V. Combined effect of silica fume and steel fibers on the impact resistance and mechanical properties of concrete. Int. J. Impact Eng. 2010, 37, 879–886. [Google Scholar] [CrossRef] [Green Version]
  20. ACI Committee 544. Measurement of Properties of Fiber Reinforced Concrete; American Concrete Institute: Farmington Hills, MI, USA, 1988; pp. 583–593. [Google Scholar]
  21. Rahmani, T.; Kiani, B.; Shekarchi, M.; Safari, A. Statistical and experimental analysis on the behavior of fiber reinforced concretes subjected to drop weight test. Constr. Build. Mater. 2012, 37, 360–369. [Google Scholar] [CrossRef]
  22. Güneyisi, E.; Gesoğlu, M.; Akoi, A.O.M.; Mermerdaş, K. Combined effect of steel fiber and metakaolin incorporation on mechanical properties of concrete. Compos. Part B Eng. 2014, 56, 83–91. [Google Scholar] [CrossRef]
  23. Chen, G.; He, Y.; Yang, H.; Chen, J.; Guo, Y. Compressive behavior of steel fiber reinforced recycled aggregate concrete after exposure to elevated temperatures. Constr. Build. Mater. 2014, 71, 1–15. [Google Scholar] [CrossRef] [Green Version]
  24. Nataraja, M.; Nagaraj, T.; Basavaraja, S. Reproportioning of steel fibre reinforced concrete mixes and their impact resistance. Cem. Concr. Res. 2005, 35, 2350–2359. [Google Scholar] [CrossRef]
  25. Nataraja, M.; Dhang, N.; Gupta, A. Statistical variations in impact resistance of steel fiber-reinforced concrete subjected to drop weight test. Cem. Concr. Res. 1999, 29, 989–995. [Google Scholar] [CrossRef]
  26. Song, P.; Wu, J.; Hwang, S.; Sheu, B. Assessment of statistical variations in impact resistance of high-strength concrete and high-strength steel fiber-reinforced concrete. Cem. Concr. Res. 2005, 35, 393–399. [Google Scholar] [CrossRef]
  27. Olivito, R.; Zuccarello, F. An experimental study on the tensile strength of steel fiber reinforced concrete. Compos. Part B Eng. 2010, 41, 246–255. [Google Scholar] [CrossRef]
  28. Gesoğlu, M.; Güneyisi, E.; Alzeebaree, R.; Mermerdaş, K. Effect of silica fume and steel fiber on the mechanical properties of the concretes produced with cold bonded fly ash aggregates. Constr. Build. Mater. 2013, 40, 982–990. [Google Scholar] [CrossRef]
  29. Yoo, D.-Y.; Gohil, U.; Gries, T.; Yoon, Y.-S. Comparative low-velocity impact response of textile-reinforced concrete and steel-fiber-reinforced concrete beams. J. Compos. Mater. 2016, 50, 2421–2431. [Google Scholar] [CrossRef]
  30. Rizzuti, L.; Bencardino, F. Effects of fibre volume fraction on the compressive and flexural experimental behaviour of SFRC. Contemp. Eng. Sci. 2014, 7, 379–390. [Google Scholar] [CrossRef]
  31. Nili, M.; Afroughsabet, V. Property assessment of steel–fibre reinforced concrete made with silica fume. Constr. Build. Mater. 2012, 28, 664–669. [Google Scholar] [CrossRef]
  32. Nili, M.; Ghorbankhani, A.; AlaviNia, A.; Zolfaghari, M. Assessing the impact strength of steel fibre-reinforced concrete under quasi-static and high velocity dynamic impacts. Constr. Build. Mater. 2016, 107, 264–271. [Google Scholar] [CrossRef]
  33. Yan, H.; Sun, W.; Chen, H. The effect of silica fume and steel fiber on the dynamic mechanical performance of high-strength concrete. Cem. Concr. Res. 1999, 29, 423–426. [Google Scholar] [CrossRef]
  34. Wang, H.; Wang, L. Experimental study on static and dynamic mechanical properties of steel fiber reinforced lightweight aggregate concrete. Constr. Build. Mater. 2013, 38, 1146–1151. [Google Scholar] [CrossRef]
  35. Atiş, C.D.; Karahan, O. Properties of steel fiber reinforced fly ash concrete. Constr. Build. Mater. 2009, 23, 392–399. [Google Scholar] [CrossRef]
  36. Nazarimofrad, E.; Shaikh, F.U.A.; Nili, M. Effects of steel fibre and silica fume on impact behaviour of recycled aggregate concrete. J. Sustain. Cem.-Based Mater. 2017, 6, 54–68. [Google Scholar] [CrossRef]
  37. Huang, C.; Zhao, G. Properties of steel fibre reinforced concrete containing larger coarse aggregate. Cem. Concr. Compos. 1995, 17, 199–206. [Google Scholar] [CrossRef]
  38. Altun, F.; Haktanir, T.; Ari, K. Effects of steel fiber addition on mechanical properties of concrete and RC beams. Constr. Build. Mater. 2007, 21, 654–661. [Google Scholar] [CrossRef]
  39. Mohammadi, Y.; Singh, S.; Kaushik, S. Properties of steel fibrous concrete containing mixed fibres in fresh and hardened state. Constr. Build. Mater. 2008, 22, 956–965. [Google Scholar] [CrossRef]
  40. Mahakavi, P.; Chithra, R. Impact resistance, microstructures and digital image processing on self-compacting concrete with hooked end and crimped steel fiber. Constr. Build. Mater. 2019, 220, 651–666. [Google Scholar] [CrossRef]
  41. Carneiro, J.A.; Lima, P.R.L.; Leite, M.B.; Toledo Filho, R.D. Compressive stress–strain behavior of steel fiber reinforced-recycled aggregate concrete. Cem. Concr. Compos. 2014, 46, 65–72. [Google Scholar] [CrossRef]
  42. Afroughsabet, V.; Biolzi, L.; Ozbakkaloglu, T. Influence of double hooked-end steel fibers and slag on mechanical and durability properties of high performance recycled aggregate concrete. Compos. Struct. 2017, 181, 273–284. [Google Scholar] [CrossRef]
  43. Ibrahim, I.; Bakar, M.C. Effects on mechanical properties of industrialised steel fibres addition to normal weight concrete. Procedia Eng. 2011, 14, 2616–2626. [Google Scholar] [CrossRef] [Green Version]
  44. Huo, W.; Zhang, S. Research and Statistical Analysis on Impact Resistance of Steel Fiber Expanded Polystyrene Concrete and Expanded Polystyrene Concrete. Materials 2022, 15, 4216. [Google Scholar] [CrossRef]
  45. Eren, Ö.; Marar, K. Effects of limestone crusher dust and steel fibers on concrete. Constr. Build. Mater. 2009, 23, 981–988. [Google Scholar] [CrossRef]
  46. Düzgün, O.A.; Gül, R.; Aydin, A.C. Effect of steel fibers on the mechanical properties of natural lightweight aggregate concrete. Mater. Lett. 2005, 59, 3357–3363. [Google Scholar] [CrossRef]
  47. Alrawashdeh, A.; Eren, O. Mechanical and physical characterisation of steel fibre reinforced self-compacting concrete: Different aspect ratios and volume fractions of fibres. Results Eng. 2022, 13, 100335. [Google Scholar] [CrossRef]
