Physiological closed-loop control systems (PCLCS) provide reliable and efficient treatment in medical care, but it is crucial to ensure patient safety when examining the potential advantages. Traditional animal and clinical studies are resource-intensive and costly, making them impractical for evaluating PCLCS in every relevant clinical scenario. Therefore, computational or mathematical models have emerged as an alternative for assessing PCLCS. Hardware-in-the-loop testing platforms can provide a more efficient alternative to traditional animal and clinical studies. The platforms utilize computational or mathematical models to simulate PCLCS, providing a cost-effective and efficient approach that can minimize errors during the development process. Although various software simulation platforms can model specific physiological systems, there is a lack of hardware emulation platforms for PCLCS. In this demonstration, we present a novel physiological emulation platform (PEP) using a hardware-in-the-loop method developed to connect a computational model of the patient’s physiology to the actual PCLC device hardware, enabling real-time testing of the device while incorporating the hardware components.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Blauw, H., Keith-Hynes, P., Koops, R., DeVries, J.H.: A review of safety and design requirements of the artificial pancreas. Ann. Biomed. Eng. 44(11), 3158–3172 (2016)CrossRef Blauw, H., Keith-Hynes, P., Koops, R., DeVries, J.H.: A review of safety and design requirements of the artificial pancreas. Ann. Biomed. Eng. 44(11), 3158–3172 (2016)CrossRef
3.
Zurück zum Zitat Hovorka, R.: Closed-loop insulin delivery: from bench to clinical practice. Nat. Rev. Endocrinol. 7(7), 385–395 (2011)CrossRef Hovorka, R.: Closed-loop insulin delivery: from bench to clinical practice. Nat. Rev. Endocrinol. 7(7), 385–395 (2011)CrossRef
4.
Zurück zum Zitat Jiang, Z., Connolly, A., Mangharam, R.: Using the virtual heart model to validate the mode-switch pacemaker operation. In: Annual International Conference of the IEEE Engineering in Medicine and Biology. IEEE, pp. 6690–6693 (2010) Jiang, Z., Connolly, A., Mangharam, R.: Using the virtual heart model to validate the mode-switch pacemaker operation. In: Annual International Conference of the IEEE Engineering in Medicine and Biology. IEEE, pp. 6690–6693 (2010)
5.
Zurück zum Zitat Mahmud, S., Zareen, F., Olney, B., Karam, R., et al.: Trojan resilience in implantable and wearable medical devices with virtual biosensing. In: 2022 IEEE 40th International Conference on Computer Design (ICCD), IEEE, pp. 577–584 (2022) Mahmud, S., Zareen, F., Olney, B., Karam, R., et al.: Trojan resilience in implantable and wearable medical devices with virtual biosensing. In: 2022 IEEE 40th International Conference on Computer Design (ICCD), IEEE, pp. 577–584 (2022)
6.
Zurück zum Zitat Man, C.D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., Cobelli, C.: The uva/padova type 1 diabetes simulator: new features. J. Diabetes Sci. Technol. 8(1), 26–34 (2014)CrossRef Man, C.D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., Cobelli, C.: The uva/padova type 1 diabetes simulator: new features. J. Diabetes Sci. Technol. 8(1), 26–34 (2014)CrossRef
7.
Zurück zum Zitat Mendoza, E., Whitney, J.P.: A testbed for haptic and magnetic resonance imaging-guided percutaneous needle biopsy. IEEE Robot. Autom. Lett. 4(4), 3177–3183 (2019)CrossRef Mendoza, E., Whitney, J.P.: A testbed for haptic and magnetic resonance imaging-guided percutaneous needle biopsy. IEEE Robot. Autom. Lett. 4(4), 3177–3183 (2019)CrossRef
8.
Zurück zum Zitat Schmitzer, J., Strobel, C., Blechschmidt, R., Tappe, A., Peuscher, H.: Efficient closed loop simulation of do-it-yourself artificial pancreas systems. J. Diabetes Sci. Technol. 16(1), 61–69 (2022)CrossRef Schmitzer, J., Strobel, C., Blechschmidt, R., Tappe, A., Peuscher, H.: Efficient closed loop simulation of do-it-yourself artificial pancreas systems. J. Diabetes Sci. Technol. 16(1), 61–69 (2022)CrossRef
9.
Zurück zum Zitat Vrooijink, G.J., Irzan, H., Misra, S.: A beating heart testbed for the evaluation of robotic cardiovascular interventions. In: 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), IEEE, pp. 1076–1082 (2018) Vrooijink, G.J., Irzan, H., Misra, S.: A beating heart testbed for the evaluation of robotic cardiovascular interventions. In: 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob), IEEE, pp. 1076–1082 (2018)
10.
Zurück zum Zitat Zhou, X., Kouzel, M., Ren, H., Alemzadeh, H.: Design and validation of an open-source closed-loop testbed for artificial pancreas systems. In: 2022 IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE), IEEE, pp. 1–12 (2022) Zhou, X., Kouzel, M., Ren, H., Alemzadeh, H.: Design and validation of an open-source closed-loop testbed for artificial pancreas systems. In: 2022 IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies (CHASE), IEEE, pp. 1–12 (2022)
Metadaten
Titel
PEP: Hardware Emulation Platform for Physiological Closed-Loop Control Systems
verfasst von
Shakil Mahmud
Samir Ahmed
Robert Karam
Copyright-Jahr
2024
DOI
https://doi.org/10.1007/978-3-031-45882-8_30