Abstract

Cell manipulation is one of the fastest growing segments of biotechnology engineering, and magnetic cell separation plays a large part in its development. Because of low magnetic permeability of biological materials, the magnetostatic forces can be made to operate highly selectively on cells tagged with magnetic nanoparticles, with no interference from the physiological electrolyte solutions used for cell suspension and from other cells. The increasing availability of inexpensive permanent magnet blocks capable of generating fields in excess of 1 tesla (T) and gradients up to 1000 T/m combined with a large selection of targeting antibodies against nearly all cell surface markers of interest in clinical and laboratory applications, together with high-quality superparamagnetic iron oxide nanoparticles, makes magnetic separation an appealing alternative to other cell separation methods, including centrifugation and fluorescence-activated cell sorting. This chapter provides a brief overview of the underlying physical principles and a number of examples selected from a large body of scientific literature published on the subject.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Buck A, Moore LR, Lane CD, Kumar A, Stroff C, White N, Xue W, Chalmers JJ, Zborowski M (2015) Magnetic separation of algae genetically modified for increased intracellular iron uptake. J Magn Magn Mater 380:201–204. doi:10.1016/j.jmmm.2014.09.008 CrossRef Buck A, Moore LR, Lane CD, Kumar A, Stroff C, White N, Xue W, Chalmers JJ, Zborowski M (2015) Magnetic separation of algae genetically modified for increased intracellular iron uptake. J Magn Magn Mater 380:201–204. doi:10.​1016/​j.​jmmm.​2014.​09.​008 CrossRef
Zurück zum Zitat Caralla T, Joshi P, Fleury S, Luangphakdy V, Shinohara K, Pan H, Boehm C, Vasanji A, Hefferan TE, Walker E, Yaszemski M, Hascall V, Zborowski M, Muschler GF (2013) In vivo transplantation of autogenous marrow-derived cells following rapid intraoperative magnetic separation based on hyaluronan to augment bone regeneration. Tissue Eng Part A 19(1–2):125–134. doi:10.1089/ten.tea.2011.0622 CrossRef Caralla T, Joshi P, Fleury S, Luangphakdy V, Shinohara K, Pan H, Boehm C, Vasanji A, Hefferan TE, Walker E, Yaszemski M, Hascall V, Zborowski M, Muschler GF (2013) In vivo transplantation of autogenous marrow-derived cells following rapid intraoperative magnetic separation based on hyaluronan to augment bone regeneration. Tissue Eng Part A 19(1–2):125–134. doi:10.​1089/​ten.​tea.​2011.​0622 CrossRef
Zurück zum Zitat Chalmers JJ, Xiong Y, Jin X, Shao M, Tong X, Farag S, Zborowski M (2010) Quantification of non-specific binding of magnetic micro- and nanoparticles using cell tracking velocimetry: implication for magnetic cell separation and detection. Biotechnol Bioeng 105(6):1078–1093. doi:10.1002/bit.22635 Chalmers JJ, Xiong Y, Jin X, Shao M, Tong X, Farag S, Zborowski M (2010) Quantification of non-specific binding of magnetic micro- and nanoparticles using cell tracking velocimetry: implication for magnetic cell separation and detection. Biotechnol Bioeng 105(6):1078–1093. doi:10.​1002/​bit.​22635
Zurück zum Zitat Chen A, Byvank T, Chang WJ, Bharde A, Vieira G, Miller BL, Chalmers JJ, Bashir R, Sooryakumar R (2013) On-chip magnetic separation and encapsulation of cells in droplets. Lab Chip 13(6):1172–1181. doi:10.1039/c2lc41201b CrossRef Chen A, Byvank T, Chang WJ, Bharde A, Vieira G, Miller BL, Chalmers JJ, Bashir R, Sooryakumar R (2013) On-chip magnetic separation and encapsulation of cells in droplets. Lab Chip 13(6):1172–1181. doi:10.​1039/​c2lc41201b CrossRef