  48. Kachouh, N.; El-Hassan, H.; El-Maaddawy, T. Effect of steel fibers on the performance of concrete made with recycled concrete aggregates and dune sand. Constr. Build. Mater. 2019, 213, 348–359. [Google Scholar] [CrossRef]
  49. Rai, B.; Singh, N.K. Statistical and experimental study to evaluate the variability and reliability of impact strength of steel-polypropylene hybrid fiber reinforced concrete. J. Build. Eng. 2021, 44, 102937. [Google Scholar] [CrossRef]
  50. Ghorpade, V.G.; Rao, H.S. Strength and permeability characteristics of Fibre reinforced recycled aggregate concrete with different fibres. Nat. Environ. Pollut. Technol. 2010, 9, 179–188. [Google Scholar]
  51. Lee, S.-C.; Oh, J.-H.; Cho, J.-Y. Compressive behavior of fiber-reinforced concrete with end-hooked steel fibers. Materials 2015, 8, 1442–1458. [Google Scholar] [CrossRef] [Green Version]
  52. Bywalski, C.; Kamiński, M.; Maszczak, M.; Balbus, Ł. Influence of steel fibres addition on mechanical and selected rheological properties of steel fibre high-strength reinforced concrete. Arch. Civ. Mech. Eng. 2015, 15, 742–750. [Google Scholar] [CrossRef]
  53. Pham, K.V.A.; Nguyen, K.T.; Le, T.A.; Lee, K. Investigation of impact behavior of innovative non-curing steel fiber geopolymer composites. Case Stud. Constr. Mater. 2022, 16, e01011. [Google Scholar] [CrossRef]
  54. Mastali, M.; Dalvand, A.; Sattarifard, A.; Abdollahnejad, Z.; Illikainen, M. Characterization and optimization of hardened properties of self-consolidating concrete incorporating recycled steel, industrial steel, polypropylene and hybrid fibers. Compos. Part B Eng. 2018, 151, 186–200. [Google Scholar] [CrossRef]
  55. Hu, H.; Papastergiou, P.; Angelakopoulos, H.; Guadagnini, M.; Pilakoutas, K. Mechanical properties of SFRC using blended recycled tyre steel cords (RTSC) and recycled tyre steel fibres (RTSF). Constr. Build. Mater. 2018, 187, 553–564. [Google Scholar] [CrossRef]
  56. Gao, D.; Zhang, L. Flexural performance and evaluation method of steel fiber reinforced recycled coarse aggregate concrete. Constr. Build. Mater. 2018, 159, 126–136. [Google Scholar] [CrossRef]
  57. Ismail, M.K.; Hassan, A.A. Impact resistance and mechanical properties of self-consolidating rubberized concrete reinforced with steel fibers. J. Mater. Civ. Eng. 2017, 29, 04016193. [Google Scholar] [CrossRef]
  58. Gao, D.; Zhang, L.; Zhao, J.; You, P. Durability of steel fibre-reinforced recycled coarse aggregate concrete. Constr. Build. Mater. 2020, 232, 117119. [Google Scholar] [CrossRef]
  59. Xie, J.; Zhang, Z.; Lu, Z.; Sun, M. Coupling effects of silica fume and steel-fiber on the compressive behaviour of recycled aggregate concrete after exposure to elevated temperature. Constr. Build. Mater. 2018, 184, 752–764. [Google Scholar] [CrossRef]
  60. Söylev, T.; Özturan, T. Durability, physical and mechanical properties of fiber-reinforced concretes at low-volume fraction. Constr. Build. Mater. 2014, 73, 67–75. [Google Scholar] [CrossRef]
  61. Chen, X.-y.; Ding, Y.-n.; Azevedo, C. Combined effect of steel fibres and steel rebars on impact resistance of high performance concrete. J. Cent. South Univ. 2011, 18, 1677–1684. [Google Scholar] [CrossRef] [Green Version]
  62. Ou, Y.-C.; Tsai, M.-S.; Liu, K.-Y.; Chang, K.-C. Compressive behavior of steel-fiber-reinforced concrete with a high reinforcing index. J. Mater. Civ. Eng. 2012, 24, 207–215. [Google Scholar] [CrossRef]
  63. Murali, G.; Prasad, N.; Abid, S.R.; Vatin, N.I. Response of Functionally Graded Preplaced Aggregate Fibrous Concrete with Superior Impact Strength. Buildings 2022, 12, 563. [Google Scholar] [CrossRef]
  64. Ameri, F.; de Brito, J.; Madhkhan, M.; Taheri, R.A. Steel fibre-reinforced high-strength concrete incorporating copper slag: Mechanical, gamma-ray shielding, impact resistance, and microstructural characteristics. J. Build. Eng. 2020, 29, 101118. [Google Scholar] [CrossRef]
  65. Koushkbaghi, M.; Kazemi, M.J.; Mosavi, H.; Mohseni, E. Acid resistance and durability properties of steel fiber-reinforced concrete incorporating rice husk ash and recycled aggregate. Constr. Build. Mater. 2019, 202, 266–275. [Google Scholar] [CrossRef]
  66. Yazıcı, Ş.; İnan, G.; Tabak, V. Effect of aspect ratio and volume fraction of steel fiber on the mechanical properties of SFRC. Constr. Build. Mater. 2007, 21, 1250–1253. [Google Scholar] [CrossRef]
  67. Reddy, S.V.B.; Rao, P.S. Experimental studies on mechanical properties and impact characteristics of ternary concrete with steel fiber. Mater. Today Proc. 2020, 27, 788–797. [Google Scholar] [CrossRef]
  68. Xie, J.-h.; Guo, Y.-c.; Liu, L.-s.; Xie, Z.-h. Compressive and flexural behaviours of a new steel-fibre-reinforced recycled aggregate concrete with crumb rubber. Constr. Build. Mater. 2015, 79, 263–272. [Google Scholar] [CrossRef]
  69. Abdallah, S.; Rees, D.W.; Ghaffar, S.H.; Fan, M. Understanding the effects of hooked-end steel fibre geometry on the uniaxial tensile behaviour of self-compacting concrete. Constr. Build. Mater. 2018, 178, 484–494. [Google Scholar] [CrossRef] [Green Version]
  70. Soutsos, M.; Le, T.; Lampropoulos, A. Flexural performance of fibre reinforced concrete made with steel and synthetic fibres. Constr. Build. Mater. 2012, 36, 704–710. [Google Scholar] [CrossRef]
  71. Naraganti, S.R.; Pannem, R.M.R.; Putta, J. Impact resistance of hybrid fibre reinforced concrete containing sisal fibres. Ain Shams Eng. J. 2019, 10, 297–305. [Google Scholar] [CrossRef]
  72. ACI Committee 308 b. Guide to Curing Concrete, ACI 308R-01, ACI Manual of Concrete Practice; American Concrete Institute: Farmington Hills, MI, USA, 2001. [Google Scholar]
  73. Yilmaz, H. Shear-bond strength testing of thin spray-on liners. J. S. Afr. Inst. Min. Metall. 2007, 107, 519–530. [Google Scholar]
  74. Yilmaz, H. Tensile strength testing of thin spray-on liner products (TSLs) and shotcrete. J. S. Afr. Inst. Min. Metall. 2010, 110, 559–569. [Google Scholar]
  75. ASTM C39/C39M-21; Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens. ASTM International: West Conshohocken, PA, USA, 2003.
