Skip to main content
Erschienen in: Shape Memory and Superelasticity 1/2015

01.03.2015

Plasma Arc Melting (PAM) and Corrosion Resistance of Pure NiTi Shape Memory Alloys

verfasst von: A. Tuissi, G. Rondelli, P. Bassani

Erschienen in: Shape Memory and Superelasticity | Ausgabe 1/2015

Einloggen

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Plasma arc melting (PAM) as a suitable non-contaminating melting route for manufacturing high-quality NiTi alloy was successfully examined. The corrosion resistance of PAM Nitinol was evaluated by both potentiodynamic and potentiostatic tests and compared with lower purity NiTi produced by vacuum induction melting (VIM). For the electro-polished surfaces, excellent corrosion resistance of NiTi comparable with the Ti alloys was found with no pitting up to 800 mV versus saturated calomel electrode in simulated body fluid at 37 °C. Potentiostatic results of PAM Nitinol indicate slightly better corrosion resistance than the lower quality VIM alloy.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Shabalovskaya S, Anderegg J, Van Humbeeck J (2008) Recent observations of particulates in Nitinol. Mater Sci Eng A 481–482:431–436CrossRef Shabalovskaya S, Anderegg J, Van Humbeeck J (2008) Recent observations of particulates in Nitinol. Mater Sci Eng A 481–482:431–436CrossRef
2.
Zurück zum Zitat Kimura H, Sohmura T (1987) Surface coating on TiNi shape memory implant alloys. J Osaka Univ Dental Scholl 27:211–223 Kimura H, Sohmura T (1987) Surface coating on TiNi shape memory implant alloys. J Osaka Univ Dental Scholl 27:211–223
4.
Zurück zum Zitat Liang C, Huang N (2009) Electrochemical characteristic of TiNi shape memory alloy in artificial body fluids. J Biomed Mater Res A 89(1):266–269CrossRef Liang C, Huang N (2009) Electrochemical characteristic of TiNi shape memory alloy in artificial body fluids. J Biomed Mater Res A 89(1):266–269CrossRef
5.
Zurück zum Zitat Coda A, Zilio S, Norwich D, Sczerzenie F (2012) Characterization of inclusions in VIM/VAR NiTi alloys. JMEPEG 21:2572–2577CrossRef Coda A, Zilio S, Norwich D, Sczerzenie F (2012) Characterization of inclusions in VIM/VAR NiTi alloys. JMEPEG 21:2572–2577CrossRef
7.
Zurück zum Zitat Morgan N, Wick A, DiCello J, Graham R (2006) Proceedings of the SMST 2006, Pacific Grove, California Ed. Berg B, Mitchell MR, Proft J, 2006, pp 821–828 Morgan N, Wick A, DiCello J, Graham R (2006) Proceedings of the SMST 2006, Pacific Grove, California Ed. Berg B, Mitchell MR, Proft J, 2006, pp 821–828
8.
Zurück zum Zitat Rahim M, Frenzel J, Frotscher M, Pfetzing-Micklich J, Steegmuller R, Wohlschlogel M, Mughrabi H, Eggeler G (2013) Impurity levels and fatigue lives of pseudoelastic NiTi shape memory alloys. Acta Mater 61:3667–3686CrossRef Rahim M, Frenzel J, Frotscher M, Pfetzing-Micklich J, Steegmuller R, Wohlschlogel M, Mughrabi H, Eggeler G (2013) Impurity levels and fatigue lives of pseudoelastic NiTi shape memory alloys. Acta Mater 61:3667–3686CrossRef
9.
Zurück zum Zitat ASTM F2063-12 (2012) Standard specification for wrought nickel-titanium shape memory alloys for medical devices and surgical implants. ASTM International, West Conshohocken ASTM F2063-12 (2012) Standard specification for wrought nickel-titanium shape memory alloys for medical devices and surgical implants. ASTM International, West Conshohocken
10.
Zurück zum Zitat Knight R, Smith RW, Apelian D (1991) Application of plasma arc melting technology to processing of reactive metals. Int Mater Rev 36(6):221–252CrossRef Knight R, Smith RW, Apelian D (1991) Application of plasma arc melting technology to processing of reactive metals. Int Mater Rev 36(6):221–252CrossRef
11.
Zurück zum Zitat Johnson TP, Jesper NE, Young JM, Ward RM, Jacobs MH (1993) The microstructure of plasma arc cold-hearth melted Ti-48Al-2Mn-2Nb. J Phys IV. doi:10.1051/jp4:1993758 Johnson TP, Jesper NE, Young JM, Ward RM, Jacobs MH (1993) The microstructure of plasma arc cold-hearth melted Ti-48Al-2Mn-2Nb. J Phys IV. doi:10.​1051/​jp4:​1993758
12.
