Abstract

This article is devoted to analyzing the noise immunity of pulse waveform contour analysis. Different approaches to the implementation of the pulse waveform contour analysis were considered. It was demonstrated that a classical approach for the morphological analysis of the pulse wave based on using the stiffness index and the reflection index do not provide sufficient diagnostic accuracy due to the instability of detection of the reflected wave peak. The technique of contour analysis based on spectral transformation of replicated fragments of the pulse wave is proposed. As a diagnostic index the ratio of the amplitudes of the first two harmonics of the spectrum was used. The influence of measurement uncertainty of the pulse wave amplitude on determining the accuracy of the morphological analysis of the pulse wave realized by different methods was researched.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat “Expert Consensus Document on arterial stiffness: methodological issues and clinical applications,” Eur. Heart J., 27, No. 21, 2588–2605 (2006). “Expert Consensus Document on arterial stiffness: methodological issues and clinical applications,” Eur. Heart J., 27, No. 21, 2588–2605 (2006).
2.
Zurück zum Zitat S. C. Millasseau, J. M. Ritter, K. Takazawa, and P. J. Chowienczyk, “Contour analysis of the photoplethysmographic pulse measured at the finger,” Hypertension, 8, No. 8, 1449–1456 (2006).CrossRef S. C. Millasseau, J. M. Ritter, K. Takazawa, and P. J. Chowienczyk, “Contour analysis of the photoplethysmographic pulse measured at the finger,” Hypertension, 8, No. 8, 1449–1456 (2006).CrossRef
3.
Zurück zum Zitat A. A. Fedotov and S. A. Akulov, Measurement Converters of Biomedical Signals of Clinical Monitoring Systems, Radio i Svyaz, Moscow (2013). A. A. Fedotov and S. A. Akulov, Measurement Converters of Biomedical Signals of Clinical Monitoring Systems, Radio i Svyaz, Moscow (2013).
4.
Zurück zum Zitat T. Weber, J. Auer, M. F. O’Rourke, et al., “Arterial stiffness, wave reflections, and the risk of coronary artery disease,” Circulation, 109, No. 4, 184–189 (2004).CrossRef T. Weber, J. Auer, M. F. O’Rourke, et al., “Arterial stiffness, wave reflections, and the risk of coronary artery disease,” Circulation, 109, No. 4, 184–189 (2004).CrossRef
5.
Zurück zum Zitat S. C. Millasseau, R. P. Kelly, J. M. Ritter, and P. J. Chowienczyk, “Determination of age-related increases in large artery stiffness by digital pulse contour analysis,” Clin. Sci., 103, No. 4, 371–377 (2002).CrossRef S. C. Millasseau, R. P. Kelly, J. M. Ritter, and P. J. Chowienczyk, “Determination of age-related increases in large artery stiffness by digital pulse contour analysis,” Clin. Sci., 103, No. 4, 371–377 (2002).CrossRef
6.
Zurück zum Zitat L. I. Kalakutsky and A. A. Fedotov, “Diagnosis of dysfunction of the vascular endothelium by the method of contour analysis of the pulse wave,” Izv. Yuzhn. Fed. Univ. Tekhn. Nauki, No. 9, 93–98 (2009). L. I. Kalakutsky and A. A. Fedotov, “Diagnosis of dysfunction of the vascular endothelium by the method of contour analysis of the pulse wave,” Izv. Yuzhn. Fed. Univ. Tekhn. Nauki, No. 9, 93–98 (2009).
7.
Zurück zum Zitat R. M. Rangayan, Analysis of Biomedical Signals. Practical Approach, FIZMATLIT, Moscow (2007). R. M. Rangayan, Analysis of Biomedical Signals. Practical Approach, FIZMATLIT, Moscow (2007).
8.
Zurück zum Zitat A. A. Fedotov, “Amplitude-time method for detecting characteristic pulse wave points,” Med. Tekhn., No. 6, 22–28 (2012). A. A. Fedotov, “Amplitude-time method for detecting characteristic pulse wave points,” Med. Tekhn., No. 6, 22–28 (2012).
9.
Zurück zum Zitat A. A. Fedotov, A. S. Akulova, S. A. Akulov, and M. A. Reshetnikova, “Novel spectral approach for pulse waves contour analysis,” IFMBE Proc., 61, 16–20 (2017).CrossRef A. A. Fedotov, A. S. Akulova, S. A. Akulov, and M. A. Reshetnikova, “Novel spectral approach for pulse waves contour analysis,” IFMBE Proc., 61, 16–20 (2017).CrossRef
10.
Zurück zum Zitat P. V. Novitsky and I. A. Zograf, Assessing the Errors of Measurement Results, Energoatomizdat, Moscow (1991). P. V. Novitsky and I. A. Zograf, Assessing the Errors of Measurement Results, Energoatomizdat, Moscow (1991).
Metadaten
Titel
Noise Immunity of Pulse Wave Contour Analysis
verfasst von
A. A. Fedotov
Publikationsdatum
11.07.2019
Verlag
Springer US
Erschienen in
Measurement Techniques / Ausgabe 3/2019
Print ISSN: 0543-1972
Elektronische ISSN: 1573-8906
DOI
https://doi.org/10.1007/s11018-019-01618-w

Weitere Artikel der Ausgabe 3/2019

Measurement Techniques 3/2019 Zur Ausgabe