  76. BS EN 12350-2:2009; Testing Fresh Concrete. British Standard Institution: London, UK, 2009.
  77. ASTM C496-96; Standard Test Method for Splitting Tensile Strength of Cylindrical Concrete Specimens. ASTM International: West Conshohocken, PA, USA, 2004.
  78. Mastali, M.; Dalvand, A. The impact resistance and mechanical properties of self-compacting concrete reinforced with recycled CFRP pieces. Compos. Part B Eng. 2016, 92, 360–376. [Google Scholar] [CrossRef]
  79. Fakharifar, M.; Dalvand, A.; Arezoumandi, M.; Sharbatdar, M.K.; Chen, G.; Kheyroddin, A. Mechanical properties of high performance fiber reinforced cementitious composites. Constr. Build. Mater. 2014, 71, 510–520. [Google Scholar] [CrossRef]
  80. Dalvand, A.; Sharbatdar, M.; Kheyroddin, A.; Nikui, A. Assessment of statistical variations in experimental impact resistance and mechanical properties of silica fume concrete. Sci. Iran. 2014, 21, 1577–1590. [Google Scholar]
  81. Badr, A.; Ashour, A.F.; Platten, A.K. Statistical variations in impact resistance of polypropylene fibre-reinforced concrete. Int. J. Impact Eng. 2006, 32, 1907–1920. [Google Scholar] [CrossRef] [Green Version]
  82. Bingöl, A.F.; Tohumcu, İ. Effects of different curing regimes on the compressive strength properties of self compacting concrete incorporating fly ash and silica fume. Mater. Des. 2013, 51, 12–18. [Google Scholar] [CrossRef]
  83. Razzaghi, H.; Madandoust, R.; Aghabarati, H. Point-load test and UPV for compressive strength prediction of recycled coarse aggregate concrete via generalized GMDH-class neural network. Constr. Build. Mater. 2021, 276, 122143. [Google Scholar] [CrossRef]
  84. Benli, A.; Karataş, M.; Bakir, Y. An experimental study of different curing regimes on the mechanical properties and sorptivity of self-compacting mortars with fly ash and silica fume. Constr. Build. Mater. 2017, 144, 552–562. [Google Scholar] [CrossRef]
  85. Haghighatnejad, N.; Mousavi, S.Y.; Khaleghi, S.J.; Tabarsa, A.; Yousefi, S. Properties of recycled PVC aggregate concrete under different curing conditions. Constr. Build. Mater. 2016, 126, 943–950. [Google Scholar] [CrossRef]
  86. Ismail, S.; Kwan, W.H.; Ramli, M. Mechanical strength and durability properties of concrete containing treated recycled concrete aggregates under different curing conditions. Constr. Build. Mater. 2017, 155, 296–306. [Google Scholar] [CrossRef]
  87. Aghaee, K.; Yazdi, M.A.; Tsavdaridis, K.D. Investigation into the mechanical properties of structural lightweight concrete reinforced with waste steel wires. Mag. Concr. Res. 2015, 67, 197–205. [Google Scholar] [CrossRef] [Green Version]
  88. Cao, H. Experimental investigation on the static and impact behaviors of basalt fiber-reinforced concrete. Open Civ. Eng. J. 2017, 11, 14–21. [Google Scholar] [CrossRef] [Green Version]
  89. Jun Li, J.; Gang Niu, J.; Jun Wan, C.; Jin, B.; Liu Yin, Y. Investigation on mechanical properties and microstructure of high performance polypropylene fiber reinforced lightweight aggregate concrete. Constr. Build. Mater. 2016, 118, 27–35. [Google Scholar]
  90. Prasad, N.; Murali, G. Exploring the impact performance of functionally-graded preplaced aggregate concrete incorporating steel and polypropylene fibres. J. Build. Eng. 2021, 35, 102077. [Google Scholar] [CrossRef]
  91. Ding, Y.; Li, D.; Zhang, Y.; Azevedo, C. Experimental investigation on the composite effect of steel rebars and macro fibers on the impact behavior of high performance self-compacting concrete. Constr. Build. Mater. 2017, 136, 495–505. [Google Scholar] [CrossRef] [Green Version]
  92. Feng, J.; Sun, W.; Zhai, H.; Wang, L.; Dong, H.; Wu, Q. Experimental study on hybrid effect evaluation of fiber reinforced concrete subjected to drop weight impacts. Materials 2018, 11, 2563. [Google Scholar] [CrossRef] [Green Version]
  93. Nili, M.; Afroughsabet, V. The effects of silica fume and polypropylene fibers on the impact resistance and mechanical properties of concrete. Constr. Build. Mater. 2010, 24, 927–933. [Google Scholar] [CrossRef]
  94. Bodt, B.A. Engineering Statistics: The Industrial Experience; Taylor & Francis: Cambridge, UK, 1997. [Google Scholar]
  95. Cheng, M.-Y.; Firdausi, P.M.; Prayogo, D. High-performance concrete compressive strength prediction using Genetic Weighted Pyramid Operation Tree (GWPOT). Eng. Appl. Artif. Intell. 2014, 29, 104–113. [Google Scholar] [CrossRef]
  96. Mastali, M.; Dalvand, A.; Sattarifard, A. The impact resistance and mechanical properties of reinforced self-compacting concrete with recycled glass fibre reinforced polymers. J. Clean. Prod. 2016, 124, 312–324. [Google Scholar] [CrossRef]
  97. Song, P.; Wu, J.; Hwang, S.; Sheu, B. Statistical analysis of impact strength and strength reliability of steel–polypropylene hybrid fiber-reinforced concrete. Constr. Build. Mater. 2005, 19, 1–9. [Google Scholar] [CrossRef]
Figure 1. Overview of the study process.