Zurück zum Zitat de Wit S, van Dalum G, Lenferink AT, Tibbe AG, Hiltermann TJ, Groen HJ, van Rijn CJ, Terstappen LW (2015) The detection of EpCAM(+) and EpCAM(−) circulating tumor cells. Sci Rep 5:12270. doi:10.1038/srep12270 CrossRef de Wit S, van Dalum G, Lenferink AT, Tibbe AG, Hiltermann TJ, Groen HJ, van Rijn CJ, Terstappen LW (2015) The detection of EpCAM(+) and EpCAM(−) circulating tumor cells. Sci Rep 5:12270. doi:10.​1038/​srep12270 CrossRef
Zurück zum Zitat Doctor RD, Panchal CB, Swietlik CE (1986) A model of open-gradient magnetic separation for coal cleaning using a superconducting quadrupole field. AIChE Symp Ser 82:154–168 Doctor RD, Panchal CB, Swietlik CE (1986) A model of open-gradient magnetic separation for coal cleaning using a superconducting quadrupole field. AIChE Symp Ser 82:154–168
Zurück zum Zitat Fukui S, Nakajima H, Ozone A, Hayatsu M, Yamaguchi M, Sato T, Imaizumi H, Nishijima S, Watanabe T (2002) Study on open gradient magnetic separation using multiple magnetic field sources. IEEE Trans Appl Supercond 12(1):959–962. doi:10.1109/TASC.2002.1018559 CrossRef Fukui S, Nakajima H, Ozone A, Hayatsu M, Yamaguchi M, Sato T, Imaizumi H, Nishijima S, Watanabe T (2002) Study on open gradient magnetic separation using multiple magnetic field sources. IEEE Trans Appl Supercond 12(1):959–962. doi:10.​1109/​TASC.​2002.​1018559 CrossRef
Zurück zum Zitat Furlani EP (2001) Permanent magnet and electromechanical devices: materials, analysis, and applications. Academic Press, San Diego Furlani EP (2001) Permanent magnet and electromechanical devices: materials, analysis, and applications. Academic Press, San Diego
Zurück zum Zitat Gao L, Ct Wyatt Shields, Johnson LM, Graves SW, Yellen BB, Lopez GP (2015) Two-dimensional spatial manipulation of microparticles in continuous flows in acoustofluidic systems. Biomicrofluidics 9(1):014105. doi:10.1063/1.4905875 CrossRef Gao L, Ct Wyatt Shields, Johnson LM, Graves SW, Yellen BB, Lopez GP (2015) Two-dimensional spatial manipulation of microparticles in continuous flows in acoustofluidic systems. Biomicrofluidics 9(1):014105. doi:10.​1063/​1.​4905875 CrossRef
Zurück zum Zitat Giddings JC (1985) Optimized field-flow fractionation system based on dual stream splitters. Anal Chem 57(4):945–947CrossRef Giddings JC (1985) Optimized field-flow fractionation system based on dual stream splitters. Anal Chem 57(4):945–947CrossRef
Zurück zum Zitat Gider S, Awschalom DD, Douglas T, Mann S, Chaparala M (1995) Classical and quantum magnetic phenomena in natural and artificial ferritin proteins. Science 268(5207):77–80CrossRef Gider S, Awschalom DD, Douglas T, Mann S, Chaparala M (1995) Classical and quantum magnetic phenomena in natural and artificial ferritin proteins. Science 268(5207):77–80CrossRef
Zurück zum Zitat Gijs MA, Lacharme F, Lehmann U (2010) Microfluidic applications of magnetic particles for biological analysis and catalysis. Chem Rev 110(3):1518–1563. doi:10.1021/cr9001929 CrossRef Gijs MA, Lacharme F, Lehmann U (2010) Microfluidic applications of magnetic particles for biological analysis and catalysis. Chem Rev 110(3):1518–1563. doi:10.​1021/​cr9001929 CrossRef
Zurück zum Zitat Grützkau A, Radbruch A (2010) Small but mighty: how the MACS®-technology based on nanosized superparamagnetic particles has helped to analyze the immune system within the last 20 years. Cytometry Part A 77A(7):643–647. doi:10.1002/cyto.a.20918 CrossRef Grützkau A, Radbruch A (2010) Small but mighty: how the MACS®-technology based on nanosized superparamagnetic particles has helped to analyze the immune system within the last 20 years. Cytometry Part A 77A(7):643–647. doi:10.​1002/​cyto.​a.​20918 CrossRef
Zurück zum Zitat Gutierrez L, Costo R, Gruttner C, Westphal F, Gehrke N, Heinke D, Fornara A, Pankhurst QA, Johansson C, Veintemillas-Verdaguer S, Morales MP (2015) Synthesis methods to prepare single- and multi-core iron oxide nanoparticles for biomedical applications. Dalton Trans 44(7):2943–2952. doi:10.1039/c4dt03013c CrossRef Gutierrez L, Costo R, Gruttner C, Westphal F, Gehrke N, Heinke D, Fornara A, Pankhurst QA, Johansson C, Veintemillas-Verdaguer S, Morales MP (2015) Synthesis methods to prepare single- and multi-core iron oxide nanoparticles for biomedical applications. Dalton Trans 44(7):2943–2952. doi:10.​1039/​c4dt03013c CrossRef
