Abstract

Monitoring depth of anesthesia (DOA) via vital signs is a major ongoing challenge for anesthetists. A number of electroencephalogram (EEG)-based monitors such as the Bispectral (BIS) index have been proposed. However, anesthesia is related to central and autonomic nervous system functions whereas the EEG signal originates only from the central nervous system. This paper proposes an automated DOA detection system which consists of three steps. Initially, we introduce multiscale modified permutation entropy index which is robust in the characterization of the burst suppression pattern and combine multiscale information. This index quantifies the amount of complexity in EEG data and is computationally efficient, conceptually simple and artifact resistant. Then, autonomic nervous system activity is quantified with heart rate and mean arterial pressure which are easily acquired using routine monitoring machine. Finally, the extracted features are used as input to a linear discriminate analyzer (LDA). The method is validated with data obtained from 25 patients during the cardiac surgery requiring cardiopulmonary bypass. The experimental results indicate that an overall accuracy of 89.4 % can be obtained using combination of EEG measure and hemodynamic variables, together with LDA to classify the vital sign into awake, light, surgical and deep anesthetised states. The results demonstrate that the proposed method can estimate DOA more effectively than the commercial BIS index with a stronger artifact-resistance.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
Zurück zum Zitat Ahmadi B, Amirfattahi R (2010) Comparison of Correlation Dimension and Fractal Dimension in Estimating BIS index. Wirel Sens Net 2:67–73 Ahmadi B, Amirfattahi R (2010) Comparison of Correlation Dimension and Fractal Dimension in Estimating BIS index. Wirel Sens Net 2:67–73
Zurück zum Zitat Al-Kadi MI, Ibne Reaz MB, Mohd Ali MA (2013) Evolution of electroencephalogram signal analysis techniques during anesthesia. Sensors 13(5):6605–6635PubMedCentralPubMedCrossRef Al-Kadi MI, Ibne Reaz MB, Mohd Ali MA (2013) Evolution of electroencephalogram signal analysis techniques during anesthesia. Sensors 13(5):6605–6635PubMedCentralPubMedCrossRef
Zurück zum Zitat Baharav A, Kotagal S, Gibbons V, Rubin BK, Pratt G, Karin J, Akselrod S (1995) Fluctuation in autonomic nervous activity during sleep displayed by power spectrum analysis of heart rate variability. Neurology 45(6):1183–1187PubMedCrossRef Baharav A, Kotagal S, Gibbons V, Rubin BK, Pratt G, Karin J, Akselrod S (1995) Fluctuation in autonomic nervous activity during sleep displayed by power spectrum analysis of heart rate variability. Neurology 45(6):1183–1187PubMedCrossRef
Zurück zum Zitat Bandt C, Pompe B (2002) Permutation entropy: a natural complexity measure for time series. Phys Rev Lett 88:174102PubMedCrossRef Bandt C, Pompe B (2002) Permutation entropy: a natural complexity measure for time series. Phys Rev Lett 88:174102PubMedCrossRef
Zurück zum Zitat Bostanov V (2004) BCI competition 2003—data sets ib and iib: feature extraction from event-related brain potentials with the continuous wavelet transform and the t-value scalogram. IEEE Trans Biomed Eng 51:57–61CrossRef Bostanov V (2004) BCI competition 2003—data sets ib and iib: feature extraction from event-related brain potentials with the continuous wavelet transform and the t-value scalogram. IEEE Trans Biomed Eng 51:57–61CrossRef
Zurück zum Zitat Campagna JA, Miller KW, Forman SA (2002) Mechanisms of actions of inhaled anesthetics. J Neural Eng 348:2110–2124 Campagna JA, Miller KW, Forman SA (2002) Mechanisms of actions of inhaled anesthetics. J Neural Eng 348:2110–2124