Zurück zum Zitat Stumpp H et al (1989) Advanced production of superalloy and titanium ingots by cold hearth melting. SAMPE J 25(3):21–26 Stumpp H et al (1989) Advanced production of superalloy and titanium ingots by cold hearth melting. SAMPE J 25(3):21–26
13.
Zurück zum Zitat Buttrill WH, Hunter GB, Shamblen CE, Melting Hearth (1993) Hearth melting of titanium alloys for aircraft engine applications. Metallurgy and technology of practical titanium alloys. TMS, Warrendale Buttrill WH, Hunter GB, Shamblen CE, Melting Hearth (1993) Hearth melting of titanium alloys for aircraft engine applications. Metallurgy and technology of practical titanium alloys. TMS, Warrendale
14.
Zurück zum Zitat Wightman P, Hensberger E (1991) Cold hearth refining of special metals. Met Mater 7(11):676–681 Wightman P, Hensberger E (1991) Cold hearth refining of special metals. Met Mater 7(11):676–681
15.
Zurück zum Zitat Chinnis WR (1990) Plasma Cold Hearth Melting of Titanium. In: Bakish R (ed) A production furnace, electron beam melting and refining state of the art. NJ, Englewood, pp 128–134 Chinnis WR (1990) Plasma Cold Hearth Melting of Titanium. In: Bakish R (ed) A production furnace, electron beam melting and refining state of the art. NJ, Englewood, pp 128–134
16.
Zurück zum Zitat Coluzzi B, Biscarini A, Mazzolai G, Mazzolai FM, Tuissi A (2004) Scripta Mater 51:199–202CrossRef Coluzzi B, Biscarini A, Mazzolai G, Mazzolai FM, Tuissi A (2004) Scripta Mater 51:199–202CrossRef
17.
Zurück zum Zitat Besseghini S, Villa E, Tuissi A (1999) Mater Sci Eng A 273–275:390–394CrossRef Besseghini S, Villa E, Tuissi A (1999) Mater Sci Eng A 273–275:390–394CrossRef
18.
Zurück zum Zitat Tuissi A, Besseghini S, Masini R, Cito F, Carcano G, Olzi E (1997) Plasma melting of supercontucting NbTi alloys. Vuoto Sci Technol 26:10–13 Tuissi A, Besseghini S, Masini R, Cito F, Carcano G, Olzi E (1997) Plasma melting of supercontucting NbTi alloys. Vuoto Sci Technol 26:10–13
19.
Zurück zum Zitat Besseghini S, Tuissi A, Olzi E, Cito F, Carcano G (1997) Melting of NiTi based shape memory alloys. Vuoto Sci Technol 26:5–9 Besseghini S, Tuissi A, Olzi E, Cito F, Carcano G (1997) Melting of NiTi based shape memory alloys. Vuoto Sci Technol 26:5–9
20.
Zurück zum Zitat ASTM G5-14 (2014) Standard reference test method for making potentiodynamic anodic polarization measurements. ASTM International, West Conshohocken ASTM G5-14 (2014) Standard reference test method for making potentiodynamic anodic polarization measurements. ASTM International, West Conshohocken
21.
Zurück zum Zitat ASTM G61-86(2014), Standard test method for conducting cyclic potentiodynamic polarization measurements for localized corrosion susceptibility of iron-, nickel-, or cobalt-based alloys ASTM G61-86(2014), Standard test method for conducting cyclic potentiodynamic polarization measurements for localized corrosion susceptibility of iron-, nickel-, or cobalt-based alloys
23.
Zurück zum Zitat Tuissi A et al (2004) Fabrication process and characterization of NiTi wires for actuators, Proceedings of SMST 2004, Baden-Baden, Germany, pp. 501–508 Tuissi A et al (2004) Fabrication process and characterization of NiTi wires for actuators, Proceedings of SMST 2004, Baden-Baden, Germany, pp. 501–508
24.
Zurück zum Zitat Casati R, Tuissi A, Belochapkine S, Dickinson C, Tofail SAM (2012) Thin NiTi wires with reduced thermal hysteresis for shape memory actuators. Funct Mater. Lett. 5:1250009CrossRef Casati R, Tuissi A, Belochapkine S, Dickinson C, Tofail SAM (2012) Thin NiTi wires with reduced thermal hysteresis for shape memory actuators. Funct Mater. Lett. 5:1250009CrossRef
25.
Zurück zum Zitat Burstein GT, Pistorius PC (1995) Surface roughness and the metastable pitting of stainless steel in chloride solutions. Corrosion 51(5):380–385CrossRef Burstein GT, Pistorius PC (1995) Surface roughness and the metastable pitting of stainless steel in chloride solutions. Corrosion 51(5):380–385CrossRef
26.
Zurück zum Zitat Burstein GT, Burstein SP (2001) Vines repetitive nucleation of corrosion pits on stainless steel and the effects of surface roughness. Electrochem Soc 148(12):B504–B516CrossRef Burstein GT, Burstein SP (2001) Vines repetitive nucleation of corrosion pits on stainless steel and the effects of surface roughness. Electrochem Soc 148(12):B504–B516CrossRef