Zurück zum Zitat Hackett S, Hamzah J, Davis TM, St Pierre TG (2009) Magnetic susceptibility of iron in malaria-infected red blood cells. Biochim Biophys Acta 1792(2):93–99CrossRef Hackett S, Hamzah J, Davis TM, St Pierre TG (2009) Magnetic susceptibility of iron in malaria-infected red blood cells. Biochim Biophys Acta 1792(2):93–99CrossRef
Zurück zum Zitat Hafeli UO, Aue J, Damani J (2008) The biocompatibility and toxicity of magnetic particles. In: Zborowski M, Chalmers JJ (eds) Magnetic cell separation. Elsevier B.V., Amsterdam Hafeli UO, Aue J, Damani J (2008) The biocompatibility and toxicity of magnetic particles. In: Zborowski M, Chalmers JJ (eds) Magnetic cell separation. Elsevier B.V., Amsterdam
Zurück zum Zitat Hatch GP, Stelter RE (2001) Magnetic design considerations for devices and particles used for biological high-gradient magnetic separation (HGMS) systems. J Magn Magn Mater 225(1–2):262–276. doi:10.1016/S0304-8853(00)01250-6 CrossRef Hatch GP, Stelter RE (2001) Magnetic design considerations for devices and particles used for biological high-gradient magnetic separation (HGMS) systems. J Magn Magn Mater 225(1–2):262–276. doi:10.​1016/​S0304-8853(00)01250-6 CrossRef
Zurück zum Zitat Hirota N, Kurashige M, Iwasaka M, Ikehata M, Uetake H, Takayama T, Nakamura H, Ikezoe Y, Ueno S, Kitazawa K (2004) Magneto-Archimedes separation and its application to the separation of biological materials. Phys B 346:267–271. doi:10.1016/j.physb.2004.01.063 CrossRef Hirota N, Kurashige M, Iwasaka M, Ikehata M, Uetake H, Takayama T, Nakamura H, Ikezoe Y, Ueno S, Kitazawa K (2004) Magneto-Archimedes separation and its application to the separation of biological materials. Phys B 346:267–271. doi:10.​1016/​j.​physb.​2004.​01.​063 CrossRef
Zurück zum Zitat Hu X, Abedini-Nassab R, Lim B, Yang Y, Howdyshell M, Sooryakumar R, Yellen BB, Kim C (2015) Dynamic trajectory analysis of superparamagnetic beads driven by on-chip micromagnets. J Appl Phys 118(20):203904. doi:10.1063/1.4936219 CrossRef Hu X, Abedini-Nassab R, Lim B, Yang Y, Howdyshell M, Sooryakumar R, Yellen BB, Kim C (2015) Dynamic trajectory analysis of superparamagnetic beads driven by on-chip micromagnets. J Appl Phys 118(20):203904. doi:10.​1063/​1.​4936219 CrossRef
Zurück zum Zitat Hwang JY, Takayasu M, Friedlaender FJ, Kullerud G (1984) Application of magnetic susceptibility gradients to magnetic separation. J Appl Phys 55(6):2592–2594CrossRef Hwang JY, Takayasu M, Friedlaender FJ, Kullerud G (1984) Application of magnetic susceptibility gradients to magnetic separation. J Appl Phys 55(6):2592–2594CrossRef
Zurück zum Zitat Jakubovics JP (1994) Magnetism and magnetic materials. Cambridge University Press, Cambridge Jakubovics JP (1994) Magnetism and magnetic materials. Cambridge University Press, Cambridge
Zurück zum Zitat Jiles D (2016) Introduction to magnetism and magnetic materials, 3rd edn. CRC Press, Boca Raton Jiles D (2016) Introduction to magnetism and magnetic materials, 3rd edn. CRC Press, Boca Raton
Zurück zum Zitat Jin X, Zhao Y, Richardson A, Moore L, Williams PS, Zborowski M, Chalmers JJ (2008) Differences in magnetically induced motion of diamagnetic, paramagnetic, and superparamagnetic microparticles detected by cell tracking velocimetry. Analyst 133(12):1767–1775. doi:10.1039/b802113a CrossRef Jin X, Zhao Y, Richardson A, Moore L, Williams PS, Zborowski M, Chalmers JJ (2008) Differences in magnetically induced motion of diamagnetic, paramagnetic, and superparamagnetic microparticles detected by cell tracking velocimetry. Analyst 133(12):1767–1775. doi:10.​1039/​b802113a CrossRef
