Abstract
Two psychophysical measures of tactile sensitivity—grating-orientation (GO) and smooth-grooved (SG) discrimination—were used to determine tactile spatial acuity with and without an intermediate surface (latex glove) interposed between the contactor and the skin. Measures were made at three locations that varied in sensitivity and in density of innervation of the primary afferent fibers: the index fingerpad (fingertip), palmar surface of the proximal phalanx (fingerbase), and the thenar eminence (palm). Neurophysiological studies have suggested that the density of innervation of SAI fibers is a limiting factor in spatial acuity. In the present study, without a glove, the GO thresholds varied as a function of location. With the glove, increases in the GO thresholds were relatively uniform and modest. Without a glove, however, the SG thresholds were well below the GO thresholds, and changing the site of stimulation had little effect on the threshold. With a glove, the SG thresholds increased by 100% to more than 300% as in comparison with those in the no-glove condition. The largest increases occurred at the less sensitive locations. The results of the GO task are consistent with the view that GO is a valid measure of spatial acuity. The results of the SG task, however, are inconsistent with previous results and suggest that both spatial and intensive factors are involved in this task.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Bensel C. K. (1993). The effects of various thicknesses of chemical protective gloves on manual dexterity.Ergonomics,36, 687–696.
Brisben, A. J., Hsiao, S. S., Looft, F. J., &Johnson, K. O. (1992). Tactile recognition through intermediate surfaces.Society for Neuroscience Abstracts,18, 1545.
Burke, F. J., Watts, D. C., &Wilson, N. H. (1989). Some physical factors influencing tactile perception with disposable non-sterile gloves.Journal of Dentistry,17, 72–76.
Craig, J. C. (1999). Grating orientation as a measure of tactile spatial acuity.Somatosensory & Motor Research,16, 197–206.
Craig, J. C., &Johnson, K. O. (2000). The two-point threshold: Not a measure of tactile spatial resolution.Current Directions in Psychological Science,9, 29–32.
Craig, J. C., &Kisner, J. M. (1998). Factors affecting tactile spatial acuity.Somatosensory & Motor Research,15, 29–45.
Craig, J. C., &Lyle, K. B. (2001). A comparison of tactile spatial sensitivity on the palm and fingerpad.Perception & Psychophysics,63, 337–347.
Craig, J. C., &Lyle, K. B. (2002). A correction and a comment on Craig and Lyle (2001).Perception & Psychophysics,64, 504–506.
Cunningham, J. L., Delargy, S. M., &Warnock, C. M. (1992). Glove wearing in Northern Ireland and an assessment of the loss of tactile perception.Journal of the Irish Dental Association,38, 12–14.
Darian-Smith, I., &Kenins, P. (1980). Innervation density of mechanoreceptive fibers supplying glabrous skin of the monkey’s index finger.Journal of Physiology,309, 147–155.
Essock, E. A., Krebs, W. K., &Prather, J. R. (1997). Superior sensitivity for tactile stimuli oriented proximally-distally on the finger: Implications for mixed class 1 and class 2 anisotropies.Journal of Experimental Psychology: Human Perception & Performance,23, 515–527.
Heller, M. A., &Mitchell, B. Y. (1985). Helping new braille readers: Effects of spacing, finger locus, and gloves.Perceptual & Motor Skills,61, 363–369.
Jackson, E. M., Neal, J. G., Williams, F. M., Stern, C. A., Suber, F., Thacker, J. G., &Edlich, R. F. (1999). Biomechanical performance of orthopedic gloves.Journal of Biomedical Materials Research,48, 193–198.
Johansson, R. S., &Vallbo, A. B. (1979). Tactile sensibility in the human hand: Relative and absolute densities of four types of mechanoreceptive units in glabrous skin.Journal of Physiology,286, 283–300.
Johansson, R. S., &Westling, G. (1987). Signals in tactile afferents from the fingers eliciting adaptive motor responses during precision grip.Experimental Brain Research,66, 141–154.
Johnson, K. O., &Hsiao, S. S. (1992). Neural mechanisms of tactual form and texture perception.Annual Review of Neuroscience,15, 227–250.
Johnson, K. O., &Hsiao, S. S. (1994). Evaluation of the relative roles of slowly and rapidly adapting afferent fibers in roughness perception.Canadian Journal of Physiology & Pharmacology,72, 488–497.
Johnson, K. O., &Phillips, J. R. (1981). Tactile spatial resolution: I. Two-point discrimination, gap detection, grating resolution, and letter recognition.Journal of Neurophysiology,46, 1177–1191.
Johnson, K. O., Van Boven, R. W., &Hsiao, S. S. (1994). The perception of two points is not the spatial resolution threshold. In J. Boivie, P. Hansson, & U. Lindblom (Eds.),Touch, temperature, and pain in health and disease: Mechanisms and assessments (11th ed., pp. 389–404). Seattle: IASP.
Klatzky, R. L., &Lederman, S. J. (1999). Tactile roughness perception with a rigid link interposed between skin and surface.Perception & Psychophysics,61, 591–607.
