Abstract

There are three kinds of axial overlap between pneumatic servo valve spool and valve sleeve, namely positive overlap, zero overlap, and negative overlap. Positive overlap, also known as negative opening state, refers to the width of spool shoulder is larger than the width of valve sleeve groove, geometrically forming a positive overlap, negative opening state. Zero overlap, also known as zero opening state, refers to the width of spool shoulder equal to the width of valve sleeve groove, geometrically forming a zero opening state.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Araki K (1979, 1981) Frequency characteristics of pneumatic spool valves and cylinders with uneven underlaps (1st to 4th report) [J]. Hydraul Pneumatics 10(1):57–63, 10(6):361-367, 12(4):262-268, 269-276 Araki K (1979, 1981) Frequency characteristics of pneumatic spool valves and cylinders with uneven underlaps (1st to 4th report) [J]. Hydraul Pneumatics 10(1):57–63, 10(6):361-367, 12(4):262-268, 269-276
2.
Zurück zum Zitat Araki K, Yin Y, Ishino Y (1998) Development of asymmetric electropneumatic servo valve with symmteric and even underlaps [C]. In: Proceedings of the 13th symposium on fluid control of Japan society of automatic control, Saitama, 97–100 Araki K, Yin Y, Ishino Y (1998) Development of asymmetric electropneumatic servo valve with symmteric and even underlaps [C]. In: Proceedings of the 13th symposium on fluid control of Japan society of automatic control, Saitama, 97–100
3.
Zurück zum Zitat Yin Y, Mizuno T, J Wu et al (2007) Study on pressure characteristics of asymmetric pneumatic servo valve with asymmetric load-bearing capacity [J]. China Mech Eng 18(18):2169–2173 Yin Y, Mizuno T, J Wu et al (2007) Study on pressure characteristics of asymmetric pneumatic servo valve with asymmetric load-bearing capacity [J]. China Mech Eng 18(18):2169–2173
4.
Zurück zum Zitat Yin Y, Mizuno T, Araki K (2007) Research on Asymmetric High Speed Pneumatic Servo Valve [J]. Fluid Transm Control (3):4–8 Yin Y, Mizuno T, Araki K (2007) Research on Asymmetric High Speed Pneumatic Servo Valve [J]. Fluid Transm Control (3):4–8
5.
Zurück zum Zitat Yin Y (2007) Study on characteristics of bilateral spool valve pneumatic servo valve with unequal positive opening [J]. Hydraul Pneumatics (3):74–77 Yin Y (2007) Study on characteristics of bilateral spool valve pneumatic servo valve with unequal positive opening [J]. Hydraul Pneumatics (3):74–77
6.
Zurück zum Zitat Yaobao Y, Changming L, Xiaoxiao H et al (2008) Zero flow state analysis of pneumatic servo valve with equal negative overlap [J]. Fluid Transm Control 6:9–12 Yaobao Y, Changming L, Xiaoxiao H et al (2008) Zero flow state analysis of pneumatic servo valve with equal negative overlap [J]. Fluid Transm Control 6:9–12
7.
Zurück zum Zitat Yin Y, Li C,Yan M (2010) Characteristics of Pneumatic Servovalve with Symmetrical Unequal Load and Weight [J]. J Shanghai Jiaotong Univ 44(4):500–505 Yin Y, Li C,Yan M (2010) Characteristics of Pneumatic Servovalve with Symmetrical Unequal Load and Weight [J]. J Shanghai Jiaotong Univ 44(4):500–505
8.
Zurück zum Zitat Yin Y, Araki K (2009) Modeling and analysis of pneumatic pressure control system with asymmetric pneumatic servo valve [J]. China Mech Eng 20(17):2107–2112 Yin Y, Araki K (2009) Modeling and analysis of pneumatic pressure control system with asymmetric pneumatic servo valve [J]. China Mech Eng 20(17):2107–2112
9.
Zurück zum Zitat Yin Y, Araki K, Mizuno T (2000) Development of an asymetric servovalve with even underlaps or underlaps [C]. In: Proceedings of the 39th SICE annual conference, international session paper, The Japan society of instrument and control engineers, SICE’2000,214 A-2, 229–234 Yin Y, Araki K, Mizuno T (2000) Development of an asymetric servovalve with even underlaps or underlaps [C]. In: Proceedings of the 39th SICE annual conference, international session paper, The Japan society of instrument and control engineers, SICE’2000,214 A-2, 229–234
10.