Zurück zum Zitat Jin X, Yazer MH, Chalmers JJ, Zborowski M (2011) Quantification of changes in oxygen release from red blood cells as a function of age based on magnetic susceptibility measurements. Analyst 136(14):2996–3003CrossRef Jin X, Yazer MH, Chalmers JJ, Zborowski M (2011) Quantification of changes in oxygen release from red blood cells as a function of age based on magnetic susceptibility measurements. Analyst 136(14):2996–3003CrossRef
Zurück zum Zitat Jin X, Abbot S, Zhang X, Kang L, Voskinarian-Berse V, Zhao R, Kameneva MV, Moore LR, Chalmers JJ, Zborowski M (2012) Erythrocyte enrichment in hematopoietic progenitor cell cultures based on magnetic susceptibility of the hemoglobin. PLoS One 7(8):e39491CrossRef Jin X, Abbot S, Zhang X, Kang L, Voskinarian-Berse V, Zhao R, Kameneva MV, Moore LR, Chalmers JJ, Zborowski M (2012) Erythrocyte enrichment in hematopoietic progenitor cell cultures based on magnetic susceptibility of the hemoglobin. PLoS One 7(8):e39491CrossRef
Zurück zum Zitat Joshi P, Williams PS, Moore LR, Caralla T, Boehm C, Muschler G, Zborowski M (2015) Circular Halbach array for fast magnetic separation of hyaluronan-expressing tissue progenitors. Anal Chem 87(19):9908–9915. doi:10.1021/acs.analchem.5b02431 CrossRef Joshi P, Williams PS, Moore LR, Caralla T, Boehm C, Muschler G, Zborowski M (2015) Circular Halbach array for fast magnetic separation of hyaluronan-expressing tissue progenitors. Anal Chem 87(19):9908–9915. doi:10.​1021/​acs.​analchem.​5b02431 CrossRef
Zurück zum Zitat Kantor AB, Gibbons I, Miltenyi S, Schmitz J (1998) Magnetic cell sorting with colloidal superparamagnetic particles. In: Recktenwald D, Radbruch A (eds) Cell separation methods and applications. Marcel Dekker, New York, pp 153–173 Kantor AB, Gibbons I, Miltenyi S, Schmitz J (1998) Magnetic cell sorting with colloidal superparamagnetic particles. In: Recktenwald D, Radbruch A (eds) Cell separation methods and applications. Marcel Dekker, New York, pp 153–173
Zurück zum Zitat Karabacak NM, Spuhler PS, Fachin F, Lim EJ, Pai V, Ozkumur E, Martel JM, Kojic N, Smith K, Chen PI, Yang J, Hwang H, Morgan B, Trautwein J, Barber TA, Stott SL, Maheswaran S, Kapur R, Haber DA, Toner M (2014) Microfluidic, marker-free isolation of circulating tumor cells from blood samples. Nat Protoc 9(3):694–710. doi:10.1038/nprot.2014.044 CrossRef Karabacak NM, Spuhler PS, Fachin F, Lim EJ, Pai V, Ozkumur E, Martel JM, Kojic N, Smith K, Chen PI, Yang J, Hwang H, Morgan B, Trautwein J, Barber TA, Stott SL, Maheswaran S, Kapur R, Haber DA, Toner M (2014) Microfluidic, marker-free isolation of circulating tumor cells from blood samples. Nat Protoc 9(3):694–710. doi:10.​1038/​nprot.​2014.​044 CrossRef
Zurück zum Zitat Karl S, David M, Moore L, Grimberg BT, Michon P, Mueller I, Zborowski M, Zimmerman PA (2008) Enhanced detection of gametocytes by magnetic deposition microscopy predicts higher potential for Plasmodium falciparum transmission. Malar J 7:66CrossRef Karl S, David M, Moore L, Grimberg BT, Michon P, Mueller I, Zborowski M, Zimmerman PA (2008) Enhanced detection of gametocytes by magnetic deposition microscopy predicts higher potential for Plasmodium falciparum transmission. Malar J 7:66CrossRef
Zurück zum Zitat Karle M, Miwa J, Czilwik G, Auwarter V, Roth G, Zengerle R, von Stetten F (2010) Continuous microfluidic DNA extraction using phase-transfer magnetophoresis. Lab Chip 10(23):3284–3290. doi:10.1039/c0lc00129e CrossRef Karle M, Miwa J, Czilwik G, Auwarter V, Roth G, Zengerle R, von Stetten F (2010) Continuous microfluidic DNA extraction using phase-transfer magnetophoresis. Lab Chip 10(23):3284–3290. doi:10.​1039/​c0lc00129e CrossRef