Figure 1. Overview of the study process.
Materials 15 07157 g001
Figure 2. Particle size distributions of the fine and coarse aggregates.
Figure 2. Particle size distributions of the fine and coarse aggregates.
Materials 15 07157 g002
Figure 3. (a) Crimped hooked-end steel fiber [2 cm]; (b) Hooked-end steel fiber [3 cm]; (c) Crimped hooked-end steel fiber [5 cm].
Figure 3. (a) Crimped hooked-end steel fiber [2 cm]; (b) Hooked-end steel fiber [3 cm]; (c) Crimped hooked-end steel fiber [5 cm].
Materials 15 07157 g003
Figure 4. Result of slump test.
Figure 4. Result of slump test.
Materials 15 07157 g004
Figure 5. Molding of cylindrical and cubic specimens.
Figure 5. Molding of cylindrical and cubic specimens.
Materials 15 07157 g005
Figure 6. Schematic diagram of impact test—specimen setup.
Figure 6. Schematic diagram of impact test—specimen setup.
Materials 15 07157 g006
Figure 7. Cut samples (a) cutting machine (b) concrete disc specimens.
Figure 7. Cut samples (a) cutting machine (b) concrete disc specimens.
Materials 15 07157 g007
Figure 8. Information on samples and discs used in impact testing.
Figure 8. Information on samples and discs used in impact testing.
Materials 15 07157 g008
Figure 9. Mechanical tests performed.
Figure 9. Mechanical tests performed.
Materials 15 07157 g009
Figure 10. Strength of the concrete mixes: (a) 28 days compressive tensile strength; (b) 28 days split tensile strength.
Figure 10. Strength of the concrete mixes: (a) 28 days compressive tensile strength; (b) 28 days split tensile strength.
Materials 15 07157 g010
Figure 11. Average blows for concrete discs: (a) first-crack strength; (b) failure strength.
Figure 11. Average blows for concrete discs: (a) first-crack strength; (b) failure strength.
Materials 15 07157 g011
Figure 12. Distribution plots for first crack (humid): (a) R, (b) F2, (c) F3.
Figure 12. Distribution plots for first crack (humid): (a) R, (b) F2, (c) F3.
Materials 15 07157 g012
Figure 13. Normal probability plots for first crack (humid): (a) R, (b) F2, (c) F3.
Figure 13. Normal probability plots for first crack (humid): (a) R, (b) F2, (c) F3.
Materials 15 07157 g013
Figure 14. Distribution plots for first crack (humid): (a) F5, (b) F2F3.
Figure 14. Distribution plots for first crack (humid): (a) F5, (b) F2F3.
Materials 15 07157 g014
Figure 15. Normal probability plots for first crack (humid): (a) F5, (b) F2F3.
Figure 15. Normal probability plots for first crack (humid): (a) F5, (b) F2F3.
Materials 15 07157 g015
Figure 16. Distribution plots for first crack (dry): (a) R, (b) F2, (c) F3.
Figure 16. Distribution plots for first crack (dry): (a) R, (b) F2, (c) F3.
Materials 15 07157 g016
Figure 17. Normal probability plots for first crack (dry): (a) R, (b) F2, (c) F3.
Figure 17. Normal probability plots for first crack (dry): (a) R, (b) F2, (c) F3.
Materials 15 07157 g017
Figure 18. Distribution plots for first crack (dry): (a) F5, (b) F2F3.
Figure 18. Distribution plots for first crack (dry): (a) F5, (b) F2F3.
Materials 15 07157 g018
Figure 19. Normal probability plots for first crack (dry): (a) F5, (b) F2F3.
Figure 19. Normal probability plots for first crack (dry): (a) F5, (b) F2F3.
Materials 15 07157 g019
Figure 20. Distribution plots for failure strength (humid): (a) R, (b) F2, (c) F3.
Figure 20. Distribution plots for failure strength (humid): (a) R, (b) F2, (c) F3.
Materials 15 07157 g020
Figure 21. Normal probability plots for failure strength (humid): (a) R, (b) F2, (c) F3.
Figure 21. Normal probability plots for failure strength (humid): (a) R, (b) F2, (c) F3.
Materials 15 07157 g021
Figure 22. Distribution plots for failure strength (humid): (a) F5, (b) F2F3.
Figure 22. Distribution plots for failure strength (humid): (a) F5, (b) F2F3.
Materials 15 07157 g022
Figure 23. Normal probability plots for failure strength (humid): (a) F5, (b) F2F3.
Figure 23. Normal probability plots for failure strength (humid): (a) F5, (b) F2F3.
Materials 15 07157 g023
Figure 24. Distribution plots for failure strength (dry): (a) R, (b) F2, (c) F3.
Figure 24. Distribution plots for failure strength (dry): (a) R, (b) F2, (c) F3.
Materials 15 07157 g024
Figure 25. Normal probability plots for failure strength (dry): (a) R, (b) F2, (c) F3.
Figure 25. Normal probability plots for failure strength (dry): (a) R, (b) F2, (c) F3.
Materials 15 07157 g025
Figure 26. Distribution plots for failure strength (dry): (a) F5, (b) F2F3.
Figure 26. Distribution plots for failure strength (dry): (a) F5, (b) F2F3.
Materials 15 07157 g026
Figure 27. Normal probability plots for failure strength (dry): (a) F5, (b) F2F3.