LaMotte, R. H., &Srinivasan, M. A. (1987a). Tactile discrimination of shape: Responses of slowly adapting mechanoreceptor afferents to a step stroked across the monkey fingerpad.Journal of Neuroscience,7, 1655–1671.
LaMotte, R. H., &Srinivasan, M. A. (1987b). Tactile discrimination of shape: Responses of rapidly adapting mechanoreceptive afferents to a step stroked across the monkey fingerpad.Journal of Neuroscience,7, 1672–1681.
Loomis, J. M., &Lederman, S. J. (1986). Tactual perception. In K. R. Boff, L. Kaufman, & J. P. Thomas(Eds.),Handbook of perception and human performance (Vol. 31, pp. 1–41). New York: Wiley.
Nelson, J. B., &Mital, A. (1995). An ergonomic evaluation of dexterity and tactility with increase in examination/surgical glove thickness.Ergonomics,38, 723–733.
Novak, C. B., Patterson, J. M., &Mackinnon, S. E. (1999). Evaluation of hand sensibility with single and double latex gloves.Plastic & Reconstructive Surgery,103, 128–131.
Patel, J., Essick, G. K., &Kelly, D. G. (1997). Utility of square-wave gratings to assess perioral spatial acuity.Journal of Oral & Maxillofacial Surgery,55, 593–601.
Phillips, A. M., Birch, N. C., &Ribbans, W. J. (1997). Protective gloves for use in high-risk patients: How much do they affect the dexterity of the surgeon?Annals of the Royal College of Surgeons of England,79, 124–127.
Phillips, J. R., &Johnson, K. O. (1981a). Tactile spatial resolution: II. Neural representation of bars, edges, and gratings in monkey primary afferents.Journal of Neurophysiology,46, 1192–1203.
Phillips, J. R., &Johnson, K. O. (1981b). Tactile spatial resolution: III. A continuum mechanics model of skin predicting mechanoreceptor responses to bars, edges, and gratings.Journal of Neurophysiology,46, 1204–1225.
Sathian, K., &Zangaladze, A. (1996). Tactile spatial acuity at the human fingertip and lip: Bilateral symmetry and interdigit variability.Neurology,46, 1464–1466.
Stevens, J. C. (1990). Perceived roughness as a function of body locus.Perception & Psychophysics,47, 298–304.
Stevens, J. C., &Choo, K. K. (1996). Spatial acuity of the body surface over the life span.Somatosensory & Motor Research,13, 153–166.
Stevens, J. C., &Patterson, M. Q. (1995). Dimensions of spatial acuity in the touch sense: Changes over the life span.Somatosensory & Motor Research,12, 29–47.
Taylor, M. M., &Lederman, S. J. (1975). Tactile roughness of grooved surfaces: A model and the effect of friction.Perception & Psychophysics,17, 23–36.
Thompson, P. B., &Lambert, J. V. (1995). Touch sensitivity through latex examination gloves.Journal of General Psychology,122, 47–58.
Van Boven, R. W., &Johnson, K. O. (1994a). The limit of tactile spatial resolution in humans: Grating orientation discrimination at the lip, tongue, and finger.Neurology,44, 2361–2366.
Van Boven, R. W., &Johnson, K. O. (1994b). A psychophysical study of the mechanisms of sensory recovery following nerve injury in humans.Brain,117 (Pt. 1), 149–167.
Webb, J. M., &Pentlow, B. D. (1993). Double gloving and surgical technique.Annals of the Royal College of Surgeons of England,75, 291–292.
Wheat, H. E., &Goodwin, A. W. (2000). Tactile discrimination of gaps by slowly adapting afferents: Effects of population parameters and anisotropy in the fingerpad.Journal of Neurophysiology,84, 1430–1444.
Wilson, M. P., Gound, S., Tishk, M., &Feil, P. (1986). Gloved versus ungloved dental hygiene clinicians: A comparison of tactile discrimination.Dental Hygiene,60, 310–315.
Wilson, S. J., Sellu, D., Uy, A., &Jaffer, M. A. (1996). Subjective effects of double gloves on surgical performance.Annals of the Royal College of Surgeons of England,78, 20–22.
Woods, J. A., Leslie, L. F., Drake, D. B., &Edlich, R. F. (1996). Effect of puncture resistant surgical gloves, finger guards, and glove liners on cutaneous sensibility and surgical psychomotor skills.Journal of Biomedical Materials Research,33, 47–51.
Author information
Authors and Affiliations
Corresponding author
Additional information
This research was supported by the National Institutes of Health Grant DC 00095, National Institute on Deafness and Other Communication Disorders.
Rights and permissions
About this article
Cite this article
Gibson, G.O., Craig, J.C. Relative roles of spatial and intensive cues in the discrimination of spatial tactile stimuli. Perception & Psychophysics 64, 1095–1107 (2002). https://doi.org/10.3758/BF03194759
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.3758/BF03194759