Zurück zum Zitat Krishnan KM (2016) Fundamentals and applications of magnetic materials. Oxford University Press, Oxford, UK Krishnan KM (2016) Fundamentals and applications of magnetic materials. Oxford University Press, Oxford, UK
Zurück zum Zitat Lara O, Tong X, Zborowski M, Farag SS, Chalmers JJ (2006) Comparison of two technologies to deplete T cells from human blood samples. Biotechnol Bioeng 94(1):66–80. doi:10.1002/bit.20807 CrossRef Lara O, Tong X, Zborowski M, Farag SS, Chalmers JJ (2006) Comparison of two technologies to deplete T cells from human blood samples. Biotechnol Bioeng 94(1):66–80. doi:10.​1002/​bit.​20807 CrossRef
Zurück zum Zitat Leigh DR, Steinert S, Moore LR, Chalmers JJ, Zborowski M (2005) Cell tracking velocimetry as a tool for defining saturation binding of magnetically conjugated antibodies. Cytometry Part A J Int Soc Anal Cytol 66(2):103–108. doi:10.1002/cyto.a.20155 CrossRef Leigh DR, Steinert S, Moore LR, Chalmers JJ, Zborowski M (2005) Cell tracking velocimetry as a tool for defining saturation binding of magnetically conjugated antibodies. Cytometry Part A J Int Soc Anal Cytol 66(2):103–108. doi:10.​1002/​cyto.​a.​20155 CrossRef
Zurück zum Zitat Mahajan KD, Vieira GB, Ruan G, Miller BL, Lustberg MB, Chalmers JJ, Sooryakumar R, Winter JO (2012) A MagDot-nanoconveyor assay detects and isolates molecular biomarkers. Chem Eng Prog 108:41–46 Mahajan KD, Vieira GB, Ruan G, Miller BL, Lustberg MB, Chalmers JJ, Sooryakumar R, Winter JO (2012) A MagDot-nanoconveyor assay detects and isolates molecular biomarkers. Chem Eng Prog 108:41–46
Zurück zum Zitat McCloskey KE, Chalmers JJ, Zborowski M (2000) Magnetophoretic mobilities correlate to antibody binding capacities. Cytometry 40(4):307–315CrossRef McCloskey KE, Chalmers JJ, Zborowski M (2000) Magnetophoretic mobilities correlate to antibody binding capacities. Cytometry 40(4):307–315CrossRef
Zurück zum Zitat Melnik K, Sun J, Fleischman A, Roy S, Zborowski M, Chalmers JJ (2007) Quantification of magnetic susceptibility in several strains of Bacillus spores: implications for separation and detection. Biotechnol Bioeng 98(1):186–192. doi:10.1002/bit.21400 CrossRef Melnik K, Sun J, Fleischman A, Roy S, Zborowski M, Chalmers JJ (2007) Quantification of magnetic susceptibility in several strains of Bacillus spores: implications for separation and detection. Biotechnol Bioeng 98(1):186–192. doi:10.​1002/​bit.​21400 CrossRef
Zurück zum Zitat Mirica KA, Shevkoplyas SS, Phillips ST, Gupta M, Whitesides GM (2009) Measuring densities of solids and liquids using magnetic levitation: fundamentals. J Am Chem Soc 131(29):10049–10058. doi:10.1021/ja900920s CrossRef Mirica KA, Shevkoplyas SS, Phillips ST, Gupta M, Whitesides GM (2009) Measuring densities of solids and liquids using magnetic levitation: fundamentals. J Am Chem Soc 131(29):10049–10058. doi:10.​1021/​ja900920s CrossRef
Zurück zum Zitat Mirica KA, Phillips ST, Mace CR, Whitesides GM (2010) Magnetic levitation in the analysis of foods and water. J Agric Food Chem 58(11):6565–6569. doi:10.1021/jf100377n CrossRef Mirica KA, Phillips ST, Mace CR, Whitesides GM (2010) Magnetic levitation in the analysis of foods and water. J Agric Food Chem 58(11):6565–6569. doi:10.​1021/​jf100377n CrossRef
Zurück zum Zitat Moore LR, Milliron S, Williams PS, Chalmers JJ, Margel S, Zborowski M (2004) Control of magnetophoretic mobility by susceptibility-modified solutions as evaluated by cell tracking velocimetry and continuous magnetic sorting. Anal Chem 76(14):3899–3907. doi:10.1021/ac049910f CrossRef Moore LR, Milliron S, Williams PS, Chalmers JJ, Margel S, Zborowski M (2004) Control of magnetophoretic mobility by susceptibility-modified solutions as evaluated by cell tracking velocimetry and continuous magnetic sorting. Anal Chem 76(14):3899–3907. doi:10.​1021/​ac049910f CrossRef