Zurück zum Zitat Costa M, Goldberger AL, Peng CK (2003) Multiscale entropy analysis of physiologic time series. Phys Rev Lett 89:062102 Costa M, Goldberger AL, Peng CK (2003) Multiscale entropy analysis of physiologic time series. Phys Rev Lett 89:062102
Zurück zum Zitat Fell J, Kaplan A, Darkhovsky B, Röschke J (2000) EEG analysis with nonlinear deterministic and stochastic methods: a combined strategy. Acta Neurobiol Exp 60:87–108 Fell J, Kaplan A, Darkhovsky B, Röschke J (2000) EEG analysis with nonlinear deterministic and stochastic methods: a combined strategy. Acta Neurobiol Exp 60:87–108
Zurück zum Zitat Ferents R, Lipping T, Anier A, Jntti V, Melto S, Hovilehto S (2006) Comparison of entropy and complexity measures for the assessment of depth of sedation. IEEE Trans Biomed Eng 53:1067–1077CrossRef Ferents R, Lipping T, Anier A, Jntti V, Melto S, Hovilehto S (2006) Comparison of entropy and complexity measures for the assessment of depth of sedation. IEEE Trans Biomed Eng 53:1067–1077CrossRef
Zurück zum Zitat Fukunaga K (1990) Statistical pattern recognition, 2nd edn. Academic Press, New York Fukunaga K (1990) Statistical pattern recognition, 2nd edn. Academic Press, New York
Zurück zum Zitat Hagihira S, Takashina M, Mori T, Mashimo T, Yoshiya I (2001) Practical issues in bispectral analysis of electroencephalographic signals. Anesth Analg 93:966–970PubMedCrossRef Hagihira S, Takashina M, Mori T, Mashimo T, Yoshiya I (2001) Practical issues in bispectral analysis of electroencephalographic signals. Anesth Analg 93:966–970PubMedCrossRef
Zurück zum Zitat Hosseini PT, Shalbaf R, Nasrabadi AM (2010) Extracting a seizure intensity index from one-channel EEG signal using bispectral and detrended fluctuation analysis. J Biomed Sci Eng 3:253–261CrossRef Hosseini PT, Shalbaf R, Nasrabadi AM (2010) Extracting a seizure intensity index from one-channel EEG signal using bispectral and detrended fluctuation analysis. J Biomed Sci Eng 3:253–261CrossRef
Zurück zum Zitat Huang HH, Lee YH, Chan HL, Wang YP, Huang CH (2008) Using a short-term parameter of heart rate variability to distinguish awake from isoflurane anesthetic states. Med Biol Eng Comput 46:977–984PubMedCrossRef Huang HH, Lee YH, Chan HL, Wang YP, Huang CH (2008) Using a short-term parameter of heart rate variability to distinguish awake from isoflurane anesthetic states. Med Biol Eng Comput 46:977–984PubMedCrossRef
Zurück zum Zitat Johansen JW, Sebel PS (2000) Development and clinical application of electroencephalographic bispectrum monitoring. Anesthesiology 93:1336–1344PubMedCrossRef Johansen JW, Sebel PS (2000) Development and clinical application of electroencephalographic bispectrum monitoring. Anesthesiology 93:1336–1344PubMedCrossRef
Zurück zum Zitat Kortelainen J, Väyrynen E, Seppänen T (2011a) Isomap approach to EEG-based assessment of neurophysiological changes during anesthesia. IEEE Trans Neural Syst Rehabil Eng 19:113–120PubMedCrossRef Kortelainen J, Väyrynen E, Seppänen T (2011a) Isomap approach to EEG-based assessment of neurophysiological changes during anesthesia. IEEE Trans Neural Syst Rehabil Eng 19:113–120PubMedCrossRef
Zurück zum Zitat Kortelainen J, Väyrynen E, Seppänen T (2011b) Depth of anesthesia during multidrug infusion: separating the effects of propofol and remifentanil using the spectral features of EEG. IEEE Trans Biomed Eng 58:1216–1223PubMedCrossRef Kortelainen J, Väyrynen E, Seppänen T (2011b) Depth of anesthesia during multidrug infusion: separating the effects of propofol and remifentanil using the spectral features of EEG. IEEE Trans Biomed Eng 58:1216–1223PubMedCrossRef
