Skip to main content

2019 | OriginalPaper | Buchkapitel

Parameter Estimation of Decaying DC Component via Improved Levenberg-Marquardt Algorithm

verfasst von : Xiuchun Xiao, Baitao Chen, Jingwen Yan

Erschienen in: Transactions on Edutainment XV

Verlag: Springer Berlin Heidelberg

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Fault current usually contain a decaying DC component and some kinds of noise. This DC component and noise decrease the accuracy and speed of the operation of digital relay protection. In order to remove the decaying DC component and noise in current signals for power system, parameters of decaying DC component should be estimated firstly. To solve this parameter estimation problem, a specific neural network is proposed, and then an adaptive learning algorithm based on improved Levenberg-Marquardt algorithm is derived to iteratively resolve its weights by optimizing the pre-defined objective function. From weights of the trained neural network, all parameters of decaying DC components can be well calculated. Profiting from good nature in fault tolerance of neural network, the proposed algorithm possess a good performance in resistance to noise. Simulation experimental results indicate that our algorithm can achieve a high accuracy with acceptable time consumption for parameters estimating in noise.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Qian, H., Zhao, R., Chen, T.: Inter-harmonics analysis based on interpolating windowed FFT algorithm. IEEE Trans. Power Delivery 22(2), 1064–1069 (2007)CrossRef Qian, H., Zhao, R., Chen, T.: Inter-harmonics analysis based on interpolating windowed FFT algorithm. IEEE Trans. Power Delivery 22(2), 1064–1069 (2007)CrossRef
2.
Zurück zum Zitat Lim, Y., Kim, H.M., Kang, S.: A reliable data delivery mechanism for grid power quality using neural networks in wireless sensor networks. Sensors 10, 9349–9358 (2010)CrossRef Lim, Y., Kim, H.M., Kang, S.: A reliable data delivery mechanism for grid power quality using neural networks in wireless sensor networks. Sensors 10, 9349–9358 (2010)CrossRef
3.
Zurück zum Zitat Cheng, P., Liu, W.: Design of storage system of running platform for electric SCADA System. J. Comput. Res. Dev. 48(suppl.), 132–136 (2011) Cheng, P., Liu, W.: Design of storage system of running platform for electric SCADA System. J. Comput. Res. Dev. 48(suppl.), 132–136 (2011)
4.
Zurück zum Zitat Liu, Y., Wang, X., Liu, Y., et al.: Resolution-enhanced harmonic and inter-harmonic measurement for power quality analysis in cyber-physical energy system. Sensors 16(7), 946 (2016)CrossRef Liu, Y., Wang, X., Liu, Y., et al.: Resolution-enhanced harmonic and inter-harmonic measurement for power quality analysis in cyber-physical energy system. Sensors 16(7), 946 (2016)CrossRef
5.
Zurück zum Zitat Cho, Y., Lee, C., Jang, G., Lee, H.: An innovative decaying DC component estimation algorithm for digital relaying. IEEE Trans. Power Delivery 24(1), 73–78 (2009)CrossRef Cho, Y., Lee, C., Jang, G., Lee, H.: An innovative decaying DC component estimation algorithm for digital relaying. IEEE Trans. Power Delivery 24(1), 73–78 (2009)CrossRef
6.
Zurück zum Zitat Lim, Y., Kim, H.M., Kang, S.: A design of wireless sensor networks for a power quality monitoring system. Sensors 10, 9712–9725 (2010)CrossRef Lim, Y., Kim, H.M., Kang, S.: A design of wireless sensor networks for a power quality monitoring system. Sensors 10, 9712–9725 (2010)CrossRef
7.