Zurück zum Zitat Yaobao Y, Araki K (1999) High speed pneumatic force control using asymmetric servo valve and single acting cylinder for resistance spot welding amchine (2st Report, Experimental of asymmetric electropneumatic servo valve and hardware compensation of closed loop pressure control system) [J]. J Jpn hydraulics pneumatic Soc 30(2):35–41 Yaobao Y, Araki K (1999) High speed pneumatic force control using asymmetric servo valve and single acting cylinder for resistance spot welding amchine (2st Report, Experimental of asymmetric electropneumatic servo valve and hardware compensation of closed loop pressure control system) [J]. J Jpn hydraulics pneumatic Soc 30(2):35–41
11.
Zurück zum Zitat Yin Y (1999) Development of asymmetric electropneumatic servo valve and hardware compensation of high speed pneumatic force control system [D]. Doctoral thesis of Saitama University (Saitama University, 1999, Dontoral thesis No255) Yin Y (1999) Development of asymmetric electropneumatic servo valve and hardware compensation of high speed pneumatic force control system [D]. Doctoral thesis of Saitama University (Saitama University, 1999, Dontoral thesis No255)
12.
Zurück zum Zitat Shearer J L (1956) Study of pneumatic processes in the continuous control of motion with compressed air (Part 1,Part 2)[J]. Trans ASME, 75:233–249 Shearer J L (1956) Study of pneumatic processes in the continuous control of motion with compressed air (Part 1,Part 2)[J]. Trans ASME, 75:233–249
13.
Zurück zum Zitat Blackburn JF, Reethof G, Shearer L (1960) J Fluid power control [M]. John Wiley&Son INC & The Technology Press of M.I.T., New York Blackburn JF, Reethof G, Shearer L (1960) J Fluid power control [M]. John Wiley&Son INC & The Technology Press of M.I.T., New York
20.
Zurück zum Zitat Araki K (1983). Pneumatic underlaps valve controlled cylinder [J]. Hydraulics Pneumatics 14(5):360–363 Araki K (1983). Pneumatic underlaps valve controlled cylinder [J]. Hydraulics Pneumatics 14(5):360–363
21.
Zurück zum Zitat Yiyi Qu (1986) Pneumatic Servo System [M]. Shanghai Jiaotong University Press, Shanghai Yiyi Qu (1986) Pneumatic Servo System [M]. Shanghai Jiaotong University Press, Shanghai
22.
Zurück zum Zitat Araki K (1984) Frequency response of a pneumatic valve controlled cylinder with an uneven-underlap four-way valve(Part 2, Part 4) [J]. J Fluid Control, ASME 15(1):22–64 Araki K (1984) Frequency response of a pneumatic valve controlled cylinder with an uneven-underlap four-way valve(Part 2, Part 4) [J]. J Fluid Control, ASME 15(1):22–64
23.
Zurück zum Zitat Kenji Araki (1989) An indirect measurement method of equivalent negative underlaps of spool valve[J]. Hydraulics Pneumatics 20(1):71–76 Kenji Araki (1989) An indirect measurement method of equivalent negative underlaps of spool valve[J]. Hydraulics Pneumatics 20(1):71–76
24.
Zurück zum Zitat Yin Y, Li L (2011) A two-resistance gas pressure pneumatic pressure control circuit: CN21902393U [P] Yin Y, Li L (2011) A two-resistance gas pressure pneumatic pressure control circuit: CN21902393U [P]
25.
Zurück zum Zitat Yin Y, Li C (2008) Indirect measurement method for valve valve sleeve overlap of pneumatic servo valve and its application: 200810041108.X [P] Yin Y, Li C (2008) Indirect measurement method for valve valve sleeve overlap of pneumatic servo valve and its application: 200810041108.X [P]
26.
Zurück zum Zitat Yin Y, Huang W (2010). Balanced piston induction pneumatic pressure reducing valve: 20100232292.9 [P] Yin Y, Huang W (2010). Balanced piston induction pneumatic pressure reducing valve: 20100232292.9 [P]
27.
Zurück zum Zitat Yin Y, Ma J, Luo J (2008) On-board high-voltage hydrogen transmission system: 200810039025.7 [P] Yin Y, Ma J, Luo J (2008) On-board high-voltage hydrogen transmission system: 200810039025.7 [P]
28.
Zurück zum Zitat YIN YB, ARAKI K (1999).Charge and exhaust characteristics of a gas chamber based on an asymmetric pneumatic servovalve [C]. In: Proceeding of the 3rd international symposium on fluid power transmisssion and control, ISFP’99, Harbin, China 426–431 YIN YB, ARAKI K (1999).Charge and exhaust characteristics of a gas chamber based on an asymmetric pneumatic servovalve [C]. In: Proceeding of the 3rd international symposium on fluid power transmisssion and control, ISFP’99, Harbin, China 426–431
29.