27.
Zurück zum Zitat Bai Z, Rotermund H (2011) Assessing the corrosion behaviour of nitinol for minimally-invasive device design. J Biomed Mater Res B Appl Biomater 99B(1):1CrossRef Bai Z, Rotermund H (2011) Assessing the corrosion behaviour of nitinol for minimally-invasive device design. J Biomed Mater Res B Appl Biomater 99B(1):1CrossRef
28.
Zurück zum Zitat Admedes S (2004) Boundary for the use of Nitinol in medical applications, SMST 2004 Proceedings, October 3–7, 2004, Baden-Baden, Germany, Mertmann M (ed) ISBN:0-87170-8345 pp 563–571 Admedes S (2004) Boundary for the use of Nitinol in medical applications, SMST 2004 Proceedings, October 3–7, 2004, Baden-Baden, Germany, Mertmann M (ed) ISBN:0-87170-8345 pp 563–571
29.
Zurück zum Zitat Wu W, Liu X, Han H, Yang D, Lu S (2008) Electropolishing of NiTi for improving biocompatibility. J Mater Sci Technol 24(6):926 Wu W, Liu X, Han H, Yang D, Lu S (2008) Electropolishing of NiTi for improving biocompatibility. J Mater Sci Technol 24(6):926
30.
Zurück zum Zitat Cissè O, Savadogo O, Wu M, Yahia LH (2002) Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution. J Biomed Mater Res 61(3):339CrossRef Cissè O, Savadogo O, Wu M, Yahia LH (2002) Effect of surface treatment of NiTi alloy on its corrosion behavior in Hanks’ solution. J Biomed Mater Res 61(3):339CrossRef
31.
Zurück zum Zitat Pound BG (2002) Susceptibility of Nitinol to localized corrosion. J Biomed Mater Res A 77A:185CrossRef Pound BG (2002) Susceptibility of Nitinol to localized corrosion. J Biomed Mater Res A 77A:185CrossRef
32.
Zurück zum Zitat Eiselstein LE, Duane S, Nissan A, Corlett N, Dugnani R, Kus E, Stewart SG (2009) Acceptance criteria for corrosion resistance of medical devices: statistical analysis of nitinol pitting in in vivo environments. JMEPEG 18:768–780CrossRef Eiselstein LE, Duane S, Nissan A, Corlett N, Dugnani R, Kus E, Stewart SG (2009) Acceptance criteria for corrosion resistance of medical devices: statistical analysis of nitinol pitting in in vivo environments. JMEPEG 18:768–780CrossRef
33.
Zurück zum Zitat Rondelli G, Vicentini B, Cigada A (1990) The corrosion behaviour of nickel titanium shape memory alloys. Corr Sci 30(8/9):805–812CrossRef Rondelli G, Vicentini B, Cigada A (1990) The corrosion behaviour of nickel titanium shape memory alloys. Corr Sci 30(8/9):805–812CrossRef
34.
Zurück zum Zitat Venugopalan R, Trepanier C (2000) Assessing the corrosion behaviour of nitinol for minimally-invasive device design. Min InvasTher Allied Technol 9(2):67–74CrossRef Venugopalan R, Trepanier C (2000) Assessing the corrosion behaviour of nitinol for minimally-invasive device design. Min InvasTher Allied Technol 9(2):67–74CrossRef
35.
Zurück zum Zitat ASTM F2129-08 (2008) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices. ASTM International, West Conshohocken ASTM F2129-08 (2008) Standard test method for conducting cyclic potentiodynamic polarization measurements to determine the corrosion susceptibility of small implant devices. ASTM International, West Conshohocken
36.
Zurück zum Zitat S.N. Rosenbloom, R.A. Corbett, An Assessment of ASTM F 2129 Electrochemical Testing of Small Medical Implants Lessons Learned, NACE Conference, 2007, Paper 07674 S.N. Rosenbloom, R.A. Corbett, An Assessment of ASTM F 2129 Electrochemical Testing of Small Medical Implants Lessons Learned, NACE Conference, 2007, Paper 07674
Metadaten
Titel
Plasma Arc Melting (PAM) and Corrosion Resistance of Pure NiTi Shape Memory Alloys
verfasst von
A. Tuissi
G. Rondelli
P. Bassani
Publikationsdatum
01.03.2015
Verlag
Springer International Publishing
Erschienen in
Shape Memory and Superelasticity / Ausgabe 1/2015
Print ISSN: 2199-384X
Elektronische ISSN: 2199-3858
DOI
https://doi.org/10.1007/s40830-015-0011-6

Weitere Artikel der Ausgabe 1/2015

Shape Memory and Superelasticity 1/2015 Zur Ausgabe

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.