Zurück zum Zitat Lehmann A, Boldt J, Thaler E, Piper S, Weisse U (2002) Bispectral index in patients with target-controlled or manually-controlled infusion of propofol. Anesth Analg 95:639–644PubMed Lehmann A, Boldt J, Thaler E, Piper S, Weisse U (2002) Bispectral index in patients with target-controlled or manually-controlled infusion of propofol. Anesth Analg 95:639–644PubMed
Zurück zum Zitat Li XL, Cui SY, Voss LJ (2008) Using permutation entropy to measure the electroencephalographic effects of sevoflurane. Anesthsiology 109:448–456CrossRef Li XL, Cui SY, Voss LJ (2008) Using permutation entropy to measure the electroencephalographic effects of sevoflurane. Anesthsiology 109:448–456CrossRef
Zurück zum Zitat Liley DT, Sinclair NC, Lipping T, Heyse B, Vereecke HE, Struys MM (2010) Propofol and remifentanil differentially modulate frontal electroencephalographic activity. Anesthsiology 113:292–304CrossRef Liley DT, Sinclair NC, Lipping T, Heyse B, Vereecke HE, Struys MM (2010) Propofol and remifentanil differentially modulate frontal electroencephalographic activity. Anesthsiology 113:292–304CrossRef
Zurück zum Zitat Luginbühl M, Wüthrich S, Petersen-Felix S, Zbinden A, Schnider T (2003) Different benefit of bispectral index (BIS) in desflurane and propofol anesthesia. Acta Anaesthesiol Scand 47:165–173PubMedCrossRef Luginbühl M, Wüthrich S, Petersen-Felix S, Zbinden A, Schnider T (2003) Different benefit of bispectral index (BIS) in desflurane and propofol anesthesia. Acta Anaesthesiol Scand 47:165–173PubMedCrossRef
Zurück zum Zitat Mahfouf M, Asbury AJ, Linkens DA (2003) Unconstrained and constrained generalized predictive control of depth of anesthesia during surgery. Control Eng Pract 11:1501–1515CrossRef Mahfouf M, Asbury AJ, Linkens DA (2003) Unconstrained and constrained generalized predictive control of depth of anesthesia during surgery. Control Eng Pract 11:1501–1515CrossRef
Zurück zum Zitat Muncaster A, Sleigh J, Williams M (2003) Changes in consciousness, conceptual memory, and quantitative electroencephalographical measures during recovery from sevoflurane- and remifentanil-based anesthesia. Anesth Analg 96:720–725PubMedCrossRef Muncaster A, Sleigh J, Williams M (2003) Changes in consciousness, conceptual memory, and quantitative electroencephalographical measures during recovery from sevoflurane- and remifentanil-based anesthesia. Anesth Analg 96:720–725PubMedCrossRef
Zurück zum Zitat Myles P, Leslie K, McNeil J, Forbes A, Chan M (2004) Bispectral index monitoring to prevent awareness during anaesthesia: the B-AWARE randomized controlled trial. Lancet 363:1757–1763PubMedCrossRef Myles P, Leslie K, McNeil J, Forbes A, Chan M (2004) Bispectral index monitoring to prevent awareness during anaesthesia: the B-AWARE randomized controlled trial. Lancet 363:1757–1763PubMedCrossRef
Zurück zum Zitat Nakatsuka I, Ochiai R, Takeda J (2002) Changes in heart rate variability in sevoflurane and nitrous oxide anesthesia: effects of respiration and depth of anesthesia. J Clin Anesth 14:196–200PubMedCrossRef Nakatsuka I, Ochiai R, Takeda J (2002) Changes in heart rate variability in sevoflurane and nitrous oxide anesthesia: effects of respiration and depth of anesthesia. J Clin Anesth 14:196–200PubMedCrossRef
Zurück zum Zitat Nguyen-Ky T, Wen P, Li Y (2013) Consciousness and depth of anesthesia assessment based on bayesian analysis of EEG signals. IEEE Trans Biomed, Eng Nguyen-Ky T, Wen P, Li Y (2013) Consciousness and depth of anesthesia assessment based on bayesian analysis of EEG signals. IEEE Trans Biomed, Eng