Zurück zum Zitat Nath P, Strelnik J, Vasanji A, Moore LR, Williams PS, Zborowski M, Roy S, Fleischman AJ (2009) Development of multistage magnetic deposition microscopy. Anal Chem 81(1):43–49. doi:10.1021/ac8010186 CrossRef Nath P, Strelnik J, Vasanji A, Moore LR, Williams PS, Zborowski M, Roy S, Fleischman AJ (2009) Development of multistage magnetic deposition microscopy. Anal Chem 81(1):43–49. doi:10.​1021/​ac8010186 CrossRef
Zurück zum Zitat Osman O, Zanini LF, Frenea-Robin M, Dumas-Bouchiat F, Dempsey NM, Reyne G, Buret F, Haddour N (2012) Monitoring the endocytosis of magnetic nanoparticles by cells using permanent micro-flux sources. Biomed Microdev 14(5):947–954. doi:10.1007/s10544-012-9673-4 CrossRef Osman O, Zanini LF, Frenea-Robin M, Dumas-Bouchiat F, Dempsey NM, Reyne G, Buret F, Haddour N (2012) Monitoring the endocytosis of magnetic nanoparticles by cells using permanent micro-flux sources. Biomed Microdev 14(5):947–954. doi:10.​1007/​s10544-012-9673-4 CrossRef
Zurück zum Zitat Pamme N, Manz A (2004) On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates. Anal Chem 76(24):7250–7256. doi:10.1021/ac049183o CrossRef Pamme N, Manz A (2004) On-chip free-flow magnetophoresis: continuous flow separation of magnetic particles and agglomerates. Anal Chem 76(24):7250–7256. doi:10.​1021/​ac049183o CrossRef
Zurück zum Zitat Pauling L, Coryell CD (1936) The magnetic properties and structure of hemoglobin, oxyhemoglobin and carbonmonoxyhemoglobin. Proc Natl Acad Sci USA 22(4):210–216CrossRef Pauling L, Coryell CD (1936) The magnetic properties and structure of hemoglobin, oxyhemoglobin and carbonmonoxyhemoglobin. Proc Natl Acad Sci USA 22(4):210–216CrossRef
Zurück zum Zitat Ramsey NF (1990) Molecular beams. The international series of monographs on physics. Oxford University Press, Oxford Ramsey NF (1990) Molecular beams. The international series of monographs on physics. Oxford University Press, Oxford
Zurück zum Zitat Rosensweig RE (1997) Ferrohydrodynamics. Dover, Mineola Rosensweig RE (1997) Ferrohydrodynamics. Dover, Mineola
Zurück zum Zitat Russell AP, Evans CH, Westcott VC (1987) Measurement of the susceptibility of paramagnetically labeled cells with paramagnetic solutions. Anal Biochem 164:181–189CrossRef Russell AP, Evans CH, Westcott VC (1987) Measurement of the susceptibility of paramagnetically labeled cells with paramagnetic solutions. Anal Biochem 164:181–189CrossRef
Zurück zum Zitat Sahore V, Fritsch I (2014) Redox-magnetohydrodynamics, flat flow profile-guided enzyme assay detection: toward multiple, parallel analyses. Anal Chem 86(19):9405–9411. doi:10.1021/ac502014t CrossRef Sahore V, Fritsch I (2014) Redox-magnetohydrodynamics, flat flow profile-guided enzyme assay detection: toward multiple, parallel analyses. Anal Chem 86(19):9405–9411. doi:10.​1021/​ac502014t CrossRef
Zurück zum Zitat Schneider T, Karl S, Moore LR, Chalmers JJ, Williams PS, Zborowski M (2010) Sequential CD34 cell fractionation by magnetophoresis in a magnetic dipole flow sorter. Analyst 135(1):62–70. doi:10.1039/b908210g CrossRef Schneider T, Karl S, Moore LR, Chalmers JJ, Williams PS, Zborowski M (2010) Sequential CD34 cell fractionation by magnetophoresis in a magnetic dipole flow sorter. Analyst 135(1):62–70. doi:10.​1039/​b908210g CrossRef
Zurück zum Zitat Schwinger J, DeRaad LLJ, Milton KA, W-y Tsai (1998) Classical electrodynamics. Perseus Books, Reading Schwinger J, DeRaad LLJ, Milton KA, W-y Tsai (1998) Classical electrodynamics. Perseus Books, Reading
Zurück zum Zitat Shen F, Hwang H, Hahn YK, Park JK (2012) Label-free cell separation using a tunable magnetophoretic repulsion force. Anal Chem 84(7):3075–3081. doi:10.1021/ac201505j CrossRef Shen F, Hwang H, Hahn YK, Park JK (2012) Label-free cell separation using a tunable magnetophoretic repulsion force. Anal Chem 84(7):3075–3081. doi:10.​1021/​ac201505j CrossRef
