Abstract:

Pre-clinical experimental wear testing is very effective to evaluate new ankle replacement in the aspect of design and material used. However, both cost and time can be one of the constraints factors, particularly in the early stage of design or analysis. Numerical method has been addressed as an alternative to predict wear on ankle replacement. The computational wear simulation has been widely used on the hip and knee but very less found in study related to wear analysis of the ankle. The purpose of this research is to develop computational simulation to predict wear on total ankle replacement (TAR). Three dimensional (3D) models of the right ankle TAR were developed using BOX total ankle replacement model. Mobile bearing device was developed consisting of three components tibial, bearing and talar. Each component has different design and purposes representing its physiological behaviour of the ankle. The ankle load applied was based on the joint reaction force profile at the ankle joint. This is to determine the distribution of contact stress on the meniscal bearing surfaces contact with talar component for 25 discrete instant during stance phase of gait cycle. The sliding distance was obtained from predominates motion of plantar/dorsi flexion. The computed linear wear depth and cumulative volumetric wear were 0.01614 mm per million cycles and 30.5 mm3, respectively. The values obtained were proven to be consistent with the previous in vitro result.

You might also be interested in these eBooks

Info:

Periodical:

Pages:

311-315

Citation:

Online since:

December 2013

Export:

Price:

* - Corresponding Author

[1] E. Ingham and J. Fisher, The role of macrophages in osteolysis of total joint replacement., Biomaterials, vol. 26, no. 11, , Apr. (2005), p.1271–86.

DOI: 10.1016/j.biomaterials.2004.04.035

Google Scholar

[2] Leardini, A., L. Rapagnà, et al. Computer-assisted preoperative planning of a novel design of total ankle replacement., Computer Methods and Programs in Biomedicine 67(3): 231-243, (2002).

DOI: 10.1016/s0169-2607(01)00150-x

Google Scholar

[3] Leardini, A., O'Connor, J.J., Catani, F., Giannini, S. Mobility of the human ankle and the design of total ankle replacement. Clinical Orthopaedics and Related Research 424, 39–46, (2004).

DOI: 10.1097/01.blo.0000132246.26172.b7

Google Scholar

[4] Affatato, S., A. Leardini, et al. Meniscal wear at a three-component total ankle prosthesis by a knee joint simulator., Journal of Biomechanics 40(8): 1871-1876, (2007).

DOI: 10.1016/j.jbiomech.2006.08.002

Google Scholar

[5] R. Daud, M. R. Abdul Kadir, S. Izman, A. P. Md Saad, M. H. Lee, and A. Che Ahmad, Three-Dimensional Morphometric Study of the Trapezium Shape of the Trochlea Tali., The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons, p.1–6, Apr. (2013).

DOI: 10.1053/j.jfas.2013.03.007

Google Scholar

[6] Vickerstaff, J. A., A. W. Miles, et al. A brief history of total ankle replacement and a review of the current status., Medical Engineering & Physics29(10): 1056-1064. (2007).

DOI: 10.1016/j.medengphy.2006.11.009

Google Scholar

[7] R. M. A. Raja Izaham, et al., Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy, Injury, vol. 43, pp.898-902, (2012).

DOI: 10.1016/j.injury.2011.12.006

Google Scholar

[8] M. Kadir, et al., Finite element analysis of idealised unit cell cancellous structure based on morphological indices of cancellous bone, Medical & Biological Engineering & Computing, vol. 48, pp.497-505, (2010).

DOI: 10.1007/s11517-010-0593-2

Google Scholar

[9] S. Saidin, et al., Effects of different implant–abutment connections on micromotion and stress distribution: Prediction of microgap formation, Journal of Dentistry, vol. 40, pp.467-474, (2012).

DOI: 10.1016/j.jdent.2012.02.009

Google Scholar

[10] M. Abdul Kadir, et al., Interface Micromotion of Cementless Hip Arthroplasty: Collared vs Non-collared Stems, in 4th Kuala Lumpur International Conference on Biomedical Engineering 2008. vol. 21, N. Abu Osman, et al., Eds., ed: Springer Berlin Heidelberg, pp.428-432, (2008).

DOI: 10.1007/978-3-540-69139-6_109

Google Scholar

[11] F. C. Wang, Z. M. Jin, H. M. J. McEwen, and J. Fisher, Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, vol. 217, no. 6, p.477–490, Jun. (2003).

DOI: 10.1243/09544110360729117

Google Scholar

[12] A. Ianuzzi and C. Mkandawire, Applications of UHMWPE in Total Ankle Replacements, Second Edi. Elsevier Inc., 2006, p.153–169.

DOI: 10.1016/b978-0-12-374721-1.00011-0

Google Scholar

[13] A. Leardini, J. J. O'Connor, F. Catani, and S. Giannini, Mobility of the Human Ankle and the Design of Total Ankle Replacement, Clinical Orthopaedics and Related Research, vol. 424, (2004).

DOI: 10.1097/01.blo.0000132246.26172.b7

Google Scholar

[14] A C. Godest, M. Beaugonin, E. Haug, M. Taylor, and P. J. Gregson, Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis., Journal of biomechanics, vol. 35, no. 2, p.267–75, Feb. (2002).

DOI: 10.1016/s0021-9290(01)00179-8

Google Scholar

[15] A. Seireg and R. J. Arvikar, The prediction of muscular load sharing and joint forces in the lower extremities during walking, Journal of Biomechanics, vol. 8, no. 2, p.89–102, Mar. (1975).

DOI: 10.1016/0021-9290(75)90089-5

Google Scholar

[16] Procter P and Paul JP, Ankle Joint biomechanics., J. Biomech, pp. Vol 15, p.627–634, (1982).

Google Scholar

[17] L. A. Knight, S. Pal, J. C. Coleman, F. Bronson, H. Haider, D. L. Levine, M. Taylor, and P. J. Rullkoetter, Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading, Journal of Biomechanics, vol. 40, no. 7, p.1550–1558, (2007).

DOI: 10.1016/j.jbiomech.2006.07.027

Google Scholar

[18] T. P. Schmalzried, E. F. Shepherd, F. J. Dorey, W. O. Jackson, M. dela Rosa, F. Fa'vae, H. A. McKellop, C. D. McClung, J. Martell, J. R. Moreland, and H. C. Amstutz, Wear is a Function of Use, Not Time, Clinical Orthopaedics and Related Research, vol. 381, (2000).

DOI: 10.1097/00003086-200012000-00005

Google Scholar

[19] B. Reggiani, a Leardini, F. Corazza, and M. Taylor, Finite element analysis of a total ankle replacement during the stance phase of gait., Journal of biomechanics, vol. 39, no. 8, p.1435–43, Jan. (2006).

DOI: 10.1016/j.jbiomech.2005.04.010

Google Scholar