Figure 27. Normal probability plots for failure strength (dry): (a) F5, (b) F2F3.
Materials 15 07157 g027
Figure 28. Specimens after impact test: (a) plain concrete, (b) steel fiber reinforced concrete, (c) fiber bridging.
Figure 28. Specimens after impact test: (a) plain concrete, (b) steel fiber reinforced concrete, (c) fiber bridging.
Materials 15 07157 g028
Figure 29. Impact energy results for first crack ((A): humid, (B): dry) and failure strength ((C): humid, (D): dry).
Figure 29. Impact energy results for first crack ((A): humid, (B): dry) and failure strength ((C): humid, (D): dry).
Materials 15 07157 g029
Table 1. Information on previous studies.
Table 1. Information on previous studies.
ReferenceType of ConcreteFiber ShapeFiber Percentage (%)Fiber GeometryMechanical Properties
d (mm)l (mm)l/d
Güneyisi et al. [22]Normal + MK + SFHooked-end0.25, 0.750.7530, 6040, 80Materials 15 07157 i001
CS
Materials 15 07157 i002
TS
Materials 15 07157 i003
FS
Materials 15 07157 i004
IS
Chen et al. [23]Recycled aggregate concrete + SFCrimped0.5, 1, 1.50.83240Materials 15 07157 i005
CS
Materials 15 07157 i006
TS
Materials 15 07157 i007
FS
Materials 15 07157 i008
IS
Nataraja et al. [24]Normal + SFCrimped0.5, 1, 1.514040Materials 15 07157 i009
CS
Materials 15 07157 i010
TS
Materials 15 07157 i011
FS
Materials 15 07157 i012
IS
Nataraja et al. [25]Normal + SFCrimped0.50.527.555Materials 15 07157 i013
CS
Materials 15 07157 i014
TS
Materials 15 07157 i015
FS
Materials 15 07157 i016
IS
Song et al. [26]High-strength concrete + SFHooked-end10.83540Materials 15 07157 i017
CS
Materials 15 07157 i018
TS
Materials 15 07157 i019
FS
Materials 15 07157 i020
IS
Olivito and Zuccarello
[27]
Normal + SFUndefined1, 20.44, 0.60, 0.822, 30, 4450Materials 15 07157 i021
CS
Materials 15 07157 i022
TS
Materials 15 07157 i023
FS
Materials 15 07157 i024
IS
Gesoglu et al. [28]Normal + silica fume +SFHooked-end0.25, 0.750.7530, 6040, 80Materials 15 07157 i025
CS
Materials 15 07157 i026
TS
Materials 15 07157 i027
FS
Materials 15 07157 i028
IS
Yoo et al. [29]Textile-reinforced concrete + SFHooked-end0.5, 1, 1.5, 20.53060Materials 15 07157 i029
CS
Materials 15 07157 i030
TS
Materials 15 07157 i031
FS
Materials 15 07157 i032
IS
Rizzuti and Bencardino
[30]
Normal + SFHooked-end1, 1.6, 3, 50.552240Materials 15 07157 i033
CS
Materials 15 07157 i034
TS
Materials 15 07157 i035
FS
Materials 15 07157 i036
IS
Nili and Afroughsabet
[19]
Normal+ silica fume +SFHooked-end0.5, 10.756080Materials 15 07157 i037
CS
Materials 15 07157 i038
TS
Materials 15 07157 i039
FS
Materials 15 07157 i040
IS
Nili and Afroughsabet
[31]
Normal+ silica fume +SFHooked-end0.5, 10.756080Materials 15 07157 i041
CS
Materials 15 07157 i042
TS
Materials 15 07157 i043
FS
Materials 15 07157 i044
IS
Nili et al. [32]Normal+ silica fume +SFHooked-end10.755067Materials 15 07157 i045
CS
Materials 15 07157 i046
TS
Materials 15 07157 i047
FS
Materials 15 07157 i048
IS
Yan et al. [33]High-strength concrete + SFStraight1.50.4172560Materials 15 07157 i049
CS
Materials 15 07157 i050
TS
Materials 15 07157 i051
FS
Materials 15 07157 i052
IS
Wang [34]Lightweight aggregate concrete + SFSlightly enlarged ends0.5, 1, 1.5, 2643250Materials 15 07157 i053
CS
Materials 15 07157 i054
TS
Materials 15 07157 i055
FS
Materials 15 07157 i056
IS
Atis and Karahan [35]Normal + fly ash + SFHooked-end0, 0.25, 0.5, 1, 1.50.553564Materials 15 07157 i057
CS
Materials 15 07157 i058
TS
Materials 15 07157 i059
FS
Materials 15 07157 i060
IS
Nazarimofrad et al. [36]Recycled aggregate concrete + SFHooked-end10.855060Materials 15 07157 i061
CS
Materials 15 07157 i062
TS
Materials 15 07157 i063
FS
Materials 15 07157 i064
IS
Huang and Zhao [37]Normal + SFUndefined1, 20.5825, 35, 4543, 60, 77Materials 15 07157 i065
CS
Materials 15 07157 i066
TS
Materials 15 07157 i067
FS
Materials 15 07157 i068
IS
Altun et al. [38]Normal + SFHooked-end0.5, 1, 1.50.756080Materials 15 07157 i069
CS
Materials 15 07157 i070
TS
Materials 15 07157 i071
FS
Materials 15 07157 i072
IS
Rahmani et al. [21]Normal + SFHooked-end0.50.553564Materials 15 07157 i073
CS
Materials 15 07157 i074
TS
Materials 15 07157 i075
FS
Materials 15 07157 i076
IS
Mohammadi et al. [39]Normal + SFUndefined1, 1.5, 21.2525, 5020, 40Materials 15 07157 i077
CS
Materials 15 07157 i078
TS
Materials 15 07157 i079
FS
Materials 15 07157 i080
IS
Abbass et al. [17]Normal + SFHooked-end0.5, 1, 1.50.62, 0.7540, 50, 6065, 80Materials 15 07157 i081
CS
Materials 15 07157 i082
TS
Materials 15 07157 i083
FS
Materials 15 07157 i084
IS
Mahakavi and Chithra [40]Self-compacting concrete + SFHooked-end0.25, 0.5, 0.750.770100Materials 15 07157 i085
CS
Materials 15 07157 i086
TS
Materials 15 07157 i087
FS
Materials 15 07157 i088
IS
Crimped0.25, 0.5
Carneiro et al. [41]Recycled aggregate concrete + SFHooked-end0.750.553565Materials 15 07157 i089
CS
Materials 15 07157 i090
TS
Materials 15 07157 i091
FS
Materials 15 07157 i092
IS
Afroughsabet et al. [42]High-performance recycled aggregate concrete + SFHooked-end10.96067Materials 15 07157 i093
CS
Materials 15 07157 i094
TS
Materials 15 07157 i095
FS
Materials 15 07157 i096
IS
Ibrahim and Bakar [43]Normal + SFHooked-end0.5, 0.75, 1, 1.250.756080Materials 15 07157 i097
CS
Materials 15 07157 i098
TS
Materials 15 07157 i099
FS
Materials 15 07157 i100
IS
Huo and Zhang [44]Steel fiber foamed concreteCrimped1 4824Materials 15 07157 i101