Zurück zum Zitat Olofsen E, Sleigh JW, Dahan A (2008) Permutation entropy of the electroencephalogram: a measure of anesthetic drug effect. Br J Anaesth 101:810–821PubMedCrossRef Olofsen E, Sleigh JW, Dahan A (2008) Permutation entropy of the electroencephalogram: a measure of anesthetic drug effect. Br J Anaesth 101:810–821PubMedCrossRef
Zurück zum Zitat Ouyang GX, Dang C, Li XL (2009) Multiscale entropy analysis of EEG recordings in epileptic rats. Biomed Eng Appl Basis Commun 21:169–176CrossRef Ouyang GX, Dang C, Li XL (2009) Multiscale entropy analysis of EEG recordings in epileptic rats. Biomed Eng Appl Basis Commun 21:169–176CrossRef
Zurück zum Zitat Pilge S, Zanner R, Schneider G, Blum J, Kreuzer M, Kochs EF (2006) Time delay of index calculation: analysis of cerebral state, bispectral, and narcotrend indices. Anesthesiology 104:488–494PubMedCrossRef Pilge S, Zanner R, Schneider G, Blum J, Kreuzer M, Kochs EF (2006) Time delay of index calculation: analysis of cerebral state, bispectral, and narcotrend indices. Anesthesiology 104:488–494PubMedCrossRef
Zurück zum Zitat Rampil IJ (1998) A primer for EEG signal processing in anesthesia. Anesthesiology 89:980–1002PubMedCrossRef Rampil IJ (1998) A primer for EEG signal processing in anesthesia. Anesthesiology 89:980–1002PubMedCrossRef
Zurück zum Zitat Sarkela M, Mustola S, Seppanen T, Koskinen M, Lepola P, Suominen K (2002) Automatic analysis and monitoring of burst suppression in anesthesia. J Clin Monit Comput 17:125–134PubMedCrossRef Sarkela M, Mustola S, Seppanen T, Koskinen M, Lepola P, Suominen K (2002) Automatic analysis and monitoring of burst suppression in anesthesia. J Clin Monit Comput 17:125–134PubMedCrossRef
Zurück zum Zitat Sebel PS, Bowdle TA, Ghoneim MM, Rampil IJ, Padilla RE, Gan TJ, Domino KB (2004) The incidence of awareness during anesthesia: a multicenter United States study. Anesth Analg 99:833–839PubMedCrossRef Sebel PS, Bowdle TA, Ghoneim MM, Rampil IJ, Padilla RE, Gan TJ, Domino KB (2004) The incidence of awareness during anesthesia: a multicenter United States study. Anesth Analg 99:833–839PubMedCrossRef
Zurück zum Zitat Shafqat K, Pal SK, Kumari S, Kyriacou PA (2011) Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block). Physiol Meas 32:483–497PubMedCrossRef Shafqat K, Pal SK, Kumari S, Kyriacou PA (2011) Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block). Physiol Meas 32:483–497PubMedCrossRef
Zurück zum Zitat Shalbaf R, Behnam H, Sleigh JW, Voss LJ (2012a) Using the Hilbert-Huang transform to measure the electroencephalographic effect of propofol. Physiol Meas 33:271–285PubMedCrossRef Shalbaf R, Behnam H, Sleigh JW, Voss LJ (2012a) Using the Hilbert-Huang transform to measure the electroencephalographic effect of propofol. Physiol Meas 33:271–285PubMedCrossRef
Zurück zum Zitat Shalbaf R, Behnam H, Sleigh J, Voss L (2012b) Measuring the effects of sevoflurane on electroencephalogram using sample entropy. Acta Anaesthesiol Scand 56:880–889PubMedCrossRef Shalbaf R, Behnam H, Sleigh J, Voss L (2012b) Measuring the effects of sevoflurane on electroencephalogram using sample entropy. Acta Anaesthesiol Scand 56:880–889PubMedCrossRef
Zurück zum Zitat Shalbaf A, Behnam H, Alizade-Sani Z, Shojaifard M (2013a) Automatic assessment of regional and global wall motion abnormalities in echocardiography images by nonlinear dimensionality reduction. Med Phys 40:052904PubMedCrossRef Shalbaf A, Behnam H, Alizade-Sani Z, Shojaifard M (2013a) Automatic assessment of regional and global wall motion abnormalities in echocardiography images by nonlinear dimensionality reduction. Med Phys 40:052904PubMedCrossRef