Zurück zum Zitat Jin, G., Li, L., Gao, L., et al.: Real-time fundamental current extraction under inter-harmonics in power system based on high resolution harmonics tracking and fast sequential least square. Int. J. Electr. Power Energy Syst. 61, 137–144 (2014)CrossRef Jin, G., Li, L., Gao, L., et al.: Real-time fundamental current extraction under inter-harmonics in power system based on high resolution harmonics tracking and fast sequential least square. Int. J. Electr. Power Energy Syst. 61, 137–144 (2014)CrossRef
8.
Zurück zum Zitat Wen, H., Zhang, J., Meng, Z., et al.: Harmonic estimation using symmetrical interpolation FFT based on triangular self-convolution window. IEEE Trans. Industr. Inf. 11(1), 16–26 (2015)CrossRef Wen, H., Zhang, J., Meng, Z., et al.: Harmonic estimation using symmetrical interpolation FFT based on triangular self-convolution window. IEEE Trans. Industr. Inf. 11(1), 16–26 (2015)CrossRef
9.
Zurück zum Zitat Yu, S.L., Gu, J.C.: Removal of decaying DC in current and voltage signals using a modified fourier filter algorithm. IEEE Trans. Power Delivery 16(3), 372–379 (2001)CrossRef Yu, S.L., Gu, J.C.: Removal of decaying DC in current and voltage signals using a modified fourier filter algorithm. IEEE Trans. Power Delivery 16(3), 372–379 (2001)CrossRef
10.
Zurück zum Zitat Guo, Y., Kezunovic, M., Chen, D.: Simplified algorithms for removal of the effect of exponentially decaying DC-offset on the fourier algorithm. IEEE Trans. Power Delivery 18(3), 711–717 (2003)CrossRef Guo, Y., Kezunovic, M., Chen, D.: Simplified algorithms for removal of the effect of exponentially decaying DC-offset on the fourier algorithm. IEEE Trans. Power Delivery 18(3), 711–717 (2003)CrossRef
11.
Zurück zum Zitat Kang, S.H., Lee, D.G., Nam, S.R., et al.: Fourier transform-based modified phasor estimation method immune to the effect of the DC offsets. IEEE Trans. Power Delivery 24(3), 1104–1111 (2009)CrossRef Kang, S.H., Lee, D.G., Nam, S.R., et al.: Fourier transform-based modified phasor estimation method immune to the effect of the DC offsets. IEEE Trans. Power Delivery 24(3), 1104–1111 (2009)CrossRef
12.
Zurück zum Zitat Hooshyar, A., Sanaye-Pasand, M.: Accurate measurement of fault currents contaminated with decaying DC offset and CT saturation. IEEE Trans. Power Delivery 27(2), 773–783 (2012)CrossRef Hooshyar, A., Sanaye-Pasand, M.: Accurate measurement of fault currents contaminated with decaying DC offset and CT saturation. IEEE Trans. Power Delivery 27(2), 773–783 (2012)CrossRef
13.
Zurück zum Zitat Benmouyal, G.: Removal of DC-offset in current waveforms using digital mimic filtering. IEEE Trans. Power Delivery 10(2), 621–630 (1995)CrossRef Benmouyal, G.: Removal of DC-offset in current waveforms using digital mimic filtering. IEEE Trans. Power Delivery 10(2), 621–630 (1995)CrossRef
14.
Zurück zum Zitat Granados-Lieberman, D., Romero-Troncoso, R.J., Cabal-Yepez, E., Osornio-Rios, R.A., Franco-Gasca, L.A.: A real-time smart sensor for high-resolution frequency estimation in power systems. Sensors 9, 7412–7429 (2009)CrossRef Granados-Lieberman, D., Romero-Troncoso, R.J., Cabal-Yepez, E., Osornio-Rios, R.A., Franco-Gasca, L.A.: A real-time smart sensor for high-resolution frequency estimation in power systems. Sensors 9, 7412–7429 (2009)CrossRef
15.