CS
Materials 15 07157 i102
TS
Materials 15 07157 i103
FS
Materials 15 07157 i104
IS
Eren and Marar [45]Limestone crusher dust and steel fibers on concreteHooked-end0.5, 1, 1.50.50, 0.75, 0.9050, 6065, 80, 100Materials 15 07157 i105
CS
Materials 15 07157 i106
TS
Materials 15 07157 i107
FS
Materials 15 07157 i108
IS
Düzgün et al. [46]Lightweight concrete + SFHooked-end0.5, 1, 1.50.86075Materials 15 07157 i109
CS
Materials 15 07157 i110
TS
Materials 15 07157 i111
FS
Materials 15 07157 i112
IS
Alrawashdeh and Eren [47]Self-compacting concrete + SFHooked-end0.35, 0.45, 0.550.53060Materials 15 07157 i113
CS
Materials 15 07157 i114
TS
Materials 15 07157 i115
FS
Materials 15 07157 i116
IS
0.6255080
Kachouh et al. [48]Recycled aggregate concrete + SFHooked-end1, 2, 30.553565Materials 15 07157 i117
CS
Materials 15 07157 i118
TS
Materials 15 07157 i119
FS
Materials 15 07157 i120
IS
Rai and Singh [49]Normal + SFCrimped0.1, 0.2, 0.3 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1, 1.25, 1.50.63050Materials 15 07157 i121
CS
Materials 15 07157 i122
TS
Materials 15 07157 i123
FS
Materials 15 07157 i124
IS
Ghorpade and Rao [50]Recycled aggregate concrete + SFUndefined0.5, 0.75, 1, 1.251100100Materials 15 07157 i125
CS
Materials 15 07157 i126
TS
Materials 15 07157 i127
FS
Materials 15 07157 i128
IS
Alavi Nia et al. [13]Normal + SFHooked-end0.5, 10.756080Materials 15 07157 i129
CS
Materials 15 07157 i130
TS
Materials 15 07157 i131
FS
Materials 15 07157 i132
IS
Lee et al. [51]High-strength concrete + SFHooked-end0.5, 1, 1.5, 20.38, 0.55, 1.0530, 35, 5079, 64, 48Materials 15 07157 i133
CS
Materials 15 07157 i134
TS
Materials 15 07157 i135
FS
Materials 15 07157 i136
IS
Bywalski et al. [52]High-strength concrete + SFStraight1, 2, 30.21365Materials 15 07157 i137
CS
Materials 15 07157 i138
TS
Materials 15 07157 i139
FS
Materials 15 07157 i140
IS
Pham et al. [53]Geopolymer concrete + SFHooked-end0.5, 1, 1.50.53060Materials 15 07157 i141
CS
Materials 15 07157 i142
TS
Materials 15 07157 i143
FS
Materials 15 07157 i144
IS
Mastali et al. [54]Self-consolidating concrete + SFHooked-end0.5, 0.75, 1, 1.5------47Materials 15 07157 i145
CS
Materials 15 07157 i146
TS
Materials 15 07157 i147
FS
Materials 15 07157 i148
IS
Hu et al. [55]Normal + SFWavy profile0.38, 0.45, 0.570.8, 1.055, 6069, 60Materials 15 07157 i149
CS
Materials 15 07157 i150
TS
Materials 15 07157 i151
FS
Materials 15 07157 i152
IS
Gao and Zhang [56]Recycled aggregate concrete + SFHooked-end0.5, 1, 1.5, 20.630.554.6Materials 15 07157 i153
CS
Materials 15 07157 i154
TS
Materials 15 07157 i155
FS
Materials 15 07157 i156
IS
Ismail et al. [57]Self-consolidating rubberized concrete + SFHooked-end0.35, 0.5, 0.75, 10.553565Materials 15 07157 i157
CS
Materials 15 07157 i158
TS
Materials 15 07157 i159
FS
Materials 15 07157 i160
IS
0.906065
Gao et al. [58]Recycled aggregate concrete + SFHooked-end0.5, 1, 1.5, 20.630.554.6Materials 15 07157 i161
CS
Materials 15 07157 i162
TS
Materials 15 07157 i163
FS
Materials 15 07157 i164
IS
Xie et al. [59]Recycled aggregate concrete + SFHooked-end10.21365Materials 15 07157 i165
CS
Materials 15 07157 i166
TS
Materials 15 07157 i167
FS
Materials 15 07157 i168
IS
Soylev and Ozturan [60]Normal + SFHooked-end0.50.553564Materials 15 07157 i169
CS
Materials 15 07157 i170
TS
Materials 15 07157 i171
FS
Materials 15 07157 i172
IS
Chen et al. [61]Normal + SFHooked-end0.5, 10.553564Materials 15 07157 i173
CS
Materials 15 07157 i174
TS
Materials 15 07157 i175
FS
Materials 15 07157 i176
IS
Ou et al. [62]Normal + SFHooked-end0.8, 1.6, 2, 2.4, 2.6, 3, 3.40.5, 0.6, 1.030, 50, 6050, 60, 70, 100Materials 15 07157 i177
CS
Materials 15 07157 i178
TS
Materials 15 07157 i179
FS
Materials 15 07157 i180
IS
Murali et al. [63]Functionally graded concrete + SFHooked-end crimped0.8–3.615050Materials 15 07157 i181
CS
Materials 15 07157 i182
TS
Materials 15 07157 i183
FS
Materials 15 07157 i184
IS
Ameri et al. [64]High-strength concrete + SFHooked-end10.553055Materials 15 07157 i185
CS
Materials 15 07157 i186
TS
Materials 15 07157 i187
FS
Materials 15 07157 i188
IS
Koushkbaghi et al. [65]Recycled aggregate concrete + SFHooked-end1.50.755067Materials 15 07157 i189
CS
Materials 15 07157 i190
TS
Materials 15 07157 i191
FS
Materials 15 07157 i192
IS
Yazıcı et al. [66]Normal + SFHooked-end0.5, 1, 1.50.62, 0.90, 0.7530, 60, 6045, 65, 80Materials 15 07157 i193
CS
Materials 15 07157 i194
TS
Materials 15 07157 i195
FS
Materials 15 07157 i196
IS
Reddy and Rao [67]Normal + SFCrimped0.5, 1, 1.5, 20.53060Materials 15 07157 i197
CS
Materials 15 07157 i198
TS
Materials 15 07157 i199
FS
Materials 15 07157 i200
IS
Jian-he et al. [68]Recycled aggregate concrete + SF + rubber crumbCrimped10.703245Materials 15 07157 i201
CS
Materials 15 07157 i202
TS
Materials 15 07157 i203
FS
Materials 15 07157 i204
IS
Abdallah et al. [69]Self-compacting concrete + SFSingle hooked0.5, 10.906067Materials 15 07157 i205
CS
Materials 15 07157 i206
TS
Materials 15 07157 i207
FS
Materials 15 07157 i208
IS
Double hooked
Triple hooked
Soutsos et al. [70]Normal + SFHooked-end0.5, 1, 1.50.96067Materials 15 07157 i209
CS
Materials 15 07157 i210
TS
Materials 15 07157 i211
FS
Materials 15 07157 i212
IS
Wavy profile0.150, 6050, 60
Flattened end0.15050
CS: compressive strength; TS: tensile strength; FS: flexural strength; IS: impact strength.