Zurück zum Zitat YIN Y, ARAKI k (1998) Modelling and analysis of an asymmetric valve-controlled single-acting cylinder of a pneumatic force control system [C]. In: Proceedings of the 37th SICE annual conference, international session papers, SICE’98, Chiba, IEEE 1099–1104 YIN Y, ARAKI k (1998) Modelling and analysis of an asymmetric valve-controlled single-acting cylinder of a pneumatic force control system [C]. In: Proceedings of the 37th SICE annual conference, international session papers, SICE’98, Chiba, IEEE 1099–1104
30.
Zurück zum Zitat YIN Y, ARAKI K (1998) Hardware compensation of pneumatic pressure control system using asymmetric electropneumatic servo valve [J]. In: Proceedings of Japan hydraulics and pneumatics society and Japan society of mechanical engineering in Spring 1998 58–60 YIN Y, ARAKI K (1998) Hardware compensation of pneumatic pressure control system using asymmetric electropneumatic servo valve [J]. In: Proceedings of Japan hydraulics and pneumatics society and Japan society of mechanical engineering in Spring 1998 58–60
31.
Zurück zum Zitat YIN Y, ARAKI K, ISHINO Y (1998) Development of an asymmetric flow control pneumatic valve[J]. In: Proceedings of the international sessions of the 75th JSME. meeting, The Japan society of mechanical engineers, Tokyo: 86–89 YIN Y, ARAKI K, ISHINO Y (1998) Development of an asymmetric flow control pneumatic valve[J]. In: Proceedings of the international sessions of the 75th JSME. meeting, The Japan society of mechanical engineers, Tokyo: 86–89
32.
Zurück zum Zitat Kenji Araki, Yaobao Yin (1998) Research on pneumatic force control system for resistance spot welding machine [J]. Mech Des Daily Ind Newspaper 42(2):72–77 Kenji Araki, Yaobao Yin (1998) Research on pneumatic force control system for resistance spot welding machine [J]. Mech Des Daily Ind Newspaper 42(2):72–77
33.
Zurück zum Zitat Kenji Araki, Yaobao Yin (1998) High speed pneumatic force control using asymmetric servo valve and single acting cylinder for resistance spot welding amchine(1st Report) [J]. J Jpn Hydraulics Pneumatic Soc 29(1):9–15 Kenji Araki, Yaobao Yin (1998) High speed pneumatic force control using asymmetric servo valve and single acting cylinder for resistance spot welding amchine(1st Report) [J]. J Jpn Hydraulics Pneumatic Soc 29(1):9–15
34.
Zurück zum Zitat Yin Y, Araki K, Ishino Y (1997). Characteristics of pneumatic force control system using a single acting cylinder [J]. In: Proceedings of 15th symposium on fluid measurement and fluid dynamics and 12th symposium on fluid control, 45/48 Yin Y, Araki K, Ishino Y (1997). Characteristics of pneumatic force control system using a single acting cylinder [J]. In: Proceedings of 15th symposium on fluid measurement and fluid dynamics and 12th symposium on fluid control, 45/48
35.
Zurück zum Zitat Yin Y, Araki K, Chen J, Ishino Y (1997) Effect of piston position and effective area on cylinder natural frequency [J]. In: Proceedings of Japan hydraulics and pneumatics society and Japan society of mechanical engineering in Spring 1997, 77–80 Yin Y, Araki K, Chen J, Ishino Y (1997) Effect of piston position and effective area on cylinder natural frequency [J]. In: Proceedings of Japan hydraulics and pneumatics society and Japan society of mechanical engineering in Spring 1997, 77–80
36.
Zurück zum Zitat Yin Y, Zhang L, Fu Junyong (2011) A high pressure pneumatic pressure reducing valve: 201110011195.6 [P] Yin Y, Zhang L, Fu Junyong (2011) A high pressure pneumatic pressure reducing valve: 201110011195.6 [P]
Metadaten
Titel
Pneumatic Servo Valve with Negative Overlaps
verfasst von
Yaobao Yin
Copyright-Jahr
2019
Verlag
Springer Singapore
DOI
https://doi.org/10.1007/978-981-13-5986-6_4

    Marktübersichten

    Die im Laufe eines Jahres in der „adhäsion“ veröffentlichten Marktübersichten helfen Anwendern verschiedenster Branchen, sich einen gezielten Überblick über Lieferantenangebote zu verschaffen.