Zurück zum Zitat Shalbaf R, Behnam H, Sleigh J, Voss LA, Steyn-Ross A (2013b) Monitoring the depth of anesthesia using entropy features and an artificial neural network. J Neurosci Methods 218:17–24PubMedCrossRef Shalbaf R, Behnam H, Sleigh J, Voss LA, Steyn-Ross A (2013b) Monitoring the depth of anesthesia using entropy features and an artificial neural network. J Neurosci Methods 218:17–24PubMedCrossRef
Zurück zum Zitat Shalbaf R, Behnam H, Moghadam JH (2013c) The brain function index as a depth of anesthesia indicator using complexity measures, In Proceedings of IEEE International Conference on Systems, Process and Control. ICSPC, Kuala Lumpur Shalbaf R, Behnam H, Moghadam JH (2013c) The brain function index as a depth of anesthesia indicator using complexity measures, In Proceedings of IEEE International Conference on Systems, Process and Control. ICSPC, Kuala Lumpur
Zurück zum Zitat Shieh JS, Linkens DA, Asbury AJ (2005) A hierarchical system of on-line advisory for monitoring and controlling the depth of anaesthesia using self-organizing fuzzy logic. Eng Appl Artif Intell 18:307–316CrossRef Shieh JS, Linkens DA, Asbury AJ (2005) A hierarchical system of on-line advisory for monitoring and controlling the depth of anaesthesia using self-organizing fuzzy logic. Eng Appl Artif Intell 18:307–316CrossRef
Zurück zum Zitat Sleigh JW, Donovan J (1999) Comparison of the bispectral index, 95 % spectral edge frequency and approximate entropy of the EEG, with changes in heart rate variability during induction and recovery from general anaesthesia. Br J Anesth 82:666–671CrossRef Sleigh JW, Donovan J (1999) Comparison of the bispectral index, 95 % spectral edge frequency and approximate entropy of the EEG, with changes in heart rate variability during induction and recovery from general anaesthesia. Br J Anesth 82:666–671CrossRef
Zurück zum Zitat Sleigh JW, Steyn-Ross DA, Steyn-Ross ML, Grant C, Ludbrook G (2004) Cortical entropy changes with general anaesthesia: theory and experiment. Physiol Meas 25:921–934PubMedCrossRef Sleigh JW, Steyn-Ross DA, Steyn-Ross ML, Grant C, Ludbrook G (2004) Cortical entropy changes with general anaesthesia: theory and experiment. Physiol Meas 25:921–934PubMedCrossRef
Zurück zum Zitat Talebi N, Nasrabadi AM, Curran T (2012) Investigation of changes in EEG complexity during memory retrieval: the effect of midazolam. Cogn Neurodyn 6:537–546PubMedCentralPubMedCrossRef Talebi N, Nasrabadi AM, Curran T (2012) Investigation of changes in EEG complexity during memory retrieval: the effect of midazolam. Cogn Neurodyn 6:537–546PubMedCentralPubMedCrossRef
Zurück zum Zitat Viertio-Oja H, Maja V, Sarkela M, Talja P (2004) Description of the entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy module. Acta Anesthesiol Scand 48:154–164CrossRef Viertio-Oja H, Maja V, Sarkela M, Talja P (2004) Description of the entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy module. Acta Anesthesiol Scand 48:154–164CrossRef
Metadaten
Titel
Monitoring depth of anesthesia using combination of EEG measure and hemodynamic variables
verfasst von
R. Shalbaf
H. Behnam
H. Jelveh Moghadam
Publikationsdatum
01.02.2015
Verlag
Springer Netherlands
Erschienen in
Cognitive Neurodynamics / Ausgabe 1/2015
Print ISSN: 1871-4080
Elektronische ISSN: 1871-4099
DOI
https://doi.org/10.1007/s11571-014-9295-z

Weitere Artikel der Ausgabe 1/2015

Cognitive Neurodynamics 1/2015 Zur Ausgabe

Neuer Inhalt