Zurück zum Zitat Simon MD, Geim AK (2000) Diamagnetic levitation: flying frogs and floating magnets (invited). J Appl Phys 87:6200–6204CrossRef Simon MD, Geim AK (2000) Diamagnetic levitation: flying frogs and floating magnets (invited). J Appl Phys 87:6200–6204CrossRef
Zurück zum Zitat Sumari D, Grimberg BT, Blankenship D, Mugasa J, Mugittu K, Moore L, Gwakisa P, Zborowski M (2016) Application of magnetic cytosmear for the estimation of Plasmodium falciparum gametocyte density and detection of asexual stages in asymptomatic children. Malar J 15(1):113. doi:10.1186/s12936-016-1170-4 CrossRef Sumari D, Grimberg BT, Blankenship D, Mugasa J, Mugittu K, Moore L, Gwakisa P, Zborowski M (2016) Application of magnetic cytosmear for the estimation of Plasmodium falciparum gametocyte density and detection of asexual stages in asymptomatic children. Malar J 15(1):113. doi:10.​1186/​s12936-016-1170-4 CrossRef
Zurück zum Zitat Sun JJ (1980) Methods and apparatus for separating particles using a magnetic barrier. U.S. Patent Sun JJ (1980) Methods and apparatus for separating particles using a magnetic barrier. U.S. Patent
Zurück zum Zitat Sun J, Zborowski M, Chalmers JJ (2011) Quantification of both the presence, and oxidation state, of Mn in Bacillus atrophaeus spores and its imparting of magnetic susceptibility to the spores. Biotechnol Bioeng 108(5):1119–1129CrossRef Sun J, Zborowski M, Chalmers JJ (2011) Quantification of both the presence, and oxidation state, of Mn in Bacillus atrophaeus spores and its imparting of magnetic susceptibility to the spores. Biotechnol Bioeng 108(5):1119–1129CrossRef
Zurück zum Zitat Takayasu M, Kelland DR, Minervini JV (2000) Continuous magnetic separation of blood components from whole blood. IEEE Trans Appl Supercond 10(1):927–930CrossRef Takayasu M, Kelland DR, Minervini JV (2000) Continuous magnetic separation of blood components from whole blood. IEEE Trans Appl Supercond 10(1):927–930CrossRef
Zurück zum Zitat Thanh NTK (2012) Magnetic nanoparticles: from fabrication to clinical applications. CRC Press, Boca RatonCrossRef Thanh NTK (2012) Magnetic nanoparticles: from fabrication to clinical applications. CRC Press, Boca RatonCrossRef
Zurück zum Zitat Ugelstad J, Stenstad P, Kilaas L, Prestvik WS, Herje R, Berge A, Hornes E (1993) Monodisperse magnetic polymer particles. New biochemical and biomedical applications. Blood Purif 11(6):349–369CrossRef Ugelstad J, Stenstad P, Kilaas L, Prestvik WS, Herje R, Berge A, Hornes E (1993) Monodisperse magnetic polymer particles. New biochemical and biomedical applications. Blood Purif 11(6):349–369CrossRef
Zurück zum Zitat Vojtisek M, Tarn M, Hirota N, Pamme N (2012) Microfluidic devices in superconducting magnets: on-chip free-flow diamagnetophoresis of polymer particles and bubbles. Microfluid Nanofluid 13:625–635. doi:10.1007/s10404-012-0979-6 CrossRef Vojtisek M, Tarn M, Hirota N, Pamme N (2012) Microfluidic devices in superconducting magnets: on-chip free-flow diamagnetophoresis of polymer particles and bubbles. Microfluid Nanofluid 13:625–635. doi:10.​1007/​s10404-012-0979-6 CrossRef
Zurück zum Zitat Vyas KN, Palfreyman JJ, Love DM, Mitrelias T, Barnes CH (2012) Magnetically labelled gold and epoxy bi-functional microcarriers for suspension based bioassay technologies. Lab Chip 12(24):5272–5278. doi:10.1039/c2lc41022b CrossRef Vyas KN, Palfreyman JJ, Love DM, Mitrelias T, Barnes CH (2012) Magnetically labelled gold and epoxy bi-functional microcarriers for suspension based bioassay technologies. Lab Chip 12(24):5272–5278. doi:10.​1039/​c2lc41022b CrossRef
Zurück zum Zitat Watarai H, Namba M (2001) Magnetophoretic behavior of single polystyrene particles in aqueous manganese(II) chloride. Anal Sci 17(10):1233–1236CrossRef Watarai H, Namba M (2001) Magnetophoretic behavior of single polystyrene particles in aqueous manganese(II) chloride. Anal Sci 17(10):1233–1236CrossRef