Zurück zum Zitat Granados-Lieberman, D., Valtierra-Rodriguez, M., Morales-Hernandez, L., Romero-Troncoso, R., Osornio-Rios, R.: A hilbert transform-based smart sensor for detection, classification, and quantification of power quality disturbances. Sensors 13, 5507–5527 (2013)CrossRef Granados-Lieberman, D., Valtierra-Rodriguez, M., Morales-Hernandez, L., Romero-Troncoso, R., Osornio-Rios, R.: A hilbert transform-based smart sensor for detection, classification, and quantification of power quality disturbances. Sensors 13, 5507–5527 (2013)CrossRef
16.
Zurück zum Zitat Sidhu, T., Zhang, X., Albasri, F., Sachdev, M.: Discrete-fourier-transform-based technique for removal of decaying DC offset from phasor estimates. IEE Proc. Gener. Transm. Distrib. 150(6), 745–752 (2003)CrossRef Sidhu, T., Zhang, X., Albasri, F., Sachdev, M.: Discrete-fourier-transform-based technique for removal of decaying DC offset from phasor estimates. IEE Proc. Gener. Transm. Distrib. 150(6), 745–752 (2003)CrossRef
17.
Zurück zum Zitat Rosolowski, E., Izykowski, J., Kasztenny, B.: Adaptive measuring algorithm suppressing a decaying DC component for digital protective relays. Electr. Power Syst. Res. 60(2), 99–105 (2001)CrossRef Rosolowski, E., Izykowski, J., Kasztenny, B.: Adaptive measuring algorithm suppressing a decaying DC component for digital protective relays. Electr. Power Syst. Res. 60(2), 99–105 (2001)CrossRef
18.
Zurück zum Zitat Xiao, X., Jiang, X., Xie, S., Lu, X., Zhang, Y.: A neural network model for power system inter-harmonics estimation. In: The 7th International Conference on Bio-Inspired Computing: Theories and Applications, vol. 9, pp. 756–760 (2010) Xiao, X., Jiang, X., Xie, S., Lu, X., Zhang, Y.: A neural network model for power system inter-harmonics estimation. In: The 7th International Conference on Bio-Inspired Computing: Theories and Applications, vol. 9, pp. 756–760 (2010)
19.
Zurück zum Zitat Marei, M.I., El-Saadany, E.F., Salama, M.M.A.: A processing unit for symmetrical components and harmonics estimation based on a new adaptive linear combiner structure. IEEE Trans. Power Delivery 19(3), 1245–1252 (2004)CrossRef Marei, M.I., El-Saadany, E.F., Salama, M.M.A.: A processing unit for symmetrical components and harmonics estimation based on a new adaptive linear combiner structure. IEEE Trans. Power Delivery 19(3), 1245–1252 (2004)CrossRef
20.
Zurück zum Zitat Yang, L., Chen, Y.: A new globally convergent Levenberg-Marquardt method for solving nonlinear system of equations. Math. Numerica Sinica 30(4), 388–396 (2008)MathSciNetMATH Yang, L., Chen, Y.: A new globally convergent Levenberg-Marquardt method for solving nonlinear system of equations. Math. Numerica Sinica 30(4), 388–396 (2008)MathSciNetMATH
22.
Zurück zum Zitat Xiao, X., Lai, J., Wang, C.: Parameter estimation of the exponentially damped sinusoids signal using a specific neural network. Neurocomputing 143, 331–338 (2014)CrossRef Xiao, X., Lai, J., Wang, C.: Parameter estimation of the exponentially damped sinusoids signal using a specific neural network. Neurocomputing 143, 331–338 (2014)CrossRef
23.
Zurück zum Zitat Xiao, X., Chen, B., Yan, J.: A specific neural network for estimating decaying DC component. J. Yangzhou Univ. 21(3), 50–54 (2018). (Natural Science Edition) Xiao, X., Chen, B., Yan, J.: A specific neural network for estimating decaying DC component. J. Yangzhou Univ. 21(3), 50–54 (2018). (Natural Science Edition)
Metadaten
Titel
Parameter Estimation of Decaying DC Component via Improved Levenberg-Marquardt Algorithm
verfasst von
Xiuchun Xiao
Baitao Chen
Jingwen Yan
Copyright-Jahr
2019
Verlag
Springer Berlin Heidelberg
DOI
https://doi.org/10.1007/978-3-662-59351-6_5