Skip to main content

2019 | OriginalPaper | Buchkapitel

Positioning Method for Arterial Blood Pressure Monitoring Wearable Sensor

verfasst von : Viacheslav Antsiperov, Gennady Mansurov

Erschienen in: Bioinformatics and Biomedical Engineering

Verlag: Springer International Publishing

Aktivieren Sie unsere intelligente Suche, um passende Fachinhalte oder Patente zu finden.

search-config
loading …

Abstract

Measuring blood pressure in real time using wearable sensors mounted directly on the patient’s body is promising tool for assessing the state of the cardiovascular system and signalling symptoms of cardiovascular diseases. To solve this problem, we developed a new type of wearable arterial blood pressure monitoring sensor. Constructively, this sensor can be embedded in a flexible bracelet for measuring the pressure in the underlying radial artery. Due to the very small measuring pads (less than 1 mm\(^{2}\)) and, consequently, the ability to accurately position the contact pad directly over the artery, it is possible to ensure high quality of blood pressure measurement. However, since the artery itself is generally not visible, the correct positioning of the sensor is a non-trivial problem. In the paper we propose the solution of the problem – the positioning based on monitoring the pulse wave signals using three channels from closely spaced pads of a three-chamber pneumatic sensor.

Sie haben noch keine Lizenz? Dann Informieren Sie sich jetzt über unsere Produkte:

Springer Professional "Wirtschaft+Technik"

Online-Abonnement

Mit Springer Professional "Wirtschaft+Technik" erhalten Sie Zugriff auf:

  • über 102.000 Bücher
  • über 537 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Maschinenbau + Werkstoffe
  • Versicherung + Risiko

Jetzt Wissensvorsprung sichern!

Springer Professional "Technik"

Online-Abonnement

Mit Springer Professional "Technik" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 390 Zeitschriften

aus folgenden Fachgebieten:

  • Automobil + Motoren
  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Elektrotechnik + Elektronik
  • Energie + Nachhaltigkeit
  • Maschinenbau + Werkstoffe




 

Jetzt Wissensvorsprung sichern!

Springer Professional "Wirtschaft"

Online-Abonnement

Mit Springer Professional "Wirtschaft" erhalten Sie Zugriff auf:

  • über 67.000 Bücher
  • über 340 Zeitschriften

aus folgenden Fachgebieten:

  • Bauwesen + Immobilien
  • Business IT + Informatik
  • Finance + Banking
  • Management + Führung
  • Marketing + Vertrieb
  • Versicherung + Risiko




Jetzt Wissensvorsprung sichern!

Literatur
1.
Zurück zum Zitat Campbell, N.R.C., Chockalingam, A., Fodor, J.G., McKay, D.W.: Accurate, reproducible measurement of blood pressure. Can. Med. Ass. J. 143(1), 19–24 (1990) Campbell, N.R.C., Chockalingam, A., Fodor, J.G., McKay, D.W.: Accurate, reproducible measurement of blood pressure. Can. Med. Ass. J. 143(1), 19–24 (1990)
2.
Zurück zum Zitat Peňáz, J.: Photoelectric measurement of blood pressure, volume and flow in the finger. In: Digest 10th International Conference on Medical and Biological Engineering, p. 104. Dresden, Germany (1973) Peňáz, J.: Photoelectric measurement of blood pressure, volume and flow in the finger. In: Digest 10th International Conference on Medical and Biological Engineering, p. 104. Dresden, Germany (1973)
3.
Zurück zum Zitat Pressman, G.L., Newgard, P.M.: A transducer for the continuous external measurement of arterial blood pressure. IEEE Trans. Bio-med. Electron. BME 10, 73–81 (1963)CrossRef Pressman, G.L., Newgard, P.M.: A transducer for the continuous external measurement of arterial blood pressure. IEEE Trans. Bio-med. Electron. BME 10, 73–81 (1963)CrossRef
4.
Zurück zum Zitat Mena, L.J., Felix, V.G., Ostos, R., et al.: Mobile personal health system for ambulatory blood pressure monitoring. Comp. Math. Methods Med. 2013, 1–13 (2013). Art. ID 598196CrossRef Mena, L.J., Felix, V.G., Ostos, R., et al.: Mobile personal health system for ambulatory blood pressure monitoring. Comp. Math. Methods Med. 2013, 1–13 (2013). Art. ID 598196CrossRef
5.
Zurück zum Zitat Kaisti, M., Leppanen, J., Lahdenoja, O., Kostiainen, P., et al.: Wearable pressure sensor array for health monitoring. In: Computing in Cardiology (CinC), Rennes, France, pp. 1–4 (2017) Kaisti, M., Leppanen, J., Lahdenoja, O., Kostiainen, P., et al.: Wearable pressure sensor array for health monitoring. In: Computing in Cardiology (CinC), Rennes, France, pp. 1–4 (2017)
7.
Zurück zum Zitat Mansurov, G.K., et al.: Monolithic three-chambered pneumatic sensor with integrated channels for continuous non-invasive blood pressure measurement. Invention patent 2675066, Priority 26 February 2018. Bulletin No. 35 (2018). Patent - RU 2 675 066 C1, CPC - A61B 5/022 (2018.08); A61B 5/024 (2018.08) Mansurov, G.K., et al.: Monolithic three-chambered pneumatic sensor with integrated channels for continuous non-invasive blood pressure measurement. Invention patent 2675066, Priority 26 February 2018. Bulletin No. 35 (2018). Patent - RU 2 675 066 C1, CPC - A61B 5/022 (2018.08); A61B 5/024 (2018.08)
8.
Zurück zum Zitat Antsiperov, V.E.: Multiscale correlation analysis of nonstationary signals containing quasi-periodic fragments. J. Com. Technol. Electron. 53(1), 65–77 (2008)CrossRef Antsiperov, V.E.: Multiscale correlation analysis of nonstationary signals containing quasi-periodic fragments. J. Com. Technol. Electron. 53(1), 65–77 (2008)CrossRef
Metadaten
Titel
Positioning Method for Arterial Blood Pressure Monitoring Wearable Sensor
verfasst von
Viacheslav Antsiperov
Gennady Mansurov
Copyright-Jahr
2019
DOI
https://doi.org/10.1007/978-3-030-17938-0_36