Table 2. Chemical composition of cement and silica fume.
Table 2. Chemical composition of cement and silica fume.
Chemical AnalysisCement (wt%)Silica Fume (wt%)
SiO220.2391.44
Al2O34.861
Fe2O34.520.9
CaO63.861.69
MgO2.141.78
SO32.120.77
K2O0.710.07
Na2O0.210.05
LOI0.852.01
Table 3. Properties of superplasticizer.
Table 3. Properties of superplasticizer.
Chemical BasePhysical StateChlorine IonColorSpecific Weight
PolycarboxylatesLiquidMaterials 15 07157 i004Light brown120 ± 0.05 g/cm3
Table 4. Properties of steel fibers.
Table 4. Properties of steel fibers.
Length (mm)Diameter (mm)Aspect Ratio (l/d)Specific GravityTensile Strength (MPa)Geometry
200.75277.81140Crimped
300.75407.81140Hooked
500.75677.81140Crimped
Table 5. Mixed proportions of concrete.
Table 5. Mixed proportions of concrete.
MixCement
(kg.m−3)
SF
(kg.m−3)
Water
(kg.m−3)
Gravel
(kg.m−3)
Sand
(kg.m−3)
Steel Fibers (%)
Crimped FiberHooked-End FiberCrimped Fiber
20 mm30 mm50 mm
R40545180900970---
F2405451809009701--
F340545180900970-1-
F540545180900970--1
F2F3405451809009700.50.5-
Table 6. Characteristics of tests, specimens, and standards.
Table 6. Characteristics of tests, specimens, and standards.
Hardened ConcreteFresh Concrete
TestDimensionStandardShapeTestStandard
Compressive strength150 × 150 × 150 mmASTM C39-03 [75]Materials 15 07157 i214Slump flow timeBS EN 12350-2 [76]
Tensile strength300 × 150 mmASTM C496-04 [77]Materials 15 07157 i215
Impact strength300 × 150 mmACI committee 544 [20]Materials 15 07157 i216
Table 7. Repeatability test results for previous studies and the present study.
Table 7. Repeatability test results for previous studies and the present study.
Ref.TESTRI
Mastali and Dalvand [78]First crack strength38.45
Fakharifar et al. [79]43.66
Rahmani et al. [21]57.5
Dalvand et al. [80]27.56
Badr et al. [81]59
Present Work44
Mastali and Dalvand [78]Failure strength37.3
Fakharifar et al. [79]43.66
Rahmani et al. [21]48
Dalvand et al. [80]26.41
Badr et al. [81]50.4
Present Work41.4
Mastali and Dalvand [78]INPB59
Fakharifar et al. [79]49.66
Dalvand et al. [80]46.04
Present Work58
Mastali and Dalvand [78]Compressive strength6.18
Fakharifar et al. [79]6.73
Dalvand et al. [80]4.37
Badr et al. [81]7.55
Present Work3.66
Dalvand et al. [80]Tensile strength8.19
Present Work7.57
Lee et al. [51]Slump 25.60
Present Work11.08
Table 8. Statistical variables for initial crack strength, fracture strength, and samples.
Table 8. Statistical variables for initial crack strength, fracture strength, and samples.
MixCuringStrengthMean
(Blows)
Standard Deviation
(Blows)
Coefficient of Variation
(%)
Standard Error of Mean
(Blows)
95% Confidence Intervalp-Value of K–S Test
Upper Bound
(Blows)
Lower Bound
(Blows)
RH U M I DFirst Crack144402771581300.093
Failure150392671641370.068
INPB63450.51584<0.01
F2First Crack17256339.98191152>0.15
Failure192572910211172>0.15
INPB208411.452317>0.15
F3First Crack4163217756.8527305<0.01
Failure4553247157.35673420.087
INPB3933865.845027<0.01
F5First Crack223813614.2251195<0.01
Failure257813214.4285229>0.15
INPB3423684.142260.031
F2F3First Crack173643711.3195151>0.15
Failure200693412.1224176>0.15
INPB2716602.8332210.024
RD R YFirst Crack12336296.391361110.141
Failure12936286.411421170.075
INPB62360.35364<0.01
F2First Crack14747328.31631310.115
Failure15846308.19174142>0.15
INPB116490.971139<0.01
F3First Crack2271998835.1296158<0.01
Failure2372048636.1309168<0.01
INPB118711.43148<0.01
F5First Crack158654111.51801350.093
Failure173643711.41951510.022
INPB159561.51812<0.01
F2F3First Crack144634411.1166123<0.01
Failure163674111.8186140<0.01
INPB1913712.3323140.048
Table 9. Comparison of the impact strength of FRC versus plain concrete.
Table 9. Comparison of the impact strength of FRC versus plain concrete.