Zurück zum Zitat Williams PS, Zborowski M, Chalmers JJ (1999) Flow rate optimization for the quadrupole magnetic cell sorter. Anal Chem 71(17):3799–3807CrossRef Williams PS, Zborowski M, Chalmers JJ (1999) Flow rate optimization for the quadrupole magnetic cell sorter. Anal Chem 71(17):3799–3807CrossRef
Zurück zum Zitat Williams PS, Carpino F, Zborowski M (2010) Characterization of magnetic nanoparticles using programmed quadrupole magnetic. Philos Trans Ser A Math Phys Eng Sci 368(1927):4419–4437. doi:10.1098/rsta.2010.0133 CrossRef Williams PS, Carpino F, Zborowski M (2010) Characterization of magnetic nanoparticles using programmed quadrupole magnetic. Philos Trans Ser A Math Phys Eng Sci 368(1927):4419–4437. doi:10.​1098/​rsta.​2010.​0133 CrossRef
Zurück zum Zitat Xue W (2016) Measurements of Cellular Intrinsic Magnetism with Cell Tracking Velocimetry and Separation with Magnetic Deposition Microscopy, Ph.D. Thesis, The Ohio State University Xue W (2016) Measurements of Cellular Intrinsic Magnetism with Cell Tracking Velocimetry and Separation with Magnetic Deposition Microscopy, Ph.D. Thesis, The Ohio State University
Zurück zum Zitat Yavuz CT, Prakash A, Mayo JT, Colvin VL (2009) Magnetic separations: from steel plants to biotechnology. Chem Eng Sci 64:2510–2521CrossRef Yavuz CT, Prakash A, Mayo JT, Colvin VL (2009) Magnetic separations: from steel plants to biotechnology. Chem Eng Sci 64:2510–2521CrossRef
Zurück zum Zitat Zborowski M, Chalmers JJ (2008) Magnetic cell separation, vol 32. Laboratory techniques in biochemistry and molecular biology, vol 32. Elsevier, B.V., Amsterdam Zborowski M, Chalmers JJ (2008) Magnetic cell separation, vol 32. Laboratory techniques in biochemistry and molecular biology, vol 32. Elsevier, B.V., Amsterdam
Zurück zum Zitat Zborowski M, Malchesky PS, Jan TF, Hall GS (1992) Quantitative separation of bacteria in saline solution using lanthanide Er(III) and a magnetic field. J Gen Microbiol 138(1):63–68. doi:10.1099/00221287-138-1-63 CrossRef Zborowski M, Malchesky PS, Jan TF, Hall GS (1992) Quantitative separation of bacteria in saline solution using lanthanide Er(III) and a magnetic field. J Gen Microbiol 138(1):63–68. doi:10.​1099/​00221287-138-1-63 CrossRef
Zurück zum Zitat Zborowski M, Fuh CB, Green R, Sun L, Chalmers JJ (1995) Analytical magnetapheresis of ferritin-labeled lymphocytes. Anal Chem 67(20):3702–3712CrossRef Zborowski M, Fuh CB, Green R, Sun L, Chalmers JJ (1995) Analytical magnetapheresis of ferritin-labeled lymphocytes. Anal Chem 67(20):3702–3712CrossRef
Zurück zum Zitat Zhang H, Moore LR, Zborowski M, Williams PS, Margel S, Chalmers JJ (2005) Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions. Analyst 130(4):514–527. doi:10.1039/b412723d CrossRef Zhang H, Moore LR, Zborowski M, Williams PS, Margel S, Chalmers JJ (2005) Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions. Analyst 130(4):514–527. doi:10.​1039/​b412723d CrossRef
Zurück zum Zitat Zimmels Y, Yaniv I (1976) Characterization of magnetic forces by means of suspended particles in paramagnetic solutions. IEEE Trans Magn 4:359–368CrossRef Zimmels Y, Yaniv I (1976) Characterization of magnetic forces by means of suspended particles in paramagnetic solutions. IEEE Trans Magn 4:359–368CrossRef
Zurück zum Zitat Zimmerman PA, Thomson JM, Fujioka H, Collins WE, Zborowski M (2006) Diagnosis of malaria by magnetic deposition microscopy. Am J Trop Med Hyg 74(4):568–572 Zimmerman PA, Thomson JM, Fujioka H, Collins WE, Zborowski M (2006) Diagnosis of malaria by magnetic deposition microscopy. Am J Trop Med Hyg 74(4):568–572
Metadaten
Titel
Magnetic Cell Manipulation and Sorting
verfasst von
Maciej Zborowski
Jeffrey J. Chalmers
William G. Lowrie
Copyright-Jahr
2017
DOI
https://doi.org/10.1007/978-3-319-44139-9_2

Neuer Inhalt