ParameterHUMIDDRY
F2F3F5F2F3F2F3F5F2F3
p-Value of Kruskal–Wallis testFirst Crack0.0290.0000.0000.0490.0300.0010.0210.321
Failure0.0010.0000.0000.0010.0030.0000.0020.058
INPB0.0000.0000.0000.0000.0000.0000.0000.000
First-crack strength of FRC/First crack of plain concrete1.1942.8881.5481.2011.1951.8451.2841.170
Failure strength of FRC/First crack of plain concrete1.283.0331.7131.3331.2241.8441.3411.263
INPB of FRC/INPB of plain concrete3.3336.55.6664.51.8331.8332.53.166
Table 10. The results of impact energy and the ductility index.
Table 10. The results of impact energy and the ductility index.
MixCuringImpact Energy (J)Ductility Index λ
First CrackFailure
RH U M I D2930.43052.50.042
F23500.23907.20.116
F38465.69259.250.094
F54538.055229.950.152
F2F33520.5540700.156
RD R Y2503.052625.150.049
F22991.453215.30.075
F34619.454822.950.044
F53215.33520.550.095
F2F32930.43317.050.132
Table 11. The estimation equations formulated for fracture strength.
Table 11. The estimation equations formulated for fracture strength.
MixEquations R2MixEquationsR2
R (Humid) N p f a i l = 0.9752   N f i r s t + 9.890     994R(Dry) N p f a i l = 1.002   N f i r s t + 5.313 0.996
F2 (Humid) N p f a i l = 0.9952   N f i r s t + 20.89     0.978F2 (Dry) N p f a i l = 0.9800   N f i r s t + 14.15     0.984
F3 (Humid) N p f a i l = 1.004   N f i r s t + 36.76     0.988F3 (Dry) N p f a i l = 1.028   N f i r s t + 5.106 0.998
F5 (Humid) N p f a i l = 0.9703   N f i r s t + 40.69   0.919F5 (Dry) N p f a i l = 0.9827   N f i r s t + 17.89 0.982
F2F3 (Humid) N p f a i l = 1.048   N f i r s t + 18.61 0.946F2F3 (Dry) N p f a i l = 1.038   N f i r s t + 12.99 0.855
Table 12. Efficiency of linear patterns for various types of fiber.
Table 12. Efficiency of linear patterns for various types of fiber.
Accuracy MeasuresHumidDry
RF2F3F5F2F3RF2F3F5F2F3
MAD2.2646.66925.87618.43411.7581.7364.5484.8946.3129.578
MAPE (%)1.6743.9598.8317.8996.2451.4103.1182.3134.3876.639
R20.9940.9780.9880.9190.9460.9960.9840.9980.9820.855
Table 13. Output parameters and process of experiments in previous studies.
Table 13. Output parameters and process of experiments in previous studies.
Ref.Type of FiberFiber (%)CSTSISProposed EquationsMADMAPER2p-Value of K–S Test
FCUCINPBFCUC
Mastali and Dalvand [78]RC0.2543529 N p f a i l = 1.126   N f i r s t + 3.3614 --0.90820.9990.429
0.75607717 N p f a i l = 1.2669   N f i r s t + 0.71 --0.94260.9990.512
1.257910425 N p f a i l = 1.1872   N f i r s t + 9.9145 --0.2690.6840.999
Fakharifar et al. [79]PP0.5-40488 N p f a i l = 1.27   N f i r s t 1.01 --0.94>0.15>0.15
0.75526816 N p f a i l = 1.27   N f i r s t + 1.68 --0.93>0.15>0.15
1628119 N p f a i l = 1.23   N f i r s t + 5.27 --0.94>0.15>0.15
Mastali et al. [96]RG0.25-38479 N p f a i l = 1.258   N f i r s t 0.722 --0.9650.9990.271
0.75567115 N p f a i l = 1.205   N f i r s t + 3.5999 --0.9890.9990.834
1.25769822 N p f a i l = 1.3043   N f i r s t 0.7664 --0.9910.6850.568
Rahmani et al. [21]C0.15-1121186 N p f a i l = 1.01   N f i r s t + 5.17 2.5222.2610.996>0.15>0.15
PP0.15567115 N p f a i l = 1.03   N f i r s t + 12.96 3.7376.9050.9840.012<0.010
S0.5123228105 N p f a i l = 1.60   N f i r s t 81.7937.4960.8440.0730.036
Song et al. [97]S0.5-23433096 N p f a i l = 1.189   N f i r s t + 51.569 44.36-0.9150.0000.000
S + PP0.5 + 0.1-247356109 N p f a i l = 1.008   N f i r s t + 106.887 34.73-0.8430.010.001
Rai and Singh [49]PP0.05–0.5--32527 N p f a i l = 1.7667   N f i r s t 3.4025 19.867.340.918>0.05>0.05
S0.1–1.5--9719194 N p f a i l = 1.8479   N f i r s t + 12.2438 34.4220.530.8270.0420.044
S + PP[0.2–0.5] + [0.2–0.5]--137267130 N p f a i l = 1.986   N f i r s t 7.2763 2.175.220.9870.0400.048
Song et al. [26]S1-17341896162 N p f a i l = 1.031   N f i r s t + 107.254 --0.980next to zeronext to zero
FC: first crack, UC: ultimate crack, RC: recycled carbon, PP: polypropylene, RG: recycled glass, C: cellulose, S: steel.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Mohtasham Moein, M.; Saradar, A.; Rahmati, K.; Hatami Shirkouh, A.; Sadrinejad, I.; Aramali, V.; Karakouzian, M. Investigation of Impact Resistance of High-Strength Portland Cement Concrete Containing Steel Fibers. Materials 2022, 15, 7157. https://doi.org/10.3390/ma15207157

AMA Style

Mohtasham Moein M, Saradar A, Rahmati K, Hatami Shirkouh A, Sadrinejad I, Aramali V, Karakouzian M. Investigation of Impact Resistance of High-Strength Portland Cement Concrete Containing Steel Fibers. Materials. 2022; 15(20):7157. https://doi.org/10.3390/ma15207157

Chicago/Turabian Style

Mohtasham Moein, Mohammad, Ashkan Saradar, Komeil Rahmati, Arman Hatami Shirkouh, Iman Sadrinejad, Vartenie Aramali, and Moses Karakouzian. 2022. "Investigation of Impact Resistance of High-Strength Portland Cement Concrete Containing Steel Fibers" Materials 15, no. 20: 7157. https://doi.org/10.3390/ma15207157

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.